Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Attestation Statements (September 05,2024) TO:Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (GC: 2AXYP) (ORAIMO TECHNOLOGY LIMITED), the undersigned, hereby authorize Lucky Cowboy Global Services, LLCto act as our designated U.S. agent for service of process, (ORAIMO TECHNOLOGY LIMITED)accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Lucky Cowboy Global Services, LLCaccepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: ORAIMO TECHNOLOGY LIMITED Contact Name: Greeny Xian Address:FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG FRN:0030126577 Telephone No:15814421443 Email: [email protected] Signature [Greeny Xian] U.S. Agent Information: Company Name: Lucky Cowboy Global Services, LLC Address: 2213 S. Braeswood Blvd. #12E Houston, TX 77030 USA FRN: 0033510934 Contact Name: Louie Liu Telephone No: +1 (713) 992-3369 Email: [email protected] Signature [Louie Liu]
(ORAIMOTECHNOLOGYLIMITED) ( April28,2024 ) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(ii)requestfor(2AXYP-OTW-625-L#) [ORAIMOTECHNOLOGYLIMITED](“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredListasanentity producing“covered”equipment. Sincerely, GreenyXian/Manager (ORAIMOTECHNOLOGYLIMITED) ( April28,2024 ) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(i)requestfor(2AXYP-OTW-625-L#) [ORAIMOTECHNOLOGYLIMITED](“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Sincerely, GreenyXian/Manager
ORAIMOTECHNOLOGYLIMITED AgentAuthorizationLetter (September12,2024) EurofinsMETLabs 914WestPatapscoAvenue Baltimore,MD21230 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorize (WORLDSTANDARDIZATIONCERTIFICATION& TESTINGGROUP(SHENZHEN)CO.,LTD.)toactonourbehalfinallmattersrelatingto applicationforequipmentauthorization,includingthesigningofalldocuments relatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderis subjecttothedenialofbenefits,includingFCCbenefits,pursuanttoSection5301 oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, GreenyXian/Manager
ORAIMOTECHNOLOGYLIMITED LongTermConfidentialityRequestLetter (April28,2024) EurofinsMETLabs 914WestPatapscoAvenue Baltimore,MD21230 RE:CONFIDENTIALITYREQUESTFOR(TrueWirelessEarbuds/OTW-625#2AXYP-OTW-625-L#) ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459of CFR47.Wehaverequestedthatthe -BlockDiagram -Schematics -OperationalDescription requiredtobesubmittedwiththisapplicationbepermanentlywithheldfrompublicreview. Theabove-mentioneddocumentsbelongtointernaldocuments,isourproprietaryinformation,that couldnevergetintothepossessionofourcompetition. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, Client’sname/Title:GreenyXian/Manager CompanyName:ORAIMOTECHNOLOGYLIMITED Contactinformation/address:[email protected]/FLATN16/FBLOCKBUNIVERSAL INDUSTRIALCENTRE19-25SHANMEISTREETFOTANNTHONGKONG
ORAIMOTECHNOLOGYLIMITED ShortTermConfidentialityRequestLetter (April28,2024) METLaboratories,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:ShortTermConfidentialityRequestFor(TrueWirelessEarbuds/OTW-625# 2AXYP-OTW-625-L#) ToWhomItMayConcern: Inaccordancewithsections0.457and0.459ofCFR47,< ORAIMOTECHNOLOGYLIMITED >. requestsshort-termConfidentialityoffollowingsectionsofthisapplicationforaperiodof180 daysaftergrantisissued. Testsetupphotos Externalphotos Internalphotos User’smanual Thesedocumentscontaindetailedsystemandequipmentdescriptionsandrelated informationabouttheproduct,which<ORAIMOTECHNOLOGYLIMITED.>considerstobe proprietary,confidential,andacustomdesignandotherwise,wouldnotreleasetothe generalpublic.Sincethisdesignisabasisfromwhichfuturetechnologicalproductswill evolve,<ORAIMOTECHNOLOGYLIMITED.>feelsthatthisinformationwouldbeofbenefit toitscompetitors,andthatthedisclosureoftheinformationinthesedocumentswouldgive ourcompetitorsanunfairadvantageinthemarket. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, Name:GreenyXian Function:Manager Signature:
LabelLocation: ThisdevicecomplieswithPart15oftheFCCRules. Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptany interferencereceived,includinginterferencethat maycauseundesiredoperation.
