FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SiMPNiC co., Ltd./
  3. 2AX6X-IRB-01-SW

2AX6X-IRB-01-SWSmart IR Blaster

SiMPNiC co., Ltd.
Smart IR Blaster - FCC ID 2AX6X-IRB-01-SW - SiMPNiC co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 18, 2021
Application Purpose
Original Equipment
Date of Application
May 18, 2021
Equipment Note
Smart IR Blaster
Frequency Range
2412.00000000 - 2462.00000000
Company
SiMPNiC co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual _ 一 Main Function 1. Work with Amazon Alexa/ Echo Dot& Googlehome. 2. Manage your devices via your mobile phone or VoiceControl 3. Intelligent Schedule - Smart IR could create multiple schedules to·turn on/off your electronicsets 4. Leaming Function (DIY) - Control all sets which use lnfraredsignal Function Key and Indicator Description Plug it in. Check the W旧indicatorflashing status. If it is flashing quickly, you can directly connect it with your phone. If it is not, you need to set it to the distribution network mode: Next to the USB power connector, there is a "Reset" button, insert an slim object and pressing about 5-10 seconds until the blue WiFi indicator flashes quickly. Blue indicator flashes slowly means the network connection is abnormal, please check the router or network configuration cola, Black WIFI Standa心. Powe, IEEE 802.11 b/n/g 2.4G Hz 5V DC 1A(Mlc『o USB) Gono�l Remote cont,ol v归MobilePhone App Main Functions Voice cont,ol via Alexa & Google Home Support all home appUance which use lnf...,,ed s;gnal System suppo,t IOS & And�;d OS rnmans;ons 73 ° 73 ° 32mm Weight 44g lnh�d F�quency Physlcal 38-56K Hz lnf,a,ed angle 360 angle lnfraN>d distance I 7m Tempe�tu,e I Ope,at;ng, 32 to104deg,ee Sto�ge, -4 to 149deg,ee Hum;d;ty Opo,at;ng, 10% to90%non七ondons;ng Sto,ago, 5% to 95% non-<,ondonslng Wananty 1-yea, and lndoo, use only Ce.-t;ficaUons FCC &CE -3- Step 1: In homepage. Click··Add Device""一··Others""一··UniversalRemote .. ."". WIFI Ind;cato, 1;ght Power Front side Back side Turn On Intelligence Use your phone to Scan QR code or search "Smart Life" in app market to download and Install the App. Register and log on the account. 105 Android 86·'36'000'33''• •=•m - Add Device ,,; 0 关 文 WelcomeHome . (AddMa� 咄,又i窃<h·�-· :一: Step 2: Let the plug connect with the power supply, _ long press the "Reset" button more than 5 seconds until the blue indicator enters into the fast flash mode. Select "confirm indicator rapidly blinks" _ Add Device 叩 ” , C b } , “ ` z 8 � , . ” “ e · t , K ii 二 � I E::] 会 o i 雯 .一 Step 3: Enter your WI Fi password for your phone and click "Confirm" to enter the page of the search device ^心Device AddO--,e Enter Wi-Fi Password Connecting ... Step 4: Enter the device page, then complete the configuration. Then click "Add remote:•you can see page Select the remote device type. Choose a set you want to control. Use Air conditioner as a sample.Click "Air Conditioner". Search your brand and click it, then you can see the control page. Click Power button and watch if your Air conditioner can turn on/off. If so, click "Can use, this" then you can control your AC by that page. If no, click "I can't use it", then click power button and watch if your set can tum on/off aQain until it's works. """'"'"'"山', 叩< POOM and "'"'°"暴多C比归,..., ..... 一、 12% =•'AOH•• 心•••�o心 卿......... 会 RSH·C-, c心~沁心·-氧 凸........ 巨三一 Step 2: When this page show, you can start DIY. Press the keys you want to learn Step 1: CIiek "DIY" In this page. And CIiek "Next" Step 3: When this page show, it means DIY success. Input the name of the key and confirm Step 4: Then you can Continue to DIY or Save this controller -10- Step 3: Select your country code and Enter your "Smart Life" APP Account and Password, then press the "Link Now" button. Choose "Smart Life". When the Account success to login, press廿记"Authorize"button. 。 J When DIY, please noted three points 1. Makesureared lighton. Youwil lfi ndtheredl ig htwhenyouclosetotheproduct, because the red light inside it (at the back of the bluelight). 2. Make the controller towards the red light. 3. The distance between the controller and the IR no more 6M (if old version. just 3CM) . The closer the better. Too far maybe fall toleam. Step 1: Open the" Amazon Ale x a"APP, make y our Alexa/Echo speaker link to the � iiiiiiii,r. r e s s i t @二二~凸 • � : 立了 心 -.--.�···.,, .• 心I呐, 九,,�,.,,,. 了.. .• ,.,. ""'心,妇..... 一”心旷'"� ·腿 . . _ •a ., • -, .. 正.,可霄妇如心.,.... . , . Step 2: Search the" SmartLife" and choose the first one, then Enable it. -11- Step 4: Back to the menu, and press the "Smart home" button, then choose the "Devices", then press the "Discover" button 1-1 � -1 Step 5: Now you can use your Alexa to control your Smart devices, enjoy yourself When this page show, it means you have linked the Smart Life App to Alexa successful. Come back to Alexa App _ This device comes with a one year warranty from the date of purchase We are always there to help you. Any questions, you can mail or call to us anytime ModeUR02 Name Add,essc Mobile Numbecc Date of pu,chase Invoice Numbecc Slgnatu� Note The follo>Mng situation cannot enjoy my company waccanty commitment -pcoduct was not no=al use -abno,n、elconditions, wet stocage -unauthorized cepal,, misuse, abuse and change -p,oducts of the no,mal wea, and tea,. -beyond the shelf life FCC Warning T his device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this de vice may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to par t 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause h armful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encou…

