FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Luxshare Precision Industry Co., Ltd./
  3. 2AYYS-JS620K4Y

2AYYS-JS620K4YJS620K4

Luxshare Precision Industry Co., Ltd.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jan 28, 2026
Application Purpose
Original Equipment
Equipment Note
JS620K4
Frequency Range
5180.00000000 - 5240.00000000
Company
Luxshare Precision Industry Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

Luxshare Precision Industry Co.,Ltd. TEST REPORT SCOPE OF WORK FCC TESTING– 33841815, 33841815WT REPORT NUMBER 251117042SZN-004 ISSUE DATE [REVISED DATE] Jan. 21, 2026 [--------------------] PAGES 46 DOCUMENT CONTROL NUMBER FCC ID 247_b © 2017 INTERTEK Intertek Report No.: 251117042SZN-004 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Service Shenzhen Ltd. Longhua Branch 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Version: 01-November-2017 Page: 1 of 46 FCC ID 247_b TEST REPORT 101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, Shenzhen. Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 www.intertek.com RF Test Report Applicant: Luxshare Precision Industry Co.,Ltd. Address of Applicant: Floor 2, Block A, Sanyo New Industrial Area, West Haoyi Community, Shajing Subdistrict Office, Bao an District Shenzhen, China. Equipment Under Test (EUT) Product Name: JS620K4 Model No.: 33841815, 33841815WT Trademark: N/A FCC ID: 2AYYS-JS620K4Y Applicable Standards: FCC CFR Title 47 Part 15E (§15.407) Date of Test: Nov. 17, 2025 to Jan. 09, 2026 Test Result: PASS Prepared and Checked by: Approved by: Tony Tang Johnny Wang Engineer Project Engineer Date: Jan. 21, 2026 TEST REPORT Intertek Report No.: 251117042SZN-004 Version: 01-November-2017 Page: 2 of 46 FCC ID 247_b 1 Revision History Report No. Version No. Description Issued Date 251117042SZN-004 01 Original Jan. 21, 2026 TEST REPORT Intertek Report No.: 251117042SZN-004 Version: 01-November-2017 Page: 3 of 46 FCC ID 247_b 2 Content 1 Revision History ........................................................................................................................................ 2 2 Content..................................................................................................................................................... 3 3 Summary of Test Result ............................................................................................................................ 4 4 General Information ................................................................................................................................. 5 5 Test Specifications .................................................................................................................................... 7 6 Antenna Requirement ............................................................................................................................ 13 7 Duty Cycle ............................................................................................................................................... 14 8 26 dB Bandwidth & 99% Occupied Bandwidth ........................................................................................ 15 9 Minimum 6dB bandwidth ....................................................................................................................... 16 10 Maximum Conducted Output Power ...................................................................................................... 17 11 Power spectrum density ......................................................................................................................... 25 12 Frequency Stability ................................................................................................................................. 26 14 Radiated Emission .................................................................................................................................. 27 15 AC Power line Conducted Emission ......................................................................................................... 38 16 Dynamic Frequency Selection (DFS) ........................................................................................................ 41 TEST REPORT Intertek Report No.: 251117042SZN-004 Version: 01-November-2017 Page: 4 of 46 FCC ID 247_b 3 Summary of Test Result TEST ITEM FCC REFERENCE RESULT Antenna requirement 15.203 Pass Duty Cycle - Pass 26 dB Bandwidth & 99% Occupied Bandwidth 15.407(a) Pass Minimum 6dB Bandwidth 15.407(e) Pass Maximum Conducted Output Power 15.407(a) Pass Power spectral density 15.407(a) Pass Frequency Stability 15.407(g) Pass Radiated Emission and Band Edge 15.407(b), 15.205, 15.209 Pass AC Power line conducted emission 15.207 Pass Dynamic Frequency Selection 15.407(h) Pass TEST REPORT Intertek Report No.: 251117042SZN-004 Version: 01-November-2017 Page: 5 of 46 FCC ID 247_b 4 General Information 4.1 Client Information Applicant: Luxshare Precision Industry Co.,Ltd. Address: Floor 2, Block A, Sanyo New Industrial Area, West Haoyi Community, Shajing Subdistrict Office, Bao an District Shenzhen, China. Manufacturer: Luxshare Precision Industry Co.,Ltd. Address: Floor 2, Block A, Sanyo New Industrial Area, West Haoyi Community, Shajing Subdistrict Office, Bao an District Shenzhen, China. 4.2 Description of Equipment Under Test (EUT) Product Name: JS620K4 Model No.: 33841815, 3384…

Text truncated - open the document above for the full version.

Test Report

Report No.: TBR-C-202501-0081-17 Page: 92 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11AX40 Mode 5755MHz Horizontal Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 93 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11 AX40 Mode 5755MHz Vertical Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 94 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11AC40 Mode 5795MHz Horizontal Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 95 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11 AC40 Mode 5795MHz Vertical Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 96 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11AC80 Mode 5775MHz Horizontal Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 97 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11 AC80 Mode 5775MHz Vertical Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 98 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11AX80 Mode 5775MHz Horizontal Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 99 of 185 TB-RF-074-1.0 Test Voltage: DC 3.3V Test Mode: TX 802.11 AX80 Mode 5795MHz Vertical Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG(dBμV/m) 4. The tests evaluated 1-40GHz,The testing has been conformed to the 10th harmonic of the highest fundamental frequency or 40GHz. Test with highpass filter (Pass Frequency:8-25G). 5. No report for the emission which more than 20dB below the prescribed limit. 6. The peak value<average limit, So only show the peak value. and 26.5GHz-40GHz is the noise,No other signals were detected. Report No.: TBR-C-202501-0081-17 Page: 100 of 185 TB-RF-074-1.0 Attachment C-- Restricted Bands Requirement Test Data Radiation Test Test Voltage: DC 3.3V Ant. Pol. Horizontal Test Mode: TX 802.11a Mode 5180 MHz (U-NII-1) Remark: Only evaluate the data of the worst antenna A Remark: 1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)+AMP(dB) 2. Peak/AVG (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV) 3. Margin (dB) = Peak/AVG (dBμV/m)-Limit PK/AVG…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202501-0081-17 Page: 1 of 185 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Test Report FCC ID:2AMM6EWN-8852BSN3DB Report No. : TBR-C-202501-0081-17 Applicant : Earda Technologies Co.,Ltd Equipment Under Test (EUT) EUT Name : WiFi & BT combo module Model No. : EWN-8852BSN3DB Series Model No. : N/A Brand Name : EARDATEK Sample ID : HC-C-202501-0081-01-01&HC-C-202501-0081-02-01 Receipt Date : 2025-03-31 Test Date : 2025-03-31 to 2025-05-20 Issue Date : 2025-05-20 Standards : FCC Part 15 Subpart E 15.407 Test Method : ANSI C63.10: 2013 KDB 789033 D02 General UNII Test Procedures New Rules v02r01 KDB 662911 D01 Multiple Transmitter Output v02r01 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Gold zhang Reviewed By : Henry huang Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202501-0081-17 Page: 2 of 185 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................ 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................ 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 7 1.4 Description of Support Units .............................................................................................. 9 1.5 Description of Test Mode ................................................................................................. 10 1.6 Description of Test Software Setting .............................................................................. 12 1.7 Measurement Uncertainty ................................................................................................ 15 1.8 Test Facility......................................................................................................................... 16 2. TEST SUMMARY..................................................................................................................... 17 3. TEST SOFTWARE .................................................................................................................. 17 4. TEST EQUIPMENT AND TEST SITE .................................................................................. 18 5. CONDUCTED EMISSION TEST ........................................................................................... 20 5.1 Test Standard and Limit ................................................................................................... 20 5.2 Test Setup........................................................................................................................... 20 5.3 Test Procedure .................................................................................................................. 20 5.4 Deviation From Test Standard......................................................................................... 20 5.5 EUT Operating Mode ........................................................................................................ 20 5.6 Test Data............................................................................................................................. 21 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 22 6.1 Test Standard and Limit ................................................................................................... 22 6.2 Test Setup........................................................................................................................... 23 6.3 Test Procedure .................................................................................................................. 24 6.4 Deviation From Test Standard......................................................................................... 25 6.5 EUT Operating Mode ........................................................................................................ 25 6.6 Test Data............................................................................................................................. 25 7. RESTRICTED BANDS REQUIREMENT ............................................................................. 26 7.1 Test Standard and Limit ................................................................................................... 26 7.2 Test Setup........................................................................................................................... 