FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Robert Bosch GmbH/
  3. 2AWRC-BCM3101

2AWRC-BCM3101eBike ConnectModule

Robert Bosch GmbH

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 19, 2026
Application Purpose
Original Equipment
Equipment Note
eBike ConnectModule
Frequency Range
2402.00000000 - 2480.00000000
Company
Robert Bosch GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; GeschäftsfĂĽhrung: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja RĂĽckert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com eBike Systems Attestation Statements Not Covered Entity and Not Covered Equipment To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 USA Date: January 22, 2026 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2AWRC-BCM3101 Robert Bosch GmbH (FRN: 0029704053), Markwiesenstrasse 58, Reutlingen, Baden-Wuerttemberg, 72770, Germany (“the applicant”) certifies that: a) as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. b) the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely, ________________________________ Signature Dr. Christoph Gahn (EB-CD/GP) Senior Vice President Business Unit Connected Devices Tel: +49 151 14028612 e-mail: [email protected] _______________________________ Signature Sarcevic Dean (EB-CD/PJM) Director - Project Management Business Unit Connected Devices Tel: +49 173 8535690 e-mail: [email protected]

Attestation Statements

eBike Systems Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; GeschäftsfĂĽhrung: Dr. Stefan Hartung, Dr. Christian Fischer, Filiz Albrecht, Dr. Markus Forschner, Dr. Markus Heyn, Dr. Tanja RĂĽckert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: MarkwiesenstraĂźe 58 72770 Kusterdingen Telefon 07121 35-0 www.bosch.com Dr. Christoph Gahn, EB-CD/GP Telephone: +49 151 14028612 [[email protected]] U.S. Agent Designation pursuant to 47 CFR 2.911(d)(7) Robert Bosch GmbH (FRN: 0029704053) acknowledges its consent for the following contact located in the United States to act as its agent for service of process solely for the purposes required by 47 CFR 2.911(d)(7) for the equipment for which authorization is sought (FCC ID: 2AWRC-BCM3101 & CONTAINS FCC ID: XMR2021BG951AGL) Name and company of U.S. agent: Sara Baxenberg, Wiley Rein LLP Physical U.S. address of agent: 2050 M Street, NW, Washington, DC 20036 FRN of U.S. agent: 0035942069 Email address of U.S. agent: [email protected] Wiley Rein LLP (Wiley) is not an agent for service of process for any other purpose. Wiley acknowledges its obligation to accept service of process on behalf of Robert Bosch GmbH as limited above and understands and will reject any service of process for any other purpose. Robert Bosch GmbH acknowledges its obligation to maintain an agent for service of process in the United States pursuant to 47 CFR 2.911(d)(7) for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Sincerely, Robert Bosch GmbH Signature Dr. Christoph Gahn (EB-CD/GP) Senior Vice President Business Unit Connected Devices Signature Sarcevic Dean (EB-CD/PJM) Director Project Management Business Unit Connected Devices Signature Sara Baxenberg Partner Wiley Rein LLP Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 19.01.2026

Cover Letter(s)

1 Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; GeschäftsfĂĽhrung: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja RĂĽckert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com eBike Systems CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 January 22, 2026 Ref: Confidentiality request for FCC ID: 2AWRC-BCM3101 To whom it may concern: Pursuant to paragraphs §0.457(d)(1)(ii) and §0.459 of the Commission’s Rules (47 C.F.R.) and Section §552 (b)(4) of the Freedom of Information Act, Robert Bosch GmbH hereby requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual Short Term Permanent SDR software and security information Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short-term confidentiality is: 45 days from grant date marked Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; GeschäftsfĂĽhrung: Dr. Stefan Hartung, 2 Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja RĂĽckert eBike Systems Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: If you have any questions, please feel free to contact us at the address shown below. Yours sincerely, ____________________ Signature Name: Dr. Christoph Gahn (EB-CD/GP) Title: Senior Vice President Company: Robert Bosch GmbH Markwiesenstrasse 58 72770 Reutlingen, Germany Tel: +49 151 14028612 Fax: +49 7121 35-0 E-mail: [email protected] ___________________________ Signature Name: Sarcevic Dean (EB-CD/PJM) Tirle: Director - Project Management Company: Robert Bosch GmbH Markwiesenstrasse 58 72770 Reutlingen, Germany Tel: +49 173 8535690 E-Mail: [email protected]

