ShenzhenFoxwellTechnologyCo.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date:2020-12-14 Subject; Request for Long Term Confidentiality FCC ID: 2AXCX-T10 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yalin Yang Title: Manager
Shenzhen Foxwell Technology Co., Ltd Agent Authorization Company: Shenzhen Foxwell Technology Co., Ltd Address: 5/F, Plant C, Baocheng 71st Zone, Xin'an Street, Baoan District, Shenzhen, 518106 China Product Name: TPMS SENSOR Model Number(s): T10 Product Description: TPMS SENSOR We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-12-14 Name:Yali Yang Title:Manager Company: Shenzhen Foxwell Technology Co., Ltd
Page 1 of 4 Appendix B: Photographs of EUT Product: TPMS SENSOR Model: T10 External Photos Page 2 of 4 Page 3 of 4 Page 4 of 4
Label Artwork and Location Model: T10 Label: Size: L*W=20*18mm TPMS SENSOR Model: T10 FCC ID: 2AXCX-T10 IC: 26507-T10 Location
Page 1 of 2 Appendix B: Photographs of EUT Product: TPMS SENSOR Model: T10 Internal Photos Antenna Page 2 of 2
RF exposure evaluation According to§2.5.1, systems operating under the provisions of this section shall be operated in a manner that ensures that the device meets the SAR and/or RF field strength limits of RSS-102. Note: For the separation distance ≤ 5mm For f≥ 1.99GHz, The exemption limit is calculated as follow, exemption limit(mW)= -0.6873f 3 + 8.5147f 2 – 34.1288f + 46.613 f is GHz For 0.3≤ f ≤0.835GHz, The exemption limit is calculated as follow, exemption limit(mW)= -90.91f + 92.91 f is GHz So the limit for the common frequency is as follow, Frequency (MHz) 315 433.93 Limit (mW) 64.27 53.46 Result Channel Frequency (MHz) Electric field strength (dBuV/m)@3m ERP (mW) Limit (mW) Result 315 73.25 0.0000254 64.27 PASS 433.93 75.17 0.0000395 53.46 PASS Note: computational formula dBuV/m=20 log uV/m; EIRP= pt *gt =(E *d ) 2 *30; where E is the electric field strength in V/m; d is the measurement distance in meters (m) Result: Because the max tune up power is less than the exemption limit, so No SAR measurement is required.
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID: 2AXCX-T10 Product: TPMS SENSOR Model No.: T10 Additional Model No.: N/A Trade Mark: FOXWELL Report No.: TCT201125E003 Issued Date: Dec. 07, 2020 Issued for: Shenzhen Foxwell Technology Co., Ltd 5/F, Plant C, Baocheng 71st Zone, Xin'an Street, Baoan District, Shenzhen, 518106 China Issued By: Shenzhen Tongce Testing Lab. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China TEL: +86-755-27673339 FAX: +86-755-27673332 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab. This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT201125E003 Page 2 of 29 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. General Information ................................................................................. 6 4.1. Test Environment and Mode ................................................................................. 6 4.2. Description of Support Units ................................................................................ 6 5. Facilities and Accreditations .................................................................. 7 5.1. Facilities ................................................................................................................. 7 5.2. Location ................................................................................................................. 7 5.3. Measurement Uncertainty ..................................................................................... 7 6. Test Results and Measurement Data ..................................................... 8 6.1. Antenna Requirement ........................................................................................... 8 6.2. Conducted Emission ............................................................................................. 9 6.3. Radiated Emission Measurement ...................................................................... 10 6.4. Manually Activated Transmitter ......................................................................... 19 6.5. Occupied Bandwidth ........................................................................................... 21 Appendix A: Photographs of Test Setup Appendix B: Photographs of EUT Report No.: TCT201125E003 Page 3 of 29 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. Test Certification Product: TPMS SENSOR Model No.: T10 Additional Model No.: N/A Trade Mark: FOXWELL Applicant: Shenzhen Foxwell Technology Co., Ltd Address: 5/F, Plant C, Baocheng 71st Zone, Xin'an Street, Baoan District, Shenzhen, 518106 China Manufacturer: Shenzhen Foxwell Technology Co., Ltd Address: 5/F, Plant C, Baocheng 71st Zone, Xin'an Street, Baoan District, Shenzhen, 518106 China Date of Test: Nov. 26, 2020 – Dec. 04, 2020 Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.231 The above equipment has been tested by Shenzhen Tongce Testing Lab. and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date: Dec. 04, 2020 Kevin Huang Reviewed By: Date: Dec. 07, 2020 Beryl Zhao Approved By: Date: Dec. 07, 2020 Tomsin Report No.: TCT201125E003 Page 4 of 29 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. Test Result Summary Requirement CFR 47 Section Result Conduction Emission, 0.15MHz to 30MHz §15.207 N/A Manually Activated Transmitter §15.231(a) PASS Radiation Emission §15.231(b), §15.205, §15.209, §15.35 PASS Occupied Bandwidth §15.231(c) PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Report No.: TCT201125E003 Page 5 of 29 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 3. EUT Description Product: TPMS SENSOR Model No.: T10 Additional Model No.: N/A Trade Mark: FOXWELL Operation Frequency: 315MHz, 433.93MHz Modulation Technology: FSK Antenna Type: Internal Antenna Antenna Gain: 0dBi Power Supply: DC 3V Note: The antenna gain listed in this report is provided by applicant, and the test laboratory is not responsible for this parameter. Report No.: TCT201125E003 Page 6 of 29 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 4. General Information 4.1. Test Environment and Mode Operating Environment: Temperature: 25.0 C Humidity: 55 % RH Atmospheric Pressure: 1010 mbar Test Mode: Operation mode: Keep the EUT in continuous transmitting with modulation The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,…
Text truncated - open the document above for the full version.
Page 1 of 1 Appendix A: Photographs of Test Setup Product: TPMS SENSOR Model: T10 Radiated Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15.231 | 315 MHz - 315 MHz | - |

Multi-System Tablet Scanner
Equipment Class
DTS - Digital Transmission System
Automotive Diagnostic System
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BATTERY TESTER
Equipment Class
DTS - Digital Transmission System
TPMS Service Tool (WiFi Version)
Equipment Class
DTS - Digital Transmission System
AUTOMOTIVE DIAGNOSTIC PLATFORM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter