Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WARNINGS The Wave Solo™ is intended for commercial or home use. We strive to make the Wave Solo as safe as possible. This is an advanced mechanical device with electric components. If the Wave Solo and its accessories are not used or maintained properly, there is a risk of fire, electric shock, or injury. Do not use the Wave Solo on your head or near your genitals. Do not use the Wave Solo above the waist during pregnancy. Do not get hair caught in any moving part of the Wave Solo. Do not use the Wave Solo above your Adam’s apple or C4. Do not get the Wave Solo wet. Only clean the Wave Solo with a magic eraser or a lightly damp towel. Do not block the vents of the motor. Never attempt to disassemble the Wave Solo. Never store the Wave Solo at temperatures above 40°C/104°F. Only charge the Wave Solo when the ambient temperature is between 0°C/32°F and 40°C/104°F. Never expose the Wave Solo to water. For long-term storage, the Wave Solo should be fully charged. This product is not intended to diagnose, treat, or prevent any diseases. BEFORE USING OR CHARGING THE Wave Solo, READ ALL THE INSTRUCTIONS AND CAUTIONARY MARKINGS IN THIS MANUAL AND ON THE Wave Solo. When using the Wave Solo, these basic precautions should always be followed including: 1. USE ONLY AS INSTRUCTED. Use the Wave Solo as described in this Wave Solo Instruction Manual. Do not carry out any maintenance other than what is shown in the Wave Solo Instruction Manual or advised by Therabody. 2. NOT FOR CHILDREN. The Wave Solo is not intended for use by young children or persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by a responsible person. Do not allow the Wave Solo to be used as a toy. Close attention is necessary when used by or near children. Children should be supervised to ensure that they do not play with the Wave Solo. 3. REDUCING RISK OF INJURY. Charge the Wave Solo by plugging cable included in the package on your USB AC adapter of choice. Wave Solo can also be charged with a regular USB-C charger certified by a competent body. Do not use an AC adapter that is not certified or that has received a sharp blow, been dropped, or damaged in any way. 4. CHARGING LOCATIONS. The Wave Solo should be charged indoors in a well ventilated, dry location. Do not charge the Wave Solo outdoors, in a bathroom or within 10 feet (3.1 meters) of a bathtub, or pool. Do not use the Wave Solo on wet surfaces and do not expose the device to mois- ture, rain, or snow. Do not use the Wave Solo in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials). Sparks may be generated, possibly causing a fire. 5. DO NOT OVERCHARGE. Do not leave the Wave Solo connected to the adapter for more than an hour after the Wave Solo has been fully charged. The Wave Solo includes a protection system to avoid the risk of overcharging. However, overcharging the Wave Solo may reduce its life over time. 6. DO NOT BURN OR INCINERATE THE Wave Solo. The internal battery may explode, causing personal injury or damage. Toxic fumes and materials are created when the battery is burned. 7. DO NOT CRUSH, DROP, OR DAMAGE THE Wave Solo charging cable. Do not use a charging cable that has received a sharp blow, been dropped, run over, or damaged in any way. 8. BATTERY CHEMICALS CAUSE SERIOUS BURNS. Never allow the internal battery to come into contact with the skin, eyes, or mouth. If a damaged battery leaks chemicals, use rubber or neo- prene gloves to dispose of it. If skin is exposed to battery fluids, wash with soap and water then rinse with vinegar. If eyes are exposed to battery chemicals, immediately rinse with water for 20 minutes and seek medical attention. Remove and dispose of contaminated clothing. 9. DO NOT OPERATE UNDER BLANKET AND PILLOW. Excessive heating can occur and cause fire, electric shock, or injury to persons. 10. STORING THE Wave Solo. Store in a cool, dry place. Do not store the Wave Solo where temperatures may exceed 40°C/104°F such as in direct sunlight, in a vehicle, or metal building during the summer. 11. DISPOSING OF BATTERIES. The internal Theragun lithium-ion batteries for the Wave Solo are more environmentally friendly than some other types of batteries (e.g, nickel-cadmium). Always dispose of the Wave Solo according to government, regional, and local regulations. Contact a re- cycling agency in your area for recycling locations. Even discharged batteries contain some energy. Before disposing, use electrical tape to cover the Wave Solo’s 12V connector to prevent the battery from shorting, which could cause a fire or explosion. 12. DO NOT DISASSEMBLE. Disassembly or incorrect reassembly may result in the risk of electric shock, fire, or exposure to battery chemicals. The warranty will be void if the Wave Solo is disassem- bled or if any parts have been removed. 13. SERVICE. If the Wave Solo is not working properly, has received a sharp blow, has been dropped, damaged, left outdoors, or dropped into water, do not use and contact Therabody by emailing [email protected] for repair or service. Do not attempt to repair or disassemble the Wave Solo, which may result in an electric shock or fire. 14. DO NOT USE WHILE BATHING OR IN THE SHOWER, TUB, OR SINK. Do not place or store the Wave Solo where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not reach for an appliance that has fallen into water. Unplug immediately. 15. THERMAL LIMITER. The Wave employs an automatic reset thermal limiter that shuts off the Wave Solo to prevent overheating and fire. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly ap…
Text truncated - open the document above for the full version.
User Manual Wave Solo™ USB-C charging port LED battery indicator light LED speed indicator See Warnings insert for important safety instructions Smart Vibrating Roller using QuietRoll Technology™. Using the Wave Solo 1. To turn on the Wave Solo, firmly press and hold the power button for 1-2 seconds. 2. Press the main button to increase speeds. After the highest speed, if the button is pressed again the Wave Solo will come back to the lowest speed. 3. Place the device under the treatment area gradually applying light to moderate pressure as needed. 4. To turn off the Wave Solo, firmly press and hold the power button until the device turns off. Your Wave Solo is a smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Therabody app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Smart Features Scan the QR code to get started. Charging the Wave Solo 1. The Wave Solo is USB-C enabled. Plug the cable into your USB adapter of choice for charging. 2. The LED light on the power button will flash until fully charged. 3. Charging is complete when the LED light on the power button is solid green. 4. Battery level is continuously displayed on the LED light of the power button when the device is on. To view battery level when the device is off, briefly press the power button and the LED battery light will flash to indicate the battery level. Avoid applying alcohol-based cleaner. Born in Los Angeles, CA. Designed for everybody. @Therabody
Theragun, In c. Date: 2020-12-05 TO: Federal Communicati on Commission Equipment Authorizati on Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding:FCC ID : 2AU6TSOLO To whom it may concern: We, th e undersigned, hereby auth orize SGS-CSTC Sta ndards Technical Services Co., Ltd . (SGS) Shenzhen Branchand Keny Xu in SGS-CSTC Sta ndards Technical Services Co., Ltd . (SGS) Shenzhen Branchto act on our behalf in all manners relating to applicati on for equipment auth orizati on with respect to th e FCC ID above, including signing of all documents relating to th ese matte rs. Any and all acts carried out by th e agent on our behalf shall have th e same effe ct as acts of our own. We, th e undersigned, hereby certi fy th at we are not subject to a denial of federal benefits , th at includes FCC benefits , pursuant to Secti on 5301 of th e Anti -Drug Abuse Act of 1988, 21 U.S .C. 853(a) . Where our agent signs th e applicati on for certi ficati on on our behalf, I acknowledge th at all responsibility for complying with th e te rms and conditi ons fo r Certi ficati on, as specified by SGS North America, In c., sti ll resides withTheragun, In c. This auth orizati on is valid unti l fu rth er writte n noti ce from th e applicant. Print Name: Felix ChenTitl e: Compliance manager Signatu re: On behalf of Company: Theragun, In c. Telephone: 0086-13823630081 E-mail: felix.chen@th eragun.c om
Theragun, Inc. Date: 2020-12-05 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding:Confidentiality Request regarding application for FCC ID: 2AU6TSOLO LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or180days from the grant date, whichever is less. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Felix ChenTitle: Compliance manager Signature: On behalf of Company: Theragun, Inc. Telephone: 0086-13823630081 E-mail: [email protected]
ApplicantDeclaration ApplicantDeclaration Rev:0.0 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantLegalBusinessName Theragun,Inc. Address 6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,USA GranteeCode 2AU6T FCCID 2AU6TSOLO AuthorizedContactName FelixChen ContactEmail [email protected] ContactPhone 0086-13823630081 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html ApplicantSignature: Date: 2021.1.13 PrintName:FelixChen Title:ComplianceManager *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 5 External Photos for SZEM2012013448CR FCC ID: 2AU6TSOLO SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 5 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 5
Wave Solo 018-210053 200300050 018-210053 200300050 CMIIT ID: XXXXYYZZZZ 上海强锐康国际贸易有限公 The label information is printed on the surface of the ball
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 Internal Photos for SZEM2012013448CR FCC ID: 2AU6TSOLO SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2012013448CR Applicant: Theragun, Inc Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los Angeles, California 90048-5107, United States Manufacturer: Theragun, Inc Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, California 90048-5107, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen Equipment Under Test (EUT): EUT Name: Massager (Wave Solo) Model No.: Wave Solo Trade mark: Theragun FCC ID: 2AU6TSOLO Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-12-28 Date of Test: 2020-12-29 to 2021-01-05 Date of Issue: 2021-01-07 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-01-07 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 3 of 6 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 4 4.2 TEST LOCATION ................................................................................................................................ 5 4.3 TEST FACILITY .................................................................................................................................. 5 4.4 DEVIATION FROM STANDARDS ............................................................................................................ 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 5 5 SAR EVALUATION ................................................................................................................................. 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ........................................................................................ 6 5.1.1 Standard Requirement ................................................................................................................ 6 5.1.2 Limits .......................................................................................................................................... 6 5.1.3 EUT RF Exposure ....................................................................................................................... 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: Lithium Ion Battery: 3.7V 800mAh*2 (Model:14500) rechargeable battery which charged by USB port Cable(s): Type-C cable: 46cm unshielded Bluetooth Version: V5.0 LE Data Rate: 1Mb/s Operation Frequency: 2402MHz to 2480MHz Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: -3.0dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344803 Page: 6 of 6 5 SAR Evaluation 5.1 RF…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344802 Page: 1 of 50 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2012013448CR Applicant: Theragun, Inc Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los Angeles, California 90048-5107, United States Manufacturer: Theragun, Inc Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, California 90048-5107, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen Equipment Under Test (EUT): EUT Name: Massager (Wave Solo) Model No.: Wave Solo Trade Mark: Theragun FCC ID: 2AU6TSOLO Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-12-28 Date of Test: 2020-12-29 to 2021-01-05 Date of Issue: 2021-01-07 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344802 Page: 2 of 50 Revision Record Version Chapter Date Modifier Remark 01 2021-01-07 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344802 Page: 3 of 50 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201344802 Page: 4 of 50 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 11 6.1 ANTENNA REQUIREMENT .................................................................................................................... 11 6.1.1 Test Requirement: ....................................................................................................................... 11 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 12 7.1 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 12 7.1.1 E.U.T. Operation .......................................................................................................................... 12 7.1.2 Test Mode Description ................................................................................................................. 12 7.1.3 Test Setup Diagram ..................................................................................................................... 13 7.1.4 Measurement Procedure and Data............................................................................................. 13 7.2 MINIMUM 6DB BANDWIDTH .................................................................................................................. 14 7.2.1 E.U.T. Operation ..........................................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2012013448CR FCC ID: 2AU6TSOLO SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs Radiated Emissions which fall in the restricted bands SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 Radiated Spurious Emissions
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.70 mW |
ThermFace Massage
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemTheragun Prime PLUS
Equipment Class
DTS - Digital Transmission System
Theragun PRO PLUS
Equipment Class
DTS - Digital Transmission System