
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1. Choking hazard -Small parts. Children should use the device under adult supervision. 2. Built-in non-removable battery,any improper usage may cause battery safety hazards and lead to safety problems. 3. For better protect battery, we recommend not use the pencil when charging. 4. We recommend using replacement tips officially manufactured by metapen. 5.Please use the device within 0'C~35°c, and store it within -20°C~45°c. Too high or low temperature may cause malfunction. 6. Please charge within 0°C~40'C to avoid battery performance degradation and standby time reduction. 7. Do not use the device in wet places or near strong magnetic fields. Metapen Pencil Crown User Manual Packing List Compatible devices Quick Guide 1. Power on 2. Power off 3. Charging Rotary button Type-C Charging Port LED Indicator Replaceable Tip Metapen Pencil Crown User Manual Pen Tips Type-C Cable Customer Service Website: www.metapen.com Email: [email protected] iPad Pro 13-inch (M4, M5 and later) iPad Pro 12.9-inch (3rd, 4th, 5th, 6th) iPad Pro 11-inch (1st, 2nd, 3rd, 4th, M4, M5 and later) iPad Air (3rd, 4th, 5th, M2, M3, M4 and later) iPad (6th, 7th, 8th, 9th, 10th, A16 and later) iPad Mini (5th, 6th and A17 Pro and later) No need to pair with an APP or Bluetooth, ready to use when it's on. Click once the button to turn on the Pencil Crown. The indicator light will show the power level. Battery Power Percentage: White: ≥60% Blue: 20%~60% Red: ≤20% Warning Please use our included Type-C cable and make sure the charger is connected properly. When charging: Red breathing light Fully charged: White breathing light 4. Replace the pen tip If you need to replace the pen tip, unscrew the old tip counterclockwise and then screw in the new tip clockwise. Press and hold the button for 2 seconds or leave it inactive for 5 minutes. The Pencil Crown will automatically shut down and the indicator light will go out after the pencil is turned off. *How to find your iPad Model:Settings → General → About → Model Name *Please ensure your iPad is running iOS 12.2 or later. * If your iPad was paired with an Apple pencil before, please unpair it before using the pen. Specification FAQ Correct Disposal of This Product FCC Statement Q1: Why my pencil can't work with my iPad? 1) Make sure that Pencil Crown turns on. 2) The pencil Pencil Crown supports iPad series 2018 and later models. Not work for iPad before 2018, iPhone, Android, Microsoft devices. *Identify your iPad model: Tap Settings → Tap General → Tap About → Find Model Name → Check the "Compatible devices" part at the beginning. 3) All iPad models must be updated to iOS 12.2 or above. Use the official notes downloaded in the App store. 4) If iPad was paired with an Apple pencil before, unpair it before using the Pencil Crown. Q2: Why my pencil does not turn on or has battery problems? 1) Please make sure your pencil is fully charged (led will turn White) 2) Click once the button to turn it on, long press for 2 seconds to turn it off. 3) When charging, use our included Type-C cable and make sure the charger is connected properly. If the tips above do not solve your problem, please don't worry and feel free to contact us at support@metap- en.com (24 Hours Fast Response & 12 Months Warranty) To prevent possible harm to the environment on human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household user should contact either the retailer where they purchased this product or their local government office, for details of where and hew they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contact This product should not be mixed with other commercial wastes for disposal. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ISED statement This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RF Radiation Exposure (Waste Electrical & Electronic Equipment) This Marking shown on the product or its literature, indicate that it should not be disposed with other household wastes at the end of its working life. 8. Keep the device dry and do not use harsh chemicals, strong cleaning to clean the device. Wipe the device with a clean, dry soft cloth. 9. lf any part of the device is cracked or broken,please stop using it immediately and contact us: [email protected] Item name Model Number Battery Type Charging Method Charging Time Using Time Standby Time Metapen Pencil Crown ME-APP812 125mAh lithium battery Type-C 30 minutes 15 hours when full charged 365 days *Wireless charging is not supported. CAN ICES(B)/NMB(B) Name: Sea&Mew Accounting Ltd Address: Electric Avenue Vision 25, London, Enfield EN3 7GD Contact Person: Billy Han E-mail: [email protected] Name: Sea&Mew Consulting GmbH Address: Mittenhuber Straße 4,92318 Neumarkt Contact Person: Yuan Li E-mail: [email protected] U…
Text truncated - open the document above for the full version.
Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District,Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: Our product Metapen Pencil Crown, Model: ME-APP812, FCC ID: 2AYOT-APP812. For use in America, this product only support BLE 1M/2M. The other functions, bands and modes has been shielded by the manufacturer using the software, the end user has no capability to activate it. Sincerely Yours, Signature: Contact person: Yang Young Title: Prod uct Manager
Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District, Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2AYOT-APP812 Shenzhen qianfenyi intelligent technology co., LTD. certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely Yours, Signature: Contact person: Yang Young Title: Product Manager
CFR 47 §2.911 (d)(5)(ii) Attestation Letter Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District, Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] Attestation Letter Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2AYOT-APP812 Shenzhen qianfenyi intelligent technology co., LTD. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely Yours, Signature: Contact person: Yang Young Title: Product Manager
U.S. AGENT LETTER OF ATTESTATION Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2AYOT-APP812 Shenzhen qianfenyi intelligent technology co., LTD. certifies that, as of the date of the filing of the application, Iconsigh is our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen qianfenyi intelligent technology co., LTD. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, United States FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Shenzhen qianfenyi intelligent technology co., LTD. Address: Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District, Shenzhen China 518000 FRN: 0030404388 Tel: +86 13728616862 Email:[email protected] Signed by (printed name): Yang Young Signature:
Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District,Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Shenzhen qianfenyi intelligent technology co., LTD., the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Contact person: Yang Young Title: Product Manager
Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District, Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] FCC Confidential Authorization Date: 2026-08-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AYOT-APP812 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen qianfenyi intelligent technology co., LTD. hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Contact person: Yang Young Title: Product Manager
Shenzhen qianfenyi intelligent technology co., LTD. Address:Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District,Shenzhen China 518000 TEL: +86 13728616862 FAX: +86 0755 8615 3780 E-mail:[email protected] Date: 2026-08-31 Declaration of Similarity FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Shenzhen qianfenyi intelligent technology co., LTD. hereby declare that we have a product named as Metapen Pencil Crown, the models: ME-APP812, FCC ID:2AYOT-APP812, was tested by Bay Area Compliance Laboratories Corp.(Shenzhen). Meanwhile, For our marketing purpose, the model ME-APP812 will have two Colors. The products are electrically identical, only differing in color, there is no other difference. The differences between the two Colors are shown in the following table: A B Remarks A is black and B is white We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely Yours, Signature: Contact person: Young Yang Title: Product Manager
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 1 of 8 EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 2 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 3 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 4 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 5 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 6 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 7 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-EXP Page 8 of 8
Product Name: Metapen Pencil CrownProduct Model: ME-APP812Rating: 5V 320mAManufacturer: Shenzhen Qianfenyi Intelligent Technology Co., LTD Made in China FCC ID: 2AYOT-APP812IC: 26903-MEAPP812 211-260805
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-INP Page 1 of 5 EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-INP Page 2 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-INP Page 3 of 5 ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-INP Page 4 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-INP Page 5 of 5
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RFA TR-EM-RF011 Page 29 of 81 Version 4.2 RF EXPOSURE EVALUATION RF EXPOSURE EVALUATION Applicable Standard According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where 1. f(GHz) is the RF channel transmit frequency in GHz. 2. Power and distance are rounded to the nearest mW and mm before calculation. 3. The result is rounded to one decimal place for comparison. 4. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test Exclusion. Measurement Result For worst case: Mode Frequency (MHz) Max tune-up conducted power # (dBm) Max tune-up conducted power # (mW) Distance (mm) Calculated value Threshold (1-g SAR) SAR Test Exclusion BLE2402-24800.5 1.150.43.0Yes Result: Compliant
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF011 Page 1 of 81 Version 4.2 TEST REPORT Applicant Name:FCC: Shenzhen qianfenyi intelligent technology co., LTD. IC: Shenzhen Qianfenyi Intelligent Technology Co., LTD Address:FCC: Room 2101, Building 3, Nanshan i Park Chongwen,3370 Liuxian Avenue, Nanshan District,Shenzhen China 518000 IC: Room 2101, Building 3, Nanshan i Park Chongwen, 3370 Liuxian Avenue, Nanshan District Shenzhen 518000 China (Peoples Republic Of) Report Number:2601W73931E-RFA FCC ID:2AYOT-APP812 IC:26903-MEAPP812 Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247 ISSUE 4, JULY 2025 Sample Description Product Type:Metapen Pencil Crown Model No.:ME-APP812 Multiple Model(s) No.:N/A Trade Mark:N/A Date Received:2026-08-06 Issue Date:2026-09-08 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Navilite CaiJimmy Xiao RF EngineerEMC Manager Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RFA TR-EM-RF011 Page 2 of 81 Version 4.2 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ................................................................................................................................9 TEST EQUIPMENT LIST ..........................................................................................................................................10 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................12 AC LINE CONDUCTED EMISSIONS...............................................................................................................................12 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................15 99% OCCUPIED BANDWIDTH & 6 DB EMISSION BANDWIDTH ....................................................................................18 PEAK OUTPUT POWER MEASUREMENT .......................................................................................................................21 POWER SPECTRAL DENSITY ........................................................................................................................................22 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................24 CONDUCTED SPURIOUS EMISSION...............................................................................................................................26 DUTY CYCLE ...............................................................................................................................................................28 RF EXPOSURE EVALUATION ................................................................................................................................29 ANTENNA REQUIREMENT .....................................................................................................................................32 TEST DATA AND RESULTS .....................................................................................................................................34 AC LINE CONDUCTED EMISSIONS...............................................................................................................................34 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................37 RF CONDUCTED DATA ............................................................................................................…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-TSP Page 1 of 4 TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-TSP Page 2 of 4 Radiated Emissions View (Below 30MHz) Radiated Emissions View (Above 30MHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-TSP Page 3 of 4 Radiated Emissions View (1-18 GHz) Radiated Emissions View (18-25 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601W73931E-RF-TSP Page 4 of 4 RF Conducted View
2310 Homestead Road, Suite C1 · Los Altos, California, 94024 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |

Metapen Pencil D1
Equipment Class
DTS - Digital Transmission System
Metapen Pencil A11 Pro
Equipment Class
DTS - Digital Transmission System
HP MPP 1.51 Pen
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
HP USI Garaged Pen
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz