FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Daxin Health Technology Co., Ltd/
  3. 2AZ2X804W

2AZ2X804WBody composition scale

Guangzhou Daxin Health Technology Co., Ltd
Body composition scale - FCC ID 2AZ2X804W - Guangzhou Daxin Health Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 28, 2021
Application Purpose
Original Equipment
Date of Application
Jul 28, 2021
Equipment Note
Body composition scale
Frequency Range
2412.00000000 - 2462.00000000
Company
Guangzhou Daxin Health Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GN-WA005-199 说明书,成品尺寸:145x210mm,展开尺寸:290x210mm,材质:120g书写纸,骑马钉装订,共16P Contents About The Smart Wi-Fi Scale 2 Register an Account on your Geeni App 3 Connect Scale to Geeni App 4-5 Measuring6-7 Body Composition Index8-10 Troubleshooting and Specification11 Thank you for purchasing your GEENI smart home product. Get started using your new devices by downloading Geeni, one convenient app that manages everything straight from your phone or tablet. Easily connect to your home Wi-Fi and control multiple devices from the touch of your fingertips. WARNING: Do not use this product if you have a pacemaker or other im- planted medical device, or are pregnant. Always contact your physician. Not intended for use by children under 13 years of age. Slippery when wet. Do not use if cracks are present on the glass surface. Keep out of reach of infants and toddlers. Users with disabilities must receive assistance from others. Always consult with your doctor for guidance on weight loss and exercise therapy. Do not allow the scale to be dropped. Do not disassemble, repair, or modify this product yourself. Do not mix old and new batteries. Remove batteries when not in use for a long time. (more than three months) Do not stand on the edge of the glass. Always operate the scale barefoot only. Not for professional use. Support: If you encounter any issues, please call (888) 232-3143 (Toll Free) or visit support.mygeeni.com for help. Support is available seven days a week. To explore our full selection of products, visit us at: www.mygeeni.com © 2019 Merkury Innovations • 45 Broadway 3rd FL, New York NY 10006. The illustrated product and specifications may differ slightly from those supplied. Geeni is a trademark of Merkury Innovations LLC. iPhone, Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. iOS is a registered trademark of Cisco in the U.S. and other countries and is used under license. All other trademarks and trade names are those of their respective owners. Made in China FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference , and (2) this device must accept any interference received,including interference that may cause undesired operation. N o t e : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form. 10 6Body Composition Index BODY WATER PERCENTAGE: Men tend to have less body water than women and it decreases with age. People with more body fat have less water. During the day, your water rate changes as you drink water, perform physical activity etc. BODY COMPOSITION SCORE: Based on the comprehensive evaluation of each component of the body. BMI, Fat Percentage, and Muscle rate are leading factors in the calculation while the additional measurements factor for the rest. PROTEIN CONTENT: Protein is an important component of all cells and tissues in the body and strongly correlated with muscle mass. LEAN BODY MASS: The weight of the body that removes fat. VISCERAL FAT GRADE: The fat attached to the visceral gap in the abdominal cavity is called visceral fat. This is expressed in number grades; level 10 is equivalent to a visceral fat area of 100 square centimeters. Excessive Visceral Fat can lead to high blood lipids, arteriosclerosis, hypertension, diabetes and other related diseases. Male Healthy Range Malnutrition Minor WarningUnhealthy Normal Range Dangerous Range Over Nutrition Female Normal range of body water 45 - 60% 1 - 45 16% or Less 5 - 9.510-14.5 16% - 20% 15+ 20+% 50 - 65% 3 2Download the Geeni app from App Store or Google Play. 3Register an Account on Your Geeni App. STEP 1. Enter your mobile phone number or email address. STEP 2. Enter the verification code and create a password. STEP 3. Login to the app 4 4 Connect STEP 1. In the Geeni app, on the top corner of the Devices screen, click (+). Choose “Smart Health“. STEP 2. Make sure the Wi-Fi indicator on the Scale is flashing rapidly, indicating the device is ready to connect using Easy Mode. If not, press and hold The Unit Conversion Button for 3 seconds until the Wi-Fi indicator is flashing rapidly, then press “Next Step”. STEP 3. Enter your Wi-Fi network and password. STEP 4. The Geeni app will try to connect your device. NOTE: Geeni can’t connect to 5GHz networks. *I…

Text truncated - open the document above for the full version.

Cover Letter(s)

Guangzhou Daxin Health Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AZ2X804W Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description, Block Diagram Operation Description schematic diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, June 29, 2021 minjian Jiang / General Manager Guangzhou Daxin Health Technology Co., Ltd.

Cover Letter(s)

Guangzhou Daxin Health Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: June 29, 2021 SUBJECT: FCC Application for FCC ID: 2AZ2X804W To Whom It May Concern: We, the undersigned, hereby authorize Lisa Wang at EMTEK (SHENZHEN) CO., LTD.on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by EMTEK (SHENZHEN) CO., LTD. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, minjian Jiang / General Manager Guangzhou Daxin Health Technology Co., Ltd.

External Photos

External Photos

ID Label/Location Info

刀模设计: 日期: 平面设计: 审核者: 批准者: 1 CHECKED BY: APPROVED BY: DESIGNED BY: DESIGNED BY: TOLERANCE/公差 MATERIAL: SIZE: SCALE: QTY: VER: TUTKE: MODEL/NO: DATE: 日期: DATE: 日期: DATE: 日期: DATE: FILE NO.: V1.0 S N:B20071705159240001 Size: 75x45mm,材质: PVC+光膜,跳码 804W (GN-WA005) 产品贴纸 编码规则(18位): 9位 订单号码 (随订单变化) 5位 客户PO号 4位流水号 0001-1010 (随订单数量变化) Model No.: GN-WA005 (eF-804W) FCC ID: Rating: 4xAAA batteries,6V SN: B20071705159240001 Manufacturer: Guangzhou Daxin Health Technology Co., Ltd. Made in China (01)06947468545619 (11)200804(10)20071705 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful int erference , and (2) this device must accept any int erference received, including int erference that may cause undesired operation. Model No.: GN-WA005 (eF-804W) FCC ID: 2AZ2X804W Rating: 4xAAA batteries,6V SN: B20071705159240001 Manufacturer: Guangzhou Daxin Health Technology Co., Ltd. Made in China (01)06947468545619 (11)200804(10)20071705 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this devicemay not cause harmful int erference , and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Internal Photos 2.4G WIFI ANT

RF Exposure Info

FCC ID: 2AZ2X804W Portable device According to §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz; Power and distance are rounded to the nearest mW and mm before calculation; The result is rounded to one decimal place for comparison; The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. According to user manual, we use 50mm as separation distance to calculate. WLAN 2.4G ANT first toe first toe 50mm 50mm Maximum measured transmitter power: Mode Max. Tune-up Power (dBm) Max. Tune-up Power (mW) RearFace Ant. to extremity (mm) Calculated Result Require SAR Testing? WLAN 2.4G 21.0 125.89 50 4.0 No Conclusion: For the max result : 4.0 ≤ 7.5 for 10-g SAR extremity SAR, No SAR is required. Signature: Date: 2021.7.20 NAME AND TITLE (Please print or type): Lisa Wang/Manager COMPANY (Please print or type): Shenzhen EMTEK Co.,Ltd./Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China

Test Report

Report No.ES210506020W Page 1 of 46 Ver.1.0 TEST REPORT Product Name : Body Composition Scale Model Number : ef-804W FCC ID : 2AZ2X804W Prepared for : Guangzhou Daxin Health Technology Co., Ltd. Address : Room 810, No.1, Yichuang Street, Huangpu District, Guangzhou, Guangdong. Prepared by : EMTEK (SHENZHEN) CO., LTD. Address : Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Number : ES210506020W Date(s) of Tests : May 29, 2021 to June 03, 2021 Date of issue : June 17, 2021 $二维码$ Report No.ES210506020W Page 2 of 46 Ver.1.0 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 EUT TECHNICAL DESCRIPTION .................................................................................................................... 4 3 SUMMARY OF TEST RESULT ........................................................................................................................... 5 4 TEST METHODOLOGY ...................................................................................................................................... 6 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................................ 6 4.2 MEASUREMENT EQUIPMENT USED ....................................................................................................... 6 4.3 DESCRIPTION OF TEST MODES ................................................................................................................ 7 5 FACILITIES AND ACCREDITATIONS ............................................................................................................. 8 5.1 FACILITIES.................................................................................................................................................... 8 5.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................ 8 6 TEST SYSTEM UNCERTAINTY ........................................................................................................................ 9 7 SETUP OF EQUIPMENT UNDER TEST ......................................................................................................... 10 7.1 RADIO FREQUENCY TEST SETUP 1 ........................................................................................................ 10 7.2 RADIO FREQUENCY TEST SETUP 2 ........................................................................................................ 10 7.3 CONDUCTED EMISSION TEST SETUP .................................................................................................... 11 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM .................................................................... 12 7.5 SUPPORT EQUIPMENT.............................................................................................................................. 12 8 TEST REQUIREMENTS .................................................................................................................................... 13 8.1 DTS (6DB) BANDWIDTH ........................................................................................................................... 13 8.2 MAXIMUM PEAK CONDUCTED OUTPUT POWER .............................................................................. 19 8.3 MAXIMUM POWER SPECTRAL DENSITY ............................................................................................. 21 8.4 UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS ............................................ 27 8.5 RADIATED SPURIOUS EMISSION ........................................................................................................... 32 8.6 CONDUCTED EMISSIONS TEST .............................................................................................................. 44 8.7 ANTENNA APPLICATION ......................................................................................................................... 45 Report No.ES210506020W Page 3 of 46 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant : Guangzhou Daxin Health Technology Co., Ltd. Address : Room 810, No.1, Yichuang Street, Huangpu District, Guangzhou, Guangdong. Manufacturer : Guangzhou Daxin Health Technology Co., Ltd. Address : Room 810, No.1, Yichuang Street, Huangpu District, Guangzhou, Guangdong. EUT : Body Composition Scale Model Name : ef-804W Trademark : N/A Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C PASS The above equipment was tested by EMTEK (SHENZHEN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2and Part 15.247 The test results of this report relate only to the tested sample identified in this report. Date of Test : May 29, 2021 to June 03, 2021 Prepared by : Lance Li/Editor Reviewer : Sewen Guo /Supervisor Approve & Authorized Signer : Lisa Wang/Manager Report No.ES210506020W Page 4 of 46 Ver.1.0 2 EUT TECHNICAL DESCRIPTION Note: for more details, please refer to the User’s manual of the EUT. Characteristics Description Product: Body Composition Scale Model Number: ef-804W Sample number: 1# IEEE 802.11 WLAN Mode Supported 802.11b 802.11g 802.11n(20MHz channel bandwidth) Modulation DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QPSK/16QAM/64QAM for 802.11g/n; Operating Frequency Range 2412-2462MHz for 802.11b/g/n(HT20); Number of Channels 11 channels for 802.11b/g n(HT20); Transmit Power Max 20.80 dBm Antenna Type PCB Antenna Antenna Gain 0 dBi Power supply DC 6V( AAA 1.5V*4) Date of Received May 0…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOGRAPHS 1.1. Photos of Radiation Emission Measurement Spurious Emission Test Setup (Below 1GHz) Spurious Emission Test Setup (Above 1GHz)

Contact Information

Applicant

Jiang Minjian(General Manager)
[email protected]020-87378476Fax: 020-87378476

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]86 755 26954280

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz120.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output.

Other Applications from Guangzhou Daxin Health Technology Co., Ltd

Blood pressure monitor - FCC ID 2AZ2X-M502D - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X-M502D

Blood pressure monitor

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System
Eye Massager - FCC ID 2AZ2X-DX301 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X-DX301

Eye Massager

Jul 31, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Body composition scale - FCC ID 2AZ2X655B4 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X655B4

Body composition scale

Jul 12, 2021

Equipment Class

DTS - Digital Transmission System
Body composition scale - FCC ID 2AZ2X802B4 - Guangzhou Daxin Health Technology Co., Ltd
2AZ2X802B4

Body composition scale

Jul 12, 2021

Equipment Class

DTS - Digital Transmission System