RF Exposure Info

© cetecom advanced GmbH Page 1 of 67 TEST REPORT Test Report No.: 1-9708-25-01-12_TR1-R01 Testing Laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Robert Bosch GmbH, Bosch eBike Systems MarkwiesenstraĂźe 58 72770 Reutlingen/GERMANY Contact: Evangelia Mazaraki-Zehnder e-mail: [email protected] Fax: +49 711 811-5187744 Manufacturer Robert Bosch GmbH, Bosch eBike Systems MarkwiesenstraĂźe 58 72770 Reutlingen/GERMANY Test Standards IEC/IEEE 62209-1528-2020 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Part 1528: Human models, instrumentation, and procedures (Frequency range of 4 MHz to 10 GHz) RSS-102 Issue 6 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: e-Bike component Device type: portable device Model name: BCM3101 S/N serial number: 1 / 9 FCC-ID: 2AWRC-BCM3101 ISED Number: 26294-BCM3101 Product Marketing Name (PMN): BCM3101 Hardware Version Identification No. (HVIN): BCM3101 IMEI-Number: 868675060626462 Hardware status: 3.1.0 Software status: Certification App 19.7.2 Firmware status: BG951AGLAAR02A01_15.300.01.300 Frequency: see technical details Antenna: integrated antenna Battery option: Li-ion Battery 3.8V 550mAh Power supply: 13.5V/DC Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: Alexander Hnatovskiy Obada Abo Oun Coordinator Area Testing Manager Radio Labs Regulatory Services Radio Test report no.: 1-9708-25-01-12_TR1-R01 © cetecom advanced GmbH Page 2 of 67 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 4 2.1 Notes and disclaimer .......................................................................................................................... 4 2.2 Application details ............................................................................................................................... 4 2.3 Statement of compliance .................................................................................................................... 4 2.4 Technical details .................................................................................................................................. 5 2.5 Transmitter and Antenna Operating Configurations ....................................................................... 5 3 Test standards/ procedures references ....................................................................................................... 6 3.1 RF exposure limits .............................................................................................................................. 6 4 Reporting statements of conformity – decision rule .................................................................................. 7 5 Summary of Measurement Results .............................................................................................................. 7 5.1 Maximum reported SAR values.......................................................................................................... 8 6 Test Environment ........................................................................................................................................... 8 7 Test Set-up ...................................................................................................................................................... 9 7.1 Measurement system .......................................................................................................................... 9 7.1.1 System Description ..................................................................................................................... 9 7.1.2 Test environment ...................................................................................................................... 10 7.1.3 Probe description ...................................................................................................................... 10 7.1.4 Phantom description ................................................................................................................. 11 7.1.5 Laptop Extension Kit for Device holder .................................................................................... 11 7.1.6 Scanning procedure .................................................................................................................. 12 7.1.7 Spatial Peak SAR Evaluation ................................................................................................... 16 7.1.8 Data Storage and Evaluation .................................................................................................... 18 7.1.9 Tissu…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 65 Annex D Appendix No.: 1-9708-25-01-12_TR1-A201-R01 Testing Laboratory cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://www.cetecomadvanced.com e-mail: [email protected] Accredited Test Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12047-01-00. Appendix with Calibration data, Phantom certificate and system check information 2012-01-16 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 2 of 65 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 Calibration report “Probe EX3DV4” – SN: 3944 ..................................................................................... 3 3 Calibration report “750 MHz System validation dipole” ...................................................................... 13 4 Calibration report “835 MHz System validation dipole” ...................................................................... 23 5 Calibration report “1750 MHz System validation dipole” .................................................................... 34 6 Calibration report “1900 MHz System validation dipole” .................................................................... 41 7 Calibration report “2450 MHz System validation dipole” .................................................................... 51 8 Calibration certificate of Data Acquisition Unit (DAE) – SN: 477 ....................................................... 57 9 Certificate of “SAM Twin Phantom V8.0’’ ............................................................................................. 58 10 Certificate of “ELI Phantom V8.0’’ .................................................................................................. 59 11 Application Note System Performance Check .............................................................................. 60 11.1 Purpose of system performance check ................................................................................. 60 11.2 System Performance check procedure .................................................................................. 60 11.3 Uncertainty Budget ................................................................................................................... 61 11.4 Power set-up for validation ...................................................................................................... 64 11.5 Laboratory reflection ................................................................................................................ 65 11.6 Additional system checks ........................................................................................................ 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 3 of 65 2 Calibration report “Probe EX3DV4” – SN: 3944 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 4 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 5 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 6 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 7 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 8 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 9 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 10 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 11 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 12 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 13 of 65 3 Calibration report “750 MHz System validation dipole” Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 14 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 15 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 16 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 17 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 18 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 19 of 65 Antenna Parameters with Head TSL From cal. data Measured 2024-06-21 Impedance; transformed to feed point 54.5Ω -1.6jΩ 52.7Ω -3.1jΩ Return Loss -26.8dB -27.9dB Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 20 of 65 Antenna Parameters with Head TSL From cal. data Measured 2025-06-06 Impedance; transformed to feed point 54.5Ω -1.6jΩ 53.6Ω -2.4jΩ Return Loss -26.8dB -27.6dB Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 21 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 22 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 23 of 65 4 Calibration report “835 MHz System validation dipole” Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 24 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 25 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 26 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 27 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 28 of 65 Antenna Parameters with Head TSL From cal. data Measured 2024-06-21 Impedance; transformed to feed point 51.0Ω -3.5jΩ 49.7Ω -4.5jΩ Return Loss -28.9dB -26.8dB Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 29 of 65 Antenna Parameters with Head TSL From cal. data Measured 2025-06-05 Impedance; transformed to feed point 51.0Ω -3.5jΩ 51.7Ω -3.5jΩ Return Loss -28.9dB -28.4dB Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 30 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 31 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 32 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 33 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 34 of 65 5 Calibration report “1750 MHz System validation dipole” Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 35 of 65 Test report no.: 1-9708-25-01-12_TR1-A201-R01 Page 36 of 65 Test report no.: 1-9708-25…

Text truncated - open the document above for the full version.

Test Report

eBike Systems Registered Office: Stuttgart, Registration Court: Amtsgericht Stuttgart, HRB 14000; Chairman of the Supervisory Board: Prof. Dr. Stefan Asenkerschbaumer; Managing Directors: Dr. Stefan Hartung, Dr. Christian Fischer, Dr. Markus Forschner, Stefan Grosch, Dr. Markus Heyn, Dr. Frank Meyer, Katja von Raven, Dr. Tanja RĂĽckert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Visitor: MarkwiesenstraĂźe 58 72770 Kusterdingen Phone 07121 35-0 www.bosch.com Antenna Technical Datasheet BCM3101 1. Objective This document contains specification and performance summary of all antennas in BCM3101 device. 2. Antenna Specification BRC3101 includes integrated antennas inside the device mechanics which are fabricated using LDS process on an antenna carrier. 3. Antenna Performance Summary BCM3101 antenna performance was measured in drive unit mounting position as shown in figure 1. Figure 1. Antenna measurement system and coordination. eBike Systems February 16, 2026 Page 2 of 7 3.1. Summary of Total Radiated Efficiency and Peak Gain Band Frequency (MHz) Total Radiated Efficiency (dB) Peak Gain (dBi) BLE 2400 -5.63 0.93 2442 -5.72 0.77 2484 -6.29 0.42 GNSS 1559 -3.82 -0.59 1575.4 -4.16 -0.98 1610 -5.49 -1.85 LTE-M/NB-IoT Band1 Uplink 1920 -5.33 -0.51 1950 -5.20 -0.41 1980 -4.85 -0.49 Downlink 2110 -5.04 1.35 2140 -5.77 0.83 2170 -6.74 -0.15 LTE-M/NB-IoT Band2 Uplink 1850 -6.07 -1.51 1880 -5.82 -0.66 1910 -5.43 -0.44 Downlink 1930 -5.33 -0.75 1960 -5.13 -0.52 1990 -4.84 -0.39 LTE-M/NB-IoT Band3 Uplink 1710 -8.59 -4.09 1747.5 -8.11 -3.58 1785 -7.40 -3.57 Downlink 1805 -6.53 -2.80 1842.5 -6.06 -1.80 1880 -5.85 -0.87 LTE-M/NB-IoT Band4 Uplink 1710 -8.59 -4.12 1732.5 -7.99 -3.47 1755 -8.21 -3.54 Downlink 2110 -5.12 1.26 2132.5 -5.65 0.87 2155 -6.41 0.11 LTE-M/NB-IoT Band5 Uplink 824 -9.48 -5.42 836.5 -9.96 -5.88 849 -10.59 -6.65 Downlink 869 -11.57 -7.26 881.5 -11.97 -7.31 894 -11.59 -7.73 LTE-M/NB-IoT Band8 Uplink 880 -10.77 -6.05 897.5 -10.00 -6.28 915 -8.37 -3.47 Downlink 925 -7.84 -2.38 eBike Systems