FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Therabody, Inc./
  3. 2AU6TPRIME-01

2AU6TPRIME-01Hand held Massager

Therabody, Inc.
Hand held Massager - FCC ID 2AU6TPRIME-01 - Therabody, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 03, 2020
Application Purpose
Original Equipment
Date of Application
Mar 03, 2020
Equipment Note
Hand held Massager
Frequency Range
2402.00000000 - 2480.00000000
Company
Therabody, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Firmly press and hold the center button on the button pad, then float the Theragun Prime across areas in need. Use the up ( ) and down (v) buttons on the button pad to adjust speed. Apply light to moderate pressure as needed. Getting started v Step 2 Get the Theragun app We’ll guide you through a stress-free setup and show you how to get the most out of your fully personalized app experience. Step 3 Feel the difference.™ Every day. Take a deep breath and treat yourself with guided treatment presets or go freestyle with 5 preset speeds. It’s all designed for you. Step 1 Turn on and float The Theragun Prime See Warnings insert for important safety instructions Theragun Triangle™ multi-grip Charging port LED speed indicator LED battery indicator Button pad Interchangeable attachments Using the Theragun Prime 1. To turn on the Theragun Prime, firmly press and hold the center button on the button pad. 2. Press the up ( ) and down (v) arrows to toggle between 5 preset speeds and adjust your treatment level. 3. To turn off the Theragun Prime, firmly press and hold the center button on the button pad. Charging the Theragun Prime 1. After turning off the device, plug the power adapter into the charging port of the Theragun Prime. 2. The LED battery indicator, located under the 5 LED speed indicator bars, will start flashing. 3. Charging is complete when all 3 LED lights of the LED battery indicator are lit. Connecting the attachments Align the attachment with the tip of the rotating arm and push to connect. To remove, grip the attachment, placing 1 finger on each side of the plastic connector. Pull off the attachment. CorrectIncorrect Smart Features Your Theragun Prime is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Theragun app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on your feedback and recent activity. It’s truly your intuitive wellness partner on your journey to feeling better and moving more freely. Every day. Scan the QR code to get started. Your Theragun Prime comes with 4 different attachments designed for every muscle and need. Attachments Dampener For use on tender areas or near bones Standard Ball For overall, general use Thumb For lower back and trigger point therapy Cone For pinpoint muscle treatment Regulatory Information FCC Information: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi- dential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer- ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encour- aged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. MODIFICATION: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the device. IC Information: -English: 1. This device complies with Industry Canada RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment complies with ISED RF radiation exposure limits set forth for an uncontrolled environment. -French: Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Cet appareil est conforme aux limites d'exposition de rayonnement RF ISEDC établiespour un environnement non contrôlé. Born in Los Angeles, CA. Designed for everybody. @Theragun

Cover Letter(s)

Theragun, Inc. Date (03/09/2020) TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Confidentiality Request FCC ID: 2AU6TPRIME-01 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Theragun, Inc.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (Theragun, Inc.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below to 08/31/2020: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Tony Zhong Telephone Number: +86 15994710928 Email: [email protected]

External Photos

Page 1 of 6 External Photos Details of: Overall view Details of: Front view Page 2 of 6 Details of: Rear view Details of: Side view Page 3 of 6 Details of: Side view Details of: Bottom view Page 4 of 6 Details of: Front view Details of: Rear view Page 5 of 6 Details of: Side view Details of: Side view Page 6 of 6 Details of: Bottom view Details of: Outside view for Adapter

ID Label/Location Info

Label and label location Size: 30 mm X 50 mm Hand Held Massager Theragun Inc. Model Number: Theragun Prime Rated Input voltage: 15V, Rated Input current: 1.5A FCC ID: 2AU6TPRIME-01 IC: 25672-PRIME01 CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Page 1 of 8 Internal Photos Details of: Inside view Details of: PCB view for main board Page 2 of 8 Details of: PCB view for main board Details of: PCB view for Bluetooth module Bluetooth Antenna Page 3 of 8 Details of: PCB view for Bluetooth module Details of: PCB view for LED/Button board Page 4 of 8 Details of: PCB view for LED/Button board Details of: Outside view for battery pack Page 5 of 8 Details of: Inside view for battery pack Details of: Battery cell Page 6 of 8 Details of: PCB view for battery pack Details of: PCB view for battery pack Page 7 of 8 Details of: DC motor (BL45E39S-12V) Details of: Inside view for Adapter Page 8 of 8 Details of: PCB view for Adapter Details of: PCB view for Adapter

RF Exposure Info

Report Number: 68.760.19.0789.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation 1. Introduction The EUT is a Hand held Massager at 2402-2480MHz for BLE. Model: Theragun Prime FCC ID: 2AU6TPRIME-01 2. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 3. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 For BLE Conducted Power + tune up tolerance = 0.54 mW Distance = 5 mm f = 2.48 GHz [0.54/5] * SQRT(2.48) =0.17 0.17 ≤ 3.0 Report Number: 68.760.19.0789.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: Jessie He/ EMC Project Manager Myron Yu/EMC Project Engineer Date: 2019-12-16 Date: 2019-12-16

Test Report

Report Number: 68.760.19.0789.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 29 FCC/IC - TEST REPORT Report Number : 68.760.19.0789.01 Date of Issue: December 16, 2019 Model : Theragun Prime Product Type : Hand held Massager Applicant : Theragun, Inc. Address : 2803 Colorado Avenue, Santa Monica, California, 90404, United States Production Facility : Suzhou WinTech Tools Manufacturing Co., Ltd. Address : NO. 286, Caofeng Road, Hefeng Industry Area, Xukou Town, Wuzhong District, 215156 Suzhou, Jiangsu, PEOPLE'S REPUBLIC OF CHINA Test Result :  Positive  Negative Total pages including Appendices : 29 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 68.760.19.0789.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 29 1 Table of Contents 1 Table of Contents ..................................................................................................................................................2 2 Details about the Test Laboratory .........................................................................................................................3 3 Description of the Equipment under Test ..............................................................................................................4 4 Summary of Test Standards .................................................................................................................................5 5 Summary of Test Results ......................................................................................................................................6 6 General Remarks ..................................................................................................................................................7 7 Test Setups ...........................................................................................................................................................8 8 Systems test configuration ....................................................................................................................................9 9 Technical Requirement ...................................................................................................................................... 10 9.1 Conducted Emission .................................................................................................................................. 10 9.2 Conducted Peak output power ................................................................................................................... 13 9.3 6dB and 99% bandwidth ............................................................................................................................ 15 9.4 Power spectral density ............................................................................................................................... 17 9.5 Spurious RF conducted emissions ............................................................................................................. 19 9.6 Band edge .................................................................................................................................................. 23 9.7 Spurious radiated emissions for transmitter ............................................................................................... 25 10 Test Equipment List ........................................................................................................................................ 28 11 System Measurement Uncertainty ................................................................................................................. 29 Report Number: 68.760.19.0789.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 29 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 ISED#: 10320A CAB identifier: CN0077 Telephone: 86 755 8828 6998…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Test Setup Photos Conducted Emission test Radiated Emission test below 1GHz Page 2 of 2 Radiated Emission test above 1GHz

Contact Information

Applicant

Felix Chen
[email protected]0086-13823630081Fax: 0755-8676 7555

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]+86-0769-89201646

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz540.00 µW
Confidentiality
Long Term
Grant Notes
Output power is peak conducted.

Other Applications from Therabody, Inc.

2AU6T-TRM

ThermFace Massage

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4M

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4D

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6TTMP

Theragun Prime PLUS

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Theragun PRO PLUS - FCC ID 2AU6TTPP - Therabody, Inc.
2AU6TTPP

Theragun PRO PLUS

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System