FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Therabody, Inc./
  3. 2AU6TPWWC-01

2AU6TPWWC-01Hand Held Massager

Therabody, Inc.
Hand Held Massager - FCC ID 2AU6TPWWC-01 - Therabody, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 08, 2020
Application Purpose
Original Equipment
Date of Application
Jan 08, 2020
Equipment Note
Hand Held Massager
Frequency Range
2402.00000000 - 2480.00000000
Company
Therabody, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PRO Professional-Grade Smart Percussive Therapy™ Device Getting started Step 1 Firmly press and hold the center button on the button pad, then float the Theragun PRO across areas in need. Use the plus (+) and minus (-) buttons on the button pad to adjust the speed. Apply light to moderate pressure as needed. Turn on and float Step 2 Get the Theragun app We’ll guide you through a stress-free setup and show you how to get the most out of your Theragun PRO. Step 3 Feel the difference.™ Every day. Take a deep breath and treat yourself with guided treatment presets or freestyle mode. It’s all designed for you. The Theragun PRO OLED screen Button pad Theragun Triangle™ multi-grip Lithium-ion battery Interchangeable attachments Rotating arm Battery release button Rotating arm button See Warnings insert for important safety instructions Using the Theragun PRO 1. Insert the lithium-ion battery fully before turning on the Theragun PRO. 2. To turn on the Theragun PRO, firmly press and hold the center button on the button pad. 3. Press the plus (+) and minus (-) buttons on the button pad to increase or decrease speed. 4. Press the left (<) and right (>) arrows on the button pad to toggle between the Theragun PRO’s pre-loaded treatment presets. 5. To turn off the Theragun PRO, firmly press and hold the center button on the button pad until the device shuts down. Connecting the attachments CorrectIncorrect Align the attachment with the tip of the rotating arm and push to connect. To remove, grip the attachment, placing 1 finger on each side of the plastic connector. Pull off the attachment. Using the rotating arm Your Theragun PRO’s rotating arm adjusts to 4 positions. To adjust the arm, push the rotating arm button on the underside of the Theragun PRO and move the arm to the desired position. Lithium-ion battery Align and insert the battery in the battery slot on the underside of the Theragun PRO with the flat side of the battery end facing the circular release button. Battery life is displayed on the Theragun PRO’s OLED screen when the device is turned on. To remove the battery, press the circular release button above the battery slot and pull the battery out. Charger Plug the charging wire into the port on the charging dock. Insert the battery into the charging dock and press down until the light flashes. Charging is complete once the light stops flashing. The Theragun PRO is wireless charging enabled. For more on wireless charging, visit Theragun.com. Your Theragun PRO is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Theragun app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on your usage. Your Theragun PRO’s OLED screen supports your app experience by displaying the current speed and force to help guide your treatment. Smart Features Scan the QR code to get started. Your Theragun PRO comes with 6 different attachments designed for every muscle and need. Dampener For use on tender areas or near bones Standard Ball For overall, general use Wedge For scraping, shoulder blades, or IT bands Attachments Thumb For lower back and trigger point therapy Cone For pinpoint muscle treatment Supersoft™ When you need a soft touch Born in Los Angeles, CA. Designed for everybody. @Theragun FCC statements should be displayed in the user manual: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IC statements should be displayed in the user manual: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment complies with IC RSS‐102 radiation exposure limits set forth for an uncontrolled environment. Cet é quipement est conforme aux limites d'expositio…

Text truncated - open the document above for the full version.

Cover Letter(s)

Theragun, Inc. Date: 2019-12-27 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AU6TPWWC-01 T o whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch and Joyce Shi in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Theragun, Inc. T his authorization is valid until further written notice from the applicant. Print Name: Frank Che Title: Program manager Signature: On behalf of Company: Theragun, Inc. Telephone: (086) 136-0250 2115 E-mail: [email protected]

Cover Letter(s)

Theragun, Inc. Date: 2020-3-09 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 From: Theragun, Inc. 2803 Colorado Avenue Santa Monica California 90404 United States Regarding: Confidentiality Request regarding application for FCC ID: 2AU6TPWWC-01 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until May 04 th , 2020. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Tony Zhong Title: Program Manager Signature: On behalf of Company: Theragun, Inc. Telephone: (086) 15994710928 E-mail: [email protected]

Cover Letter(s)

Theragun, Inc. Date : 2020-4-14 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 From: Theragun, Inc. 2803 Colorado Avenue San ta Monica California 90404 United States Reg arding: Confidentiality Request regarding application for FCC ID: 2AU6TPWWC-01 To whom it may concern: We know the following details: 1. We acknowledge the information has been publicly available on the FCC website since the original grant date. 2. The FCC has no obligation to remove any information/documentation from third-party websites. 3. We requests the following documents be held confidential until May 04th, 2020. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Tony Zhong Title: Program Manager Sig nature: On b ehal f of Company: Theragun, Inc. Telephone: (086) 15994710928 E-mail: [email protected]

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 5 External Photos for SZEM1912020822CR FCC ID: 2AU6TPWWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 5 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 5

ID Label/Location Info

Theragun Pro with wireless charger CE logo height should be more than 5mm, recycle bin height should be higher than 7mm Manufacturer: Theragun, Inc Model: Theragun Pro with wireless charger Rating voltage: 20V FCC ID: 2AU6TPWWC-01 IC: 25672-PWWC01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label size: 35x18 mm Label location:

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 7 Internal Photos for SZEM1912020822CR FCC ID: 2AU6TPWWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 7 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 7

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM1912020822CR Applicant: Theragun, Inc. Address of Applicant: 2803 Colorado Avenue Santa Monica California United States 90404 Manufacturer: Theragun, Inc Address of Manufacturer: 2803 Colorado Ave.Santa Monica, CA,90404, USA Factory: Heathcare Technology Int. Ltd Address of Factory: 15/F., Blk.B, Veristrong Ind. Centre, 36 Au Pui Wan St., Fotan, HongKong, China Equipment Under Test (EUT): EUT Name: Hand Held Massager Model No.: Theragun Pro with wireless charger Trade mark: Theragun FCC ID: 2AU6TPWWC-01 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2019-12-10 Date of Test: 2019-12-10 to 2019-12-23 Date of Issue: 2019-12-27 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2019-12-27 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 3 of 6 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION ...................................................................................................................................... 5 4.3 TEST FACILITY ........................................................................................................................................ 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 5 5 SAR EVALUATION ...................................................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 6 5.1.1 Standard Requirement ..................................................................................................................... 6 5.1.2 Limits ................................................................................................................................................ 6 5.1.3 EUT RF Exposure ............................................................................................................................ 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power Supply: Rechargeable battery:Lithiumion battery DC 14.4V 2500mAh 36Wh Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 Channel Spacing: 2MHz Number of Channels: 40 Modulation Type: GFSK Sample Type: Portable production Antenna Type: Integral Antenna Gain: 0dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082202 Page: 6 of 6 5 SAR Evaluation 5.1 RF Exposure Compliance Requirement 5.1.1 Standard Requirement Acco…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082201 Page: 1 of 53 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM1912020822CR Applicant: Theragun, Inc. Address of Applicant: 2803 Colorado Avenue Santa Monica California United States 90404 Manufacturer: Theragun, Inc Address of Manufacturer: 2803 Colorado Ave.Santa Monica, CA,90404, USA Factory: Heathcare Technology Int. Ltd Address of Factory: 15/F., Blk.B, Veristrong Ind. Centre, 36 Au Pui Wan St., Fotan, HongKong, China Equipment Under Test (EUT): EUT Name: Hand Held Massager Model No.: Theragun Pro with wireless charger Trade mark: Theragun FCC ID: 2AU6TPWWC-01 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2019-12-10 Date of Test: 2019-12-10 to 2019-12-23 Date of Issue: 2019-12-27 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082201 Page: 2 of 53 Revision Record Version Chapter Date Modifier Remark 01 2019-12-27 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082201 Page: 3 of 53 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202082201 Page: 4 of 53 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 7 4.4 TEST LOCATION ............................................................................................................................. 8 4.5 TEST FACILITY ............................................................................................................................... 8 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 8 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 8 5 EQUIPMENT LIST ............................................................................................................................... 9 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 MINIMUM 6DB BANDW IDTH .............................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Setup Diagram ................................................................................................................12 7.1.3 Measurement Procedure and Data .........................................................................................12 7.2 CONDUCTED PEAK OUTPUT POWER ................................................................................................13 7.2.1 E.U.T. Operation .....................................................................................................................14 7.2.2 Test Setup Diagram .......................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 2 Setup Photos for SZEM1912020822CR FCC ID: 2AU6TPWWC-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 2 1 Photographs 1.1 Radiated Spurious Emissions Test Setup Below 1GHz Above 1GHz

Contact Information

Applicant

Felix Chen
[email protected]0086-13823630081Fax: 0755-8676 7555

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny XU
[email protected]86 755 25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Joyce shi
[email protected]86 755-2532 8662

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from Therabody, Inc.

2AU6T-TRM

ThermFace Massage

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4M

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4D

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6TTMP

Theragun Prime PLUS

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Theragun PRO PLUS - FCC ID 2AU6TTPP - Therabody, Inc.
2AU6TTPP

Theragun PRO PLUS

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System