27 7.3 Test Procedure .................................................................................................................. 27 7.4 Deviation From Test Standard......................................................................................... 28 7.5 EUT Operating Mode ........................................................................................................ 28 7.6 Test Data............................................................................................................................. 28 8. BANDWIDTH TEST................................................................................................................. 29 8.1 Test Standard and Limit ................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 135 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AX80-CDD-Ant1-5290-PASS 11AX80-CDD-Ant2-5290-PASS 11AX80-CDD-Ant1-5530-PASS 11AX80-CDD-Ant2-5530-PASS 11AX80-CDD-Ant1-5610-PASS 11AX80-CDD-Ant2-5610-PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 136 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AX80-CDD-Ant1-5690_UNII-2C-PASS 11AX80-CDD-Ant2-5690_UNII-2C-PASS 11AX80-CDD-Ant1-5690_UNII-3-PASS 11AX80-CDD-Ant2-5690_UNII-3-PASS 11AX80-CDD-Ant1-5775-PASS 11AX80-CDD-Ant2-5775-PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 137 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 8: Frequency Stability 8.1 Test Result TestMode Antenna Frequency [MHz] Voltage [Vdc] Temperature (°C) Deviation (Hz) Deviation (ppm) Limit (ppm) Verdict 11AX20-CDD Ant1 5180 NV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant1 5180 LV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant1 5180 HV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant2 5180 NV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant2 5180 LV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant2 5180 HV NT -20000.00 -3.861004 20 PASS 11AX20-CDD Ant1 5260 NV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant1 5260 LV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant1 5260 HV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant2 5260 NV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant2 5260 LV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant2 5260 HV NT -20000.00 -3.802281 20 PASS 11AX20-CDD Ant1 5500 NV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant1 5500 LV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant1 5500 HV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant2 5500 NV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant2 5500 LV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant2 5500 HV NT -20000.00 -3.636364 20 PASS 11AX20-CDD Ant1 5745 NV NT -20000.00 -3.481288 20 PASS 11AX20-CDD Ant1 5745 LV NT -20000.00 -3.481288 20 PASS 11AX20-CDD Ant1 5745 HV NT -20000.00 -3.481288 20 PASS 11AX20-CDD Ant2 5745 NV NT -20000.00 -3.481288 20 PASS 11AX20-CDD Ant2 5745 LV NT -20000.00 -3.481288 20 PASS 11AX20-CDD Ant2 5745 HV NT -20000.00 -3.481288 20 PASS 11AX40-CDD Ant1 5190 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5190 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5190 HV NT -40000.00 -7.707129 20 PASS 11AX40-CDD Ant2 5190 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5190 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5190 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5230 NV NT -40000.00 -7.648184 20 PASS 11AX40-CDD Ant1 5230 LV NT -40000.00 -7.648184 20 PASS 11AX40-CDD Ant1 5230 HV NT -40000.00 -7.648184 20 PASS 11AX40-CDD Ant2 5230 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5230 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5230 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5270 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5270 LV NT -40000.00 -7.590133 20 PASS 11AX40-CDD Ant1 5270 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5270 NV NT 0.00 0.000000 20 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 138 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AX40-CDD Ant2 5270 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5270 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5510 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5510 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5510 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5510 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5510 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5510 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5755 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5755 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant1 5755 HV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5755 NV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5755 LV NT 0.00 0.000000 20 PASS 11AX40-CDD Ant2 5755 HV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant1 5210 NV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant1 5210 LV NT -80000.00 -15.355086 20 PASS 11AX80-CDD Ant1 5210 HV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant2 5210 NV NT -80000.00 -15.355086 20 PASS 11AX80-CDD Ant2 5210 LV NT -80000.00 -15.355086 20 PASS 11AX80-CDD Ant2 5210 HV NT -80000.00 -15.355086 20 PASS 11AX80-CDD Ant1 5290 NV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant1 5290 LV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant1 5290 HV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant2 5290 NV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant2 5290 LV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant2 5290 HV NT -80000.00 -15.122873 20 PASS 11AX80-CDD Ant1 5530 NV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant1 5530 LV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant1 5530 HV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant2 5530 NV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant2 5530 LV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant2 5530 HV NT -80000.00 -14.466546 20 PASS 11AX80-CDD Ant1 5775 NV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant1 5775 LV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant1 5775 HV NT 0.00 0.000000 20 PASS 11AX80-CDD Ant2 5775 NV NT -80000.00 -13.852814 20 PASS 11AX80-CDD Ant2 5775 LV NT -80000.00 -13.852814 20 PASS 11AX80-CDD Ant2 5775 HV NT -80000.00 -13.852814 20 PASS Note: RF Conducted test Offset= cable loss+ Attenuator(10dB). --- END OF REPORT ---

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 101 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AC20-CDD total 5745 --- --- 5.22 ≤27.35 PASS 11AC20-CDD Ant1 5785 1.98 0.04 2.02 ≤30.00 PASS 11AC20-CDD Ant2 5785 1.93 0.06 1.99 ≤30.00 PASS 11AC20-CDD total 5785 --- --- 5.02 ≤27.35 PASS 11AC20-CDD Ant1 5825 1.62 0.06 1.68 ≤30.00 PASS 11AC20-CDD Ant2 5825 2.16 0.06 2.22 ≤30.00 PASS 11AC20-CDD total 5825 --- --- 4.97 ≤27.35 PASS 11AC40-CDD Ant1 5190 0.85 0.08 0.93 ≤11.00 PASS 11AC40-CDD Ant2 5190 1.03 0.00 1.03 ≤11.00 PASS 11AC40-CDD total 5190 --- --- 3.99 ≤9.22 PASS 11AC40-CDD Ant1 5230 0.41 0.09 0.50 ≤11.00 PASS 11AC40-CDD Ant2 5230 0.56 0.11 0.67 ≤11.00 PASS 11AC40-CDD total 5230 --- --- 3.60 ≤9.22 PASS 11AC40-CDD Ant1 5270 0.66 0.07 0.73 ≤11.00 PASS 11AC40-CDD Ant2 5270 0.58 0.08 0.66 ≤11.00 PASS 11AC40-CDD total 5270 --- --- 3.71 ≤8.61 PASS 11AC40-CDD Ant1 5310 0 0.11 0.11 ≤11.00 PASS 11AC40-CDD Ant2 5310 0.03 0.09 0.12 ≤11.00 PASS 11AC40-CDD total 5310 --- --- 3.13 ≤8.61 PASS 11AC40-CDD Ant1 5510 0.57 0.00 0.57 ≤11.00 PASS 11AC40-CDD Ant2 5510 0.1 0.08 0.18 ≤11.00 PASS 11AC40-CDD total 5510 --- --- 3.39 ≤8.32 PASS 11AC40-CDD Ant1 5550 0.63 0.11 0.74 ≤11.00 PASS 11AC40-CDD Ant2 5550 0.04 0.11 0.15 ≤11.00 PASS 11AC40-CDD total 5550 --- --- 3.47 ≤8.32 PASS 11AC40-CDD Ant1 5710_UNII-2C 1.4 0.11 1.51 ≤11.00 PASS 11AC40-CDD Ant2 5710_UNII-2C 1.18 0.11 1.29 ≤11.00 PASS 11AC40-CDD total 5710_UNII-2C --- --- 4.41 ≤8.32 PASS 11AC40-CDD Ant1 5710_UNII-3 -2.38 0.11 -2.27 ≤30.00 PASS 11AC40-CDD Ant2 5710_UNII-3 -2.67 0.11 -2.56 ≤30.00 PASS 11AC40-CDD total 5710_UNII-3 --- --- 0.60 ≤27.35 PASS 11AC40-CDD Ant1 5755 -0.59 0.08 -0.51 ≤30.00 PASS 11AC40-CDD Ant2 5755 -0.67 0.08 -0.59 ≤30.00 PASS 11AC40-CDD total 5755 --- --- 2.46 ≤27.35 PASS 11AC40-CDD Ant1 5795 -0.93 0.11 -0.82 ≤30.00 PASS 11AC40-CDD Ant2 5795 -0.69 0.11 -0.58 ≤30.00 PASS 11AC40-CDD total 5795 --- --- 2.31 ≤27.35 PASS 11AC80-CDD Ant1 5210 -1.58 0.15 -1.43 ≤11.00 PASS 11AC80-CDD Ant2 5210 -1.93 0.15 -1.78 ≤11.00 PASS 11AC80-CDD total 5210 --- --- 1.41 ≤9.22 PASS 11AC80-CDD Ant1 5290 -2.58 0.15 -2.43 ≤11.00 PASS 11AC80-CDD Ant2 5290 -2.62 0.15 -2.47 ≤11.00 PASS 11AC80-CDD total 5290 --- --- 0.56 ≤8.61 PASS 11AC80-CDD Ant1 5530 -1.19 0.15 -1.04 ≤11.00 PASS 11AC80-CDD Ant2 5530 -2.27 0.00 -2.27 ≤11.00 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 102 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AC80-CDD total 5530 --- --- 1.40 ≤8.32 PASS 11AC80-CDD Ant1 5610 -1.24 0.23 -1.01 ≤11.00 PASS 11AC80-CDD Ant2 5610 -2.47 0.23 -2.24 ≤11.00 PASS 11AC80-CDD total 5610 --- --- 1.43 ≤8.32 PASS 11AC80-CDD Ant1 5690_UNII-2C -0.87 0.23 -0.64 ≤11.00 PASS 11AC80-CDD Ant2 5690_UNII-2C -0.77 0.18 -0.59 ≤11.00 PASS 11AC80-CDD total 5690_UNII-2C --- --- 2.40 ≤8.32 PASS 11AC80-CDD Ant1 5690_UNII-3 -4.15 0.23 -3.92 ≤30.00 PASS 11AC80-CDD Ant2 5690_UNII-3 -3.7 0.18 -3.52 ≤30.00 PASS 11AC80-CDD total 5690_UNII-3 --- --- -0.71 ≤27.35 PASS 11AC80-CDD Ant1 5775 -4.05 0.15 -3.90 ≤30.00 PASS 11AC80-CDD Ant2 5775 -4.01 0.15 -3.86 ≤30.00 PASS 11AC80-CDD total 5775 --- --- -0.87 ≤27.35 PASS 11AX20-CDD Ant1 5180 3.67 0.04 3.71 ≤11.00 PASS 11AX20-CDD Ant2 5180 3.82 0.04 3.86 ≤11.00 PASS 11AX20-CDD total 5180 --- --- 6.80 ≤9.22 PASS 11AX20-CDD Ant1 5200 3.57 0.07 3.64 ≤11.00 PASS 11AX20-CDD Ant2 5200 3.67 0.07 3.74 ≤11.00 PASS 11AX20-CDD total 5200 --- --- 6.70 ≤9.22 PASS 11AX20-CDD Ant1 5240 3.05 0.07 3.12 ≤11.00 PASS 11AX20-CDD Ant2 5240 3.5 0.07 3.57 ≤11.00 PASS 11AX20-CDD total 5240 --- --- 6.36 ≤9.22 PASS 11AX20-CDD Ant1 5260 3.41 0.04 3.45 ≤11.00 PASS 11AX20-CDD Ant2 5260 3.57 0.04 3.61 ≤11.00 PASS 11AX20-CDD total 5260 --- --- 6.54 ≤8.61 PASS 11AX20-CDD Ant1 5280 3.14 0.07 3.21 ≤11.00 PASS 11AX20-CDD Ant2 5280 3.13 0.05 3.18 ≤11.00 PASS 11AX20-CDD total 5280 --- --- 6.21 ≤8.61 PASS 11AX20-CDD Ant1 5320 2.69 0.05 2.74 ≤11.00 PASS 11AX20-CDD Ant2 5320 2.86 0.07 2.93 ≤11.00 PASS 11AX20-CDD total 5320 --- --- 5.85 ≤8.61 PASS 11AX20-CDD Ant1 5500 3.48 0.00 3.48 ≤11.00 PASS 11AX20-CDD Ant2 5500 3.07 0.04 3.11 ≤11.00 PASS 11AX20-CDD total 5500 --- --- 6.31 ≤8.32 PASS 11AX20-CDD Ant1 5580 3.58 0.07 3.65 ≤11.00 PASS 11AX20-CDD Ant2 5580 2.63 0.07 2.70 ≤11.00 PASS 11AX20-CDD total 5580 --- --- 6.21 ≤8.32 PASS 11AX20-CDD Ant1 5720_UNII-2C 5.83 0.05 5.88 ≤11.00 PASS 11AX20-CDD Ant2 5720_UNII-2C 2.64 0.07 2.71 ≤11.00 PASS 11AX20-CDD total 5720_UNII-2C --- --- 7.59 ≤8.32 PASS 11AX20-CDD Ant1 5720_UNII-3 2.25 0.05 2.30 ≤30.00 PASS 11AX20-CDD total 5720_UNII-3 --- --- 4.07 ≤27.35 PASS 11AX20-CDD Ant2 5720_UNII-3 -0.75 0.07 -0.68 ≤30.00 PASS 11AX20-CDD Ant1 5745 1.99 0.04 2.03 ≤30.00 PASS 11AX20-CDD Ant2 5745 1.67 0.04 1.71 ≤30.00 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 103 of 138 FCC ID:2AMM6EWN-8852BSN3DB TB-RF-074-1.0 11AX20-CDD total 5745 --- --- 4.88 ≤27.35 PASS 11AX20-CDD Ant1 5785 1.61 0.07 1.68 ≤30.00 PASS 11AX20-CDD Ant2 5785 1.85 0.07 1.92 ≤30.00 PASS 11AX20-CDD total 5785 --- --- 4.81 ≤27.35 PASS 11AX20-CDD Ant1 5825 1.58 0.07 1.65 ≤30.00 PASS 11AX20-CDD Ant2 5825 1.86 0.05 1.91 ≤30.00 PASS 11AX20-CDD total 5825 --- --- 4.79 ≤27.35 PASS 11AX40-CDD Ant1 5190 0.61 0.08 0.69 ≤11.00 PASS 11AX40-CDD Ant2 5190 0.89 0.08 0.97 ≤11.00 PASS 11AX40-CDD total 5190 --- --- 3.84 ≤9.22 PASS 11AX40-CDD Ant1 5230 0.32 0.13 0.45 ≤11.00 PASS 11AX40-CDD Ant2 5230 0.41 0.13 0.54 ≤11.00 PASS 11AX40-CDD total 5230 --- --- 3.51 ≤9.22 PASS 11AX40-CDD Ant1 5270 0.62 0.08 0.70 ≤11.00 PASS 11AX40-CDD Ant2 5270 0.61 0.08 0.69 ≤11.00 PASS 11AX40-CDD total 5270 --- --- 3.71 ≤8.61 PASS 11AX40-CDD Ant…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202501-0081-17 Page: 76 of 138 FCC ID:2AMM6EWN-8852BSN3…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bin Lin(Product Design Engineer)
[email protected]Fax: +86 15197269372

Technical Contact

Luxshare-ICT IncKyle Liu
[email protected]

480 N.McCarthy Blvd #280 · Milpitas, California, 95035 · United States

Test Firm

Intertek Testing Services Shenzhen Ltd. Longhua BrHolly Ou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz70.00 mW
215E5.26 GHz - 5.32 GHz66.40 mW
315E5.50 GHz - 5.72 GHz67.60 mW
415E5.75 GHz - 5.83 GHz89.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Luxshare Precision Industry Co., Ltd.

2AYYS-HS2706

Wireless Headset

Aug 18, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AYYS-HS2704

Wireless Headset

May 26, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AYYS-WS137K4Y

WS137K4

Jan 28, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
onn. 4K Pro Streaming Device / Google TV - FCC ID 2AYYS-ORPK4VTG - Luxshare Precision Industry Co., Ltd.
2AYYS-ORPK4VTG

onn. 4K Pro Streaming Device / Google TV

Jan 14, 2024

Equipment Class

DTS - Digital Transmission System
onn. Full HD Streaming Device Google TV - FCC ID 2AYYS-8822K2VTG - Luxshare Precision Industry Co., Ltd.
2AYYS-8822K2VTG

onn. Full HD Streaming Device Google TV

Jun 30, 2023

Equipment Class

DTS - Digital Transmission System