
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WARNINGS BEFORE USING OR CHARGING THE THERAGUN ELITE, READ ALL THE INSTRUCTIONS AND CAUTIONARY MARKINGS IN THIS MANUAL, ON THE CHARGER, AND ON THE Theragun Elite.The Theragun Elite is intended for commercial or home use. We strive to make the Theragun Elite as safe as possible. This is an advanced mechanical device with electric components. If the Theragun Elite and its accessories are not used or maintained properly, there is a risk of fire, electric shock, or injury. Do not place your finger or any objects near the metal piston above the attachment while the Theragun Elite is in use or immediately after use. The metal piston can become extremely hot. Do not use any attachments other than the ones provided by Therabody and only as instructed by Therabody. Do not use the Theragun Elite on your head or near your genitals. Do not use the Theragun Elite above the waist during pregnancy. Do not get hair caught in any moving part of the Theragun Elite. Do not use the Theragun Elite above your Adam’s apple or C4. Do not get the Theragun Elite wet. Only clean the Theragun Elite with a magic eraser or a lightly damp towel. Do not block the vents of the motor. Never attempt to disassemble the Theragun Elite. Never store the Theragun Elite at temperatures above 40 C/104 F. Only charge the Theragun Elite when the ambient temperature is between 0°C/32°F and 40°C/104°F. Never expose the Theragun Elite or its charger to water. For long-term storage, the Theragun Elite should be fully charged. This product is not intended to diagnose, treat, or prevent any diseases. When using the Theragun Elite, these basic precautions should always be followed including: 1. USE ONLY AS INSTRUCTED. Use the Theragun Elite as described in this Theragun Elite Instruction Manual. Use only Therabody recommended accessories and replacement parts. Do not carry out any maintenance other than what is shown in the Theragun Elite Instruction Manual or advised by Therabody. 2. NOT FOR CHILDREN. The Theragun Elite and charger are not intended for use by young children or persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by a responsible person. Do not allow the Theragun Elite to be used as a toy. Close attention is necessary when used by or near children. Children should be supervised to ensure that they do not play with the Theragun Elite or charger. 3. REDUCING RISK OF INJURY. Charge the Theragun Elite only with the Theragun Elite charger. Other chargers may cause personal injury or damage. Do not connect the Theragun Elite to a different power supply plug or car cigarette lighter. The internal battery will be permanently disabled or damaged. Only use the appropriate Theragun Wireless Charger to wirelessly charge the Theragun Elite. 4. CHARGING LOCATIONS. The Theragun Elite should be charged indoors in a well ventilated, dry location. Do not charge the Theragun Elite outdoors, in a bathroom or within 10 feet (3.1 metres) of a bathtub, or pool. Do not use the Theragun Elite or charger on wet surfaces and do not expose the charger to moisture, rain, or snow. Do not use the Theragun Elite or charger in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials). Sparks may be generated, possibly causing a fire. 5. UNPLUGGING THE CHARGER. Pull the plug, not the cable, to reduce the risk of damage to the electrical plug and cable. Never carry the charger by its cable. Keep the cable from heat, oil, and sharp edges. Do not use or charge with a damaged cable. Do not stretch the charger cable or place the cable under strain. Keep cable away from heated surfaces. Do not handle the charger, including the charger terminals or Theragun Elite with wet hands. 6. CHARGER CARE. Unplug the charger when not in use. Unplug the charger from the outlet when not in use for extended periods. Make sure the charger cable is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress. Have a damaged charger replaced immediately. 7. DO NOT OVERCHARGE. Do not leave the Theragun Elite connected to the charger for more than an hour after the Theragun Elite has been fully charged. The Theragun Elite includes a protection system to avoid the risk of overcharging. However, overcharging the Theragun Elite may reduce its life over time. Only charge with AC Adaptor : EA1046SAR or with the Theragun Elite Wireless Charger Stand. 8. DO NOT BLOCK MOTOR VENTS. Do not put any obstructions into vents. Do not use if any vent is blocked. Keep free of dust, lint, hair, and anything that may reduce airflow. Keep hair, loose clothing, and fingers from vents and moving parts. 9. DO NOT BURN OR INCINERATE THE THERAGUN ELITE. The internal battery may explode, causing personal injury or damage. Toxic fumes and materials are created when battery is burned. 10. DO NOT CRUSH, DROP, OR DAMAGE THE THERAGUN ELITE CHARGER. Do not use a charger that has received a sharp blow, been dropped, run over, or damaged in any way. 11. BATTERY CHEMICALS CAUSE SERIOUS BURNS. Never allow the internal battery to come into contact with the skin, eyes, or mouth. If a damaged battery leaks chemicals, use rubber or neoprene gloves to dispose of it. If skin is exposed to battery fluids, wash with soap and water, then rinse with vinegar. If eyes are exposed to battery chemicals, immediately rinse with water for 20 minutes and seek medical attention. Remove and dispose of contaminated clothing. 12. DO NOT OPERATE UNDER BLANKET AND PILLOW. Excessive heating can occur and cause fire, electric shock, or injury to persons. 13. STORING THE Theragun Elite AND CHARGER. Store in a cool, dry place. Do not store the Theragun Elite where temperatures may exceed 40°C/104°F such as in direct sunlight, in a vehicle, or metal building during the summer. 14. DISPOSING OF BATTERIES. The internal Theragun Lithium-ion batteries for the Theragun Elite are mo…
Text truncated - open the document above for the full version.
Getting started Step 1 Firmly press and hold the center button on the button pad, then float the Theragun Elite across areas in need. Use the plus (+) and minus (-) buttons on the button pad to adjust speed. Apply light to moderate pressure as needed. Turn on and float Step 2 Get the Therabody app We’ll guide you through a stress-free setup and show you how to get the most out of your Theragun Elite. Step 3 Feel the difference.™ Every day. Take a deep breath and treat yourself with guided treatment presets or freestyle mode. It’s all designed for you. The Theragun Elite Interchangeable attachments Charging port Theragun Triangle multi-gripOLED screen Button pad See Warnings insert for important safety instructions Using the Theragun Elite 1. To turn on the Theragun Elite, firmly press and hold the center button on the button pad. 2. Press the plus (+) and minus (-) buttons on the button pad to increase or decrease speed. 3. Press the left (<) and right (>) arrows on the button pad to toggle between your Theragun Elite’s pre-loaded treatment presets. 4. To turn off the Theragun Elite, firmly press and hold the center button on the button pad until the device shuts down. Connecting the attachments Align the attachment with the tip of the rotating arm and push to connect. To remove, grip the attachment, placing 1 finger on each side of the plastic connector. Pull off the attachment. CorrectIncorrect Charging the Theragun Elite 1. After turning off the device, plug the power adapter into the Theragun Elite’s charging port. 2. The battery level will appear on the OLED screen, blinking until the battery is fully charged. 3. Charging is complete when the OLED screen shows 100% and the battery icon is full. The Theragun Elite is wireless charging enabled. For more on wireless charging, visit Therabody.com. Cleaning Instructions: For the most hygienic Theragun device experience, sanitize it after each use by: 1. Wiping the device with a disinfectant wipe to remove any residue 2. Once the device is residue-free, use a new wipe to disinfect the surface area by wiping all sides in a downward motion. Scan the QR code to get started. Smart Features Your Theragun Elite is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Therabody app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on usage. Your Theragun Elite’s OLED screen supports your app experience by displaying current speed and force to help guide your treatment. Your Theragun Elite comes with 5 different attachments designed for every muscle and need. Attachments Dampener For use on tender areas or near bones Standard Ball For overall, general use Wedge For scraping, shoulder blades, or IT bands Thumb For lower back and trigger point therapy Cone For pinpoint muscle treatment Born in Los Angeles, CA. Designed for everybody. @Therabody
Theragun, Inc. Date: 2021-04-13 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AU6TELITE-02 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch and Keny Xu in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Theragun, Inc. This authorization is valid until further written notice from the applicant. Print Name: Felix Chen Title: Signature: On behalf of Company: Theragun, Inc. Telephone: 0086-13823630081 E-mail: [email protected] 2021/04/15
Theragun, Inc. Date: 2021-04-13 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request regarding application for FCC ID: 2AU6TELITE-02 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Felix Chen Title: Signature: On behalf of Company: Theragun, Inc. Telephone: 0086-13823630081 E-mail: [email protected]
Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Theragun, Inc. Address 6100 Wilshire Blvd. Suite 200 Los,Angeles,California 90048-5107,United States Grantee Code 2AU6T FCC ID 2AU6TELITE-02 Authorized Contact Name Felix Chen Contact Email [email protected] Contact Phone 0086-13823630081 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a)in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b)in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c)if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d)in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e)in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f)neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g)the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: Print Name: Title: *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database 2021/04/15 Felix Chen
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZCR2104020390AT FCC ID: 2AU6TELITE-02 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 9 Internal Photos for SZCR2104020390AT FCC ID: 2AU6TELITE-02 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 9 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 8 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 9 of 9
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZCR2104020390AT Applicant: Theragun, Inc. Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los, Angeles, California, 90048-5107, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048-5107, USA Equipment Under Test (EUT): EUT Name: Massager (Theragun Elite) Model No.: Theragun Elite Trade mark: Theragun FCC ID: 2AU6TELITE-02 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2021-04-07 Date of Test: 2021-04-10 to 2021-04-19 Date of Issue: 2021-04-20 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-04-20 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 3 of 6 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 4 4.2 TEST LOCATION ................................................................................................................................ 5 4.3 TEST FACILITY .................................................................................................................................. 5 4.4 DEVIATION FROM STANDARDS ............................................................................................................ 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 5 5 SAR EVALUATION ................................................................................................................................. 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ........................................................................................ 6 5.1.1 Standard Requirement ................................................................................................................ 6 5.1.2 Limits .......................................................................................................................................... 6 5.1.3 EUT RF Exposure ....................................................................................................................... 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: DC 20V from adapter input AC 120V/60Hz Adapter Model: A1046SAR AC Input: 100-240V~, 1.5A, 50/60Hz DC Output: 20.0V 2.25A 45.0W Lithium Ion Battery: 10.8V 2500mAh rechargeable battery which charged by adapter Cable(s): DC cable: 100cm unshielded Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 LE Data Rate: 1Mb/s Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: -3dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039003 Page: 6 of 6 5 SAR Evaluation 5.1 RF Exposure Compliance Requirement 5.1.1 Standard Requirement According to KDB447498D01 G…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039002 Page: 1 of 50 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2104020390AT Applicant: Theragun, Inc. Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los, Angeles, California, 90048-5107, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048-5107, USA Equipment Under Test (EUT): EUT Name: Massager (Theragun Elite) Model No.: Theragun Elite Trade Mark: Theragun FCC ID: 2AU6TELITE-02 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2021-04-07 Date of Test: 2021-04-10 to 2021-04-19 Date of Issue: 2021-04-20 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039002 Page: 2 of 50 Revision Record Version Chapter Date Modifier Remark 01 2021-04-20 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039002 Page: 3 of 50 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210402039002 Page: 4 of 50 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED PEAK OUTPUT POWER ................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................13 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 MINIMUM 6DB BANDWIDTH .............................................................................................................14 7.2.1 E.U.T. Operation .....................................................................................................................14 7.2.2 Test Mode Description ............................................................................................................14 7.2.3 Test Setup Diagram ......................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZCR2104020390AT FCC ID: 2AU6TELITE-02 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs Radiated Emissions which fall in the restricted bands Radiated Spurious Emissions Below 1GHz SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 Radiated Spurious Emissions Above 1GHz
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.10 mW |
ThermFace Massage
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemTheragun Prime PLUS
Equipment Class
DTS - Digital Transmission System
Theragun PRO PLUS
Equipment Class
DTS - Digital Transmission System