Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Guide Kasa Smart Wi-Fi Light Switch, Motion-Activated KS200M © 2021 TP-Link 1910013011 REV1.0.0 Contents About This Guide ····················································1 Introduction ·······························································2 Set Up Your Smart Light Switch ·····················4 Main Device Controls ···········································5 Set Schedules ··························································6 Set Timer ·····································································8 Set Away Mode ························································9 Check Runtime·······················································10 Manage Device Settings ··································11 Reset Your Smart Light Switch ······················12 Create Scenes························································15 Smart Actions ·························································17 Discover Kasa ·························································28 1 About This Guide This guide provides a brief introduction to Kasa Smart Wi-Fi Light Switch and the Kasa app, as well as regulatory information. Please note that features of Kasa Smart Wi-Fi Light Switch may vary slightly depending on the model and software version you have, and on your location, language and internet service provider. All images, steps, and descriptions in this guide are only examples and may not reflect your actual experience. Conventions In this guide, the following convention is used: Convention Description Teal Key information appears in teal, including management page text such as menus, items, buttons and so on. Underline Hyperlinks are in teal and underlined. You can click to redirect to a website. More Info • Specifications can be found on the product page at https://www.tp-link.com. • Our Technical Support and troubleshooting information can be found at https://www.tp-link.com/support. 2 Introduction TP-Link Smart Wi-Fi Light Switch is a standard wall light switch that can be controlled via your iOS or Android devices. Built-in motion and ambient light sensors work together to realize hands-free control. Kasa smart switch automatically turns your lights on and off, saving you effort and electricity bills. Create smart modes to customize your light settings to follow your routine with the easy-to-use app. Just set it then forget it. The Kasa Smart app also provides easy step-by-step installation instructions and convenient remote control from anywhere, anytime. • Advanced Sensing - The equipped sensors detect motion and ambient lighting so your lights only trigger on at night. • Smart Modes - Set different light triggers based on your routine for effortless control. • Easy Installtion - The detailed in-app guide and unique circuit design make installation simple. • Energy Saving - Turn off the light automatically after you leave the room for a set time. • Remote Control - Control anything connected to your smart light switch, like lights, ceiling fans or other fixtures, from anywhere using the Kasa Smart app. • No Hub Required - Connect to your existing Wi-Fi router. • Away Mode - Set your smart light switch to turn connected fixtures on and off at random intervals to give the appearance you're home even while you're away. • Scheduling - Set lights to automatically turn on and off throughout the day or night whether you’re home or away. • Voice Control - Use Alexa, Google Assistant, or Microsoft Cortana to control your devices with voice commands. 3 Appearance The Smart Switch is compatible with incandescent, LED, Halogen, and compact fluorescent light bulbs. The switch also includes a white backlight LED indicator to easily locate the switch at night. See the explanation below: Flashing amber & green: Ready for setup. Solid amber: Your phone is connected to the switch. Flashing green: Connecting to Wi-Fi. Stay green for 30s: Connected to Wi-Fi. Solid red: Disconnected from Wi-Fi. Flashing amber: The switch is being reset to factory default settings. White: Light fixture is off. Press to reboot the Smart Switch. Press and hold for about 5 seconds to initiate the setup mode with configuration settings saved. Press and hold for about 10 seconds to factory reset the Switch. RESET RESTART 4 Set Up Your Smart Light Switch Follow the steps below to set up your Smart Power Strip via Kasa Smart app. 1. Download and install Kasa app Go to Google Play or the Apple App Store or scan the QR code below to download the Kasa app on your Android or iOS smartphone or tablet. 2. Log in or sign up with TP-Link ID Open the app. Use your TP-Link ID to log in. If you don’t have a TP-Link ID, tap Create Account and the Kasa app will guide you through the rest. 3. Add Device Tap the + button in the Kasa app, select Smart Switches and then follow step-by-step app instructions to complete the installation and setup. 5 Main Device Controls After you successfully set up your Smart Light Switch, you will see the home page of the Kasa Smart app. Here you can view and manage all devices that you've added to Kasa. Tap your smart switch to control and manage it. Home Page You can see all your Kasa devices listed in the Home page. Turn on/off the smart outlet Turn on/off any outlet of your Smart Light Switch quickly by tapping the switch on the home page. Tapping in the device, you can also check or change its status. 6 Set Schedules Schedule: Set schedules to automatically turn on/off the light at set times according to your daily routine. 1. Tap your Smart Light Switch in the Home page, and then tap . 2. Tap + on the top right corner.2. Set a schedule to turn the light on or off. For example, I want to turn off the light at 11:00 PM every day. 7 4. You can also choose to turn on/off the light at Sunrise or Sunset. Please note that the Sunrise and Sunset times are based your location. 5. Tap Save and you'll see your schedule listed in the Schedule Page. You can add more schedules following the same st…
Text truncated - open the document above for the full version.
