
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Plumbing Scope Inspection Camera User Manual 8 LED Lights
FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. TESLONG NTS800P D0813 V1.1 3.06.19.000200-02
ShenzhenTeslongTechnologyCo.,Ltd. 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification– EquipmentType Companyname:ShenzhenTeslongTechnologyCo.,Ltd. Address:2ndFloor,Block4, JinhuafaIndustrialPark,Eastof Donghuan2 avenue,Longhua,Shenzhen ProductName:PlumbingScopeInspectionCamera FCC ID :2AXAVNTS8002408 Model(s):NTS800P 2.911(d)(5)(i)EquipmentType We, [ShenzhenTeslongTechnologyCo.,Ltd.] certifythat the equipmentfor whichauthorizationis sought throughcertificationis not: Prohibitedfrom receivingan equipmentauthorizationpursuantto § 2.903;of the FCC rules. Identifiedas an equipmenttype in the “CoveredList ” NOTE1 Yourssincerely, Signature: Name:RichardRenDate:2024.8.29 Title and Companyname:Vice GeneralManager/ShenzhenTeslongTechnologyCo.,Ltd. NOTE1 “CoveredList”; is the List of Equipmentand ServicesCoveredBy Section2 of The SecureNetworksAct, availableat https://www.fcc.gov/supplychain/coveredlist References; 1) 986446D01 CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) FederalRegisterdocument2022-28263publishedon 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhenTeslongTechnologyCo.,Ltd. 2.911(d)(5)(ii)ApplicantAttestationv1.2 Section2.911(d)(5)(ii)Certification– Applicant(CoveredList ) Companyname:ShenzhenTeslongTechnologyCo.,Ltd. Address:2ndFloor,Block4, JinhuafaIndustrialPark,Eastof Donghuan2 avenue,Longhua,Shenzhen ProductName:PlumbingScopeInspectionCamera FCC ID :2AXAVNTS8002408 Model(s):NTS800P 2.911(d)(5)(ii)Applicantfiling We, [ShenzhenTeslongTechnologyCo.,Ltd.] certifythat, as of the date of the filingof the application,the applicantis not identified NOTE1 on the “CoveredList ” NOTE2 , establishedpursuantto § 1.50002of this chapter,as an entityproducingcoveredcommunicationsequipment. Yourssincerely, Signature: Name:RichardRenDate:2024.8.29 Title and Companyname:Vice GeneralManager/ShenzhenTeslongTechnologyCo.,Ltd. NOTE1 Deleteoptionnot applicableto this application. NOTE2 “CoveredList”; is the List of Equipmentand ServicesCoveredBy Section2 of The SecureNetworksAct, availableat https://www.fcc.gov/supplychain/coveredlist References; 1) 986446D01 CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) FederalRegisterdocument2022-28263publishedon 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhenTeslongTechnologyCo.,Ltd. 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:ShenzhenTeslongTechnologyCo.,Ltd. Address:2ndFloor,Block4,JinhuafaIndustrialPark,EastofDonghuan2avenue,Longhua,Shenzhen ProductName:PlumbingScopeInspectionCamera FCCID:2AXAVNTS8002408 Model(s):NTS800P 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ShenzhenTeslongTechnologyCo.,Ltd.](“theapplicant”)designate[ScopeAroundInc.] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. Shenzhen Teslong Technology Co.,Ltd. Applicant Company name:Shenzhen Teslong Technology Co.,Ltd. Address:2nd Floo「 , Block4, Jinhua伯 Industrial Park, East of Donghuan 2 avenue, Longhua,Shenzhen USA Agent Company name: Sco p e Around Inc. Ad dress:17795 SKY PARK CIR STE G IRVINE CA 92614-6133 FRN Number:0033415290 Contact Name:George Wang Telephone No:949-877-7999 Email:george@scopea:round. com NOTE 1: An appli臼ntlocated in the United States may designate itself as the agent for service of proces Signature: Title: General Manager Date: s ::�: ; 二 生 均 FCC Grantee Code: 2AXAV Contact Name: Richard Ren Telephone No: +86-18566655696 Email:[email protected] 叫 2024.8.29 s. Refe「ence;Federal Register document 2022 - 28263 published on 02/06/23 httos://www.federalreaister.aov/documents/2023/02/06/2022-28263/o「otectina-aaainst-national-s ecurit v -th「eats-to-the-c。mmunications-suoolv四chain-throuah-the 2.911 (d)(7)USA Agent v1.5
ShenzhenTeslongTechnologyCo., Ltd. AgentAuthorization Companyname:ShenzhenTeslongTechnologyCo., Ltd. Address:2nd Floor, Block 4, JinhuafaIndustrialPark, East of Donghuan2 avenue, Longhua,Shenzhen ModelNumber(s):NTS800P ProductDescription:PlumbingScope InspectionCamera S WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, to actonourbehalfonallmattersconcerningthecertificationof abovenamed equipment. WedeclarethatMiCOMLabsInc.is allowedto forwardallinformationrelatedto the approvalandcertificationof equipmentto theregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsof ourown. Signature:Date:2024.8.29 Name:RichardRen Title:ViceGeneralManager Company:ShenzhenTeslongTechnologyCo.,Ltd.
ShenzhenTeslongTechnologyCo., Ltd. Office of EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 USA Date: 2024.8.29 Subject;Requestfor Confidentiality FCC ID:2AXAVNTS8002408 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom public disclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The public disclosureof these documents might be harmfulto our companyand would give competitorsan unfair advantagein the market. SchematicDiagram Block Diagram Parts List OperationalDescription Tune-upProcedure SOFTWARESECURITYREQUIREMENTSFOR U-NII DEVICES In additionalto abovementioneddocuments,in order to complywith the marketingregulations in Title 47 CFR §2.803 and the importationrules in Title 47 CFR §2.1204,while ensuringthat businesssensitiveinformationremainsconfidentialuntil the actualmarketingof newly authorizeddevices,we requestShort Term Confidentialityof the followingattachment(s); ExternalPhotos Test Setup Photos InternalPhotos User Manual For 45 days, pursuantto PublicNoticeDA 04-1705. OR For 180 days pursuantto KDB 726920D01. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor public reviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:RichardRen Title: Vice GeneralManager
FCCID:2AXAVNTS8002408 External
3.05.06.000700-01 NTS800P标签/贴背面 42x23mm/合成纸/不干胶/黑底白字/ Plumbing Scope Inspection Camera Model No.: NTS800P Battery3.7V/6000mAh Iithium-ion polymer battery FCC ID: 2AXAVNTS8002408 Not for medical use! Input: 5V 1.5A /9V 1.5A/ 12V 1.2A Label size:42*23mm Label location:
FCCID:2AXAVNTS8002408 Internal
KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. RFExposureEvaluation FCCID:2AXAVNTS8002408 REQUIREMENT KDB447498D01GeneralRFExposureGuidancev06,Clause4.3.1(a) [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)]·[√f(GHz)]≤3.0 Where -f(GHz)istheRFchanneltransmitfrequencyinGHz -PoweranddistanceareroundedtothenearestmWandmmbeforecalculation -Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm,andfortransmission frequenciesbetween100MHzand6GHz.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mm accordingto4.1f)isappliedtodetermineSARtestexclusion. TESTRESULT PassedNotApplicable 2.4GWIFI Test mode Channel Frequency (MHz) Max. Measured Power (dBm) Tuneup tolerance (dBm) Max. Tune up Power (dBm) Maximum Output Power (mW) Calculating data LimitResults 11B 24126.09±17.095.121.5893 3.00Pass 24375.96±16.964.971.5504 24626.12±17.125.151.6169 11G 24125.45±16.454.421.3716 24375.60±16.64.571.4271 24625.77±16.774.751.4917 11N20 SISO 24125.45±16.454.421.3716 24375.49±16.494.461.3914 24625.77±16.774.751.4917 Note: -Themaximumantennagainis0.86dBi. -Theexposuresafetydistanceislessthan5mm. **********************THEEND**********************
深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 承认书 SPECIFICATIONFORAPPROVAL 审批/Approval客户批准/CustomerApproval 制作 PreparedBy 审核 CheckedBy 批准 ApprovalBy 审核 CheckedBy 批准 ApprovalBy 签章 Signature 黄宗宝夏成磊陈华明 日期 Date 2023.12.142023.12.142023.12.14 修订履历/ChangeLog 版本 Version 修订内容 ChangeDescription 责任人 PersoninCharge 核准 ApprovalBy 日期 Date 客户名称 CustomerName 泰视朗 客户项目名Customer ProjectName NTS700 顺达成项目名 SDCProjectName NTS700 整机信息 顺达成料号 SDCP/N WF580B-1131R-125 频段 Band WIFI2.4G 版本号 Version A0 设计人信息/DesignerInformation 射频工程师 RFEngineer 符学荣 研发主管 R&DDiretor 夏承磊 结构工程师 MEEngineer 黄宗宝 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 目录/Catalogue 序号 No. 项目 Item 页码 PageNo. 1 图纸或实物图片 DrawingorProductImage 3/5 2 尺寸测量报告 DimensionsTestReport 4/6 3 射频性能测试报告 RFPerformanceTestReport 7-10 4 可靠性测试报告 ReliabilityTestReport1 11 5 安装事宜或其它 InstallWizardorOther 12 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品图纸或实物图片 DrawingorProductImage 1 S D C V R 5 0 - 2 6 W F 注 : 6 0 m m 以 内 的 线 材 , 若 无 客 户 要 求 则 默 认 端 子 头 朝 下 李 瑶 娜 W F 5 8 0 B - 1 1 3 1 R - 1 2 5 N T S 7 0 0 1 1 2 5 手 撕 位 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 样品尺寸测量报告 SampleDimensionsTestReport 测试日期 TestDate 2023.12.14 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 尺寸编号 DimensionNo. 标准 Standard 样品1 Sample1 样品2 Sample2 样品3 Sample3 Pass/NG ①长度20.98±0.2mm212121.1 Pass ②宽度27.98±0.2mm282828.1 Pass ③厚度0.1±0.03mm0.10.10.1 Pass ④线长125±2mm125126126 Pass 最终结论 Conclusion PASS 测试人&日期 Inspector&Date 许燕芳2023.12.14 批准&日期 Approval&Date 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 射频性能测量报告 RFPerformanceTestReport 天线测试设备简介 AntennaTestEquipmentIntroduction 测试天线输入特性使用AgilentE5071CandAgilent5062A矢量网络分析仪;辐射特性利 用广屏三维近场暗室进行测试,并分别使用8960E5515和AgilentE4438C进行了分析。暗房的测 试坐标如下: TestofantennainputcharacteristicsusingAgilentE5071CandAgilent5062Avectornetwork analyzer;Theradiationpatternoftheantennaaretestedusingtheguangping3DnearfieldAnechoicChamber, andtheinstrumentisusedtoagilent8960E5515andAgilentE4438C.Thetestcoordinatesofthedarkroom areasfollows: 1.S11参数测量/S11Parameter-VSWR 使用一根50Ω同轴电缆连接到天线,然后该电缆连接到网络分析仪测量S11参数,被测量产品远离金属至少 20厘米。 MeasuringMethodisa50Ωcoaxialcableisconnectedtotheantenna.Thenthiscableisconnectedtoanetworkanalyzer tomeasuretheS11parameter,Keepingthisfixtureawayfrommetalatleast20cm. 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 S11Parameter-VSWR 2.天线匹配网络/ AntennaMatchingNetwork 3.Gain&Efficiency 频率(MHZ)240024502500 驻波比 1.321.381.76 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 Frequency(MHz)Efficiency(%)PeakGAIN(dBi) 240041.410.78 245042.720.86 250042.630.83 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 可靠性测试报告 ReliabilityTestReport 测试日期 TestDate 2023.12.14 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 测试项目 TestItem 要求 Requirement 试验设备 testing equipment 样品1 Sample1 样品2 Sample2 样品3 Sample3 判定 PASS/NG 高温存储 在+85°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 低温存储 在-40°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 高温工作 在+60°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 低温工作 在-20°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 盐雾试验 (5士0.5)%氯化钠、 pH值为6.5~7.2,实验 箱温度(35±2)°C □24H☑48H 盐雾试验机OKOKOKPass 连接器铆压拉 拔力 1.13线径≥10N 0.81线径≥8N RG174≥60N RG178≥50N 推拉力计≥8N≥8N≥8NPass 最终结论 Conclusion Pass 测试人&日 期 Inspector& Date 许燕芳2023.12.14 批准&日期 Approval&D ate 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 安装事宜或其它 InstallWizardorOther 安装过程: 取1PCS产品,用手撕下FPC背面的离型纸,然后将FPC定位孔位置与外壳定位孔位置(定位筋 位或定位线)对齐,平整的贴附与外壳上,具体位置如下图所示: 安装过程注意事项: □粘贴天线后保证FPC完整贴附于外壳; □定位孔与外壳定位柱位置对齐; □FPC边缘与外壳边缘对齐; □带端子天线在将端子扣合到主板PCBA端时请首先对齐端子,然后垂直扣合; □拆卸天线端子时需使用工具(如专用撬棍)垂直翘起端子,不可直接拽线拆卸 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址:深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品ROHS证书
Page1 of 82ReportNo.: KS2408S3500E TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo................................:KS2408S3500E FCCID.....................................:2AXAVNTS8002408 Applicant..................................:ShenzhenTeslongTechnologyCo.,Ltd Address....................................: 2nd Floor,Block4, JinhuafaIndustrialPark,East of Donghuan2 avenue, Longhua,Shenzhen Manufacturer...........................:ShenzhenTeslongTechnologyCo.,Ltd Address....................................: 2nd Floor,Block4, JinhuafaIndustrialPark,East of Donghuan2 avenue, Longhua,Shenzhen ProductName ......................... :PlumbingScopeInspectionCamera Model/Typereference ............ :NTS800P Standard..................................:47 CFRPart 15.247 Dateof Receipt.......................:August15 , 2024 Dateof Test Date....................:August15 , 2024to August30, 2024 Dateof issue...........................:August30, 2024 Test result ............................... :Pass Conclusion...............................:The submittedsamplewas foundto COMPLYwith the standardsabove. Preparedby: ( Printedname+ Signature) ChadLin Approvedby: ( Printedname+ Signature) Sky Dong TestingLaboratoryName...:KSIGN(Guangdong)TestingCo., Ltd. Address....................................: WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China Page2 of 82ReportNo.: KS2408S3500E TRF No. RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards.......................................................................................................................................3 1.2. ReportVersion.......................................................................................................................................3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. MeasurementUncertainty......................................................................................................................5 2. GENERALINFORMATION..............................................................................................................................6 2.1. GeneralDescriptionOf EUT ..................................................................................................................6 2.2. AccessoryEquipmentInformation.........................................................................................................6 2.3. Descriptionof Test Modes......................................................................................................................6 2.4. Operationchannellist ............................................................................................................................7 2.5. MeasurementInstrumentsList ...............................................................................................................8 3. EvaluationResults(Evaluation)..................................................................................................................10 3.1. Antennarequirement............................................................................................................................10 4. RadioSpectrumMatterTest Results(RF) ..................................................................................................10 4.1. ConductedEmissionat AC powerline .................................................................................................10 4.2. OccupiedBandwidth............................................................................................................................14 4.3. MaximumConductedOutputPower....................................................................................................16 4.4. PowerSpectralDensity........................................................................................................................17 4.5. Emissionsin non-restrictedfrequencybands......................................................................................18 4.6. Bandedgeemissions(Radiated).........................................................................................................19 4.7. Emissionsin frequencybands(below1GHz)......................................................................................24 4.8. Emissionsin frequencybands(above1GHz)......................................................................................27 5. EUT TEST PHOTOS......................................................................................................................................34 6. PHOTOGRAPHSOF EUT CONSTRUCTIONAL..........................................................................................36 Appendix............................................................................................................................................................37 6.1. AppendixA: DTS Bandwidth................................................................................................................38 6.2. AppendixB: OccupiedChannelBandwidth.....................................................…
Text truncated - open the document above for the full version.
FCCID:2AXAVNTS8002408 ConductedEmissionatACpowerline Emissionsinfrequencybands(below1GHz) Emissionsinfrequencybands(above1GHz) RF
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 4.09 mW |

Digital Borescope
Equipment Class
DTS - Digital Transmission System
Smart inspection camera
Equipment Class
DTS - Digital Transmission SystemBorecam Pro 2.0
Equipment Class
DTS - Digital Transmission System
Digital Borescope
Equipment Class
DTS - Digital Transmission System
Inspection Camera
Equipment Class
DTS - Digital Transmission System