February 16, 2026 Page 3 of 7 942.5 -7.67 -1.01 960 -7.60 -0.15 LTE-M/NB-IoT Band12 Uplink 699 -7.89 -4.92 707.5 -8.09 -5.27 716 -7.94 -5.15 Downlink 729 -8.00 -5.29 737.5 -8.19 -5.06 746 -8.47 -5.08 LTE-M/NB-IoT Band13 Uplink 777 -9.73 -6.36 782 -9.98 -7.11 787 -10.05 -6.74 Downlink 746 -8.48 -5.10 751 -8.65 -5.17 756 -8.83 -5.21 LTE-M/NB-IoT Band20 Uplink 832 -9.79 -5.72 847 -10.48 -6.54 862 -11.41 -7.26 Downlink 791 -9.57 -6.16 806 -9.14 -5.44 821 -9.38 -5.34 LTE-M/NB-IoT Band28 Uplink 703 -8.00 -5.13 725.5 -7.95 -5.31 748 -8.55 -5.15 Downlink 758 -8.91 -5.23 780.5 -9.92 -6.90 803 -10.36 -6.72 3.2. BLE Antenna 2D Radiation Diagrams Figure 2. BLE Antenna 2D Radiation Diagrams. eBike Systems February 16, 2026 Page 4 of 7 3.3. GNSS Antenna 2D Radiation Diagrams Figure 3. GNSS Antenna 2D Radiation Diagrams. 3.4. LTE-M/NB-IoT Band1 Antenna 2D Radiation Diagrams Figure 4. LTE-M/NB-IoT Band1 Antenna 2D Radiation Diagrams. 3.5. LTE-M/NB-IoT Band2 Antenna 2D Radiation Diagrams Figure 5. LTE-M/NB-IoT Band2 Antenna 2D Radiation Diagrams. eBike Systems February 16, 2026 Page 5 of 7 3.6. LTE-M/NB-IoT Band3 Antenna 2D Radiation Diagrams Figure 6. LTE-M/NB-IoT Band3 Antenna 2D Radiation Diagrams. 3.7. LTE-M/NB-IoT Band4 Antenna 2D Radiation Diagrams Figure 7. LTE-M/NB-IoT Band4 Antenna 2D Radiation Diagrams. 3.8. LTE-M/NB-IoT Band5 Antenna 2D Radiation Diagrams Figure 8. LTE-M/NB-IoT Band5 Antenna 2D Radiation Diagrams. eBike Systems February 16, 2026 Page 6 of 7 3.9. LTE-M/NB-IoT Band8 Antenna 2D Radiation Diagrams Figure 9. LTE-M/NB-IoT Band8 Antenna 2D Radiation Diagrams. 3.10. LTE-M/NB-IoT Band12 Antenna 2D Radiation Diagrams Figure 10. LTE-M/NB-IoT Band12 Antenna 2D Radiation Diagrams. 3.11. LTE-M/NB-IoT Band13 Antenna 2D Radiation Diagrams Figure 11. LTE-M/NB-IoT Band13 Antenna 2D Radiation Diagrams. eBike Systems February 16, 2026 Page 7 of 7 3.12. LTE-M/NB-IoT Band20 Antenna 2D Radiation Diagrams Figure 12. LTE-M/NB-IoT Band20 Antenna 2D Radiation Diagrams. 3.13. LTE-M/NB-IoT Band28 Antenna 2D Radiation Diagrams Figure 13. LTE-M/NB-IoT Band28 Antenna 2D Radiation Diagrams.

Test Report

Conducted test results No.1-9708-25-01-10_TR1-A201-R01 November 27, 2025 Test Standard(s)NA - NI FCC 15.247 - NI FCC 15.247, ISED RSS247 - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Andreas Curette Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 1 of 45 Table of Content NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps3 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps9 FCC 15.247 # Bandwidth 6dB DTS ~ BT LE 1 Msps17 FCC 15.247 # Peak psd DTS ~ BT LE 1 Msps22 FCC 15.247, ISED RSS247 # Bandwidth 99PCT and 20dB ~ BT LE 1 Msps27 FCC 15.247 # TX spurious conducted 20dBc ~ BT LE 1 Msps38 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 2 of 45 NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps References TC start25.11.2025 13:18:53 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version6.0.5.0 Standard | Version NA | NI Method DescriptionPeak OP 3MHz/3MHz - BT LE 1 Msps Information EUT Common Settings BT Low Energy Intermodulation value N 3 Image freq. Low | Mid | High [MHz] 0 | 0 | 0 Power class2 1 Mbps supported True | TXpayload 255 | RXpayload 255 2 Mbps supported False | TXpayload 255 | RXpayload 255 Longrange S8 supported False | TXpayload 255 | RXpayload 255 Longrange S2 supportedFalse | TXpayload 255 | RXpayload 255 Signaling settings WS_USB_RS232 | HCI | 35 | 115200 | None | S1 | None | Off Signaling RF settings RF1com | 0 | 0 | On | User interaction No Equipment Signal analyzer,Rohde&Schwarz,FSV-30,1321.3008K30/103170,3.70 Switch matrix,cetecom advanced GmbH,USM,A001,1.0.0 Test Parameter Technology to testBT LE 1 Msps EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 2402 Frequency mid to testTrue | Freq [MHz] 2440 Frequency high to testTrue | Freq [MHz] 2480 Auto control enabled power supply | Climatic Box No | No Additional path loss [dB]0.7 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/EUT1.GEN1/EUT1.GEN2/ cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 3 of 45 Test Parameter Switch bits 00010001:00010001:00000000:00000001 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 4 of 45 Test at TX 2402 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------6.82dBmINFO Ref. frequency------2402.300MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]16.82 | 9.26 | 25 Start [MHz] | Stop [MHz]2399.500 | 2404.500 RBW [MHz] | VBW [MHz]3.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type1000 | 10 | 1001 | SWE 2399.502400.002400.502401.002401.502402.002402.502403.002403.502404.002404.50 MHz Frequency 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 dBm Magnitude Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power------6.87dBmINFO Peak power------4.864072mWINFO Frequency at peak------2402.2MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 5 of 45 Test at TX 2440 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------7.02dBmINFO Ref. frequency------2440.300MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]17.02 | 9.28 | 25 Start [MHz] | Stop [MHz]2437.500 | 2442.500 RBW [MHz] | VBW [MHz]3.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type1000 | 10 | 1001 | SWE 2437.502438.002438.502439.002439.502440.002440.502441.002441.502442.002442.50 MHz Frequency 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 dBm Magnitude Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power------7.08dBmINFO Peak power------5.10505mWINFO Frequency at peak------2439.79MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 6 of 45 Test at TX 2480 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------7.04dBmINFO Ref. frequency------2480.300MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]17.04 | 9.41 | 25 Start [MHz] | Stop [MHz]2477.500 | 2482.500 RBW [MHz] | VBW [MHz]3.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type1000 | 10 | 1001 | SWE 2477.502478.002478.502479.002479.502480.002480.502481.002481.502482.002482.50 MHz Frequency 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 dBm Magnitude Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power------7.14dBmINFO Peak power------5.176068mWINFO Frequency at peak------2479.69MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 7 of 45 Verdict PASS cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9708-25-01-10_TR1-A201-R01 Release 1 - Page 8 of 45 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps References TC start25.11.2025 13:20:10 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version6.0.5.0 Standard | Version FCC 15.247 | NI MethodDTS: KDB 558074 D01 V05 - Chapter 8.3.1.1 RBW ≥ DTS Bandwidth DescriptionFCC 15.247 Maximum peak output power conducted DTS - BT LE 1 Msps Information EUT Common Settings BT Low Energy Intermodulation value N 3 Image freq. Low | Mid | High […

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Test report no.: 1-9708-25-01-10_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Christoph Gahn(Dr.)
[email protected]Fax: +497121350

Technical Contact

Wiley Rein LLPSara Baxenberg
[email protected]

2050 M Street, NW · Washington, Dist of Columbia, 20036 · United States

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.13 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. This device has been tested touched to the phantom and meets FCC RF exposure guidelines. The highest reported SAR for extremities, body-worn and simultaneous transmission exposure conditions are < 0.1 W/kg, < 0.1 W/kg and 0.662 W/kg, respectively. The SAR evaluation was performed considering co-location with FCC ID: XMR2021BG951AGL

Other Applications from Robert Bosch GmbH

2AWRC-BRC3610

eBike LED controller

Feb 19, 2026

Equipment Class

DTS - Digital Transmission System
2AWRC-BSP3300

Smartphone holder and charger

Nov 26, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2AWRC-BRC3200

e-bike controller

Sep 23, 2024

Equipment Class

DTS - Digital Transmission System
Mini Remote - FCC ID 2AWRC-BRC3300 - Robert Bosch GmbH
2AWRC-BRC3300

Mini Remote

Aug 28, 2022

Equipment Class

JAB - Part 15 Class B Digital Device