TP-Link Corporation Limited 053019 – 12 Authority to Act as Agent Date: March 29, 2021 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: UL Verification Services (Guangzhou) Co., Ltd., Song Shan Lake Branch is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____2021/03/29_____ By: __________________________ ______ Abby Liang __________________ (Signature 1 ) (Print name) Title: _____ Regulatory Compliance Manager __ On behalf of: ___ TP-Link Corporation Limited (Company Name) Telephone: _____00852-37585503 __________ THIS MUST BE SIGNED BY THE APPLICANT/AGENT AND SHOULD BE PLACED ON APPROPRIATE LETTERHEAD 053019 – 12 Request for Confidentiality Date: March 29, 2021 Subject: Confidentiality Request for: ____2AXJ4KS200M _____ Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent Block Diagrams ☐ Short Term External Photos ☐ Short Term ☐ Permanent * 2 Internal Photos ☐ Short Term ☒ Permanent Operation Description/Theory of Operation ☐ Short Term ☐ Permanent Parts List & Placement/BOM ☐ Short Term ☐ Permanent Tune-Up Procedure ☐ Short Term ☒ Permanent Schematics ☐ Short Term Test Setup Photos ☐ Short Term ☐ Permanent * 3 User’s Manual TP-Link Corporation Limited has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: __________________________ _____ Abby Liang____ (Signature/Title 4 ) (Print name) 2 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details.
TP-Link Corporation Limited Wi-Fi Channel 12 and 13 Declaration Letter Date: 2021-03-29 We, the undersigned company Company Name: TP-Link Corporation Limited Address: Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon, Hong Kong Declare that: Product description: Kasa Smart Wi-Fi Light Switch, Motion-Activated Type designation: KS200M Brand: tp-link FCC ID: 2AXJ4KS200M Only channels 1~11 will be used in USA. Country code selection is disabled. If you have any questions regarding the authorization, please do not hesitate to contact us, thank you~ Sincerely, Signature: ________________________ Name: Abby Liang Tel: 00852-37585503 Email: [email protected]
Appendix I External Photographs Page 2 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. View of EUT-1 View of EUT-2 Page 3 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. View of EUT-3 View of EUT-4
C B A 12 C 345678 B E D D A 9 料号: 12345 E 6789 KS200M(US)_1.0_产品规格标贴 A1 50#网纹胶亮白PET+雾膜 白盾-128 KS200M(US)_1.0 陈博博 2020-12-16 尺寸:38.5*56.5±0.2mm, 4.8 R,1R PANTONE 877C 白色、PANTONE Cool Gray 2U、PANTONE429C 黑色、白色、PANTONE 877C 尺寸图文字转曲(供应商来料效果图) 条形码由“xxxxxxxxxxxx”生成 Kasa Smart Wi-Fi Light Switch, Motion-Activated Model: KS200M IC: 26583-KS200MFCC ID: 2AXJ4KS200M Model:KS200M(US) Ver:1.0 S/N:XXXXXXXXXXXXX Rating: 120V~ 60Hz 15A General Use 5A Incandescent 实际效果图 注:序列号由工厂直接打印在锡标上(以 上条码仅为示意)。 4.8R 1R UL1.0
Appendix II Internal Photographs Page 2 of 4 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-1 Internal View of EUT-2 Page 3 of 4 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-3 Internal View of EUT-4 Module Antenna Page 4 of 4 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-5
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Kasa Smart Wi-Fi Light Switch, Motion-Activated MODEL NUMBER: KS200M FCC ID: 2AXJ4KS200M REPORT NUMBER: 4789841897-4 ISSUE DATE: March 24, 2021 Prepared for TP-Link Corporation Limited Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon, Hong Kong Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi-Tech Development Zone, Dongguan, People’s Republic of China Tel: +86 769-22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT No.: 4789841897-4 Page 2 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS .................................................................................... 3 2. TEST METHODOLOGY ........................................................................................................ 4 3. FACILITIES AND ACCREDITATION .................................................................................... 4 4. REQUIREMENT .................................................................................................................... 5 REPORT No.: 4789841897-4 Page 3 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: TP-Link Corporation Limited Address: Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon, Hong Kong Manufacturer Information Company Name: TP-Link Corporation Limited Address: Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon, Hong Kong EUT Information EUT Name: Kasa Smart Wi-Fi Light Switch, Motion-Activated Model: KS200M Brand Name: tp-link Sample Status: Normal Sample ID: 3698111 Sample Received Date: March 01, 2021 Date of Tested: March 01, 2021~ March 23, 2021 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47CFR§2.1091 KDB-447498 D01 V06 PASS Prepared By: Checked By: Kebo Zhang Shawn Wen Project Engineer Laboratory Leader Approved By: Stephen Guo Laboratory Manager REPORT No.: 4789841897-4 Page 4 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with KDB 447498 D01 General RF Exposure Guidance v06. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Delcaration of Conformity (DoC) and Certification rules ISED(Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with Industry Canada. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber D, the VCCI registration No. is G-20019 and R-20004 Shielding Room B , the VCCI registration No. is C-20012 and T-20011 Note 1: All tests measurement facilities use to collect the measurement data are located at Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone, Dongguan, 523808, China Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30MHz had been correlated to measurements performed on an OFS. REPORT No.: 4789841897-4 Page 5 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/150 30 1500-100,000 -- -- 1.0 30 Note 1: f = frequency in MHz, * means Plane-wave equivalent power density Note 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not b…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-247 ISSUE 2 CERTIFICATION TEST REPORT For Kasa Smart Wi-Fi Light Switch, Motion-Activated MODEL NUMBER: KS200M FCC ID: 2AXJ4KS200M IC: 26583-KS200M HIVN: KS200M REPORT NUMBER: 4789841897-2 ISSUE DATE: March 24, 2021 Prepared for TP-Link Corporation Limited Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon, Hong Kong Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi- Tech Development Zone Dongguan, 523808, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4789841897-2 Page 2 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 03/24/2021 Initial Issue REPORT NO.: 4789841897-2 Page 3 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Clause Test Items FCC/ISED Rules Test Results 1 6dB Bandwidth and 99% Occupied Bandwidth FCC Part 15.247 (a) (2) RSS-247 Clause 5.2 (a) ISED RSS-Gen Clause 6.7 Pass 2 Conducted Output Power FCC Part 15.247 (b) (3) RSS-247 Clause 5.4 (d) Pass 3 Power Spectral Density FCC Part 15.247 (e) RSS-247 Clause 5.2 (b) Pass 4 Conducted Bandedge and Spurious Emission FCC Part 15.247 (d) RSS-247 Clause 5.5 Pass 5 Radiated Bandedge and Spurious Emission FCC Part 15.247 (d) FCC Part 15.209 FCC Part 15.205 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Pass 6 Conducted Emission Test for AC Power Port FCC Part 15.207 RSS-GEN Clause 8.8 Pass 7 Antenna Requirement FCC Part 15.203 RSS-GEN Clause 6.8 Pass Note: 1.This test report is only published to and used by the applicant, and it is not for evidence purpose in China. 2. The measurement result for the sample received is <Pass> according to < CFR 47 FCC PART 15 SUBPART C >< ISED RSS-247 > when <Accuracy Method> decision rule is applied. REPORT NO.: 4789841897-2 Page 4 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 6 2. TEST METHODOLOGY ..................................................................................................... 7 3. FACILITIES AND ACCREDITATION ................................................................................. 7 4. CALIBRATION AND UNCERTAINTY ................................................................................ 8 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................... 8 5. EQUIPMENT UNDER TEST ............................................................................................... 9 5.1. DESCRIPTION OF EUT .............................................................................................. 9 5.2. CHANNEL LIST ........................................................................................................... 9 5.3. MAXIMUM OUTPUT POWER...................................................................................... 9 5.4. TEST CHANNEL CONFIGURATION ..........................................................................10 5.5. THE WORSE CASE POWER SETTING PARAMETER ..............................................10 5.6. THE WORSE CASE CONFIGURATIONS ..................................................................10 5.7. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................11 5.8. DESCRIPTION OF TEST SETUP ...............................................................................12 6. MEASURING INSTRUMENT AND SOFTWARE USED ....................................................13 7. ANTENNA PORT TEST RESULTS ...................................................................................15 7.1. ON TIME AND DUTY CYCLE .....................................................................................15 7.2. 6 dB DTS BANDWIDTH AND 99 % OCCUPIED BANDWIDTH ..................................16 7.3. CONDUCTED OUTPUT POWER ...............................................................................18 7.4. POWER SPECTRAL DENSITY ..................................................................................19 7.5. CONDUCTED BANDEDGE AND SPURIOUS EMISSIONS ........................................21 8. RADIATED TEST RESULTS .............................................................................................23 8.1. RESTRICTED BANDEDGE ........................................................................................29 8.1.1. 802.11b MODE ....................................................................................................29 8.1.1. 802.11g MODE ....................................................................................................37 8.1.2. 802.11n HT20 MODE ................................................…
Text truncated - open the document above for the full version.
