FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Therabody, Inc./
  3. 2AU6TWAVE-01

2AU6TWAVE-01Wave Roller

Therabody, Inc.
Wave Roller - FCC ID 2AU6TWAVE-01 - Therabody, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 14, 2020
Application Purpose
Original Equipment
Date of Application
May 14, 2020
Equipment Note
Wave Roller
Frequency Range
2402.00000000 - 2480.00000000
Company
Therabody, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wave Roller Wave Roller ™ Charging port LED speed indicator Plus and Minus speed buttons LED battery indicator light See Warnings insert for important safety instructions Smart Vibrating Foam Roller from the makers of Theragun. Using the Wave Roller ™ 1. To turn on the Wave Roller, firmly press and hold the power button for 1-2 seconds. 2. Wave Roller will start on the lowest of five settings. To increase speed, short press the plus button until desired speed is active. 3. Place the device under the treatment area gradually applying light to moderate pressure as needed. 4. To turn off the Wave Roller, firmly press and hold the power button until the device turns off. Your Wave Roller is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Therabody app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Smart Features Scan the QR code to get started. Charging the Wave Roller ™ 1. After turning off the device, plug the power adapter into the charging port. 2. The LED light on the power button will flash until fully charged. 3. Charging is complete when the LED light on the power button is solid green. 4. Battery level is continuously displayed on the LED light of the power button when the device is on. To view battery level when the device is off, briefly press the power button and the LED battery light will flash to indicate the battery level. Charging the Wave Roller Wirelessly Battery level on the Wave Roller is indicated with the following colors: Flashing red: Low charge Flashing blue: Half-way charged Flashing green: High charge Solid green: Fully charged

Users Manual

WARNINGS The Wave Roller™ is intended for commercial or home use. We strive to make the Wave Roller as safe as possible. This is an advanced mechanical device with electric components. If the Wave Roller and its accessories are not used or maintained properly, there is a risk of fire, electric shock, or injury. Do not place your finger or any objects near the metal piston above the attachment while the Wave Roller is in use or immediately after use. The metal piston can become extremely hot. Do not use any attachments other than the ones provided by Theragun and only as instructed by Theragun. Do not use the Wave Roller on your head or near your genitals. Do not use the Wave Roller above the waist during pregnancy. Do not get hair caught in any moving part of the Wave Roller. Do not use the Wave Roller above your Adam’s apple or C4. Do not get the Wave Roller wet. Only clean the Wave Roller with a magic eraser or a lightly damp towel. Do not block the vents of the motor. Never attempt to disassemble the Wave Roller. Never store the Wave Roller at temperatures above 40°C/104°F. Only charge the Wave Roller when the ambient temperature is between 0°C/32°F and 40°C/104°F. Never expose the Wave Roller or its adapter to water. For long-term storage, the Wave Roller should be fully charged. This product is not intended to diagnose, treat, or prevent any diseases. BEFORE USING OR CHARGING THE Wave Roller, READ ALL THE INSTRUCTIONS AND CAUTIONARY MARKINGS IN THIS MANUAL, ON THE ADAPTER, AND ON THE Wave Roller. When using the Wave Roller, these basic precautions should always be followed including: 1. USE ONLY AS INSTRUCTED. Use the Wave Roller as described in this Wave Roller Instruction Manual. Do not carry out any maintenance other than what is shown in the Wave Roller Instruction Manual or advised by Theragun. 2. NOT FOR CHILDREN. The Wave Roller and adapter are not intended for use by young children or persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by a responsible person. Do not allow the Wave Roller to be used as a toy. Close attention is necessary when used by or near children. Children should be supervised to ensure that they do not play with the Wave Roller or adapter. 3. REDUCING RISK OF INJURY. Charge the Wave Roller only with the Wave Roller adapter. Other adapters may cause personal injury or damage. Do 4. CHARGING LOCATIONS. The Wave Roller should be charged indoors in a well ventilated, dry location. Do not charge the Wave Roller outdoors, in a bathroom or within 10 feet (3.1 meters) of a bathtub, or pool. Do not use the Wave Roller or adapter on wet surfaces and do not expose the adapter to moisture, rain, or snow. Do not use the Wave Roller or adapter in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials). Sparks may be generated, possibly causing a fire. 5. UNPLUGGING THE Adapter. Pull the plug, not the cable, to reduce the risk of damage to the electrical plug and cable. Never carry the adapter by its cable. Keep the cable from heat, oil, and sharp edges. Do not use or charge with a damaged cable. Do not stretch the adapter cable or place the cable under strain. Keep cable away from heated surfaces. Do not handle the adapter, including the adapter terminals or Wave Roller with wet hands. Only charge with AC Adapter : EA1046SAR or with the Theragun Multi-Device Wireless Charger. 6. Adapter CARE. Unplug the adapter when not in use. Unplug the adapter from the outlet when not in use for extended periods. Make sure the adapter cable is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress. Have a damaged adapter replaced immediately. 7. DO NOT OVERCHARGE. Do not leave the Wave Roller connected to the adapter for more than an hour after the Wave Roller has been fully charged. The Wave Roller includes a protection system to avoid the risk of overcharging. However, overcharging the Wave Roller may reduce its life over time. 8. DO NOT BURN OR INCINERATE THE Wave Roller. The internal battery may explode, causing personal injury or damage. Toxic fumes and materials are created when battery is burned. 9. DO NOT CRUSH, DROP, OR DAMAGE THE Wave Roller Adapter. Do not use a adapter that has received a sharp blow, been dropped, run over, or damaged in any way. 10. BATTERY CHEMICALS CAUSE SERIOUS BURNS. Never allow the internal battery to come into contact with the skin, eyes, or mouth. If a damaged battery leaks chemicals, use rubber or neoprene gloves to dispose of it. If skin is exposed to battery fluids, wash with soap and water then rinse with vinegar. If eyes are exposed to battery chemicals, immediately rinse with water for 20 minutes and seek medical attention. Remove and dispose of contaminated clothing. 11. DO NOT OPERATE UNDER BLANKET AND PILLOW. Excessive heating can occur and cause fire, electric shock, or injury to persons. 12. STORING THE Wave Roller AND Adapter. Store in a cool, dry place. Do not store the Wave Roller where temperatures may exceed 40°C/104°F such as in direct sunlight, in a vehicle, or metal building during the summer. 13. DISPOSING OF BATTERIES. The internal Theragun Lithium-ion batteries for the Wave Roller are more environmentally friendly than some other types of batteries (e.g, nickel-cadmium). Always dispose of the Wave Roller according to government, regional, and local regulations. Contact a recycling agency in your area for recycling locations. Even discharged batteries contain some energy. Before disposing, use electrical tape to cover the Wave Roller’s 12V connector to prevent the battery from shorting, which could cause a fire or explosion. 14. DO NOT DISASSEMBLE. Disassembly or incorrect reassembly may result in the risk of electric shock, fire, or exposure to battery chemicals. The warranty will be void if the Wave Roller or adapter are disassembled or if any pa…

Text truncated - open the document above for the full version.

Cover Letter(s)

Theragun, Inc. Da te : 2020-3-20 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AU6TWAVE-01 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Techni cal Servic es Co., Ltd. (SGS) Shenzhen Branch and Keny Xu in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and co ndi tions for Certification, as specified by SGS North America, Inc., still resides with Theragun, Inc. This authorization is valid until further written notice from the applicant. Print Name: Tony Zhong Title: Program manager Sig nature: On b ehalf of Company: Theragun, Inc. Telephone: 0086- 15994710928 E- mail: [email protected]

Cover Letter(s)

Theragun, Inc. Date : 2020-3-20 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Reg arding: Confidential ity Request regarding application for FCC ID: 2AU6TWAVE-01 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confid ential treatment of the documents listed below, associated w ith the certification application referenced above. Schematic(s) Block Diagrams Oper ational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sin cerely, Print Name: Tony Zhong Title: Program manager Sig nature: On b ehalf of Company: Theragun, Inc. Telephone: 0086- 15994710928 E- mail: [email protected]

Cover Letter(s)

Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Theragun, Inc. Address 2803 Colorado Avenue Santa Monica California 90404 United States Grantee Code 2AU6T FCC ID 2AU6TWAVE-01 Authorized Contact Name Tony Zhong Contact Email [email protected] Contact Phone 0086-15994710928 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a)in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b)in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c)if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d)in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e)in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f)neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g)the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 2020-5-13 Print Name: Tony Zhong Title: Program manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 8 External Photos for SZEM2003001656CR FCC ID: 2AU6TWAVE-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 8 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 8 of 8

ID Label/Location Info

Theragun, Inc. Wave Roller Label size: 40*50mm

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 10 Internal Photos for SZEM2003001656CR FCC ID: 2AU6TWAVE-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 10 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 8 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 9 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 10 of 10

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM190601537303 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2003001656CR Applicant: Theragun, Inc. Address of Applicant: 2803 Colorado Avenue, Santa Monica, California 90404, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 2803 Colorado Avenue, Santa Monica, California 90404, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd. Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C Equipment Under Test (EUT): EUT Name: Wave Roller Model No.: Wave Roller Trade mark: Theragun FCC ID: 2AU6TWAVE-01 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-03-19 Date of Test: 2020-03-21 to 2020-04-25 Date of Issue: 2020-04-29 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM190601537303 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2020-04-29 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM190601537303 Page: 3 of 6 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION ...................................................................................................................................... 5 4.3 TEST FACILITY ........................................................................................................................................ 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 5 5 SAR EVALUATION ...................................................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 6 5.1.1 Standard Requirement ..................................................................................................................... 6 5.1.2 Limits ................................................................................................................................................ 6 5.1.3 EUT RF Exposure ............................................................................................................................ 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM190601537303 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: Rechargeable battery: DC 11.1V 1950mAh(Charge by adapter) Adapter: Model:EA1046SAR Input:AC 100-240V 1.5A 50/60Hz Output:DC 20V 2.25A Bluetooth Version: V5.0 LE Operation Frequency: 2402MHz to 2480MHz Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: Integral Antenna Antenna Gain: 0dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM190601537303 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM1906…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165602 Page: 1 of 48 Keny Xu EMC Laboratory Manage r TEST REPORT Application No.: SZEM2003001656CR Applicant: Theragun, Inc. Address of Applicant: 2803 Colorado Avenue, Santa Monica, California 90404, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 2803 Colorado Avenue, Santa Monica, California 90404, United States Factory: Shenzhen Xiang Zhida Technology Co., Ltd. Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C Equipment Under Test (EUT): EUT Name: Wave Roller Model No.: Wave Roller Trade Mark: Theragun FCC ID: 2AU6TWAVE-01 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-03-19 Date of Test: 2020-03-21 to 2020-04-25 Date of Issue: 2020-04-29 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165602 Page: 2 of 48 Revision Record Version Chapter Date Modifier Remark 01 2020-04-29 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165602 Page: 3 of 48 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200300165602 Page: 4 of 48 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 7 4.4 TEST LOCATION .................................................................................................................................... 8 4.5 TEST FACILITY ...................................................................................................................................... 8 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 8 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 8 5 EQUIPMENT LIST ...................................................................................................................................... 9 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 12 6.1 ANTENNA REQUIREMENT .................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 13 7.1 MINIMUM 6DB BANDWIDTH .................................................................................................................. 13 7.1.1 E.U.T. Operation .......................................................................................................................... 13 7.1.2 Test Setup Diagram ..................................................................................................................... 13 7.1.3 Measurement Procedure and Data............................................................................................. 13 7.2 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 14 7.2.1 E.U.T. Operation ...............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 2 Setup Photos for SZEM2003001656CR FCC ID: 2AU6TWAVE-01 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 2 1 Photographs 1.1 Radiated Spurious Emissions Test Setup Above 1GHz

Contact Information

Applicant

Felix Chen
[email protected]0086-13823630081Fax: 0755-8676 7555

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86 755 25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.15 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from Therabody, Inc.

2AU6T-TRM

ThermFace Massage

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4M

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4D

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6TTMP

Theragun Prime PLUS

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Theragun PRO PLUS - FCC ID 2AU6TTPP - Therabody, Inc.
2AU6TTPP

Theragun PRO PLUS

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System