FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Ustellar Technology Ltd./
  3. 2AWONNTF92

2AWONNTF92Smart LED Flood Light

Shenzhen Ustellar Technology Ltd.
Smart LED Flood Light - FCC ID 2AWONNTF92 - Shenzhen Ustellar Technology Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 07, 2024
Application Purpose
Original Equipment
Date of Application
Jul 07, 2024
Equipment Note
Smart LED Flood Light
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Ustellar Technology Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Page 1 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 7 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13

ID Label/Location Info

Page 1 of 1 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 3.0cm x W 2.0cm) Label Location Smart LED Flood Light Model: NTF92(100W) FCC ID: 2AWONNTF92

Internal Photos

Page 1 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Bluetooth Antenna

RF Exposure Info

Page 1 of 4 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information FCC ID : 2AWONNTF92 EUT : Smart LED Flood Light Test Model : NTF92(100W) Additional Model No. : NTF91(60W) Model Declaration : The PCB board of these models is the same, there are differences in the power and external structure, so only the difference test was carried out. Power Supply : Input: 100-120V~, 50/60Hz, 100W Hardware Version : / Software Version : / Bluetooth : Frequency Range : 2402MHz~2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0 (DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Description : PCB Antenna, 1.08dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Device 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. Page 2 of 4 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna Page 3 of 4 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Internal/External Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Antenna PCB Antenna 2400-2500 MHz 1.08dBi BT Antenna 6. Conducted Power [BT LE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.61 19 2440 -0.02 39 2480 0.54 [BT 2LE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.08 19 2440 -0.68 39 2480 0.33 7. Manufacturing Tolerance BT LE(Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ± (dB) 1.0 1.0 1.0 BT 2LE(Peak) Channel Channel 00 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ± (dB) 1.0 1.0 1.0 Page 4 of 4 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web:…

Text truncated - open the document above for the full version.

Test Report

CBU Antenna test report Product Name: BTU Antenna Type: PCB antenna Writer: Chenlei Maximum Gain:1.08dBi Efficiency:35.73% BTU Antenna test report Version 1.0.0 Date:2021-05-07 NO:0000000001 Antenna Test Report Global Intelligent Platform CBU Antenna test report Content 1. General Description ...................................................................................................................... 3 2. Technical Information ................................................................................................................... 3 3. Test Standards ............................................................................................................................... 3 4. Test Item ........................................................................................................................................ 4 5. Test Photo ...................................................................................................................................... 4 Appendix A Antenna Dimension ....................................................................................................... 5 Appendix B S11/VSWR ................................................................................................................... 5 Appendix C Gain and Efficiency ...................................................................................................... 5 Appendix D Radiation Pattern(1D and 3D) ...................................................................................... 6 Appendix E Test Setup Photo ........................................................................................................... 9 CBU Antenna test report 1. General Description EUT Name BTU Antenna Wireless type BLE Antenna Type PCB antenna Dimensions Appendix A 2. Technical Information Frequency Range 2402MHz~2480MHz Test Frequency 2400,2410......2500MHz 3. Test Standards Identity Document Title IEEE 149-1979 IEEE Standard Test Procedures for Antennas CBU Antenna test report 4. Test Item Report Section Description Appendix B S11/VSWR Appendix C Gain and Efficiency Appendix D Radiation Pattern(1D and 3D) 5. Test Photo Report Section Description Appendix E Test Setup Photo CBU Antenna test report Appendix A Antenna Dimension Appendix B S11/VSWR Frequency (MHz) 2400 2450 2500 Return Loss -11.2 -13.12 -10.1 VSWR 1.8 1.6 1.9 Appendix C Gain and Efficiency Frequency (MHz) Efficiency(%) Gain(dBi) 2400 35.24 1.02 2410 35.73 1.08 CBU Antenna test report 2420 35.24 1.01 2430 34.91 0.81 2440 33.96 0.73 2450 32.14 0.54 2460 32.06 0.65 2470 32.51 0.72 2480 33.96 0.76 2490 33.19 0.67 2500 30.97 0.14 Appendix D Radiation Pattern(1D and 3D) CBU Antenna test report CBU Antenna test report CBU Antenna test report Appendix E Test Setup Photo

