Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. 2AWNX-SS36
Modeldifferencedeclarationletter DifferencesDescription WeShenzhenApemanInnovationsTechnologyCo.,Ltd.state: ProductïŒSmartOutlet ModelName SS36,SS31,SS32,SS33,SS34,SS35,SS37,SS38, SS39 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsand wiringstructures,Appearanceshape,thematerialsofdecorativeaccessoriesis same,onlydifferentcolor, Signatory Date:05-13-2021 <Signature> NameïŒJackWang TitleïŒManager CompanyïŒShenzhenApemanInnovationsTechnologyCo.,Ltd. Address:1808,HengLuETimesBuilding,No.159,NorthPingji Road,HehuaCommunity,PinghuStreet,Longgang District,Shenzhen,Guangdong,CHINA
C5266091_X8_Ed.1 1/1 Letterof Authorization ShenzhenApemanInnovationsTechnologyCo.,Ltd. Company:ShenzhenApemanInnovationsTechnologyCo.,Ltd. Address:1808,HengLu E TimesBuilding,No.159, NorthPingji Road,HehuaCommunity,PinghuStreet,Longgang District,Shenzhen,Guangdong,CHINA Product Name: Smart Outlet Model Number: SS36,SS31,SS32,SS33,SS34,SS35,SS36ïŒSS37,SS38,SS39 FCC Identifier: 2AWNK-SS36 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name:Jack WangDate: May 13, 2021 Title:Manager Signatureof applicant:
C5266091_X10_Ed.2 1/1 ShenzhenApemanInnovationsTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:May13,2021 Subject:RequestforConfidentiality FCCID: 2AWNK-SS36 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo â BlockDiagram ââ Schematics ââ TestReportNoNo TestSetupPhotosNo â UserâsManual â NOTE 1 â InternalPhotos â NOTE 1 â PartsList/TuneUp ââ RFExposureInfoNoNo OperationalDescription ââ CoverLetter(s)NoNo SDRSoftware/SecurityInfo â No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:JackWang Title:Manager
Page1of3ReportNo.:FCS202104058 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202104058 Photo3 Photo4 Page3of3ReportNo.:FCS202104058 Photo5 Photo6
LabelandLabelLocation FCCID:2AWNK-SS36 L*W:10mm*7mm whitefontonaBlacklabel
Page1of3ReportNo.:FCS202104058 Internalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202104058 Photo3 Photo4 Page 3 of 3ReportNo.:FCS202104058 Photo5 Antenna Photo6 TRL 8722
FCCRFExposure EUTDescription:SmartOutlet ModelNo.:SS36,SS31,SS32,SS33,SS34,SS35,SS37,SS38,SS39 FCCID:2AWNK-SS36 Equipmenttype:PortableDevice 1.TestProcedure AccordingtoKDB447498D01GeneralRFExposureGuidancev06 The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distancesâ€50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/ (min.testseparationdistance,mm)]·[âf(GHz)]â€3.0for1-gSARandâ€7.5for10-gextremity SAR, where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparation distanceisâ€50mmandfortransmissionfrequenciesbetween100MHzand6GHz.Whenthe minimumtestseparationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtest exclusion. 2.TestResultofRFExposureEvaluation Outputpower ïŒdBm/mWïŒ Result calculation SAR Exclusion threshold SAR Test exclusion 802.11b 7.98/6.2805 1.95083.0Yes 802.11g 7.64/5.8076 1.82253.0Yes 802.11n(20MHz) 6.79/4.7753 1.49853.0Yes 802.11n(40MHz) 5.68/3.6983 1.15113.0Yes Conclusion:NoSARisrequired
FCCTestReport ReportNo:FCS202104058W01 Issuedfor Applicant: ShenzhenApemanInnovationsTechnologyCo.,Ltd. Address: 1808,HengLuETimesBuilding,No.159,NorthPingji Road,HehuaCommunity,PinghuStreet,Longgang District,Shenzhen,Guangdong,CHINA ProductName: SmartOutlet BrandName: Teckin ModelName: SS36 SeriesModel: SS31,SS32,SS33,SS34,SS35,SS37,SS38,SS39 FCCID: 2AWNX-SS36 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION ApplicantâsName......................:ShenzhenApemanInnovationsTechnologyCo.,Ltd. Address......................................: 