Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
eBike Systems Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Dr. Christoph Gahn, EB-CD/GP Telephone: +49 151 14028612 [Christoph. [email protected]] U.S. Agent Designation pursuant to 47 CFR 2.911 (d)(7) Robert Bosch GmbH, with FRN: 0029704053, acknowledges its consent for the following contact located in the United States to act as its agent for service of process solely for the purposes required by 47 CFR 2.911 (d)(7) for the equipment for which authorization is sought (FCC ID: 2AWRC-BRC3200) Name and company of U.S. agent: Scott D. Delacourt, Wiley Rein LLP Physical U.S. address of agent: 2050 M Street, NW, Washington, DC 20036 FRN of U.S. agent0002+5#74r@o35%9/2 q Email address of U.S. agent: [email protected] Wiley Rein LLP (Wiley) is not an agent for service of process for any other purpose. Wiley acknowledges its obligation to accept service of process on behalf of Robert Bosch GmbH as limited above and understands and will reject any service of process for any other purpose. Robert Bosch GmbH acknowledges its obligation to maintain an agent for service of process in the United States pursuant to 47 CFR 2.911(0)(7) for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Sincerely, Robert Bosch GmbH BOSCH Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstra~e 58 72770 Kusterdingen Telefon 07121 35-0 www.bosch.com 22.07.2024 Digitally signed by pki, BOSCH, DE, C, H, i'./.aovoso».Go Date: 2024.07.25 17:10:32 +02'00' Signature Dr. Christoph Gahn (EB-CD/GP) Senior Vice President Business Unit Connected Devices Signature Scott D. Delacourt Partner Wiley Rein LLP 2024.07.30 /I 1A f)07·.45·.43 7 //le aucei +02'00' Signature Sarcevic Dean (EB-CD/PJM) Director - Project Management Business Unit Connected Devices Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, H RB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; Geschaftsfuhrung: Dr. Stefan Hartung, Dr. Christian Fischer, Filiz Albrecht, Dr. Markus Forschner, Dr. Markus Heyn, Dr. Tanja Ruckert
Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; Geschäftsführung: Dr. Stefan Hartung, Dr. Christian Fischer, Filiz Albrecht, Dr. Markus Forschner, Dr. Markus Heyn, Dr. Tanja Rückert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com eBike Systems Attestation Statements Not Covered Entity and Not Covered Equipment To: Federal Communications Commission Date: 12.08.2024 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2AWRC-BRC3200 Robert Bosch GmbH, Markwiesenstrasse 58, Reutlingen, Baden-Wuerttemberg, 72770, Germany (“the applicant”) certifies that: a) as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. b) the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Yours sincerely, ________________________________ Signature Dr. Christoph Gahn (EB-CD/GP) Senior Vice President Business Unit Connected Devices Tel: +49 151 14028612 e-mail: [email protected] _______________________________ Signature Sarcevic Dean (EB-CD/PJM) Director - Project Management Business Unit Connected Devices Tel: +49 173 8535690 e-mail: [email protected]
1 Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; Geschäftsführung: Dr. Stefan Hartung, Dr. Christian Fischer, Filiz Albrecht, Dr. Markus Forschner, Dr. Markus Heyn, Dr. Tanja Rückert Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com eBike Systems CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 12 August 2024 Ref: Confidentiality request for FCC ID: 2AWRC-BRC3200 To whom it may concern: Pursuant to paragraphs §0.457(d)(1)(ii) and §0.459 of the Commission’s Rules (47 C.F.R.) and Section §552 (b)(4) of the Freedom of Information Act, Robert Bosch GmbH hereby requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual Short Term Permanent SDR software and security information Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short-term confidentiality is: 45 days from grant date marked Sitz: Stuttgart, Registergericht: Amtsgericht Stuttgart, HRB 14000; Aufsichtsratsvorsitzender: Prof. Dr. Stefan Asenkerschbaumer; Geschäftsführung: Dr. Stefan Hartung, 2 Dr. Christian Fischer, Filiz Albrecht, Dr. Markus Forschner, Dr. Markus Heyn, Dr. Tanja Rückert eBike Systems Robert Bosch GmbH Postfach 13 42 72703 Reutlingen Germany Besucher: Markwiesenstrasse 58 72770 Reutlingen Tel +49 7121 35-31108 www.bosch.com 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: If you have any questions, please feel free to contact us at the address shown below. Yours sincerely, ____________________ Signature Name: Dr. Christoph Gahn (EB-CD/GP) Title: Senior Vice President Company: Robert Bosch GmbH Markwiesenstrasse 58 72770 Reutlingen, Germany Tel: +49 151 14028612 Fax: +49 7121 35-0 E-mail: [email protected] ___________________________ Signature Name: Sarcevic Dean (EB-CD/PJM) Tirle: Director - Project Management Company: Robert Bosch GmbH Markwiesenstrasse 58 72770 Reutlingen, Germany Tel: +49 173 8535690 E-Mail: [email protected]
© cetecom advanced GmbH Page 1 of 13 TEST REPORT Test report no.: 1-7037-23-01-12_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Robert Bosch GmbH eBike Systems Markwiesenstraße 58 72770 Reutlingen/GERMANY Contact: Evangelia Mazaraki-Zehnder e-mail: [email protected] Phone: +49 162 2487923 Manufacturer Robert Bosch GmbH Tübinger Straße 123 72762 Reutlingen/GERMANY Test Item Kind of test item: e-Bike component Model name: BRC3200 / Kiox 400C FCC ID: 2AWRC-BRC3200 Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® LE This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-7037-23-01-12_TR1-R01 © cetecom advanced GmbH Page 2 of 13 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 2.3 Structure of this Document ................................................................................................................... 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 1 mW Test Exemption ........................................................................................................................... 5 3.2 MPE-Based Test Exemption ................................................................................................................. 5 3.3 SAR-Based Test Exemption .................................................................................................................. 5 3.4 Simultaneous Transmission ............................................................................................................... 6 4 1 mW Test Exemption ...................................................................................................................................... 7 4.1 Detailed Description .............................................................................................................................. 7 4.2 Results ................................................................................................................................................... 7 5 MPE-Based Test Exemption ............................................................................................................................ 8 5.1 Detailed Description .............................................................................................................................. 8 5.2 Results ................................................................................................................................................... 9 6 SAR-Based Test Exemption ........................................................................................................................... 10 6.1 Detailed Description ............................................................................................................................ 10 6.2 Results ................................................................................................................................................. 11 7 Simultaneous Transmission .......................................................................................................................... 12 7.1 Detailed Description ............................................................................................................................ 12 7.2 Result................................................................................................................................................... 13 8 Conclusion ...................................................................................................................................................... 13 Test report no.: 1-7037-23-01-12_TR1-R01 © cetecom advanced GmbH Page 3 of 13 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable for any loss or damage …
Text truncated - open the document above for the full version.
eBike Systems | EB-CD/ENG2 | 2024-09-16 © Robert Bosch GmbH 2024. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. BRC3200 Antenna Design eBike Systems | EB-CD/ENG2 | 2024-09-16 © Robert Bosch GmbH 2024. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. BRC3200 Antenna Design Top side bottomside
Conducted test results No.1-7037-23-01-11_TR1-A201-R1 August 28, 2024 Test Standard(s)FCC 15.247 - NI FCC 15.247, ISED RSS247 - NI NA - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Michael Dorongovski Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 1 of 45 Table of Content FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps3 FCC 15.247 # Bandwidth 6dB DTS ~ BT LE 1 Msps11 FCC 15.247 # Peak psd DTS ~ BT LE 1 Msps16 FCC 15.247, ISED RSS247 # Bandwidth 99PCT and 20dB ~ BT LE 1 Msps21 FCC 15.247 # TX spurious conducted 20dBc ~ BT LE 1 Msps32 NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps40 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 2 of 45 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps References TC start31.07.2024 09:40:07 Ambit temp [°C] | humidity [rel%] 30.3 | 48 System version5.0.7.6 Standard | Version FCC 15.247 | NI MethodDTS: KDB 558074 D01 V05 - Chapter 8.3.1.1 RBW ≥ DTS Bandwidth DescriptionFCC 15.247 Maximum Peak Output Power Conducted DTS - BT LE 1 Msps Information EUT Common Settings BT Low Energy Intermodulation Value N 3 Image Freq. Low | Mid | High [MHz] 0 | 0 | 0 Power Class2 1 Mbps supported True | TXpayload 255 | RXpayload 255 2 Mbps supported False | TXpayload 255 | RXpayload 255 Longrange S8 supported False | TXpayload 255 | RXpayload 255 Longrange S2 supportedFalse | TXpayload 255 | RXpayload 255 Signaling Settings WS_USB_RS232 | HCI | 14 | 115200 | None | S1 | None | On Signaling RF Settings RF1com | 0 | 0 | On | User Interaction No Equipment Signal analyzer,Rohde&Schwarz,FSV-30,1321.3008K30/103170,3.60 Signaling unit BT,Rohde&Schwarz,CMW,1201.0002k75/102550,4.0.190 Switch matrix,cetecom advanced GmbH,USM,A001,1.0.0 Test Parameter Technology to testBT LE 1 Msps EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 2402 Frequency mid to testTrue | Freq [MHz] 2440 Frequency high to testTrue | Freq [MHz] 2480 Auto control enabled power supply | Climatic Box No | No cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 3 of 45 Test Parameter Additional path loss [dB]0.7 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/EUT1.GEN1/EUT1.GEN2/ Switch bits 00010001:00010001:00000000:00000001 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 4 of 45 Test at TX 2402 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. -------1.69dBmINFO Ref. frequency------2402.200MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]3.31 | 8.96 | 10 Start [MHz] | Stop [MHz]2401.000 | 2403.000 RBW [MHz] | VBW [MHz]0.100000 | 0.300000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type50 | 200 | 10001 | SWE DTS bandwidth DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT DTS bandwidth (6dB)------693kHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]8.31 | 8.96 | 15 Start [MHz] | Stop [MHz]2401.000 | 2403.000 RBW [MHz] | VBW [MHz]1.000000 | 5.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type50 | 200 | 1001 | SWE cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 5 of 45 2401.002401.202401.402401.602401.802402.002402.202402.402402.602402.802403.00 MHz Frequency 30.0 25.0 20.0 15.0 10.0 5.0 0.0 -5.0 -10.0 dBm Magnitude Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power---30.00-1.81dBmPASS Peak power---10000.659174mWPASS Frequency at peak------2401.762MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 6 of 45 Test at TX 2440 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. -------1.91dBmINFO Ref. frequency------2440.300MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]3.09 | 9 | 10 Start [MHz] | Stop [MHz]2439.000 | 2441.000 RBW [MHz] | VBW [MHz]0.100000 | 0.300000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type50 | 200 | 10001 | SWE DTS bandwidth DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT DTS bandwidth (6dB)------707kHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]8.09 | 9 | 15 Start [MHz] | Stop [MHz]2439.000 | 2441.000 RBW [MHz] | VBW [MHz]1.000000 | 5.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type50 | 200 | 1001 | SWE cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 7 of 45 2439.002439.202439.402439.602439.802440.002440.202440.402440.602440.802441.00 MHz Frequency 30.0 25.0 20.0 15.0 10.0 5.0 0.0 -5.0 -10.0 dBm Magnitude Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power---30.00-2.12dBmPASS Peak power---10000.613762mWPASS Frequency at peak------2439.758MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7037-23-01-11_TR1-A201-R1 Release 1 - Page 8 of 45 Test at TX 2480 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. -------1.64dBmINFO Ref. frequency------2480.200MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]3.36 | 9.1 | 10 Start [MHz] | Stop [MHz]2479.000 | 2481.000 RBW [MHz] | VBW [MHz]0.100000 | 0.300000 Detector | TraceModePO…
Text truncated - open the document above for the full version.
TEST REPORT Test report no.: 1-7037-23-01-11_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Robert Bosch GmbH eBike Systems Markwiesenstraße 58 72770 Reutlingen/GERMANY Contact: Evangelia Mazaraki-Zehnder e-mail: [email protected] Phone: +49 162 2487923 Manufacturer Robert Bosch GmbH Tübinger Straße 123 72762 Reutlingen/GERMANY Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 247 Issue 3 Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: e-Bike component Model name: BRC3200 / Kiox 400C FCC ID: 2AWRC-BRC3200 ISED certification number: 26294-BRC3200 Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® LE Antenna: Integrated antenna Power supply: 12.5 V to 14.5 V from eBike system Temperature range: -5°C to 40°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: On behalf of Marco Bertolino Andreas Curette Supervisor Radio Services Testing Manager Radio Labs Radio Labs Test report no.: 1-7037-23-01-11_TR1-R01 © cetecom advanced GmbH Page 2 of 40 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Sequence of testing ................................................................................................................................ 7 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ................................................................ 7 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz ............................................................... 8 7.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ................................................................ 9 7.4 Sequence of testing radiated spurious above 18 GHz .................................................................. 10 8 Description of the test setup ................................................................................................................. 11 8.1 Shielded semi anechoic chamber ................................................................................................ 12 8.2 Shielded fully anechoic chamber ................................................................................................ 13 8.3 Radiated measurements > 18 GHz .............................................................................................. 14 8.4 Conducted measurements Bluetooth system .............................................................................. 15 8.5 AC conducted ............................................................................................................................. 16 9 Measurement uncertainty ..................................................................................................................... 17 10 Summary of measurement results ..................................................................................................... 18 11 Additional comments ........................................................................................................................ 19 12 Measurement results ........................................................................................................................ 20 12.1 System gain ............................................................................................................................ 20 12.2 Power spectral density ..................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 660.00 µW |
eBike ConnectModule
Equipment Class
DTS - Digital Transmission SystemeBike LED controller
Equipment Class
DTS - Digital Transmission SystemSmartphone holder and charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Mini Remote
Equipment Class
JAB - Part 15 Class B Digital Device