Test Report

Page 1 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT LE (Conducted Measurement) Product Name: Smart LED Flood Light Test Model: NTF92(100W) Environmental Conditions Temperature: 23.1 C Relative Humidity: 52.3% ATM Pressure: 100.0 kPa Test Engineer: Paddi Chen Supervised by: Nick Peng Page 2 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.658 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.647 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.655 >=0.5 Pass NVNT BLE 2M 2402 Ant1 1.167 >=0.5 Pass NVNT BLE 2M 2440 Ant1 1.137 >=0.5 Pass NVNT BLE 2M 2480 Ant1 1.132 >=0.5 Pass Page 3 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 -6dB Bandwidth NVNT BLE 2M 2402MHz Ant1 Page 5 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2M 2440MHz Ant1 -6dB Bandwidth NVNT BLE 2M 2480MHz Ant1 Page 6 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.61 30 Pass NVNT BLE 1M 2440 Ant1 -0.02 30 Pass NVNT BLE 1M 2480 Ant1 0.54 30 Pass NVNT BLE 2M 2402 Ant1 0.08 30 Pass NVNT BLE 2M 2440 Ant1 -0.68 30 Pass NVNT BLE 2M 2480 Ant1 0.33 30 Pass Page 7 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 8 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Power NVNT BLE 2M 2402MHz Ant1 Page 9 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2M 2440MHz Ant1 Power NVNT BLE 2M 2480MHz Ant1 Page 10 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -15.9 8 Pass NVNT BLE 1M 2440 Ant1 -17.18 8 Pass NVNT BLE 1M 2480 Ant1 -16.12 8 Pass NVNT BLE 2M 2402 Ant1 -19.68 8 Pass NVNT BLE 2M 2440 Ant1 -20.64 8 Pass NVNT BLE 2M 2480 Ant1 -19.46 8 Pass Page 11 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 12 of 34 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authentici…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 38 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Shenzhen Ustellar Technology Ltd. Smart LED Flood Light Test Model: NTF92(100W) Additional Model No.: NTF91(60W) Prepared for : Shenzhen Ustellar Technology Ltd. Address : 308A,3/F,Building A,Youth Entrepreneur Hub,Jianshe East Road,Qinghua Community, Longhua, Shenzhen China 518000 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 04, 2024 Number of tested samples : 2 Sample No. : B240603030-1, B240603030-2 Serial number : Prototype Date of Test : June 04, 2024 ~ June 07, 2024 Date of Report : June 07, 2024 Page 2 of 38 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA05294183EA Date of Issue ................................... : June 07, 2024 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Shenzhen Ustellar Technology Ltd. Address ........................................... : 308A,3/F,Building A,Youth Entrepreneur Hub,Jianshe East Road,Qinghua Community, Longhua, Shenzhen China 518000 Test Specification Standard.......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Smart LED Flood Light Trade Mark ...................................... : Novostella Test Model ...................................... : NTF92(100W) Ratings ............................................ : Input: 100-120V~, 50/60Hz, 100W Result ............................................ : Positive Compiled by: Supervised by: Approved by: Nadia Zhou/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 38 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : NTF92(100W) EUT......................................... : Smart LED Flood Light Applicant............................... : Shenzhen Ustellar Technology Ltd. Address.................................. : 308A,3/F,Building A,Youth Entrepreneur Hub,Jianshe East Road,Qinghua Community, Longhua, Shenzhen China 518000 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Shenzhen Ustellar Technology Ltd. Address................................... : 308A,3/F,Building A,Youth Entrepreneur Hub,Jianshe East Road,Qinghua Community, Longhua, Shenzhen China 518000 Telephone............................... : / Fax.......................................... : / Factory................................... : Shenzhen Ustellar Technology Ltd. Address................................... : 308A,3/F,Building A,Youth Entrepreneur Hub,Jianshe East Road,Qinghua Community, Longhua, Shenzhen China 518000 Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA05294183EA June 07, 2024 Date of issue Page 4 of 38 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 June 07, 2024 Initial Issue --- Page 5 of 38 FCC ID: 2AWONNTF92 Report No.: LCSA05294183EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shaji…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photo(s) of Conducted Emissions Measurement Fig. 3 Test Setup Photo(s) of Radiated Emissions Measurement Fig. 4 Page 3 of 3 FCC ID: 2AWONNTF92 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Test Setup Photo(s) of Conducted Emissions Measurement Fig. 6

Contact Information

Applicant

li changchun(Power Supervisor)
[email protected]0755-21008194Fax: 0755-21008194

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Ustellar Technology Ltd.

Permanent Outdoor Lights - FCC ID 2AWON-NVS-WF01 - Shenzhen Ustellar Technology Ltd.
2AWON-NVS-WF01

Permanent Outdoor Lights

Jul 24, 2023

Equipment Class

DTS - Digital Transmission System
Smart Flood Light - FCC ID 2AWONNTF81C - Shenzhen Ustellar Technology Ltd.
2AWONNTF81C

Smart Flood Light

May 17, 2023

Equipment Class

DTS - Digital Transmission System
Smart Flood Light - FCC ID 2AWONNTF80C - Shenzhen Ustellar Technology Ltd.
2AWONNTF80C

Smart Flood Light

May 17, 2023

Equipment Class

DTS - Digital Transmission System
Smart Flood Light - FCC ID 2AWONNTF96 - Shenzhen Ustellar Technology Ltd.
2AWONNTF96

Smart Flood Light

Dec 13, 2022

Equipment Class

DTS - Digital Transmission System
Smart Black Light - FCC ID 2AWONNTF90 - Shenzhen Ustellar Technology Ltd.
2AWONNTF90

Smart Black Light

Nov 06, 2022

Equipment Class

DTS - Digital Transmission System