Text truncated - open the document above for the full version.

Cover Letter(s)

SiMPNiCco.,Ltd. AgentAuthorization Company:SiMPNiCco.,Ltd. Address:16F-6,No.79,Sec1,Xintai5thRd.,XizhiDist.,NewTaipeiCity22101, Taiwan ProductName:SmartIRBlaster TradeMark: ModelNumber(s):IRB-01-SW FCCID:2AX6X-IRB-01-SW WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2021-05-17 Name:LeoLee Title:PMManager Company:SiMPNiCco.,Ltd.

Cover Letter(s)

SiMPNiCco.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-05-17 Subject;RequestforConfidentiality FCCID:2AX6X-IRB-01-SW ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:LeoLee Title:SiMPNiCco.,Ltd.

External Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW EXTERIORPHOTOGRAPHS Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.5 Fig.6

ID Label/Location Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LabelandLocation Size:L:1.1.5cm*W:1.0cm LabelLocation SmartIRBlaster ModelNo.:IRB-01-SW FCCID:2AX6X-IRB-01-SW

Internal Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW INTERIORPHOTOGRAPHS Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.5 Fig.6 WIFIAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.7 Fig.8 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Fig.9 Fig.10

RF Exposure Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 4 FCCRFExposureEvaluation 1.ProductInformation FCCID2AX6X-IRB-01-SW Productname SmartIRBlaster Modelnumber IRB-01-SW Powersupply Input:DC5V,1A ModulationType IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaType PCBAntenna AntennaGain 1.7dBi(Max.) Hardwareversion V1.1 Softwareversion V1.0 FCCOperationfrequency 2412–2462MHz Exposurecategory Generalpopulation/uncontrolledenvironment EUTType ProductionUnit DeviceType MobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthepublic isnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevicewhereby adistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissibleExposure limitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumofthe MPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthecalculated/estimated, numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioofeachantennais determinedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsandexposureconditionsof thehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthetestfrequency.Eitherthe maximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulationsmaybeusedtodeterminethe MPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-field plane-waveequivalentconditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeetthe minimumtestseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 4 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic,and ElectromagneticFields,0Hzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation ArtemisAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequencyband Maximum antennagain Note AntennaPCBAntenna2412MHz-2462MHz1.7dBi2.4GWIFIAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 4 6.ConductedPower ModeChannelFrequency(MHz) PeakConducted OutputPower(dBm) 11B 1241216.36 6243716.72 11246216.49 11G 1241216.14 6243716.77 11246216.66 11N20SISO 1241216.19 6243717.89 11246216.70 7.ManufacturingTolerance 11B(Peak) ChannelChannel1Channel6Channel11 Target(dBm)16.016.016.0 Tolerance±(dB) 1.01.01.0 11G(Peak) ChannelChannel1Channel6Channel11 Target(dBm)16.016.016.0 Tolerance±(dB)1.01.01.0 11N20SISO(Peak) ChannelChannel1Channel6Channel11 Target(dBm)16.017.016.0 Tolerance±(dB)1.01.01.0 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 4 of 4 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromanybodypartof theuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparationdistance,r=20cm,as wellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensitycanbeobtained. [Antenna] Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW IEEE802.11b17.050.11871.70.01471.0000 IEEE802.11g17.050.11871.70.01471.0000 IEEE802.11nHT2018.063.09571.70.01861.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer; 8.2SimultaneousTransmissionMPE 9.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureofmobile device. .......................THEENDOFREPORT.........................

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 1 of 35 Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Smart IR Blaster Trade Mark: Test Model: IRB-01-SW Environmental Conditions Temperature: 24.6  C Relative Humidity:54.1% ATM Pressure:100.0 kPa Test Engineer:Ken He Supervised by:Li Huan A.1 Duty Cycle Test ModeTest ChannelAntDuty Cycle[%]Verdict 11B2437Ant1100PASS 11G2437Ant1100PASS 11N20SISO2437Ant1100PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 2 of 35 Duty Cycle_11B_2437_Ant1 Duty Cycle_11G_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 3 of 35 Duty Cycle_11N20SISO_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 4 of 35 A.2 Maximum Conducted Output Power ModeChannelMeas.Level [dBm]Limit [dBm]Verdict 11B LCH16.3630PASS MCH16.7230PASS HCH16.4930PASS 11G LCH16.1430PASS MCH16.7730PASS HCH16.6630PASS 11N20SISO LCH16.1930PASS MCH17.8930PASS HCH16.7030PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 5 of 35 A.3 Maximum Power Spectral Density ModeChannelMeas.Level [dBm/3KHz]Limit [dBm/3KHz]Verdict 11B LCH-9.1858PASS MCH-9.0148PASS HCH-9.7578PASS 11G LCH-16.3908PASS MCH-16.9218PASS HCH-17.3788PASS 11N20SISO LCH-18.7458PASS MCH-15.7558PASS HCH-16.2728PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 6 of 35 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 7 of 35 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 8 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 9 of 35 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 10 of 35 A.4 6dB Bandwidth ModeChannel6dB Bandwidth [MHz]Limit [MHz]Verdict 11B LCH8.111 ≥0.5 PASS MCH8.096 ≥0.5 PASS HCH8.107 ≥0.5 PASS 11G LCH16.10 ≥0.5 PASS MCH16.31 ≥0.5 PASS HCH16.32 ≥0.5 PASS 11N20SISO LCH16.58 ≥0.5 PASS MCH16.60 ≥0.5 PASS HCH16.62 ≥0.5 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 11 of 35 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 12 of 35 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 13 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 14 of 35 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 15 of 35 A.5 RF Conducted Spurious Emissions ModeChannelPref [dBm]Max. Level [dBm]Limit [dBm] Verdic t 11B LCH5.173-37.647-14.827PASS MCH5.754-38.165-14.246PASS HCH5.28-37.851-14.720PASS 11G LCH-2.556-35.760-22.556PASS MCH-2.182-37.651-22.182PASS HCH-2.57-38.094-22.570PASS 11N20 SISO LCH-2.509-37.880-22.509PASS MCH-1.165-37.382-21.165PASS HCH-2.41-37.954-22.410PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 16 of 35 11B_LCH_Graphs Pref/11B/LCH Puw/11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 17 of 35 11B_MCH_Graphs Pref/11B/MCH Puw/11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 18 of 35 11B_HCH_Graphs Pref/11B/HCH Puw/11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 19 of 35 11G_LCH_Graphs Pref/11G/LCH Puw/11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 20 of 35 11G_MCH_Graphs Pref/11G/MCH Puw/11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 21 of 35 11G_HCH_Graphs Pref/11G/HCH Puw/11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 22 of 35 11N20SISO_LCH_Graphs Pref/11N20SIS O/LCH Puw/11N20 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 23 of 35 11N20SISO_MCH_Graphs Pref/11N20 SISO/MCH Puw/11N20 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 24 of 35 11N20SISO_HCH_Graphs Pref/11N20 SISO/HCH Puw/11N20 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 25 of 35 A.6 Band-edge for RF Conducted Emissions ModeChannelCarrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm]Verdict 11B LCH5.525-48.346-14.48PASS HCH5.328-48.325-14.67PASS 11G LCH-2.451-49.448-22.45PASS HCH-2.211-48.549-22.21PASS 11N20SISO LCH-2.568-49.420-22.57PASS HCH-2.442-48.224-22.44PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 26 of 35 11B/HCH 11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 27 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 28 of 35 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AX6X-IRB-01-SW Report No.: LCS210413100AEA Page 29 of 35 A.7 Restrict-band band-edge measurements Test Mode Test Channel AntFreq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBu V/m] Verdict…

Text truncated - open the document above for the full version.

Test Report

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SWReportNo.:LCS210413100AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 36 FCCTESTREPORT For SiMPNiCco.,Ltd. SmartIRBlaster TestModel:IRB-01-SW Preparedfor:SiMPNiCco.,Ltd. Address:16F-6,No.79,Sec1,Xintai5thRd.,XizhiDist.,NewTaipeiCity22101, Taiwan Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:April16,2021 Numberoftestedsamples:2 Samplenumber:210413100A-1,210413100A-2 Serialnumber:Prototype DateofTest:April16,2021~April26,2021 DateofReport:April28,2021 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SWReportNo.:LCS210413100AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 36 FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo..........................:LCS210413100AEA DateofIssue.........................................:April28,2021 TestingLaboratoryName..................:ShenzhenLCSComplianceTestingLaboratoryLtd. Address.................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure.................:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName................................:SiMPNiCco.,Ltd. Address.................................................:16F-6,No.79,Sec1,Xintai5thRd.,XizhiDist.,NewTaipeiCity22101, Taiwan TestSpecification Standard................................................:FCCCFR47PART15C(15.247) TestReportFormNo..........................:LCSEMC-1.0 TRFOriginator.....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF...........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhenLCS ComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthematerial.ShenzhenLCS ComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresulting fromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. EUTDescription.................................:SmartIRBlaster TradeMark...........................................: TestModel............................................:IRB-01-SW Ratings..................................................:Input:DC5V,1A Result....................................................:Positive Compiledby:Supervisedby:Approvedby: JackLiu/FileadministratorsJinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SWReportNo.:LCS210413100AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of36 FCC--TESTREPORT EUT.........................................:SmartIRBlaster TestModel...............................:IRB-01-SW Applicant...............................:SiMPNiCco.,Ltd. Address..................................:16F-6,No.79,Sec1,Xintai5thRd.,XizhiDist.,NewTaipeiCity22101, Taiwan Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenZhenRiShengHuaTechnologyCo.,Ltd. Address...................................:6/F,BlockB,3rdindustrialArea,JiuWei,XiXiang,BaoAn,ShenZhen, GuangDong,China. Telephone...............................:/ Fax..........................................:/ Factory...................................:/ Address...................................:/ Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS210413100AEA April28,2021 Dateofissue SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SWReportNo.:LCS210413100AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of36 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000 April28,2021 InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SWReportNo.:LCS210413100AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of36 TABLEOFCONTENTS 1.GENERALINFORMATION....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)............................................................................................................................6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS.............................................................................................7 1.3.EXTERNALI/OCABLE...........................................................................................................................................7 1.4.DESCRIPTIONOFTESTFACILITY...........................................................................................................................7 1.5.STATEMENTOFTHEMEASUREMENTUNCERTAINTY.............................................................................................7 1.6.MEASUREMENTUNCERTAINTY..............................................................................................................................8 1.7.DESCRIPTIONOFTESTMODES...............................................................................................................................8 2.TESTMETHODO…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW _______________________________________________________________________________________________ TESTSETUPPHOTOGRAPHS PhotoofRadiatedEmissionsMeasurement Below1GHz Above1GHz SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AX6X-IRB-01-SW _______________________________________________________________________________________________ PowerLineConductedEmission

Contact Information

Applicant

Leo Lee(PM Manager)
[email protected]+886-2-2698-9661Fax: +886-2-2698-3960

Technical Contact

SiMPNiC co., Ltd.
[email protected]

Taiwan

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz62.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from SiMPNiC co., Ltd.

Smart Plug - FCC ID 2AX6X-SPG-US-SW - SiMPNiC co., Ltd.
2AX6X-SPG-US-SW

Smart Plug

May 19, 2021

Equipment Class

DTS - Digital Transmission System
Smart Motion Sensor - FCC ID 2AX6X-PIR-01-SW - SiMPNiC co., Ltd.
2AX6X-PIR-01-SW

Smart Motion Sensor

May 18, 2021

Equipment Class

DTS - Digital Transmission System
Room Keeper - FCC ID 2AX6X-R1 - SiMPNiC co., Ltd.
2AX6X-R1

Room Keeper

Feb 01, 2021

Equipment Class

DTS - Digital Transmission System
Miu Keeper - FCC ID 2AX6X-M1 - SiMPNiC co., Ltd.
2AX6X-M1

Miu Keeper

Jan 10, 2021

Equipment Class

DTS - Digital Transmission System