Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Hand held Massager Getting started Step 1 Firmly press and hold the center button on the button pad, then float the Theragun Elite across areas in need. Use the plus (+) and minus (-) buttons on the button pad to adjust speed. Apply light to moderate pressure as needed. Turn on and float Step 2 Get the Theragun app We’ll guide you through a stress-free setup and show you how to get the most out of your Theragun Elite. Step 3 Feel the difference.™ Every day. Take a deep breath and treat yourself with guided treatment presets or freestyle mode. It’s all designed for you. The Theragun Elite Interchangeable attachments Charging port Theragun Triangle™ multi-gripOLED screen Button pad See Warnings insert for important safety instructions Using the Theragun Elite 1. To turn on the Theragun Elite, firmly press and hold the center button on the button pad. 2. Press the plus (+) and minus (-) buttons on the button pad to increase or decrease speed. 3. Press the left (<) and right (>) arrows on the button pad to toggle between your Theragun Elite’s pre-loaded treatment presets. 4. To turn off the Theragun Elite, firmly press and hold the center button on the button pad until the device shuts down. Charging the Theragun Elite 1. After turning off the device, plug the power adapter into the Theragun Elite’s charging port. 2. The battery level will appear on the OLED screen, blinking until the battery is fully charged. 3. Charging is complete when the OLED screen shows 100% and the battery icon is full. The Theragun Elite is wireless charging enabled. For more on wireless charging, visit Theragun.com. Connecting the attachments Align the attachment with the tip of the rotating arm and push to connect. To remove, grip the attachment, placing 1 finger on each side of the plastic connector. Pull off the attachment. CorrectIncorrect Scan the QR code to get started. Smart Features Your Theragun Elite is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Theragun app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on usage. Your Theragun Elite’s OLED screen supports your app experience by displaying current speed and force to help guide your treatment. Your Theragun Elite comes with 5 different attachments designed for every muscle and need. Attachments Dampener For use on tender areas or near bones Standard Ball For overall, general use Wedge For scraping, shoulder blades, or IT bands Thumb For lower back and trigger point therapy Cone For pinpoint muscle treatment Born in Los Angeles, CA. Designed for everybody. @Theragun
WARNINGS IC 1. This device complies with Industry Canada RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment complies with ISED RF radiation exposure limits set forth for an uncontrolled environment. 1.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et. (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. 2. Les changements ou modifications non expressément approuvés par la partie responsable de la conformité peuvent annuler le droit de l'utilisateur à utiliser l'équipement. Cet appareil est conforme aux limites d'exposition de rayonnement RF ISEDC établiespour un environnement non contrôlé.
Theragun, Inc. 2803 Colorado Avenue Santa Monica 90404 USA COMPANY LETTERHEAD Date (19/05/2020) TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Dear Sir or Madam, We, (Theragun, Inc., 2803 Colorado Avenue, Santa Monica, California, 90404, United States), hereby authorize (Myron Yu [TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch, Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen 518052, P.R. China and +86 33323623) to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Type of equipment: Hand held Massager Model name: Theragun Elite FCC ID: 2AU6TELITE-01 This authorization expires on 19/11/2020. Sincerely, Company Officer: Tony Zhong Telephone Number: +86-15994710928 Email: [email protected]
Thergun, Inc. Date (09/04/2020) TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Confidentiality Request FCC ID: 2AU6TELITE-01 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Theragun, Inc.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (Theragun, Inc.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Tony Zhong Telephone Number: +86-15994710928 Email: [email protected]
Page 1 of 4 External Photos Details of: Overall view Details of: Front view Page 2 of 4 Details of: Rear view Details of: Top view Page 3 of 4 Details of: Bottom view Details of: Side view Page 4 of 4 Details of: Side view Details of: Adapter
Label and label location Dimension: 30 mm X 50 mm
Page 1 of 7 Internal Photos Details of: Inside view Details of: Inside view Receiver coil Page 2 of 7 Details of: Inside view Details of: Main board Page 3 of 7 Details of: Main board Details of: Wireless charging receiver board BLE Antenna Page 4 of 7 Details of: Wireless charging receiver board Details of: Display board Page 5 of 7 Details of: Display board Details of: Motor Page 6 of 7 Details of: Battery pack Details of: Inside view for Adapter Page 7 of 7 Details of: PCB view for Adapter Details of: PCB view for Adapter
Report Number: 68.760.19.0785.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation 1. Introduction The EUT is a Hand held Massager at 2402-2480MHz for BLE. Model: Theragun Elite FCC ID: 2AU6TELITE-01 2. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 3. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 For BLE Conducted Power + tune up tolerance = 0.42 mW Distance = 5 mm f = 2.48 GHz [0.42/5] * SQRT(2.48) =0.13 0.13 ≤ 3.0 Report Number: 68.760.19.0785.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: Jessie He/ EMC Project Manager Myron Yu/EMC Project Engineer Date: 2020-04-16 Date: 2020-04-16
Report Number: 68.760.19.0785.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 30 FCC/IC - TEST REPORT Report Number : 68.760.19.0785.01 Date of Issue: April 17, 2020 Model : Theragun Elite Product Type : Hand held Massager Applicant : Theragun, Inc. Address : 2803 Colorado Avenue, Santa Monica, California, 90404, United States Manufacturer : Theragun, Inc. Address : 2803 Colorado Avenue, Santa Monica, California, 90404, United States Test Result : ◼ Positive Negative Total pages including Appendices : 30 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 68.760.19.0785.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 30 1 Table of Contents 1 Table of Contents ..................................................................................................................................................2 2 Details about the Test Laboratory .........................................................................................................................3 3 Description of the Equipment under Test ..............................................................................................................4 4 Summary of Test Standards .................................................................................................................................5 5 Summary of Test Results ......................................................................................................................................6 6 General Remarks ..................................................................................................................................................7 7 Test Setups ...........................................................................................................................................................8 8 Systems test configuration ....................................................................................................................................9 9 Technical Requirement ...................................................................................................................................... 10 9.1 Conducted Emission .................................................................................................................................. 10 9.2 Conducted Peak output power ................................................................................................................... 13 9.3 6dB and 99% bandwidth ............................................................................................................................ 15 9.4 Power spectral density ............................................................................................................................... 18 9.5 Spurious RF conducted emissions ............................................................................................................. 20 9.6 Band edge .................................................................................................................................................. 24 9.7 Spurious radiated emissions for transmitter ............................................................................................... 26 10 Test Equipment List ........................................................................................................................................ 29 11 System Measurement Uncertainty ................................................................................................................. 30 Report Number: 68.760.19.0785.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 30 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 ISED#: 10320A CAB identifier: CN0077 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.760.19.0785.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜ…
Text truncated - open the document above for the full version.
Page 1 of 4 Test Setup Photos Conducted Emission test Remark: Wireless charging mode Radiated Emission test (9 kHz to 30MHz) Remark: Wireless charging mode Page 2 of 4 Radiated Emission test (30 MHz to 1000MHz) Remark: Wireless charging mode Radiated Emission test (30 MHz to 1000MHz) Remark: Bluetooth communication Radiated Emission test (1GHz to 18GHz) Page 3 of 4 Remark: Bluetooth communication Radiated Emission test (Above 18GHz) Remark: Bluetooth communication Page 4 of 4 RF exposure Estimation
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 420.00 µW |
ThermFace Massage
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemTheragun Prime PLUS
Equipment Class
DTS - Digital Transmission System
Theragun PRO PLUS
Equipment Class
DTS - Digital Transmission System