
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
JREMO 6K+ Rev. 1 WARRANTY ======================== JREMO ® SERIES Remote Controllers must be handled, installed, operated, and maintained by (an) authorized and (a) qualified person(s), and Upon the above condition guaranty period from the date of (delivery, installation, inspection) shall be one calendar year, Subject to confirming defects not caused by improper installation, improper operation and/or insufficient maintenance, unauthorized modification, ignorance of environmental specifications, or improper interfacing, irresistible forces such as war(s), strike(s), Act(s) of God, and so on; all such the defects shall be treated as in no warranty. JEICO ® INDUSTRIAL REMOTE CONTROLLER MODEL NAMEJREMO 6K+JREMO 6K+ SERIAL NO. CHANNEL NO. LOT. NO. PRECAUTIONS A. ANNOUNCEMENT This O&M Manual is for JREMO 6K+ and the spec. is referred to Chapter 1. Before installation and operation look through this manual and make sure having a full acknowledgement of this manual. JREMO ® series' remote controllers compose a High-Tech systemized, and a full knowledge of this manual is a must in advance of installation as well as operation of this remote controllers. Do not try to dismantle or unscrew JREMO ® series except a skilful, an expert, and an authorized. This manual is for reference and good for installation and for maintenance. For more details consult an adjacent agent and/or supplier. Each and all the JREMO ® series' remote controller is tested under severe condition and passed without any default found at factory and is ready for an immediate use for a normal/insufficient condition or so, however, in an emergency and/or in an any dangerous possibility, do not use. After use switch off the main power of the equipment(ex. crane) and confirm the receiver power off, and also confirm EMS button of the transmitter is in a pressed down position. When not in use stay the transmitter in a safety area and do not allow an unauthorized to attempt to use it. Equipment(ex. crane) using this remote controller must have main relays, limit switches, separate COM lines, and other appropriate devices for safety operation. When metal container for receiver casing is used make sure Ground(GND) to be sure connected to metal part of equipment(ex. crane). Do not use in a severe interfered area and/or lightening or so. Make sure power sources are correct. Power off and do not use during installation and/or maintenance so as to avoid any electric shock or so. Do not try to copy, modify, or release this remote controllers without permission in advance by Remohand, such an action is illegal. JREMO ® series' remote controller have many international patents, certificates, and so on. Without notice in advance and within Remohand's discretion this manual may be revised, added, and/or deleted for better use. B. GENERAL CAUTIONS Operator must be healthy both physically and mentally. Even though this remote controller is versatile, durable, and good for outdoor use try to avoid an excessive shock, pressure, wind, snow, rain, ices, or sunlight, high temperature, humid, gas, and etc. During operation when found power is weak replace all the batteries with all new 2 AA batteries. When rechargeable batteries (however, it is not recommended because of shorter life) are used, use of AA 1.2V Ni-MH 2,500 mAH or above. When not in use take out batteries from the transmitter and put aside in a different area. In an emergency follow up the below emergency measures. C. EMERGENCY MEASURES JREMO ® series has designed for safety, meeting with various kind of emergencies and for self-recovering. Billions of different I.D. code, Self-Diagnoses, super qualified and isolated protection against voltage surges and/or interferes, etc. are the basic integral functions for solving any unexpected accident or trouble in an emergency. So when such an emergent function is detected, JREMO ® series will off the work immediately and stop all the function automatically. For emergency follow up the below procedure in advance and then call an adjacent agent and/or supplier for an emergency service. 1. Press down EMS Button(red mushroom button placed at top). 2. Power off receiver power. Power off main power of Equipment. 3. Inquire adjacent JEICO agent and or supplier who can help. - Frequencies: Mhz, channels - I.D. Code: 2 32 (Over 4 Billion) - Temperature: -10 +60 - Remote Distance: 30 150 M. - Case Construction: Glass-Fiber - Protection Grade: (Tx) IP55 / (Rx) IP66 1.2 Transmitter(Tx) JEMO 6K+ - Batt. Power: 2 x 1.5 V Alkaline Batteries ( LR6 AA Size) - Type : Single or Double Push Button Type - Size: 148 x 48 x 45 mm (L x W x H) - Weight: Approx. 