Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 06, 2024
Application Purpose
Original Equipment
Date of Application
Aug 06, 2024
Equipment Note
H2O TRI 2 PRO
Frequency Range
2402.00000000 - 2480.00000000
Company
Finnovate Group, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec�on against harmful interference in a residen�al installa�on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc�ons, may cause harmful interference to radio communica�ons. However, the re is no guarantee that interference will not occur in a par�cular installa�on. If this equipment does cause harmful interference to radio or television recep�on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separa�on between the equipment and receiver. • Connect the equipment into an outl et on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Cau�on: Any changes or modifica�ons to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Opera�on is subject to the following two condi�ons: (1) This device may not cause harmful interference, and (2) this device must a ccept any interference received, including interference that may cause undesired opera�on. RF Exposure Informa�on The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condi�on without restric�on.

Attestation Statements

FINNOVATE GROUP, LLC (DBA H2O AUDIO) Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/29/24 U.S. Agent Designation FINNOVATE GROUP, LLC (DBA H2O AUDIO) acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AUCH-H2OTRI2PRO): Name and company of U.S. agent: FINNOVATE GROUP, LLC (DBA H2O AUDIO) Physical U.S. address of agent: 124 E. Cliff St. Suite C-1. Solana Beach CA 92075 USA +1 858 7714410 FRN of U.S. agent: 0028742823. Email address of U.S. agent: [email protected] FINNOVATE GROUP, LLC (DBA H2O AUDIO acknowledges their obligation to accept service of process on behalf of FINNOVATE GROUP, LLC (DBA H2O AUDIO FINNOVATE GROUP, LLC (DBA H2O AUDIO with the FRN 0028742823. accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Kristian Rauhala General Manager FINNOVATE GROUP, LLC (DBA H2O AUDIO) Signature Kristian Rauhala CEO FINNOVATE GROUP, LLC (DBA H2O AUDIO)

External Photos

Page 1 of 4 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7

ID Label/Location Info

Page 1 of 1 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 2.0cm x W 1.0cm) Label Location H2O TRI 2 PRO Test Model: H2O TRI 2 PRO FCC: 2AUCH-H2OTRI2PRO

Internal Photos

Page 1 of 5 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna Page 4 of 5 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9

RF Exposure Info

Page 1 of 3 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2AUCH-H2OTRI2PRO Product name : H2O TRI 2 PRO Test Model : H2O TRI 2 PRO Power Supply : Input: DC 5V Battery: DC 3.8V 170mAh Hardware Version : V03 Software Version V03 Bluetooth : 2402MHz ~ 2480MHz Channel Number : 79 channels for Bluetooth V5.4 (DSS) Channel Spacing : 1MHz for Bluetooth V5.4(DSS) Modulation Type : GFSK , π/4-DQPSK, 8-DPSK for Bluetooth V5.4 (DSS) Bluetooth Version : V5.4 Antenna Type : Ceramic Antenna Antenna Gain : 2.58dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation Page 2 of 3 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results, <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.88 39 2441 0.52 78 2480 0.66 π/4-DQPSK 0 2402 1.06 39 2441 0.48 78 2480 -0.44 8-DPSK 0 2402 0.62 39 2441 -0.08 78 2480 -0.05 Page 3 of 3 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Manufacturing Tolerance <BT> GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 π/4-DQPSK (Pea…

Text truncated - open the document above for the full version.

Test Report

2.4GHz 3216 Chip Antenna: RAN3216F6P2G45 ______________________________________________________________________________________________________ Application: WLAN, 802.11b/g, Bluetooth, etc... Features SMD, high reliability, ultra Impact, Omni-directional... Part number RAN 3216 - F6 (1) (2) (3) P 2G45 (4) (5) (1)Product Type Chip Antenna (2)Size Code 3.2x1.6mm (3)Type Code F6 (4)Packing Paper Tape (5)Frequency 2.45GHz Electrical Specification W orking Frequency Range 2400 ~2484 MHz Peak Gain 2.58 dBi (Typ.) Impedance 50 Ohm Return loss 10 dB ( Min) Polarization Linear Azimuth Beamwidth Omni-directional Operation Temperature(°C) -40 ~85°C The specification is defined on EVB. Dimension and Terminal Configuration Dimension (mm) No. Terminal Name L 3.15+-0.15 1 Feeding point W 1.55+-0.15 2 GND T 0.50+-0.10 A 0.35+-0.10 2.4GHz 3216 Chip Antenna: RAN3216F6P2G45 ______________________________________________________________________________________________________ Evaluation Board Reference PCB Dimension Antenna Layout Reference unit :mm Electrical Characteristics Return Loss & Radiation Return Loss Frequency (MHz) (dB) 2000 10 2092 23.5 215510 Radiation Return Loss 2.4GHz 3216 Chip Antenna: RAN3216F6P2G45 ______________________________________________________________________________________________________ Taping Specifications Reel and Taping Specification Reel Specification TYPE SIZE A ψB ψC ψD W ψM 3216 7” 5K/Reel 2.0±0.5 13.5±1.0 21±1.0 60±1.0 11.5±2.0 178±2.0 Tapping Specification Packaging Type A B W E F G H T ψ D P Paper Type 3216 1.90±0.20 3.50±0.20 8.0±0.20 1.75±0.10 3.5±0.05 4.0±0.10 2.0±0.05 0.75±0.10 +0.10 1.50 -0 4.0±0.1 2.4GHz 3216 Chip Antenna: RAN3216F6P2G45 ______________________________________________________________________________________________________ Reliability Table Test ItemProcedure Requirements Ceramic Type Remark (Reference) Electrical Characterization Fulfill the electrical specification User Spec. Thermal Shock 1. Preconditioning: 50 ± 10°C / 1 hr , then keep for 24 ± 1 hrs at room temp. 2. Initial measure: Spec: refer Initial spec. 3. Rapid change of temperature test: -30°C to +85°C; 100 cycles; 15 minutes at Lower category temperature; 15 minutes at Upper category temperature. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 107 Temperature Cycling 1. Initial measure: Spec: refer Initial spec. 2. 100 Cycles (-30°C to +85°C), Soak Mode=1 (2 Cycle/hours). 3. Measurement at 24 ± 2Hours after test condition. No Visible Damage. Fulfill the electrical specification. JESD22 JA104 High Temperature Exposure 1. Initial measure: Spec: refer Initial spec. 2. Unpowered; 500hours @ T=+85°C. 3. Measurement at 24 ± 2 hours after test. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 108 Low Temperature Storage 1. Initial measure: Spec: refer Initial spec. 2. Unpowered: 500hours @ T= -30°C. 3. Measurement at 24 ± 2 hours after test. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 108 Solderability (SMD Bottom Side) Dipping method: a. Temperature: 235 ± 5°C b. Dipping time: 3 ± 0.5s The solder should cover over 95% of the critical area of bottom side. IEC 60384-21/22 4.10 Soldering Heat Resistance (RSH) Preheating temperature: 150 ± 10°C. Preheating time: 1~2 min. Solder temperature: 260 ± 5°C. Dipping time: 5 ± 0.5s No Visible Damage.IEC 60384-21/22 4.10 Vibration5g's for 20 min., 12 cycles each of 3 orientations Note: Use 8"X5" PCB .031" thick 7 secure points on, one long side and 2 secure points at corners of opposite sides. Parts mounted within 2" from any secure point. Test from 10-2000 Hz. No Visible Damage.MIL-STD-202 Method 204 Mechanical Shock Three shocks in each direction shall be applied along the three mutually perpendicular axes of the test specimen (18 shocks) Peak value: 1,500g’s Duration: 0.5ms Velocity change: 15.4 ft/s Waveform: Half-sine No Visible Damage.MIL-STD-202 Method 213 Humidity Bias 1. Humidity: 85% R.H., Temperature: 85 ± 2 °C. 2. Time: 500 ± 24 hours. 3. Measurement at 24 ± 2hrs after test condition. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 Method 106 2.4GHz 3216 Chip Antenna: RAN3216F6P2G45 ______________________________________________________________________________________________________ Revision History Revision Date Content 1 2020/7/20New issue Board Flex (SMD) 1. Mounting method: IR-Reflow. PCB Size (L:100 × W:40 × T:1.6mm) 2. Apply the load in direction of the arrow until bending reaches 2 mm. No Visible Damage.AEC-Q200 005 AdhesionForce of 1.8Kg for 60 seconds.No Visible Damage Magnification of 20X or greater may be employed for inspection of the mechanical integrity of the device body terminals and body/terminal junction. AEC-Q200 006 Physical Dimension Any applicable method using x10 magnification, micrometers, calipers, gauges, contour projectors, or other measuring equipment, capable of determining the actual specimen dimensions. In accordance with specification. JESD22 JB100

Test Report

Page 1 of 37 FCC ID: 2AUCH-H2OTRI2PRO Report No.: LCSA07104086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR Finnovate Group, LLC H2O TRI 2 PRO Test Model: H2O TRI 2 PRO Prepared for : Finnovate Group, LLC Address : 124 E. Cliff St. Suite C-1, Solana Beach California 92075 United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : July 10, 2024 Number of tested samples : 2 Sample No. : A240708073-1, A240708073-2 Serial number : Prototype Date of Test : July 10, 2024 ~ July 25, 2024 Date of Report : July 26, 2024 Page 2 of 37 FCC ID: 2AUCH-H2OTRI2PRO Report No.: LCSA07104086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCSA07104086EA Date of Issue ................................... : July 26, 2024 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Finnovate Group, LLC Address ........................................... : 124 E. Cliff St. Suite C-1, Solana Beach California 92075 United States Test Specification Standard .......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ..................... : TRF-4-E-148 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : H2O TRI 2 PRO Trade Mark ...................................... : H2O AUDIO Test Model ...................................... : H2O TRI 2 PRO Ratings ............................................ : Input: DC 5V Battery: DC 3.8V 170mAh Result ........................................... : Positive Compiled by: Supervised by: Approved by: Nadia Zhou/ Administrator Cary Luo/ Technique principal Gavin Liang / Manager Page 3 of 37 FCC ID: 2AUCH-H2OTRI2PRO Report No.: LCSA07104086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA07104086EA July 26, 2024 Date of issue Test Model.............................. : H2O TRI 2 PRO EUT......................................... : H2O TRI 2 PRO Applicant............................... : Finnovate Group, LLC Address................................... : 124 E. Cliff St. Suite C-1, Solana Beach California 92075 United States Telephone............................... : / Fax.......................................... : / Manufacturer......................... : HONGBO Electronics (HK) Limited Address................................... : ROOM A1, 6/F, YUN KEI COMMERCIAL, BUILDING,NO.682 SHANGHAI STREET, KOWLOON, HONGKONG Telephone............................... : / Fax.......................................... : / Factory................................... : HONGBO Electronics (HZ) Limited Address................................... : 5th Floor, Yueshengda Industrial Park, Yuhe Road, Sanhe Street, Huiyang Economic Development Zone, Huiyang District, Huizhou City, Guangdong Province Telephone............................... : / Fax.......................................... : / Page 4 of 37 FCC ID: 2AUCH-H2OTRI2PRO Report No.: LCSA07104086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 26, 2024 Initial Issue --- Page 5 of 37 FCC ID: 2AUCH-H2OTRI2PRO Report No.: LCSA07104086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABL…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2AUCH-H2OTRI2PRO Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photo(s) of Conducted Emissions Measurement Fig. 3

Contact Information

Applicant

Kristian Rauhala(CEO)
[email protected]858 771-4410Fax: 858 771-4410

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Finnovate Group, LLC

Bluetooth headphones - FCC ID 2AUCH-RIPT-ULTRA - Finnovate Group, LLC
2AUCH-RIPT-ULTRA

Bluetooth headphones

Jul 20, 2025

Equipment Class

DTS - Digital Transmission System
TRI PRO Multi-Sport Headphone - FCC ID 2AUCH-H2OAUDIO - Finnovate Group, LLC
2AUCH-H2OAUDIO

TRI PRO Multi-Sport Headphone

Jun 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Underwater Headphones - FCC ID 2AUCH-SONAR - Finnovate Group, LLC
2AUCH-SONAR

Underwater Headphones

Nov 14, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter