2AUKO-T4MNLMBXGThermobox with RFID

Tec4med LifeScience GmbH
Thermobox with RFID - FCC ID 2AUKO-T4MNLMBXG - Tec4med LifeScience GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 29, 2020
Application Purpose
Original Equipment
Date of Application
Jan 21, 2020
Equipment Note
Thermobox with RFID
Frequency Range
13.56000000 - 13.56000000
Company
Tec4med LifeScience GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operating manual - The worlds most advanced thermal solution for goods requiring temperature control Content General Information Representation of safety notes Notes for the customer Basic safety instructions Description of the device Comissioning and operation Cleaning and care Technical data Troubleshooting and disposal Declaration of Conformity Identification of manufacterer.......................................................................................................................... Purpose of the operating manual.................................................................................................................. Functional description.......................................................................................................................................... Intended use and foreseeable misuse...................................................................................................... General LED / display functions..................................................................................................................... General button functions................................................................................................................................... Opening / closing NelumBox®........................................................................................................................ Emergency release............................................................................................................................ Running on power supply................................................................................................................................. Scope of delivery...................................................................................................................................................... Liability and warranty coverage...................................................................................................................... Design and components..................................................................................................................................... Tips for saving energy.......................................................................................................................................... Connecting / switching on NelumBox®..................................................................................................... Transporting and storing NelumBox®........................................................................................................ Switching temperature profiles..................................................................................................................... Switching batteries............................................................................................................................................... Copyright...................................................................................................................................................................... 1 3 3 4 5 6 6 8 10 11 11 13 14 17 6 9 11 12 14 15 18 6 7 8 10 20 22 21 23 1 .1 3 .1 5 .1 6 .1 6.3 6.4 6.6 6.6.1 6.9 1.2 3.2 5.2 6.2 6.5 6.7 6.8 6.10 3.2 2 3 4 5 6 7 9 8 10 3 General Information 1 Name of manufacturer: Street: Town: Telephone: E-mail: Website: Tec4med Lifescience GmbH Otto-Hesse-Straße 19 | T9 64293 Darmstadt +49 (0) 6151 - 360 37 00 [email protected] www.tec4med.com Thank you for choosing NelumBox®! In order to ensure a quick commissioning, it is necessary for you to thoroughly read and follow the subsequent notes and descriptions. 1.1 Identification of manufacterer 4 1.2 Scope of delivery Quantity 1x 2x 1x 1x 1x 1x 1x NelumBox® Li-Ion Battery Power Supply 100 - 240 V AC Replaceable NIST calibrated Pt-100 temperature sensor Docking-Station 100 - 240 V AC (optional) RFID card RFID token (optional) Designation Before putting the unit into operation, check that all parts be- longing to the scope of delivery are present. 5 DANGER! WARNING! FACTS! This symbol signifies imminent dan- ger for the life and health of persons. This symbol signifies potential risks to property and/or the environment. This symbol indicates important facts and especially useful items of information. Tips for saving energy. No spray water. Electronic equipment may not be disposed of with household waste. Environmentally hazardous. 2 Representation of safety notes 6 3 Notes for the customer 3.1 Purpose of the operating manual This operating manual contains important information for safe, correct and economical operation of the device. Observing the instructions will help to avoid dangers, reduce repair and increase the reliability and prolong the service life of the device. Please keep the manual for future use. 3.2 Liability and warranty coverage All information in this manual are provided to the best of our knowl- edge, on the basis of our experience and findings to date. The original version of this manual was drawn up in the German lan- guage and its technical correctness checked by our company. The translation into the customer’s national language/the contractual lan- guage has been carried out by a recognised translation agency. This manual has been drafted with the utmost care. Should you nev- ertheless establish any gaps and/or errors, please notify us at the abovestated address. Your suggestions for improvements will assist us in designing a user-friendly manual. 3.3 Copyright All rights are expressly reserved. This manual may not be duplicated or its contents divulged to third parties in any form whatsoever without our written consent. Danger! 7 • If the unit shows visible damage, it must not be put into operation. • If the connecting cable of this unit is damaged, it must be replaced by the manufacturer or a similarly qualified person to avoid hazards. • Repairs to this unit may only be carried out by qualified personnel. Improper repairs can pose considerable…

Text truncated - open the document above for the full version.

Cover Letter(s)

Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 07 January 2020 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2AUKO-T4MNLMBXG To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☐ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☐ for an initial period of days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Christian Kiermeier Agent

External Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex B Page 1 of 5 1 Annex B – EUT pictures external 1.1 List of Pictures Picture 1: EUT front side.................................................................................................... 2 Picture 2: EUT back side ................................................................................................... 2 Picture 3: AC/DC power adaptor top side .......................................................................... 3 Picture 4: AC/DC power adaptor bottom side .................................................................... 3 Picture 5: Name plate of AC/DC power adaptor ................................................................ 4 Picture 6: Accumulator top side ......................................................................................... 4 Picture 7: Accumulator bottom side ................................................................................... 5 Picture 8: RFID tag 13.56 MHz .......................................................................................... 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex B Page 2 of 5 Picture 1: EUT front side Picture 2: EUT back side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex B Page 3 of 5 Picture 3: AC/DC power adaptor top side Picture 4: AC/DC power adaptor bottom side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex B Page 4 of 5 Picture 5: Name plate of AC/DC power adaptor Picture 6: Accumulator top side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex B Page 5 of 5 Picture 7: Accumulator bottom side Picture 8: RFID tag 13.56 MHz

Internal Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 1 of 11 1 Annex C – internal pictures 1.1 List of Pictures Picture 1: EUT ................................................................................................................... 2 Picture 1: Door back view .................................................................................................. 3 Picture 1: Door side view ................................................................................................... 3 Picture 1: RFID board ........................................................................................................ 4 Picture 1: RFID board– top side ........................................................................................ 4 Picture 2: RFID board – bottom side ................................................................................. 5 Picture 9: TAPLA board – top side .................................................................................... 5 Picture 10: TAPLA board – bottom side ............................................................................ 6 Picture 2: RFID antennna .................................................................................................. 7 Picture 5: NIST board – top side ........................................................................................ 7 Picture 6: NIST board – bottom side .................................................................................. 8 Picture 2: EUT top side ...................................................................................................... 8 Picture 11: ZWIPLA board – top side ................................................................................ 9 Picture 12: ZWIPLA board – bottom side .......................................................................... 9 Picture 3: Main board – top side ........................................................................................ 10 Picture 4: Main board – bottom side .................................................................................. 10 Picture 7: Sensorhub board – top side .............................................................................. 11 Picture 8: Sensorhub board – bottom side......................................................................... 11 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 2 of 11 Picture 1: EUT EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 3 of 11 Picture 2: Door back view Picture 3: Door side view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 4 of 11 Picture 4: RFID board Picture 5: RFID board– top side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 5 of 11 Picture 6: RFID board – bottom side Picture 7: TAPLA board – top side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 6 of 11 Picture 8: TAPLA board – bottom side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 7 of 11 Picture 9: RFID antennna Picture 10: NIST board – top side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 8 of 11 Picture 11: NIST board – bottom side Picture 12: EUT top side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 9 of 11 Picture 13: ZWIPLA board – top side Picture 14: ZWIPLA board – bottom side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 10 of 11 Picture 15: Main board – top side Picture 16: Main board – bottom side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex C Page 11 of 11 Picture 17: Sensorhub board – top side Picture 18: Sensorhub board – bottom side

Test Report

All test results relate to the items tested only. For reproduction of extracts of this test report, the written approval of EMV TESTHAUS GmbH is required. RF test report 190409-AU01+W02 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox Customer: TEC4MED LifeScience GmbH Otto-Hesse-Str. 19 64293 Darmstadt Germany Tel.: +49 6151 3603700 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Page 2 of 55 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: FCC test firm accreditation expiration date: 2021-05-30 MRA US-EU, FCC designation number: DE0010 FCC registration number: 97268 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Recognized on March 14 th , 2019 by the Department of Innovation, Science and Economic Development (ISED) Canada as a wireless testing laboratory CAB identifier: DE0011 ISED#: 3472A Test laboratory: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Page 3 of 55 Table of contents 1 Summary of test results ............................................................................................................ 5 2 Referenced publications ........................................................................................................... 7 3 Equipment under test (EUT) ..................................................................................................... 8 3.1 General information ........................................................................................................... 8 3.2 Radio specifications ........................................................................................................... 9 3.3 Photo documentation ......................................................................................................... 9 4 Test configuration and mode of operation ............................................................................... 10 4.1 Test configuration ............................................................................................................ 10 4.2 Mode of operation ............................................................................................................ 10 5 Test procedures...................................................................................................................... 11 5.1 General specifications ..................................................................................................... 11 5.2 AC power line conducted emission .................................................................................. 11 5.3 Radiated emissions below 30 MHz .................................................................................. 13 5.4 Radiated emissions from 30 MHz to 1 GHz ..................................................................... 15 5.5 Radiated emissions above 1 GHz .................................................................................... 18 5.6 Bandwidth measurements ............................................................................................... 21 5.7 Operation within the band 13.110 MHz - 14.010 MHz ...................................................... 22 5.8 Carrier frequency stability ................................................................................................ 22 6 Test results ............................................................................................................................. 23 6.1 AC powerline conducted emissions ................................................................................. 24 6.2 20 dB bandwidth .............................................................................................................. 30 6.3 Occupied bandwidth ........................................................................................................ 34 6.4 Operation within the band 13.110 MHz – 14.010 MHz ..................................................... 37 6.5 Carrier frequency stability ................................................................................................ 40 6.6 Emissions outside the operating frequency band(s) specified .......................................... 44 7 Equipment calibration status ................................................................................................... 53 8 Measurement uncertainties .................................................................................................... 54 9 Revision history ...................................................................................................................... 55 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Page 4 of 55 List of figures Figure 1: Setup for AC power-line conducted emissions test from 150 kHz to 30 MHz .................. 12 Figure 2: Setup for radiated emissions test below 30 MHz ............................................................ 15 Figure 3: Setup for radiated emissions test from 30 MHz to 1 GHz ............................................... 17 Figure 4: Setup for radiated emissions test above 1 GHz .............................................................. 20 Figure 5: Test setup for carrier frequency stability measurement ................................................... 22 Figure 6: Chart of AC powerline conducted emissions on L1 – without termination ....................... 26 Figure 7: Chart of AC powerline conducted emissions on N – without termination......................... 27 Figure 8: Chart of AC powerline conducted emissions on L1 – with termination ....…

Text truncated - open the document above for the full version.

Test Setup Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex A Page 1 of 4 1 Annex A – Test setup 1.1 List of Pictures Picture 1: EUT test setup radiated emission test 9 kHz – 30 MHz (front view) .................. 2 Picture 2: EUT test setup radiated emission test 9 kHz – 30 MHz (rear view) ................... 2 Picture 3: EUT test setup radiated emission test 30 MHz – 1 GHz (front view) ................. 3 Picture 4: EUT test setup radiated emission test 30 MHz – 1 GHz rear view) ................... 3 Picture 5: EUT test setup conducted emission test (front view) ......................................... 4 Picture 6: EUT test setup conducted emission test (rear view) .......................................... 4 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex A Page 2 of 4 Picture 1: EUT test setup radiated emission test 9 kHz – 30 MHz (front view) Picture 2: EUT test setup radiated emission test 9 kHz – 30 MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex A Page 3 of 4 Picture 3: EUT test setup radiated emission test 30 MHz – 1 GHz (front view) Picture 4: EUT test setup radiated emission test 30 MHz – 1 GHz rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 TEC4MED LifeScience GmbH Thermobox with RFID NelumBox 190409-AU01+W02 Annex A Page 4 of 4 Picture 5: EUT test setup conducted emission test (front view) Picture 6: EUT test setup conducted emission test (rear view)

Contact Information

Applicant

Nico Jan Hoeler(Managing Director)
[email protected]004961513603700Fax: 004961513603700

Test Firm

Element Materials Technology Straubing GmbHChristian Kiermeier
[email protected]49-9421-56868-0Fax: 49-9421-56868-100

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Confidentiality
Long Term