FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Therabody, Inc./
  3. 2AU6TMDWC-01

2AU6TMDWC-01Multi-Device Wireless Charger

Therabody, Inc.
Multi-Device Wireless Charger - FCC ID 2AU6TMDWC-01 - Therabody, Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jun 29, 2020
Application Purpose
Original Equipment
Date of Application
May 21, 2020
Equipment Note
Multi-Device Wireless Charger
Frequency Range
0.11025600 - 0.12516000
Company
Therabody, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Multi-Device Wireless Charger Theragun Multi-Device Wireless Charger The Theragun Multi-Device Wireless Charger is compatible with Theragun PRO™, Theragun Elite™, and Wave Roller™. Only ONE device can be charged at a time. 1. Plug the power adapter into the Theragun Multi-Device Wireless Charger’s charging port. 2. Turn off your Theragun PRO or Theragun Elite. 3. When holding the Theragun PRO or Theragun Elite by the top handle, attachment away from you, place the left side of the device on the plate of the Theragun Multi-Device Wireless Charger, following the shape on the top surface. 4. The LED light of the Theragun Multi-Device Wireless Charger will light up when properly connected. The Theragun PRO and Theragun Elite are fully charged when the battery icon on the device’s OLED screen is full. The Theragun PRO and Theragun Elite can remain on the Theragun Multi-Device Wireless Charger even when fully charged. Charging your Theragun PRO or Theragun Elite 1. Plug the power adapter into the Theragun Multi-Device Wireless Charger’s charging port. 2. Turn off your Wave Roller. 3. Place the base of your Wave Roller on the plate of the Theragun Multi-Device Wireless Charger, with the traditional charging port and functional buttons facing upwards. 4. The LED light of the Theragun Multi-Device Wireless Charger will light up when properly connected. The Wave Roller is fully charged when the battery indicator light is solid green. The Wave Roller can remain on the Theragun Multi-Device Wireless Charger even when fully charged. Charging your Wave Roller Born in Los Angeles, CA. Engineered for everybody.

Users Manual

WARNINGS BEFORE USING OR CHARGING THE THERAGUN PRO™, THERAGUN ELITE™, AND WAVE ROLLER™, READ THIS MANUAL AND THE CAUTIONARY MARKINGS ON THE THERAGUN MULTI-DEVICE WIRELESS CHARGER AND THE THERAGUN PRO, THERAGUN ELITE, AND WAVE ROLLER. CHARGE DEVICES BEFORE FIRST USE. We strive to make the devices, and the Theragun Multi-Device Wireless Charger, as safe as possible. These are advanced mechanical tools with electric components. If the devices, Theragun Multi-Device Wireless Charger, and their accessories are not used or maintained properly, there is a risk of fire, electric shock, or injury. When using the Theragun Multi-Device Wireless Charger, these basic precautions should always be followed: 1. USE ONLY AS INSTRUCTED. Use the Theragun Multi-Device Wireless Charger as described in this instruction Manual. Only use with Theragun AC Adapter: EA1046SAR. Use only Therabody recommended accessories and replacement parts. Do not carry out any maintenance other than as advised by Therabody. 2. NOT FOR CHILDREN. The devices and Theragun Multi-Device Wireless Charger are not intended for use by young children or persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge unless they have been given supervision or instruction by a responsible person. Close attention is necessary when used by or near children. Children should be supervised to ensure that they do not play with the devices or Theragun Multi-Device Wireless Charger. 3. REDUCING RISK OF INJURY. Charge devices only on an authorized Therabody charger. Other chargers may cause personal injury or damage. Do not connect the Theragun Multi-Device Wireless Charger to a power supply plug or car cigarette lighter, or it will be permanently disabled or damaged. 4. CHARGING LOCATIONS. Devices should be charged indoors in a well ventilated, dry location. Do not charge devices outdoors, in a bathroom, or within 10 feet (3.1 meters) of a bathtub or pool. Do not use devices or the Theragun Multi-Device Wireless Charger on wet surfaces and do not expose the charger to moisture, rain, or snow. Do not use devices or Theragun Multi-Device Wireless Charger in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials). Sparks may be generated, possibly causing a fire. 5. UNPLUGGING THE THERAGUN MULTI-DEVICE WIRELESS CHARGER. Pull the plug, not the cord, to reduce the risk of damage to the electrical plug and cord. Keep the cord from heat, oil, and sharp edges. Do not use or charge with a damaged cord. Do not stretch the charger cord or place the cord under strain. Keep cord away from heated surfaces. Do not handle the Theragun Multi-Device Wireless Charger, including the charger terminals with wet hands. 6. THERAGUN MULTI-DEVICE WIRELESS CHARGER CARE. Unplug the Theragun Multi-Device Wireless Charger when not in use. Unplug the Theragun Multi-Device Wireless Charger from the outlet when not in use for extended periods. Make sure the Theragun Multi-Device Wireless Charger cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress. Have a damaged charger replaced immediately. 7. DO NOT BURN OR INCINERATE THE Theragun Multi-Device Wireless Charger or devices. 8. DO NOT CRUSH, DROP, OR DAMAGE THE THERAGUN MULTI-DEVICE WIRELESS CHARGER. Do not use a Theragun Multi-Device Wireless Charger that has received a sharp blow, been dropped, run over, or damaged in any way. 9. STORING THE THERAGUN MULTI-DEVICE WIRELESS CHARGER. Store in a cool, dry place. Do not store the Theragun Multi-Device Wireless Charger where temperatures may exceed 40°C/104°F, such as in direct sunlight, in a vehicle, or in a metal building during the summer. 10. DO NOT DISASSEMBLE. Disassembly or incorrect reassembly may result in the risk of electric shock or fire. The warranty will be void if the Theragun Multi- Device Wireless Charger is disassembled or if any parts have been removed. 11. SERVICE. If the Theragun Multi-Device Wireless Charger is not working properly, has received a sharp blow, has been dropped, damaged, left outdoors, or dropped into water, do not use and contact Therabody by emailing [email protected] for repair or service. Do not attempt to repair or disassemble it, which may result in an electric shock or fire. 12. DO NOT USE WHILE BATHING OR IN THE SHOWER, TUB, OR SINK. Do not charge devices where they can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not reach for an appliance that has fallen into the water. Unplug immediately. 13. Devices can not be used while charging. 14. Do not try to charge other electronic devices with the Theragun Multi-Device Wireless Charger, such as phones, tablets, or smartwatches. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to LIMITED WARRANTY The Theragun Multi-Device Wireless Charger has a limited one-year warranty. For any warranty issues or questions, please email [email protected]. provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This tr…

Text truncated - open the document above for the full version.

Cover Letter(s)

Theragun, Inc. Da te : 2020-3-20 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AU6TMDWC-01 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Techni cal Servic es Co., Ltd. (SGS) Shenzhen Branch and Keny Xu in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with res pect to the FCC ID above, inclu ding signing of all documents relating to thes e matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and co ndi tions for Certification, as specified by SGS North America, Inc., still resides with Theragun, Inc. This authorization is valid until further written notice from the applicant. Print Name: Tony Zhong Title: Program manager Sig nature: On b ehalf of Company: Theragun, Inc. Telephone: (086) 15994710928 E- mail: [email protected]

Cover Letter(s)

Theragun, Inc. Date : 2020- 5-19 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Reg arding: Confidentiality Request regarding application for FCC ID: 2AU6TMDWC-01 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confid ential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Oper ational Descriptions The documents above contain proprietary information not released to the public. Public discl osure of this information may prove harmful to the business of the applicant. Sincerely, Print Name: Tony Zhong Title: Program manager Sig nature: On b ehalf of Company: Theragun, Inc. Telephone: 0086- 15994710928 E-mail: [email protected]

Cover Letter(s)