REPORT NO.: 4789841897-2 Page 112 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11B_Ant1_2457 11B_Ant1_2462 11G_Ant1_2412 REPORT NO.: 4789841897-2 Page 113 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11G_Ant1_2417 11G_Ant1_2437 11G_Ant1_2457 REPORT NO.: 4789841897-2 Page 114 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2417 REPORT NO.: 4789841897-2 Page 115 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20SISO_Ant1_2437 11N20SISO_Ant1_2457 11N20SISO_Ant1_2462 REPORT NO.: 4789841897-2 Page 116 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11.3. Appendix C: Maximum AVG conducted output power 11.3.1. Test Result Test Mode Antenna Channel conducted output power Result[dBm] EIRP Result[dBm] Limit[dBm] Verdict 11B Ant1 2412 21.03 24.03 <=30 PASS 2417 21.69 24.69 <=30 PASS 2437 22.15 25.15 <=30 PASS 2457 21.17 24.17 <=30 PASS 2462 20.59 23.59 <=30 PASS 11G Ant1 2412 17.16 20.16 <=30 PASS 2417 19.85 22.85 <=30 PASS 2437 19.87 22.87 <=30 PASS 2457 18.72 21.72 <=30 PASS 2462 16.46 19.46 <=30 PASS 11N20SISO Ant1 2412 16.87 19.87 <=30 PASS 2417 19.38 22.38 <=30 PASS 2437 19.84 22.84 <=30 PASS 2457 18.26 21.26 <=30 PASS 2462 15.98 18.98 <=30 PASS REPORT NO.: 4789841897-2 Page 117 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11.4. Appendix D: Maximum power spectral density 11.4.1. Test Result Test Mode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict 11B Ant1 2412 -0.95 <=8 PASS 2417 0.91 <=8 PASS 2437 0.22 <=8 PASS 2457 -0.14 <=8 PASS 2462 -0.99 <=8 PASS 11G Ant1 2412 -8.41 <=8 PASS 2417 -6.08 <=8 PASS 2437 -4.72 <=8 PASS 2457 -6.66 <=8 PASS 2462 -9.03 <=8 PASS 11N20SISO Ant1 2412 -7.73 <=8 PASS 2417 -5.39 <=8 PASS 2437 -5.24 <=8 PASS 2457 -7.54 <=8 PASS 2462 -9.29 <=8 PASS REPORT NO.: 4789841897-2 Page 118 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11.4.2. Test Graphs 11B_Ant1_2412 11B_Ant1_2417 11B_Ant1_2437 REPORT NO.: 4789841897-2 Page 119 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11B_Ant1_2457 11B_Ant1_2462 11G_Ant1_2412 REPORT NO.: 4789841897-2 Page 120 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11G_Ant1_2417 11G_Ant1_2437 11G_Ant1_2457 REPORT NO.: 4789841897-2 Page 121 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2417 REPORT NO.: 4789841897-2 Page 122 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20SISO_Ant1_2437 11N20SISO_Ant1_2457 11N20SISO_Ant1_2462 REPORT NO.: 4789841897-2 Page 123 of 145 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No: 10-SL-F0088 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11.5. Appendix E: Band edge measurements 11.5.1. Test Result Test Mode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict 11B Ant1 Low 2412 12.10 -29.9 <=-17.9 PASS 2417 12.81 -37.22 <=-17.19 PASS High 2457 11.78…
Text truncated - open the document above for the full version.
Building 10, Innovation Technology Park, No. 1, · Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 164.00 mW |
AXE3000 Wi-Fi 6E High Gain Wireless USB Adapter
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AX3000 Wi-Fi 6 Air Range Extender
Equipment Class
DTS - Digital Transmission System
5GHz 300Mbps Long-range Indoor/Outdoor Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AX3000 Whole Home Mesh Wi-Fi AP
Equipment Class
NII - Unlicensed National Information Infrastructure TX
5GHz 867Mbps Long-range Indoor/Outdoor Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX