AuVerte AG
Ondur C513 - FCC ID 2AWOQ-003001C513 - AuVerte AG
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 12, 2020
Application Purpose
Original Equipment
Date of Application
Sep 12, 2020
Equipment Note
Ondur C513
Frequency Range
2405.00000000 - 2480.00000000
Company
AuVerte AG
Country
Switzerland

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model: 003001.C513                  FCCSTATEMENT: ThisdevicecomplieswithPart15oftheFCCRules.Operationissubject tothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. Warning:Changesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. NOTE:Thisequipmenthasbeentestedandfoundtocomplywiththe limitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotectionagainst harmfulinterferenceinaresidentialinstallation.Thisequipment generatesusesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguarantee thatinterferencewillnotoccurinaparticularinstallation.Ifthisequipment doescauseharmfulinterferencetoradioortelevisionreception,which canbedeterminedbyturningtheequipmentoffandon,theuseris encouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthatto whichthereceiverisconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. RFwarningstatement: ThedevicehasbeenevaluatedtomeetgeneralRFexposure requirement.Thedevicecanbeusedinportableexposurecondition withoutrestriction.

External Photos

FCCID:2AWOQ-003001C513

ID Label/Location Info

LabelLocationOnEUT Label ProductName:OndurC513 ModelNumber:003001.C513 FCCID:2AWOQ-003001C513 ThisdevicecomplieswithPart15oftheFCCRules.Operation issubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.

Internal Photos

FCCID:2AWOQ-003001C513 ANT

Operational Description

version01 AuVerteAG DeclarationconcerningAntennaSpecification Itisherebydeclaredthattheproduct ModelNo.:003001.C513 FCCID:2AWOQ-003001C513 fulfillstherequirementinFCCtestrelatingtotheantennatype. ThedevicespecifiedaboveconfirmstotheFCCrecommendationsfor internal antennatype(s) describedbelow: ModelNo.ofantenna:003001.C513 Typeofantenna:CeramicAntenna Gainoftheantenna:1dBi Frequencyrange:2405-2480MHz Themountingoftheantennaisfixedtotheradiomoduleandnootherantennashouldbeused. Companyname: AuVerteAG Address:Rothusmatt14,CH-6300Zug,Switzerland City:Zug ZIP/Postalcode: Country:UnitedStates Place:Zug,SwitzerlandDate: 2020-09-03 Signature:

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2AWOQ-003001C513 AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnot required,portabletransmitterswithoutputpowergreaterthantheapplicable lowthresholdrequireSARevaluationtoqualifyforTCBapproval. TestResults:PASS. Channel (MHz) Maxoutput power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance(m m) Calculation results Limit 2405-0.980 ±1 0.02 50.3123 2440-0.655±1 0.345 50.3383 2480-0.757 ±1 0.243 50.3333

Test Report

Report No.: 18220WC00062301FCC ID: 2AWOQ-003001C513Page 1 of 45 Code:AB-RF-05-a FCC TEST REPORT Client Name: AuVerte AG Address: Rothusmatt 14, CH-6300 Zug, Switzerland Product Name: Ondur C513 Date: Sept. 03, 2020 Shenzhen Anbotek Compliance Laboratory Limited Report No.: 18220WC00062301FCC ID: 2AWOQ-003001C513Page 2 of 45 Code:AB-RF-05-a Contents 1. General Information ............................................................................................................................................... 5 1.1. Client Information ....................................................................................................................................... 5 1.2. Description of Device (EUT) ..................................................................................................................... 5 1.3. Auxiliary Equipment Used During Test ................................................................................................... 5 1.4. Description of Test Modes ........................................................................................................................ 6 1.5. List of channels ........................................................................................................................................... 6 1.6. Description Of Test Setup ......................................................................................................................... 7 1.7. Test Equipment List .................................................................................................................................... 7 1.8. Measurement Uncertainty ......................................................................................................................... 9 1.9. Description of Test Facility ........................................................................................................................ 9 2. Summary of Test Results ................................................................................................................................... 10 3. Conducted Emission Test ................................................................................................................................... 11 3.1. Test Standard and Limit .......................................................................................................................... 11 3.2. Test Setup .................................................................................................................................................. 11 3.3. Test Procedure .......................................................................................................................................... 11 3.4. Test Data .................................................................................................................................................... 11 4. Radiation Spurious Emission and Band Edge ................................................................................................ 12 4.1. Test Standard and Limit .......................................................................................................................... 12 4.2. Test Setup .................................................................................................................................................. 12 4.3. Test Procedure .......................................................................................................................................... 13 4.4. Test Data .................................................................................................................................................... 14 5. Output Power Test ............................................................................................................................................... 22 5.1. Test Standard and Limit .......................................................................................................................... 22 5.2. Test Setup .................................................................................................................................................. 22 5.3. Test Procedure .......................................................................................................................................... 22 5.4. Test Data .................................................................................................................................................... 22 6. 6DB Occupy Bandwidth Test ............................................................................................................................. 25 6.1. Test Standard and Limit .......................................................................................................................... 25 6.2. Test Setup .................................................................................................................................................. 25 6.3. Test Procedure .......................................................................................................................................... 25 6.4. Test Data .................................................................................................................................................... 25 7. Power Spectral Density Test .............................................................................................................................. 28 7.1. Test Standard and Limit .......................................................................................................................... 28 7.2. Test Setup .................................................................................................................................................. 28 7.3. Test Procedure .......................................................................................................................................... 28 7.4. Test Data ........................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID::2AWOQ-003001C513 PhotoofRadiationEmissionTest

Contact Information

Applicant

Philipp Roosli(CTO)
[email protected]+1 860 460 7166Fax: N.A.

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from AuVerte AG

2AWOQ-SC801

SC80X

Sep 01, 2024

Equipment Class

DTS - Digital Transmission System
RD1xx Controller - FCC ID 2AWOQ-RD101 - AuVerte AG
2AWOQ-RD101

RD1xx Controller

May 05, 2023

Equipment Class

DTS - Digital Transmission System
Ondur C508 - FCC ID 2AWOQ-003001C508 - AuVerte AG
2AWOQ-003001C508

Ondur C508

Sep 20, 2020

Equipment Class

DTS - Digital Transmission System