Applicant Declaration Applicant Decla ration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Theragun, Inc. Address 2803 Colorado Avenue Santa Monica California 90404 United States Grantee Code 2AU6T FCC ID 2AU6TMDWC-01 Authorized Contact Name Tony Zhong Contact Email [email protected] Contact Phone 0086-15994710928 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 2020-5-19 Print Name: Tony Zhong Title: Program manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Cover Letter(s)

Theragun, Inc. Cover Letter-Wireless Charger Approval Dat e: 2 020-3- 20 Gentlemen: There’s a Multi-Device Wireless Charger that would like to have your authorization as an Inductive wireless power transfer applications approval. The specific product as below, with its designed featur es and specifi ed description, meet s special req uirements for KDB 680106 D01 section 5.2 requirements. Company: Theragun, Inc. Product Name: Multi-Device Wireless Charger Model Number: Multi-Device Wireless Charger FCC ID: 2AU6TMDWC-01 KDB 680106 D01 Section 5.2 Requirements Product Technical Specification Result a) Power transfer frequency is less that 1 MHz 110.256-125.160kHz Complied b) Output power from each primary coil is less than or equal to 15 watts. 27 watts incomplied c) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils Complied d) Client device is placed directly in contact with the transmitter. Complied e) Mobile exposure conditions onlyFor inductive applications where the primary does not physically attach to the client, and it is intended for desktop use, the desktop guidance in KDB 680106 D01 may be applied Complied f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Please refer to RF exposure report Complied Sincerely, Print Name: Tony Zhong Title: Program manager Sig nature: On b eha lf of Company: Theragun, Inc. Telephone: (086) 15994710928 E- mail: [email protected]

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM2003001659CR FCC ID: 2AU6TMDWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6

ID Label/Location Info

Theragun, Inc. Multi-Device Wireless Charger Label size: 110*75mm

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 7 Internal Photos for SZEM2003001659CR FCC ID: 2AU6TMDWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 7 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 7

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165902 Page: 1 of 8 Keny Xu EMC Laboratory Manager 1 COVER PAGE Human Exposure Report Application No.: SZEM2003001659CR Applicant: Theragun, Inc Address of Applicant: 2803 Colorado Avenue, Santa Monica, California 90404, United States Manufacturer: Theragun, Inc Address of Manufacturer: 2803 Colorado Avenue, Santa Monica, California 90404, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C. Equipment Under Test (EUT): EUT Name: Multi-Device Wireless Charger Model No.: Multi-Device Wireless Charger Trade Mark: Theragun FCC ID: 2AU6TMDWC-01 Standards: 47 CFR PART 1, Subpart I, Section 1.1310 47 CFR PART 2, Subpart J, Section 2.1091 Date of Receipt: 2020-03-19 Date of Test: 2020-03-21 to 2020-04-30 Date of Issue: 2020-05-09 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165902 Page: 2 of 8 Revision Record Version Chapter Date Modifier Remark 01 2020-05-09 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165902 Page: 3 of 8 2 Contents 1 COVER PAGE .................................................................................................................................................. 1 2 CONTENTS ....................................................................................................................................................... 3 3 GENERAL INFORMATION ............................................................................................................................. 4 3.1 DETAILS OF E.U.T. .......................................................................................................................................... 4 3.2 TEST LOCATION ............................................................................................................................................... 5 3.3 TEST FACILITY ................................................................................................................................................ 5 3.4 DEVIATION FROM STANDARDS ......................................................................................................................... 5 3.5 ABNORMALITIES FROM STANDARD CONDITIONS ............................................................................................... 5 4 EQUIPMENTS USED DURING TEST ............................................................................................................ 6 5 TEST RESULTS ............................................................................................................................................... 7 5.1 RF EXPOSURE TEST.......................................................................................................................................... 7 5.1.1 E.U.T. Operation.................................................................................................................................. 7 5.1.2 Measurement Data .............................................................................................................................. 8 6 PHOTOGRAPHS- RF EXPOSURE SETUP ................................................................................................... 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165902 Page: 4 of 8 3 General Information 3.1 Details of E.U.T. Power Supply: Adapter: Model:EA1046SAR Input:AC 100-240V 1.5A 50/60Hz Output:DC 20V 2.25A Wireless Output:27W Operation Frequency: 110.256kHz to 125.160kHz Modulation Type: Load Modulation Antenna Type: Loop Antenna Antenna Gain: 0dBi Cable: DC cable:94cm unshielded Remark: Model No.: Multi-Device Wireless Charger The model Multi-Device Wireless Charger was tested fully, and the Conducted disturbance and Radiated emission(30M-1GHz) for discrepancy, since the electrical circuit design, PCB layout, components used and internal wiring were identical for the above models, with only difference add R48, C51, C27, CM1, C49, on PCBA , in order to improve energy, no impact RF. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165902 Page: 5 of 8 3.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab, No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accred…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165901 Page: 1 of 35 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2003001659CR Applicant: Theragun, Inc Address of Applicant: 2803 Colorado Avenue, Santa Monica, California 90404, United States Manufacturer: Theragun, Inc Address of Manufacturer: 2803 Colorado Avenue, Santa Monica, California 90404, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C. Equipment Under Test (EUT): EUT Name: Multi-Device Wireless Charger Model No.: Multi-Device Wireless Charger Trade Mark: Theragun FCC ID: 2AU6TMDWC-01 Standard(s) : 47 CFR Part 15, Subpart C Date of Receipt: 2020-03-19 Date of Test: 2020-03-21 to 2020-04-30 Date of Issue: 2020-05-09 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165901 Page: 2 of 35 Revision Record Version Chapter Date Modifier Remark 01 2020-05-09 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165901 Page: 3 of 35 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C N/A 47 CFR Part 15, Subpart C 15.203 Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass 20dB Bandwidth 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.9.2 47 CFR Part 15, Subpart C 15.215 Pass Restricted Bands 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 Pass Radiated Emissions (9kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.4 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: Multi-Device Wireless Charger The model Multi-Device Wireless Charger was tested fully, and the Conducted disturbance and Radiated emission(30M-1GHz) for discrepancy, since the electrical circuit design, PCB layout, components used and internal wiring were identical for the above models, with only difference add R48, C51, C27, CM1, C49, on PCBA , in order to improve energy, no impact RF. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165901 Page: 4 of 35 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................12 7.1.1 E.U.T. Operation .....................................................................................................................13 7.1.2 Test Setup Diagram ................................................................................................................13 7.1.3 Measurement Procedure and Data .........................................................................................13 7.2 20DB BANDWIDTH .........................................................................................................................18 7.2.1 E.U.T. Operation .....................................................................................................................18 7.2.2 Test Setup …

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2003001659CR FCC ID: 2AU6TMDWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Conducted Emissions at AC Power Line (150kHz-30MHz) Test Setup 1.2 Radiated Emissions (9kHz-30MHz) Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.3 Radiated Emissions (30MHz-1GHz) Test Setup

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 RF exposure setup for SZEM2003001659CR FCC ID: 2AU6TMDWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1.1 Test photos Test with Wave Roller with 15cm measurement distance Side 1 Side 2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Side 4 Side 3 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4 Top Bottom

Contact Information

Applicant

Felix Chen
[email protected]0086-13823630081Fax: 0755-8676 7555

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86 755 25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.110256 MHz - 0.12516 MHz-
Confidentiality
Long Term
Grant Notes
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures in this filing. Users and installers must be provided with antenna installation instructions and transmitting operating conditions for satisfying RF exposure compliance.

Other Applications from Therabody, Inc.

2AU6T-TRM

ThermFace Massage

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4M

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4D

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6TTMP

Theragun Prime PLUS

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Theragun PRO PLUS - FCC ID 2AU6TTPP - Therabody, Inc.
2AU6TTPP

Theragun PRO PLUS

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System