190 gr. (Batteries Incl.) 1.3 Receiver(Rx) - Casing: RX3 - Power: AC100240V, DC1240V(OPT.60V) - Type: Remote Main Lamp Indication - Relays: AC =>“A” Contact, 250VAC/5A, 125VAC/10A DC =>“A” Contact, 24VDC/15A, 120VAC/15A - Size, mm: 90x215x105 - Weight: Approx. 1,350 gr. (Cable Incl.) 1.4 Model Naming RX Size(Normally not indicated) JREMO 6K+ A (RX3) MODELSuffix Note : Suffix is normally not indicated on for A type. A B C M 433.050 70 434.775 output power tolerance:2.255±0.01dBm CHAPTER I : GENERAL SPECIFICATIONS 1.1. COMMON SPECIFICATION CHAPTER II JREMO 6K+ Standard Set JREMO 6K+ Standard Set comprises one transmitter and one receiver as following as a set. 2-1 STANDARD SET TxRx Rx Antenna Incl. Single or Double P/B Single P/B A/B/C/M RX3 173 x 62 x 46 mm90 x 215 x 105 mm Approx. 355 gr. Approx. 1,350 gr. FUNCTIONSMODEL NAME RECEIVER SIZE Standard Single P/B: JREMO 6K+ A ==> RX3 (22 Core Cable) U/D Creep(Double) P/B : JREMO 6K+ C ==> RX3 (22 Core Cable) 6 Double P/B: JREMO 6K+ B ==> RX3 (22 Core Cable) Single P/B For D.C.: JREMO 6K+ M ==> RX3 (22 Core Cable) Tx Button Labelling can be in English, Chinese, Japanese, Spanish, or other languages upon request. 2-2 CONTROL CONTACT WIRE DIAGRAM EMS Stop Button (Mushroom) Main On Lamp RECEIVER: RX3 SIZE : 90 x 215 x 105 mm, approx. 1,350 gr. CABLE SPEC. : 0.75 Sq, 600VAC,…
Text truncated - open the document above for the full version.
SCS-F18:ProjectandProductCertificationRepresentativeAuthorizationLetterPage1of2Rev6.0 775MontagueExpressway Milpitas,CA95035 Tel:408-526-1188 Fax:408-526-1088 Email:[email protected] ProjectandProduct CertificationRepresentative AuthorizationLetter ReasonforAmendment(current/obsolete) RevisionHistory ApprovedDate FromTo InitialRelease(obsolete)1.01.0Nov-14-2006 Revisedwording(obsolete)1.02.0Sept–25-2007 Updatedcompanytemplate(obsolete)2.03.0Jan-31-2012 Updatedletterinformation(obsolete)3.04.0May-23-2014 AddedFCCIDfield(obsolete)4.05.0Sep-16-2014 Updatedcompanyname&logo(current)5.06.0Jun-27-2018 SCS-F18:ProjectandProductCertificationRepresentativeAuthorizationLetterPage2of2Rev6.0 (JEICO) (2019-12-31) To:BVCPS,INC. 775MontagueExpressway, Milpitas,CA95035 USA DearSir/Madam, Re:ProductCertificationRepresentativeAuthorizationLetter We,_____JEICO_____herebyauthorizeBureauVeritasConsumerProductServices,Inc.toact asaCertificationBodyforcertifyingforthefollowingproject(s): FCCID:2AVDH-JREMO6K ProductDescription:Industrialwirelessremotecontroller Model:JREMO6K+,JREMO6K+A,JREMO6K+B,JREMO6K+C,JREMO6K+M,JREMO6K+G Sincerely, Client’ssignature ByunJuyong/Manager CompanyName:JEICO Address:94-1,Choryang-ro,Dong-gu,Busan48805,SouthKorea
SCS-F19:ConfidentialityRequestLetterPage 1 of 2 Rev6.0 775MontagueExpressway Milpitas,CA95035 Tel:408-526-1188 Fax:408-526-1088 Email:[email protected] Confidentiality RequestLetter ReasonforAmendment(current/obsolete) RevisionHistory ApprovedDate FromTo InitialRelease(obsolete)1.01.0Nov-14-2006 AddingCFR2.459(obsolete)1.02.0August–11-2008 Updatedcompanytemplate&Addedtextbox (obsolete) 2.03.0Jan-31-2012 AddedICconfidentialityletterform(obsolete)3.04.0March-26-2015 CorrectionstoSTCform.AddedreferencetoKDB (obsolete) 4.05.0Nov-19-2015 Updatedcompanylogo(current)5.06.0Jun-26-2019 SCS-F19:ConfidentialityRequestLetterPage 2 of 2 Rev6.0 (JEICO) (2019-12-31) To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD Subject:PermanentConfidentialityRequestforFCCID:2AVDH-JREMO6K Pursuanttosections0.457and0.459ofCFR47,werespectfullyrequestpermanentconfidentialtreatmentofthe followingExhibitsaccompanyingthisapplicationas: -BlockDiagram -Schematics -OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic.The publicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovideunjustifiedbenefitstoits competitors. Theapplicantunderstandsthatdisclosureofthisapplicationandallaccompanyingdocumentationwillnotbe madebeforethedateoftheGrantforthisapplication. Sincerely, Client’ssignature ByunJuyong/Manager CompanyName:JEICO Address:94-1,Choryang-ro,Dong-gu,Busan48805,SouthKorea
JEICO DeclarationonModelDifferences We, JEICO 94-1,Choryang-ro,Dong-gu,Busan48805,SouthKorea Declarethatthefollowingproduct(s): ProductName:Industrialwirelessremotecontroller ModelNo.:JREMO6K+,JREMO6K+A,JREMO6K+B,JREMO6K+C,JREMO6K+M, JREMO6K+G FCCID:2AVDH-JREMO6K Utilizetheidenticalcircuitdesign,PCBlayout,shieldingandinterfacewith(JREMO6K+), onlytheappearancecolorandbuttonstypedifferent.Thereforethisapplicationcanbe regardedasidenticalinperformancetothesubmittedtestsample. Themanufacturerwouldtakealltheresponsibilitiesfortheaboveproduct(s). Forandonbehalfof Busan48805,SouthKorea AuthorizedpersonLocation Name:ByunJuyong Position:Manager Dateofissue:2019-12-31 *IherebydeclarethatIamentitledtosignonbehalfoftheapplicantandthattheinformationsuppliediscorrectandcomplete.
ProductName:Industrialwirelessremotecontroller ModelNo.:JREMO6K+ FCCID:2AVDH-JREMO6K ThisdevicecomplieswithPart15oftheFCCRules.Operation issubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.
LabelLocationOnEUT
ANT
Report No.: SZAWW191121007-01FCC ID: 2AVDH-JREMO6KPage 1 of 40 Code:AB-RF-05-a FCC Test Report Client Name: JEICO Address: 94-1, Choryang-ro, Dong-gu, Busan 48805, South Korea Product Name: Industrial wireless remote controller Date: Dec. 31, 2019 Shenzhen Anbotek Compliance Laboratory Limited Report No.: SZAWW191121007-01FCC ID: 2AVDH-JREMO6KPage 2 of 40 Code:AB-RF-05-a Contents 1. General Information ............................................................................................................................................... 4 1.1. Client Information ....................................................................................................................................... 4 1.2. Description of Device (EUT) ..................................................................................................................... 4 1.3. Auxiliary Equipment Used During Test ................................................................................................... 4 1.4. Description of Test Modes ........................................................................................................................ 5 1.5. List of channels ........................................................................................................................................... 6 1.6. Description Of Test Setup ......................................................................................................................... 7 1.7. Test Equipment List .................................................................................................................................... 8 1.8. Measurement Uncertainty ......................................................................................................................... 9 1.9. Description of Test Facility ........................................................................................................................ 9 2. Summary of Test Results ................................................................................................................................... 10 3. Conducted Emission Test ................................................................................................................................... 11 3.1. Test Standard and Limit .......................................................................................................................... 11 3.2. Test Setup .................................................................................................................................................. 11 3.3. Test Procedure .......................................................................................................................................... 11 3.4. Test Data .................................................................................................................................................... 11 4. Radiation Spurious Emission and Band Edge ................................................................................................ 12 4.1. Test Standard and Limit .......................................................................................................................... 12 4.2. Test Setup .................................................................................................................................................. 13 4.3. Test Procedure .......................................................................................................................................... 14 4.4. Test Data .................................................................................................................................................... 14 5. 20DB Occupy Bandwidth Test ........................................................................................................................... 26 5.1. Test Standard and Limit .......................................................................................................................... 26 5.2. Test Setup .................................................................................................................................................. 26 5.3. Test Procedure .......................................................................................................................................... 26 5.4. Test Data .................................................................................................................................................... 26 6. Dwell Time Test .................................................................................................................................................... 29 6.1. Test Standard and Limit .......................................................................................................................... 29 6.2. Test Setup .................................................................................................................................................. 29 6.3. Test Procedure .......................................................................................................................................... 29 6.4. Test Data .................................................................................................................................................... 29 7. Antenna Requirement ......................................................................................................................................... 32 7.1. Test Standard and Requirement ............................................................................................................ 32 7.2. Antenna Connected Construction .......................................................................................................... 32 APPENDIX I -- TEST SETUP PHOTOGRAPH ................................................................................................... 33 APPENDIX II -- EXTERNAL PHOTOGRAPH ..................…
Text truncated - open the document above for the full version.
PhotoofRadiatedEmissionMeasurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.05 MHz - 434.775 MHz | - |

Industrial wireless remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Industrial wireless remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Industrial wireless remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Industrial wireless remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter