2AZ2X-M502DBlood pressure monitor

Guangzhou Daxin Health Technology Co., Ltd
Blood pressure monitor - FCC ID 2AZ2X-M502D - Guangzhou Daxin Health Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 19, 2026
Application Purpose
Original Equipment
Equipment Note
Blood pressure monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangzhou Daxin Health Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

■Thank you for choosing our Blood Pressure Monitor. ■For the purpose of proper using and maintaining the Blood Pressure Monitor, please read this instruction completely before operating. ■Please keep this instruction manual safe for future use. ■Illustrations in this manual are for reference only. PA-52 User Manual Blood Pressure Meter Document Number: PS-M502C-01 Instruction Manual Version: V1.0 Issued Date: August 16, 2023 Software Version: V1.0 Blood pressure monitor Applicable model M501A、M502D、M502A Severe serious blood circulation obstacle, blood disease patients, please use under the guidance of doctors This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. Please control the pressure within 300mmHg(40kPa). -Otherwise the arm may be congestion or numbness This product is only for human body blood pressure measurement. Please use the special-purpose cuff. -Otherwise it can’t accurately measure blood pressure 1) Wrap the cuff 2) Correct posture 3) Measuring blood pressure -In order to correct blood pressure management, please measure the blood pressure at the same time every day. - Propose to measure your blood pressure an hour after getting up ,or before sleeping Measurement preparation To assure the correct use of the product, basic safety measures should always be followed including the note and cautions listed in this instruction manual. Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. Warning: Warning signs, graphic and their meanings Warning signe Symbol definitionse Warning Caution The warning statements in this manual identify conditions or practices that could lead to ilness, injury, or death. The caution statements in this manual identify conditions or practices that could result in damage to the equipment or other property, or loss of data. Degree of protection against harmful ingress of particulate matter and water Do not dispose of this product in municipal waste. Collection of such waste separately for special treatment Is necessary Serial number Production Date The package should be protected from rain The package contains fragile products, please handle with care Transport package should be upright Batch The maximum stacking layer of the same package, 5 means the layer limit This item is compliant with the Medical Device Directive 93/42/EEC of June 14,1993, a directive of the European Economiccommunity Authorized Representative in the European Community / European Union: Indicates the authorized representative in the European Community / European Union Manufacturer Refer to instruction manual/booklet Type BF Intended use This product can measure human diastolic blood pressure, systolic blood pressure, and pulse using the oscilloscope method, and its values are for diagnostic reference only. Applicable population: adults. Contraindications: None Location of use: hospital, home Operating principle By using air pressure to compress local arteries and change pressure, blood flow through blood vessels has a certain oscillation wave. Based on the changes in the oscillation wave, the detected pressure and fluctuation also change accordingly. Based on the accumulated experience of software algorithms, the diastolic pressure, systolic pressure, and pulse of the human body are obtained. 21 34 Don’t use the mobile phone near the product . Don’t dismantle or repair ,renovation the main body of the blood pressure or cuff. Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit. If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. If battery fluid should get in your skin or your clothes, immediately rinse with plenty of clean water. Don’t install the wrong battery positive and negative. When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Long time no using(more than 3 months) , please take out the batteries. Dispose of the battery, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental Pollution. Don’t mix the new and old battery ,or different type of battery. Do not use the device for any purpose other than measuring blood pressure. Do not disassemble the monitor or arm cuff. Doing so may cause inaccurate readings. Do not use in a humid environment or a location where water may splash onto the device. Doing so may damage the : device. Caution: When DC5V powered via USB only used IEC 60601-1 approved adapter witch meets 2MOPP If other Cuff and dry batteries are used, it may result in inaccurate measurement values. If other adapters that do not comply with IEC 60601-1 are used, there may be a risk of electric shock. The minimum storage temperature between two uses and the time required to heat up to the int ended use is half an hour The maximum storage temperature between two uses cools down to half an hour before preparation for use The product isn’t int ended for self-use in public areas. This product may result in inaccurate measurement values under extreme temperature, humidity, and height conditions The arm strap used in this product has passed the biocompatibility test, but it is not ruled out that there may be an allergic risk when used by multiple people. If accidental sensitization occurs, please consult your doctor. Do not operate the device in a moving vehicle e.g. car, airplane, boat. Do not excessively crease the arm cuff. Do not drop the device or subject it to strong shocks or vibrations. Do not service or do any maintenance work while the device is in use. The product are all p


Text truncated - open the document above for the full version.

Attestation Statements

* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. SC5124404 U.S. Agent Designation for Service of Process - Certification Attestation Letter 12/24/2025 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2AZ2X-M502D FRN of applicant: 0030964126 Per section 2.911(d)(7) of the FCC rules, Guangzhou Daxin Health Technology Co.,Ltd. FRN:0030964126(“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016 Contact Person: Michael Chan Tel: +1 626 366 4358 Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Julie Zhu Title: Sales Director Company Name: Guangzhou Daxin Health Technology Co.,Ltd. Date: 12/24/2025 Signed: Printed name: Michael Chan Title: Technical Director Company Name: Global Product Services and Consultation LLC Date: 12/24/2025

Attestation Statements

GuangzhouDaxinHealthTechnologyCo.,Ltd. CoveredEquipmentCertificationAttestationLetter 12/24/2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA ATTN.:ReviewingEngineer FCCID: 2AZ2X-M502D GuangzhouDaxinHealthTechnologyCo.,Ltd.(“theapplicant”)certifiesthattheequipment forwhichauthorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. GuangzhouDaxinHealthTechnologyCo.,Ltd..(“theapplicant”)certifiesthat,asofthedate ofthefilingoftheapplication,theapplicantisnotidentifiedontheCoveredList(asa specificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing “covered”equipment. GuangzhouDaxinHealthTechnologyCo.,Ltd.(“theapplicant”)certifiesthattheequipment forwhichauthorizationissoughtdoesnotincludecybersecurityoranti-virussoftware producedorprovidedbyKasperskyLab,Inc.oranyofitssuccessorsandassignees, includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Signed: Printedname:JulieZhu Title:SalesDirector CompanyName:GuangzhouDaxinHealthTechnologyCo.,Ltd. Date:12/24/2025

Cover Letter(s)

DATE:2025/12/24 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeComplianceTesting,LLCtoactonourbehalfinallmatters relatingtoapplicationforequipmentauthorization,includingthesigningofalldocumentsrelatingto thesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothedenialof benefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21 U.S.C.853(a). Sincerely, <Signature> NameJulieZhu Title  SalesDirector CompanyGuangzhouDaxinHealthTechnologyCo.,Ltd.

Cover Letter(s)

DATE2025/12/24 EquipmentAutorisationDivision FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 FCCID:2AZ2X-M502D ProductName:Bloodpressuremonitor RequestforConfidentiality PursuanttoSections0.457and0.459ofthecommission’srules,weherebyrequestthat thefollowingdocumentsbeheldconfidential: (Listherethedocumentsforwhichyouareseekingconfidentiality–forexample...)  Schematics Blockdiagram  Operationdescription Thesematerialscontaintradesecretsandproprietaryinformationandarenot customarilyreleasedtothepublic.Thepublicdisclosureofthisinformationmightbe harmfultothecompanyandprovideunjustifiedbenefitstoourcompetitors. <Signature> NameJulieZhu Title  SalesDirector Company  GuangzhouDaxinHealthTechnologyCo.,Ltd.

External Photos

ModelNo.: M502D

Internal Photos

ModelNo.: M502D

RF Exposure Info

Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. RFExposure Applicant:GuangzhouDaxinHealthTechnologyCo.,Ltd. Address: Room810,No.1,Yichuangstreet,HuangpuDistrict, Guangzhou(China-SingaporeGuangzhouKnowledge City) ProductName:Bloodpressuremonitor BrandMark:DAXIN Model:M502D Seriesmodel:M501A/M502A ReportNumber:BLA-EMC-202510-A7103 FCCID:2AZ2X-M502D DateofReceipt:Oct.27,2025 DateofTest:Oct.30,2025toNov.06,2025 TestStandard: 47CFRPart15,Part1.1307 47CFRPart15,Part2.1093 KDB447498D04GeneralRFExposureGuidancev01 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:Nov.07,2025 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Address: BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China ReportNo.:BLA-EMC-202510-A7103 Page 2 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 TableofContents 1Generalinformation......................................................................................................................................................4 1.1Generalinformation.................................................................................................................................................4 1.2GeneraldescriptionofEUT.....................................................................................................................................4 2Laboratoryandaccreditations....................................................................................................................................5 3RFExposureComplianceRequirement.....................................................................................................................6 3.1StandardRequirement............................................................................................................................................6 3.2Limits.......................................................................................................................................................................6 3.3Result.......................................................................................................................................................................7 ReportNo.:BLA-EMC-202510-A7103 Page 3 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 ReviseRecord VersionNo.DateDescription 01Nov.07,2025Original ReportNo.:BLA-EMC-202510-A7103 Page 4 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 1Generalinformation 1.1Generalinformation ApplicantGuangzhouDaxinHealthTechnologyCo.,Ltd. Address Room810,No.1,Yichuangstreet,HuangpuDistrict,Guangzhou (China-SingaporeGuangzhouKnowledgeCity) ManufacturerGuangzhouDaxinHealthTechnologyCo.,Ltd. Address Room810,No.1,Yichuangstreet,HuangpuDistrict,Guangzhou (China-SingaporeGuangzhouKnowledgeCity) 1.2GeneraldescriptionofEUT ProductnameBloodpressuremonitor Modelno.M502D SeriesmodelM501A/M502A DifferencesofSeries model TheModelofM501A/M502A/M502D.Theirelectricalcircuitdesign layout,componentsusedandinternalwiringareidentical,Onlythe modelname,pressbutton.backlightcolor. Powersupplyoradapter information 4Alkaline1.5Vbatteries(AAA),DC6.0V:DC:5V/1A,USBport HardwareversionePA-20B4V1.0 SoftwareversionePA-20B4V1.0 Engineersampleno.BLA-EMC-202510-A71 Note:Foramoredetaileddescription,pleaserefertoSpecificationorUser’sManualsuppliedby theapplicantand/ormanufacturer. ForBLE OperationFrequency2402MHz-2480MHz ModulationTypeGFSK Ratedata1Mbps ChannelSpacing2MHz NumberofChannels40 AntennaTypePCBantenna AntennaGain2.43dBi(Providedbycustomer) ReportNo.:BLA-EMC-202510-A7103 Page 5 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 2Laboratoryandaccreditations Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: FCC Companyname:BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Address: BuildingC,No.107,ShihuanRoad,ShiyanSub-District,Baoan District,Shenzhen,GuangdongProvince,China A2LACert.No.:5071.01 FCCDesignationNo.:CN1252 TestFirmRegistrationNumber:923526 Telephone:+86-755-28682673 FAX:+86-755-28682673 ReportNo.:BLA-EMC-202510-A7103 Page 6 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 3RFExposureComplianceRequirement 3.1StandardRequirement Accordingto447498D04InterimGeneralRFExposureGuidancev01 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurement ornumericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThreshold condition,listedbelow,issatisfied. 3.2Limits ReportNo.:BLA-EMC-202510-A7103 Page 7 of 7 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.1 3.3Result CalculatedResultandLimit(WORSECASEISASBELOW) Mode Frequency (MHz) MaxOutput power(dBm) MaxOutput power(mW) Ant gain (dBi) Evaluation ERP(dBm) Evaluation ERP(mW) Limitof Pth(mW) Result BLE1M24021.8281.522.432.1081.622.79Pass ERP=MaxOutputpower+Antgain-2.15 ComplywithRFexposureexemptionlimit. ----ENDOFREPORT---- Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,theresult(s)showninthisreportrefer onlytothesample(s)tested.WithoutwrittenapprovalofBlueAsia,thisreportcan’tbereprodu


Text truncated - open the document above for the full version.

Test Report

Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. TestReport Applicant:GuangzhouDaxinHealthTechnologyCo.,Ltd. Address: Room810,No.1,Yichuangstreet,HuangpuDistrict, Guangzhou(China-SingaporeGuangzhou KnowledgeCity) ProductName:Bloodpressuremonitor BrandMark:DAXIN Model:M502D Seriesmodel:M501A/M502A ReportNumber:BLA-EMC-202510-A7102 FCCID:2AZ2X-M502D DateofReceipt:Oct.27,2025 DateofTest:Oct.30,2025toNov.06,2025 TestStandard:47CFRPart15,SubpartC15.247 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:Nov.07,2025 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Address:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China ReportNo.:BLA-EMC-202510-A7102 Page 2 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 TableofContents 1Generalinformation......................................................................................................................................................5 1.1Generalinformation.................................................................................................................................................5 1.2GeneraldescriptionofEUT.....................................................................................................................................5 2Testsummary................................................................................................................................................................6 3TestConfiguration........................................................................................................................................................7 3.1Testmode................................................................................................................................................................7 3.2OperationFrequencyeachofchannel....................................................................................................................7 3.3Testchannel.............................................................................................................................................................7 3.4Auxiliaryequipment.................................................................................................................................................8 3.5Testenvironment.....................................................................................................................................................8 4Laboratoryinformation................................................................................................................................................9 4.1Laboratoryandaccreditations.................................................................................................................................9 4.2Measurementuncertainty........................................................................................................................................9 5Testequipment............................................................................................................................................................10 6Testresult....................................................................................................................................................................12 6.1Antennarequirement.............................................................................................................................................12 6.2ConductedemissionsatACpowerline(150kHz-30MHz)..................................................................................13 6.3ConductedpeakoutputPower..............................................................................................................................17 6.4Minimum6dBbandwidth.......................................................................................................................................18 6.5Powerspectrumdensity........................................................................................................................................19 6.6ConductedBandEdgesMeasurement.................................................................................................................20 6.7Conductedspuriousemissions.............................................................................................................................22 6.8Radiatedspuriousemissions................................................................................................................................24 6.9Radiatedemissionswhichfallintherestrictedbands..........................................................................................35 7AppendixA..................................................................................................................................................................42 7.1MaximumPKConductedOutputPower...............................................................................................................42 7.2-6dBBandwidth.....................................................................................................................................................44 7.3OccupiedChannelBandwidth...............................................................................................................................46 7.4MaximumPowerSpectralDensityLevel...............................................................................................................48 7.5BandEdge................................


Text truncated - open the document above for the full version.

Test Report

ReportNo.:BLA-EMC-202510-A7102 Page 21 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.6.3Testdata Pass:PleaserefertoappendixAfordetails ReportNo.:BLA-EMC-202510-A7102 Page 22 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.7Conductedspuriousemissions TestStandard47CFRPart15,SubpartC15.247(d) TestMethodANSIC63.10-2020+Cor.1-2023Clause11.11 TestMode(Pre-Scan)TX TestMode(FinalTest)TX 6.7.1Limit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumordigitally modulatedintentionalradiatorisoperating,theradiofrequencypowerthatisproducedbythe intentionalradiatorshallbeatleast20dBbelowthatinthe100kHzbandwidthwithinthebandthat containsthehighestlevelofthedesiredpower,basedoneitheranRFconductedoraradiated measurement,providedthetransmitterdemonstratescompliancewiththepeakconductedpower limits. IfthetransmittercomplieswiththeconductedpowerlimitsbasedontheuseofRMSaveraging overatimeinterval,aspermittedunderparagraph(b)(3)ofthissection,theattenuationrequired underthisparagraphshallbe30dBinsteadof20dB. Attenuationbelowthegenerallimitsspecifiedin§15.209(a)isnotrequired. Inaddition,radiatedemissionswhichfallintherestrictedbands,asdefinedin§15.205(a),must alsocomplywiththeradiatedemissionlimitsspecifiedin§15.209(a)(see§15.205(c)). 6.7.2Testsetup ReportNo.:BLA-EMC-202510-A7102 Page 23 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.7.3Testdata Pass:PleaserefertoappendixAfordetails ReportNo.:BLA-EMC-202510-A7102 Page 24 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8Radiatedspuriousemissions TestStandard47CFRPart15,SubpartC15.247(d) TestMethodANSIC63.10-2020+Cor.1-2023Clause6.4,6.5,6.6 TestMode(Pre-Scan)TX TestMode(FinalTest)TX 6.8.1Limit Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.4902400/F(kHz)300 0.490-1.70524000/F(kHz)30 1.705-30.03030 30-881003 88-2161503 216-9602003 Above9605003 Remark:TheemissionlimitsshownintheabovetablearebasedonmeasurementsemployingaCISPR quasi-peakdetectorexceptforthefrequencybands9-90kHz,110-490kHzandabove1000MHz.Radiated emissionlimitsinthesethreebandsarebasedonmeasurementsemployinganaveragedetector,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation. ReportNo.:BLA-EMC-202510-A7102 Page 25 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.2Testsetup Below1GHz 30MHz-1GHz Above1GHz ReportNo.:BLA-EMC-202510-A7102 Page 26 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.3Procedure a)Forbelow1GHz,theEUTwasplacedonthetopofarotatingtable0.8metersabovethegroundat a3or10metersemi-anechoicchamber.Thetablewasrotated360degreestodeterminethe positionofthehighestradiation. b)Forabove1GHz,theEUTwasplacedonthetopofarotatingtable1.5metersabovethegroundat a3meterfully-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionof thehighestradiation. c)TheEUTwasset3or10metersawayfromtheinterference-receivingantenna,whichwasmounted onthetopofavariable-heightantennatower. d)Theantennaheightisvariedfromonemetertofourmetersabovethegroundtodeterminethe maximumvalueofthefieldstrength.Bothhorizontalandverticalpolarizationsoftheantennaare settomakethemeasurement. e)Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentheantennawas tunedtoheightsfrom1meterto4meters(forthetestfrequencyofbelow30MHz,theantennawas tunedtoheights1meter)andtherotatabletablewasturnedfrom0degreesto360degreestofind themaximumreading. f)Thetest-receiversystemwassettoPeakDetectFunctionandSpecifiedBandwidthwithMaximum HoldMode. g)IftheemissionleveloftheEUTinpeakmodewas10dBlowerthanthelimitspecified,thentesting couldbestoppedandthepeakvaluesoftheEUTwouldbereported.Otherwisetheemissionsthat didnothave10dBmarginwouldbere-testedonebyoneusingpeak,quasi-peakoraverage methodasspecifiedandthenreportedinadatasheet. h)TesttheEUTinthelowestchannel,themiddlechannel,thehighestchannel. i)TheradiationmeasurementsareperformedinX,Y,ZaxispositioningforTransmittingmode,and foundtheXaxispositioningwhichitistheworstcase. j)Repeataboveproceduresuntilallfrequenciesmeasuredwascomplete. Note1:Scanfrom9kHzto25GHz,thedisturbanceabove12.75GHzandbelow30MHzwasverylow.Thepoints markedonaboveplotsarethehighestemissionscouldbefoundwhentesting,soonlyabovepointshadbeen displayed.Theamplitudeofspuriousemissionsfromtheradiatorwhichareattenuatedmorethan20dBbelowthe limitneednotbereported.Fundamentalfrequencyisblockedbyfilter,andonlyspuriousemissionisshown. Note2:Forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation.Fortheemissionswhosepeaklevelislowerthantheaveragelimit,only thepeakmeasurementisshowninthereport. Note3:ThefieldstrengthiscalculatedbyaddingtheAntennaFactor,CableFactor&Preamplifier.Thebasic equationwithasamplecalculationisasfollows: Level(dBuV)=Reading(dBuV)+Factor(dB/m) ReportNo.:BLA-EMC-202510-A7102 Page 27 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.4Testdata Below1GHz [Testmode:TX];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202510-A7102 Page 28 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TX];[Polarity:Vertical] TestResult:Pass testshavebeenconductedonBLE1Mbpsmodes,coveringlow,mediumandhighchannels.Onlytheworst 1Mbps/l


Text truncated - open the document above for the full version.

Test Report

ReportNo.:BLA-EMC-202510-A7102 Page 41 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202510-A7102 Page 42 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 7AppendixA 7.1MaximumPKConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant11.82830Pass NVNTBLE1M2442Ant11.47830Pass NVNTBLE1M2480Ant11.46630Pass PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202510-A7102 Page 43 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 PowerNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202510-A7102 Page 44 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 7.2-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7060.5Pass NVNTBLE1M2442Ant10.7180.5Pass NVNTBLE1M2480Ant10.6920.5Pass -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202510-A7102 Page 45 of 59 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 


Text truncated - open the document above for the full version.

Contact Information

Applicant

Julie Zhu(Sales Director)
[email protected]Fax: 0769-89060018

Technical Contact

Global Product Services and Consultation LLCMichael Chan
[email protected]

328 W Palm Ave. · Monrovia, California, 91016 · United States

Test Firm

BLUEASIA TECHNICAL SERVICES (SHENZHEN) CO., LTD.Blue Zheng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.52 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Guangzhou Daxin Health Technology Co., Ltd

Eye Massager - FCC ID 2AZ2X-DX301 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X-DX301

Eye Massager

Jul 31, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Body composition scale - FCC ID 2AZ2X804W - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X804W

Body composition scale

Jul 28, 2021

Equipment Class

DTS - Digital Transmission System
Body composition scale - FCC ID 2AZ2X655B4 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X655B4

Body composition scale

Jul 12, 2021

Equipment Class

DTS - Digital Transmission System
Body composition scale - FCC ID 2AZ2X802B4 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X802B4

Body composition scale

Jul 12, 2021

Equipment Class

DTS - Digital Transmission System