FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen SDMC Technology Co.,Ltd./
  3. 2AW68-NM1217C

2AW68-NM1217CAC1200 Dual Band Mesh Router/Dual Band Whole Home Mesh WiFi System/AC1200 Dual Band WiFi Repeater

Shenzhen SDMC Technology Co.,Ltd.
AC1200 Dual Band Mesh Router/Dual Band Whole Home Mesh WiFi System/AC1200 Dual Band WiFi Repeater - FCC ID 2AW68-NM1217C - Shenzhen SDMC Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Nov 15, 2021
Application Purpose
Original Equipment
Date of Application
Nov 07, 2021
Equipment Note
AC1200 Dual Band Mesh Router/Dual Band Whole Home Mesh WiFi System/AC1200 Dual Band WiFi Repeater
Frequency Range
5775.00000000 - 5775.00000000
Company
Shenzhen SDMC Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Installation Guide AC1200 Dual Band Mesh Router Shenzhen SDMC Technology Co., Ltd. Package Content ◼ NM1217C x 2 ◼ Ethernet Cable x 1 ◼ Power Adapter x 2 ◼ Quick Installation Guide x 1 Appearance 1. Download and install X-Link APP Scan the QR code below or on the side of the box, or search for X-Link in the mobile app market or App Store, then download and install the APP on your mobile phone. 2. Install the primary node ① Take out a node device from the box. Connect one end of the network cable to the Modem or broadband network port, and the other end of the network cable to one of WAN/LAN port of the node. ② Turn on the power, and the LED indicator will be solid red. After about 80 seconds, the LED indicator is flashing red, continue to wait the LED indicator change to solid green. 3. Install the secondary node ① Take out another node from the box and place it in a suitable position. Please refer to the following suggestions: ◼ Do not exceed two walls between the primary node and the secondary node, and the maximum distance should not exceed 20 meters. ◼ Keep away from interference sources such as microwave ovens, induction cookers, refrigerators, etc. ◼ Higher from the ground and less obstructions around. ② When the power is turned on, the LED indicator is solid red. After about 80 seconds, the system starts up and the LED indicator is flashing green. ③ Continue to observe the LED indicator until it changes from flashing green to solid green. ④ If the LED indicator is not solid green. Please re-select a suitable placement position to obtain the best connection quality. ◼ Wired device Internet access: please connect to the WAN/LAN ports of all nodes ◼ Wireless device Internet access: Please connect to the wireless network marked on the sticker at the bottom of all nodes. By default, the wireless name/password of all nodes are the same. LED Indicator status description After the power is turned on, the LED indicator will be solid red (about 80 seconds), indicating that the node's system is starting. After the start is complete, the description of LED indicator’s status is as follows Node State Description Primary Solid green Successfully connected to the Internet Flashing red Connecting to the Internet Flashing green Connecting to the secondary node Secondary Solid green Successfully connected to primary node and signal quality is good Flashing green Connecting to primary node Flashing red Failed connected to primary node Solid blue Successfully connected to primary node but signal quality is bad FAQ Q1:The device connected to node cannot access the Internet? A1:First, observe whether the LED indicator of the primary node is solid green. If not, please check whether the node's Internet access mode is set correctly. If it is correct, please contact your network operator to check whether the home network is normal. Secondly, observe whether the secondary node is solid green. If it is not, please change to a more suitable place. Q2: How to add new node? A2: Push Primary or Secondary node’s Mesh button, then push the new node’s Mesh button. If add success, the LED indicators of the two nodes change from flashing green to solid green. Q3:How to restore the factory settings of the node? A3:When the nodes are running, press and hold the reset button of the primary node with a pointed object for about 5 seconds, and release it until the LED indicator goes out. FCC Statement This equipment has been tested and found to comply with the limits for a ClassB digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party. Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2021-9-6> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AW68-NM1217C NM1217C For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos 180 Days Internal Photos 180 Days Block Diagram Schematics Test Setup Photos 180 Days User’s Manual 180 Days Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name: Ryan Yan Company: Shenzhen SDMC Technology Co.,Ltd. Address: 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 Phone: 0755-86019782 Fax: 0755-86019782 E-Mail: [email protected]

Cover Letter(s)

Shenzhen SDMC Technology Co.,Ltd. 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-9-6 To whom it may concern: We, Shenzhen SDMC Technology Co.,Ltd. the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AW68-NM1217C including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name: Ryan Yan Company: Shenzhen SDMC Technology Co.,Ltd. Address: 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 Phone: 0755-86019782 Fax: 0755-86019782 E-Mail: [email protected]

Cover Letter(s)

Shenzhen SDMC Technology Co.,Ltd. 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 UNII Device Declaration Letter To whom it may concern: We have declared below featured for FCC equipment authorization, Device FCC ID: 2AW68-NM1217C (1) DFS Device: Master Client with Radar detection capability N/A Client without radar detection capability, (2) Active / Passive Scanning , adhoc mode access point capability Frequency Band (MHz) Active Scanning (the device can transmit a probe (beacon)) passive scanning (where the device is can listen only with no probes) Ad Hoc Mode capability Access point capability 5180-5240 Yes No Yes No Yes No Yes No 5190-5230 Yes No Yes No Yes No Yes No 5210-5210 Yes No Yes No Yes No Yes No 5745-5825 Yes No Yes No Yes No Yes No 5755-5795 Yes No Yes No Yes No Yes No 5775-5775 Yes No Yes No Yes No Yes No (3) Country code selection ability Yes No If yes, pls explain how it was implemented: (4) Meet 15.202 requirement Yes No pls check below : A master device is defined as a device operating in a mode in which it has the capability to transmit without receiving an enabling signal. In this mode it is able to select a channel and initiate a network by sending enabling signals to other devices A client device is defined as a device operating in a mode in which the transmissions of the device are under control of the master. A device in client mode is not able to initiate a network. (5) For client devices that have software configuration control to operate in different modes (active scanning in some and passive scanning in others) in different bands (devices with multiple equipment classes or those that operate on non-DFS frequencies) or modular devices which configure the modes of operations through software, the application must provide software and operations description on how the software and / or hardware is implemented to ensure that proper operations modes cannot be modified by end user or an installer. Apply Does not apply (If apply, pls help to provide explanation on it was implement, and how software was controlled) Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name: Ryan Yan Company: Shenzhen SDMC Technology Co.,Ltd. Address: 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High- tech Industrial Park, Nanshan District, Shenzhen, China, 518022 Phone: 0755-86019782 Fax: 0755-86019782 E-Mail: [email protected]

External Photos

FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of Adapter 1# FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 3 Appearance of Adapter 2# Photo 4 Appearance of Adapter 3# FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 7 Appearance of EUT Photo 8 Appearance of EUT FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 9 Appearance of EUT Photo 10 Appearance of EUT

ID Label/Location Info

FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Appendix IID Label Appendix II ID Label Location

Internal Photos

FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 11 Internal of EUT Photo 12 Appearance of PCB 2.4G/5G Ant. 2 2.4G/5G Ant. 1 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 13 Appearance of PCB Photo 14 Appearance of PCB FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Photo 15 Appearance of Antenna

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TB-MPE182891 Page: 1 of 9 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID: 2AW68-NM1217C 1. Client Information Applicant : Shenzhen SDMC Technology Co.,Ltd. Address : 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 Manufacturer : Shenzhen SDMC Technology Co.,Ltd. Address : 19/F, Changhong Technology Building, No.18, Keji South 12th Road, High-tech Industrial Park, Nanshan District, Shenzhen, China, 518022 2. General Description of EUT EUT Name : AC1200 Dual Band Mesh Router Dual Band Whole Home Mesh WiFi System AC1200 Dual Band WiFi Repeater Models No. : NM1217C, DR1200M, DR1202C Model Different : All these models are identical in the same PCB, layout and electrical circuit, The only difference is model name, product name and brand name. Sample ID : 20210719-04-1#& 20210719-04-2# Product Description : Operation Frequency: 802.11b/g/n(HT20): 2412MHz~2462MHz 802.11n(HT40): 2422MHz~2452MHz U-NII-1: 5180MHz~5240MHz, U-NII-2A: 5260MHz~5320MHz U-NII-2C: 5500MHz~5700MHz U-NII-3: 5745MHz~5825MHz Power Rating : Adapter 1#(DCT12W120100US-A0): Input: 100-240V~, 50/60Hz, 0.3A Output: DC 12V1.0A Adapter 2#(SA12BV-120100U): Input: 100-240V~, 50/60Hz, 0.4A Output: DC 12V1.0A Adapter 3#(PSA126-120100U): Input: 100-240V~, 50/60Hz, 0.4A Output: DC 12V1.0A Software Version : N/A Hardware Version : N/A Report No.: TB-MPE182891 Page: 2 of 9 TB-RF-074-1.0 MPE Calculations 1. Antenna Gain: Antenna Brand Model Name Type 2.4G/5G Antenna Gain(dBi) ANT. 1 N/A N/A PCB 3 ANT. 2 N/A N/A PCB 3 2. EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 3. Exposure Evaluation: Equation from page 18 of OET Bulletin 65, Edition 97-01 S=(PG)/4πR 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna 4. Simultaneous transmission MPE Considerations According to KDB447498 :All transmitters and antennas in the host must be either evaluated for MPE compliance, by measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1.Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. This means that: ∑ of MPE ratios ≤ 1.0 Report No.: TB-MPE182891 Page: 3 of 9 TB-RF-074-1.0 5. Standalone MPE Evaluation: Mode Antenna Channel Conducted power[dBm] Turn-up Power Tolerance(dBm) 11A-CDD Ant1 5180 8.33 8±1 Ant2 5180 8.23 8±1 Ant1 5200 8.34 8±1 Ant2 5200 8.44 8±1 Ant1 5240 8.40 8±1 Ant2 5240 8.53 8±1 Ant1 5260 8.06 8±1 Ant2 5260 8.25 8±1 Ant1 5280 8.71 8±1 Ant2 5280 7.30 7±1 Ant1 5320 8.01 8±1 Ant2 5320 7.59 7±1 Ant1 5500 8.13 8±1 Ant2 5500 7.99 7±1 Ant1 5580 7.63 7±1 Ant2 5580 8.56 8±1 Ant1 5700 8.36 8±1 Ant2 5700 9.13 9±1 Ant1 5745 7.66 7±1 Ant2 5745 8.88 8±1 Ant1 5785 8.05 8±1 Ant2 5785 8.76 8±1 Ant1 5825 7.96 7±1 Ant2 5825 9.24 9±1 11N20MIMO Ant1 5180 7.87 7±1 Ant2 5180 8.85 8±1 Ant1 5200 7.90 7±1 Ant2 5200 8.16 8±1 Ant1 5240 8.16 8±1 Ant2 5240 8.30 8±1 Ant1 5260 8.36 8±1 Ant2 5260 8.93 8±1 Ant1 5280 7.92 7±1 Ant2 5280 8.21 8±1 Ant1 5320 7.92 7±1 Ant2 5320 8.68 8±1 Ant1 5500 8.23 8±1 Ant2 5500 8.29 8±1 Ant1 5580 8.31 8±1 Ant2 5580 8.29 8±1 Ant1 5700 8.09 8±1 Ant2 5700 7.92 7±1 Ant1 5745 8.61 8±1 Ant2 5745 7.64 7±1 Ant1 5785 8.33 8±1 Ant2 5785 8.12 8±1 Ant1 5825 7.96 7±1 Ant2 5825 8.28 8±1 11N40MIMO Ant1 5190 11.06 11±1 Ant2 5190 10.52 10±1 Ant1 5230 12.48 12±1 Ant2 5230 11.96 11±1 Ant1 5270 11.42 11±1 Ant2 5270 10.27 10±1 Ant1 5310 12.07 12±1 Ant2 5310 10.47 10±1 Ant1 5510 12.34 12±1 Report No.: TB-MPE182891 Page: 4 of 9 TB-RF-074-1.0 Ant2 5510 11.59 11±1 Ant1 5550 11.45 11±1 Ant2 5550 11.47 11±1 Ant1 5670 11.81 11±1 Ant2 5670 10.71 10±1 Ant1 5755 14.45 14±1 Ant2 5755 13.29 13±1 Ant1 5795 14.34 14±1 Ant2 5795 13.60 13±1 11AC20MIMO Ant1 5180 7.93 7±1 Ant2 5180 8.19 8±1 Ant1 5200 8.45 8±1 Ant2 5200 8.16 8±1 Ant1 5240 8.08 8±1 Ant2 5240 8.58 8±1 Ant1 5260 8.22 8±1 Ant2 5260 8.31 8±1 Ant1 5280 8.01 8±1 Ant2 5280 8.17 8±1 Ant1 5320 8.54 8±1 Ant2 5320 8.37 8±1 Ant1 5500 8.45 8±1 Ant2 5500 8.19 8±1 Ant1 5580 8.09 8±1 Ant2 5580 7.99 7±1 Ant1 5700 8.91 8±1 Ant2 5700 7.85 7±1 Ant1 5745 7.95 7±1 Ant2 5745 8.57 8±1 Ant1 5785 8.49 8±1 Ant2 5785 7.96 7±1 Ant1 5825 8.20 8±1 Ant2 5825 8.17 8±1 11AC40MIMO Ant1 5190 10.90 10±1 Ant2 5190 10.27 10±1 Ant1 5230 12.32 12±1 Ant2 5230 11.81 11±1 Ant1 5270 10.50 10±1 Ant2 5270 9.28 9±1 Ant1 5310 10.67 10±1 Ant2 5310 9.11 9±1 Ant1 5510 11.21 11±1 Ant2 5510 10.61 10±1 Ant1 5550 10.34 10±1 Ant2 5550 10.35 10±1 Ant1 5670 11.52 11±1 Ant2 5670 10.57 10±1 Ant1 5755 14.07 14±1 Ant2 5755 12.86 12±1 Ant1 5795 14.37 14±1 Ant2 5795 13.58 13±1 11AC80MIMO Ant1 5210 12.87 12±1 Ant2 5210 9.90 9±1 Ant1 5290 9.35 9±1 Ant2 5290 7.96 7±1 Ant1 5530 9.11 9±1 Ant2 5530 8.11 8±1 Ant1 5610 8.82 8±1 Ant2 5610 7.16 7±1 Ant1 5775 14.79 14±1 Ant2 5775 13.65 13±1 Report No.: TB-MPE182891 Page: 5 of 9 TB-RF-074-1.0 [2.4GHz WLAN] Mode Channel Frequency Peak Conducted Output Power (dBm) Turn-up Power Tolerance(dBm) Ant.1 Ant.2 Ant.1 Ant.2 IEEE 802.11b 1 2412 15.22 12.74 15±1 12±1 6 2437 10.98 14.00 10±1 14±1 11 2462 11.94 14.03 11±1 14±1 IEEE 802.11g 1 2412 15.46 12.64 15±1 12±1 6 2437 11.69 16.67 11±1 16±1 11 2462 12.90 15.57 12±1 15±1 IEEE 802.11n HT20 1 2412 15.16 12.63 15±1 12±1 6 2437 14.39 11.92 14±1 11±1 11 2462 11.89 14.34 11±1 14±1 IEEE 802.11n HT40 3 2422 12.52 12.92 12±1 12±1 6 2437 9.82 14.99 9±1 14±1 9 2452 8.92 14.73 8±1 14±1 Report No.: TB-MPE182891 Pag…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 1 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 RF Test Data for 5G Wi-Fi (Conducted Measurements) General Description of EUT Product Name: AC1200 Dual Band Mesh Router Dual Band Whole Home Mesh WiFi System AC1200 Dual Band WiFi Repeater Test Model: NM1217C Sample ID: 20210719-04-2# Environmental Conditions Temperature: 24.6°C Relative Humidity: 54% Test Voltage: DC 12V Test Engineer: Hejingchang Note: For a more detailed features description, please refer to the report TB-FCC182889 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 2 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Contents 1. Emission Bandwidth....................................................................................................................................... 3 1.1.Test Result ......................................................................................................................................... 3 1.1.Test Graphs ....................................................................................................................................... 6 2. Min emission bandwidth ............................................................................................................................. 36 2.1.Test Result ....................................................................................................................................... 36 2.2.Test Graphs ..................................................................................................................................... 37 3. Maximum conducted output power ............................................................................................................ 47 3.1.Test Result ....................................................................................................................................... 47 4. Maximum power spectral density ............................................................................................................... 51 4.1.Test Result ....................................................................................................................................... 51 4.2.Test Graphs ..................................................................................................................................... 55 5. Emissions in Restricted Bands ...................................................................................................................... 95 5.1.Test Result ....................................................................................................................................... 95 5.2.Test Graphs ................................................................................................................................... 107 6. Conducted Spurious Emission .................................................................................................................... 155 6.1.Test Result ..................................................................................................................................... 155 6.2.Test Graphs ................................................................................................................................... 161 7. Frequency Stability .................................................................................................................................... 240 7.1.Test Result ..................................................................................................................................... 240 8. Duty Cycle .................................................................................................................................................. 244 8.1.Test Result ..................................................................................................................................... 244 8.2.Test Graphs ................................................................................................................................... 247 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 3 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 1. Emission Bandwidth 1.1.Test Result TestMode Antenna Channel 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A-CDD Ant1 5180 23.120 5170.080 5193.200 --- PASS Ant2 5180 19.680 5170.160 5189.840 --- PASS Ant1 5200 28.320 5186.160 5214.480 --- PASS Ant2 5200 31.280 5184.720 5216.000 --- PASS Ant1 5240 33.920 5222.400 5256.320 --- PASS Ant2 5240 35.600 5222.920 5258.520 --- PASS Ant1 5260 35.560 5242.360 5277.920 --- PASS Ant2 5260 35.240 5243.040 5278.280 --- PASS Ant1 5280 33.960 5262.720 5296.680 --- PASS Ant2 5280 36.840 5261.760 5298.600 --- PASS Ant1 5320 20.360 5310.080 5330.440 --- PASS Ant2 5320 20.200 5309.920 5330.120 --- PASS Ant1 5500 20.000 5490.040 5510.040 --- PASS Ant2 5500 20.480 5489.960 5510.440 --- PASS Ant1 5580 20.440 5569.640 5590.080 --- PASS Ant2 5580 27.560 5566.240 5593.800 --- PASS Ant1 5700 19.920 5689.960 5709.880 --- PASS Ant2 5700 19.960 5690.120 5710.080 --- PASS 11N20MIMO Ant1 5180 20.440 5170.000 5190.440 --- PASS Ant2 5180 19.880 5169.920 5189.800 --- PASS Ant1 5200 27.160 5187.080 5214.240 --- PASS Ant2 5200 20.800 5189.520 5210.320 --- PASS Ant1 5240 30.840 5224.880 5255.720 --- PASS Ant2 5240 32.440 5223.640 5256.080 --- PASS Ant1 5260 24.200 5248.080 5272.280 --- PASS Ant2 5260 25.160 5247.760 5272.920 --- PASS Ant1 5280 20.640 5269.680 5290.320 --- PASS Ant2 5280 23.360 5269.240 5292.600 --- PASS Ant1 5320 20.000 5310.040 5330.040 --- PASS Ant2 532…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 84 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC20MIMO_Ant1_5825 11AC20MIMO_Ant2_5825 11AC40MIMO_Ant1_5190 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 85 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant2_5190 11AC40MIMO_Ant1_5230 11AC40MIMO_Ant2_5230 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 86 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant1_5270 11AC40MIMO_Ant2_5270 11AC40MIMO_Ant1_5310 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 87 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant2_5310 11AC40MIMO_Ant1_5510 11AC40MIMO_Ant2_5510 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 88 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant1_5550 11AC40MIMO_Ant2_5550 11AC40MIMO_Ant1_5670 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 89 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant2_5670 11AC40MIMO_Ant1_5755 11AC40MIMO_Ant2_5755 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 90 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC40MIMO_Ant1_5795 11AC40MIMO_Ant2_5795 11AC80MIMO_Ant1_5210 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 91 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC80MIMO_Ant2_5210 11AC80MIMO_Ant1_5290 11AC80MIMO_Ant2_5290 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 92 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC80MIMO_Ant1_5530 11AC80MIMO_Ant2_5530 11AC80MIMO_Ant1_5610 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 93 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11AC80MIMO_Ant2_5610 11AC80MIMO_Ant1_5775 11AC80MIMO_Ant2_5775 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 94 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 95 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 5. Emissions in Restricted Bands 5.1.Test Result Test Mode Ant. Ch Name Channel Detector Freq (MHz) EIRP (dBm) Limit (dBm) Verdict 11A-CDD Ant1 Low 5180 AV 4500.000 -58.96 <=-41.2 PASS AV 5149.275 -47.73 <=-41.2 PASS AV 5150.000 -46.81 <=-41.2 PASS Peak 4500.000 -46.71 <=-21.2 PASS Peak 5149.275 -31.14 <=-21.2 PASS Peak 5150.000 -28.22 <=-21.2 PASS Ant2 Low 5180 AV 4500.000 -59.05 <=-41.2 PASS AV 5149.275 -48.64 <=-41.2 PASS AV 5150.000 -48.09 <=-41.2 PASS Peak 4500.000 -47.23 <=-21.2 PASS Peak 5149.275 -30.42 <=-21.2 PASS Peak 5150.000 -29.03 <=-21.2 PASS total Low 5180 AV 4500.000 -55.99 <=-41.2 PASS AV 5032.609 -41.23 <=-41.2 PASS AV 5149.275 -45.15 <=-41.2 PASS AV 5150.000 -44.39 <=-41.2 PASS Peak 4500.000 -43.95 <=-21.2 PASS Peak 5083.333 -30.71 <=-21.2 PASS Peak 5149.275 -27.75 <=-21.2 PASS Peak 5150.000 -25.60 <=-21.2 PASS Ant1 High 5240 AV 5350.000 -47.27 <=-41.2 PASS AV 5449.217 -45.62 <=-41.2 PASS AV 5460.000 -47.11 <=-41.2 PASS Peak 5350.000 -36.84 <=-21.2 PASS Peak 5452.348 -34.64 <=-21.2 PASS Peak 5460.000 -37 <=-21.2 PASS Ant2 High 5240 AV 5350.000 -47.02 <=-41.2 PASS AV 5448.870 -45.39 <=-41.2 PASS AV 5460.000 -46.96 <=-41.2 PASS Peak 5350.000 -35.41 <=-21.2 PASS Peak 5448.174 -34.46 <=-21.2 PASS Peak 5460.000 -36.95 <=-21.2 PASS total High 5240 AV 5350.000 -44.13 <=-41.2 PASS AV 5447.826 -42.44 <=-41.2 PASS AV 5448.870 -42.49 <=-41.2 PASS AV 5460.000 -44.02 <=-41.2 PASS Peak 5350.000 -33.06 <=-21.2 PASS Peak 5448.174 -31.54 <=-21.2 PASS Peak 5460.000 -33.96 <=-21.2 PASS Ant1 High 5320 AV 5350.000 -44.93 <=-41.2 PASS AV 5350.087 -44.95 <=-41.2 PASS AV 5460.000 -47.69 <=-41.2 PASS Peak 5350.000 -32.18 <=-21.2 PASS Peak 5350.087 -32.13 <=-21.2 PASS Peak 5460.000 -36.89 <=-21.2 PASS Ant2 High 5320 AV 5350.000 -46.07 <=-41.2 PASS AV 5448.638 -45.68 <=-41.2 PASS AV 5460.000 -47.45 <=-41.2 PASS Peak 5350.000 -35.48 <=-21.2 PASS Peak 5399.942 -33.84 <=-21.2 PASS Peak 5460.000 -37.02 <=-21.2 PASS total High 5320 AV 5350.000 -42.45 <=-41.2 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 96 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 AV 5448.638 -42.29 <=-41.2 PASS AV 5460.000 -44.56 <=-41.2 PASS Peak 5350.000 -30.51 <=-21.2 PASS Peak 5399.942 -29.89 <=-21.2 PASS Peak 5460.000 -33.94 <=-21.2 …

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 165 of 286 FCC ID: 2AW68-NM1217C TB-RF-074-1.0 11A-CDD_Ant1_5260_1000~40000 11A-CDD_Ant2_5260_30~1000 11A-CDD_Ant2_5260_1000~40000 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TB-FCC182889 Page: 166 of 286 FCC ID: 2AW68-NM1…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ryan Yan
[email protected]0755-86019782Fax: 0755-86019782

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
1215E5.78 GHz - 5.78 GHz53.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is average conducted. This device supports 2*2 MIMO and supports 802.11a, 802.11n and 802.11ac with a 20 MHz, 40 MHz and 80 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen SDMC Technology Co.,Ltd.

2AW68-B082N03F7

Remote Control

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2AW68-B08001W7

Remote Control

Dec 10, 2025

Equipment Class

DTS - Digital Transmission System
AX3000 Dual Band Wi-Fi GPON Terminal - FCC ID 2AW68-NPE3039GB - Shenzhen SDMC Technology Co.,Ltd.
2AW68-NPE3039GB

AX3000 Dual Band Wi-Fi GPON Terminal

Nov 28, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AX3000 Dual Band Wi-Fi GPON Terminal - FCC ID 2AW68-NP3081GA-V2 - Shenzhen SDMC Technology Co.,Ltd.
2AW68-NP3081GA-V2

AX3000 Dual Band Wi-Fi GPON Terminal

Aug 26, 2024

Equipment Class

DTS - Digital Transmission System
2AW68-DV9187

4K OTT BOX

Aug 08, 2024

Equipment Class

DTS - Digital Transmission System