1808,HengLuETimesBuilding,No.159,NorthPingjiRoad, HehuaCommunity,PinghuStreet,LonggangDistrict,Shenzhen, Guangdong,CHINA Manufacture'sName................:ShenzhenApemanInnovationsTechnologyCo.,Ltd. Address......................................: 1808,HengLuETimesBuilding,No.159,NorthPingjiRoad, HehuaCommunity,PinghuStreet,LonggangDistrict,Shenzhen, Guangdong,CHINA ProductDescription ProductName...........................:SmartOutlet ModelName..............................:Teckin SeriesModel..............................:SS36 TestStandards .......................... :SS31,SS32,SS33,SS34,SS35,SS37,SS38,SS39 TestProcedure .......................... :ANSIC63.10-2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetest resultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Andit isapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceService Laboratory,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :25Mar,2021~12May,2021 DateofIssue.................................:12May,2021 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (KaitChen) Page 3 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS6 1.1TESTFACTORY7 1.2MEASUREMENTUNCERTAINTY7 2.GENERALINFORMATION8 2.1GENERALDESCRIPTIONOFTHEEUT8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS11 2.4EQUIPMENTSLIST12 3.6DBBANDWIDTH13 3.1LIMIT13 3.2TESTPROCEDURE13 3.3TESTSETUP13 3.4TESTRESULTS14 4CONDUCTEDOUTPUTPOWER21 4.1LIMIT21 4.2TESTPROCEDURE21 4.3TESTSETUP21 4.5TESTRESULTS21 5.POWERSPECTRALDENSITY22 5.1LIMIT22 5.2TESTPROCEDURE22 5.3TESTSETUP22 5.5TESTRESULTS23 5.6ORIGINALTESTDATA24 6.BANDEDGEANDSPURIOUS(CONDUCTED)30 6.1LIMIT30 6.2TESTPROCEDURE30 6.3TESTSETUP30 6.5TESTRESULTS31 6.5ORIGINALTESTDATA31 7RADIATEDEMISSIONMEASUREMENT43 8CONDUCTEDEMISSIONTEST43 Page 4 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 9.ANTENNAREQUIREMENT61 9.1STANDARDREQUIREMENT61 9.2RESULT61 Page 5 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0021Feb,2021AllInitialIssue Page 6 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 1.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: KDB558074D0115.247MeasGuidancev05r02 FCCPart15.247,SubpartC Standard Section TestItemJudgmentRemark FCC15.247(a)(2)6dBBandwidthPASS-- FCC15.247(b)(3)ConductedOutputPowerPASS-- FCC15.247(e)PowerSpectralDensityPASS-- FCC15.247(d) Band-edgeandSpuriousEmissions (Conducted) PASS-- FCC15.247(d) FCC15.209 FCC15.205 RadiatedSpuriousEmissions PASS-- FCC15.247(d) FCC15.209 FCC15.205 RadiatedBandEdgeCompliance PASS-- FCC15.207 PowerLineConductedEmission PASS-- FCC15.203Antennarequirement PASS-- 15.205RestrictedBandEdgeEmissionPASS-- NOTE: (1)âN/AâdenotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page 7 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumberïŒ5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.988dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±5.2dB 6Allemissions,radiated1GHz-18GHz±4.66dB 7Allemissions,radiated18GHz-40GHz±4.31dB Page 8 of61ReportNo.:FCS202104058W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http:âŠ
Text truncated - open the document above for the full version.
Page 1 of2ReportNo.:FCS202104058 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202104058 Conductionemissiontestingdevice
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 6.28 mW |

LED Video Light or Professional Video Light
Equipment Class
DTS - Digital Transmission System
Baby Monitor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Baby Monitor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Dog Collar Training
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
AX1800 Dual Band Wi-Fi 6 Smart Router
Equipment Class
NII - Unlicensed National Information Infrastructure TX