FCC ID: 2AXYP-OTW-625-L Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BT: Test Mode Channel Frequency (GHz) Conducted power (dBm) Conducted power (mW) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculation SAR Exclusion threshold SAR test exclusion GFSK 2.402 4.26 2.67 4.50 2.82 5.00 0.874 3.00 Yes 2.441 3.22 2.10 4.50 2.82 5.00 0.881 3.00 Yes 2.480 2.55 1.80 4.50 2.82 5.00 0.888 3.00 Yes π/4- DQPSK 2.402 6.22 4.19 6.50 4.47 5.00 1.385 3.00 Yes 2.441 5.09 3.23 6.50 4.47 5.00 1.396 3.00 Yes 2.480 4.45 2.79 6.50 4.47 5.00 1.407 3.00 Yes 8-DPSK 2.402 6.73 4.71 7.00 5.01 5.00 1.554 3.00 Yes 2.441 5.77 3.78 7.00 5.01 5.00 1.566 3.00 Yes 2.480 5.09 3.23 7.00 5.01 5.00 1.579 3.00 Yes BLE: Test Mode Channel Frequency (GHz) Conducted power (dBm) Conducted power (mW) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculation SAR Exclusion threshold SAR test exclusion BLE(1M) 2.402 4.72 2.96 5.00 3.16 5.00 0.980 3.00 Yes 2.441 3.62 2.30 5.00 3.16 5.00 0.988 3.00 Yes 2.480 2.79 1.90 5.00 3.16 5.00 0.996 3.00 Yes BLE(2M) 2.402 4.59 2.88 5.00 3.16 5.00 0.980 3.00 Yes 2.441 3.53 2.25 5.00 3.16 5.00 0.988 3.00 Yes 2.480 2.74 1.88 5.00 3.16 5.00 0.996 3.00 Yes Conclusion: For the max result : 1.579≤ FCC Limit 3.0 for 1g SAR.
AntennaSampleDatasheet customer: ZhongshanTianjian electroacousticCo.,LTD entryname:OTW620 Materialcategory:BTantenna AntennaType PIFA AntennaMaterial FPC edition:A0 Date:2024.6.28 Antennamanufacturer:HongjiWirelessCommunication(Shenzhen)Co.,LTD http://www.honant.com.cn Address:12/F,WestBlockB,Building8,HuaqiangCreativeIndustryPark, SightseeingRoad,GuangmingDistrict,Shenzhen Contents 1:Antennatestequipment.................................................1 2:Passivetestreport...........................................................3 3:Structuraldrawing...........................................................5 4:Antennadiagram.............................................................6 1 1 : Antennatestequipment Listofmeters:Agilent5071B; 1.1TheprinciplediagramoftheETSanochoicchamber Picture1.Antennastatictestconnectionmethod 2 1.2PicturesoftheETSanochoicchamber InsidetheETSanochoicchamber TestMachine 3 2 : Passivetestreport 2.1:antennaS11parameters 2.2:Passiveefficiencyofantenna Freq(MHz)Gain(dBi)Efficiency(%) 2400 1.2735.49 2410 1.3435.31 2420 1.7635.18 2430 2.2134.3 2440 2.3833.55 2450 2.4933.97 2460 2.4934.06 2470 2.5934.75 2480 2.4736.2 4 2.3:PassivepatternofBTantenna 2400MHz 5 3 : Structuraldrawing G F E D C A 3 4 2 G F 56 D C B A 1 563 4 B 1 2 E D a t e A 1 0 2 0 2 4 - 5 - 2 1 C h a n g e a n t e n n a 6 4 : Antennadiagram
Report No.: WSCT-ANAB-R&E240700034A-LE Page 2 of 51 TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. Genera Information .................................................................................. 7 4.1. TEST ENVIRONMENT AND MODE .............................................................................................................. 7 4.2. DESCRIPTION OF SUPPORT UNITS .......................................................................................................... 7 5. Facilities and Accreditations .................................................................. 8 5.1. FACILITIES ............................................................................................................................................ 8 5.2. ACCREDITATIONS ............................................................................................................................ 8 5.3. MEASUREMENT UNCERTAINTY ............................................................................................................... 9 5.4. MEASUREMENT INSTRUMENTS ................................................................................................... 10 6. Test Results and Measurement Data ................................................... 11 6.1. ANTENNA REQUIREMENT ...................................................................................................................... 11 6.2. CONDUCTED EMISSION ........................................................................................................................ 12 6.3. CONDUCTED OUTPUT POWER .............................................................................................................. 14 6.4. EMISSION BANDWIDTH ......................................................................................................................... 19 6.5. CONDUCTED BAND EDGE AND SPURIOUS EMISSION MEASUREMENT ..................................................... 29 6.6. RADIATED SPURIOUS EMISSION MEASUREMENT ................................................................................... 40 7. Test Setup Photographs ....................................................................... 51 Report No.: WSCT-ANAB-R&E240700034A-LE Page 4 of 51 2. Test Result Summary Requirement CFR 47 Section Result Antenna requirement §15.203/§15.247 (c) PASS AC Power Line Conducted Emission §15.207 N/A Maximum conducted output power §15.247 (b)(3) §2.1046 PASS 6dB Emission Bandwidth §15.247 (a)(2) §2.1049 PASS Power Spectral Density §15.247 (e) PASS Band Edge 1§5.247(d) §2.1051, §2.1057 PASS Spurious Emission §15.205/§15.209 §2.1053, §2.1057 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Report No.: WSCT-ANAB-R&E240700034A-LE Page 5 of 51 3. EUT Description Product Name: True Wireless Earbuds Model : OTW-625 Trade Mark: oraimo Software version: V0.1.9 Hardware version: V6.0 Operation Frequency: 2402MHz~2480MHz Channel Separation: 2MHz Number of Channel: 40 Modulation Technology: GFSK Antenna Type: PIFA Antenna Antenna Gain: 2.59dBi Operating Voltage: Li-ion Polymer Battery: 1254 Voltage: 3.87V Rated Capacity: 75mAh Limited Charge Voltage: 4.45V Charging Box: 951445 Input: 5V500mA Capacity:570mAh/3.7V/2.109Wh Remark: N/A. Note: 1. N/A stands for no applicable. 2. Antenna gain provided by the customer. Report No.: WSCT-ANAB-R&E240700034A-LE Page 6 of 51 Operation Frequency each of channel Channel Frequency Channel Frequency Channel Frequency Channel Frequency 0 2402MHz 10 2422MHz 20 2442MHz 30 2462MHz 1 2404MHz 11 2424MHz 21 2444MHz 31 2464MHz ... ... ... ... ... ... ... ... 8 2418MHz 18 2438MHz 28 2458MHz 38 2478MHz 9 2420MHz 19 2440MHz 29 2460MHz 39 2480MHz Remark: Channel 0, 19 & 39 have been tested. Report No.: WSCT-ANAB-R&E240700034A-LE Page 7 of 51 4. Genera Information 4.1. Test environment and mode Operating Environment: Temperature: 25.0 C Humidity: 56 % RH Atmospheric Pressure: 1010 mbar Test Mode: Engineering mode: Keep the EUT in continuous transmitting by select channel and modulations(The value of duty cycle is 98.46%) with Fully-charged battery. The sample was placed (0.1m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. 4.2. Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Equipment Model No. Serial No. FCC ID Trade Name / / / / / Note: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. 3. For conducted measurements (Output Power, 6dB Emission Bandwidth, Power Spectral Density, Spurious Emissions), the antenna of EUT is connected to the test equipment via temporary antenna connector, the antenna connector is soldered on the antenna port of EUT, and the tempora…
Text truncated - open the document above for the full version.
Building A-B, Baoshi Science & Technology Park, Ba · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |
Smart Watch
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSmart Watch
Equipment Class
PCE - PCS Licensed Transmitter held to earSmart Watch
Equipment Class
DTS - Digital Transmission SystemSmart Watch
Equipment Class
DTS - Digital Transmission SystemSmart Watch
Equipment Class
JAB - Part 15 Class B Digital Device