Fujian EastWest Lifewit Technology Co.,LTD Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/20/2023 U.S. Agent Designation Fujian EastWest Lifewit Technology Co.,LTD acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AZNY-TSL60): Name and company of U.S. agent: EASTWEST ELECTRONIC COMMERCE CO US LIMITED Physical U.S. address of agent: 3500 South Dupont Highway Dover Delaware 19901 United States FRN of U.S. agent: 0033602186 Email address of U.S. agent: [email protected] EASTWEST ELECTRONIC COMMERCE CO US LIMITED acknowledges their obligation to accept service of process on behalf of Fujian EastWest Lifewit Technology Co.,LTD. Fujian EastWest Lifewit Technology Co.,LTD with the FRN 0030816284 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under Β§ 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Yanbing Li Product Director Fujian EastWest Lifewit Technology Co.,LTD Signature XUEFANG TANG Director EASTWEST ELECTRONIC COMMERCE CO US LIMITED 48_[mo del] US_Agent_2.911(d)(7) - U, V05
Page 1 of FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 1 FCC ID: 2AZNY-TSL60 IC: 30108-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Label and Location Size: L: 3.5cm*W: 3.0cm Label Location LED Strip Lights Model No.: TSL60 FCC ID: 2AZNY-TSL60 IC: 30108-TSL60
Page 1 of 2 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Antenna
Page 1 of 3 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : LED Strip Lights Test Model : TSL60 Additional Model No. : TSL10, TSL16, TSL30 Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : Input: 24V1.0A For AC Adapter Input: 100-240V~, 50/60Hz, 0.8A max Adapter Output: 24V1.0A Hardware Version : V2.0 Software Version : V3.0 Bluetooth Frequency Range : 2402MHz~2480MHz Channel Number : 40 channels for Bluetooth V4.2 (DTS) Channel Spacing : 2MHz for Bluetooth V4.2 (DTS) Modulation Type : GFSK for Bluetooth V4.2 (DTS) Bluetooth Version : V4.2 Antenna Description : PCB Antenna, 0dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Device Page 2 of 3 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commissionβs guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is β€ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1β2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cmΒ²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 β 3.0 3.0 β 30 30 β 300 300 β 1500 1500 β 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cmΒ²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 β 3.0 3.0 β 30 30 β 300 300 β 1500 1500 β 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4ΟRΒ² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna Page 3 of 3 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Internal/External Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Internal PCB Antenna 2400MHz-2500MHz 0dBi BLE Antenna 6. Conducted Power [BT LE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 00 2402 -0.10 19 2440 0.01 39 2480 0.21 7. Manufacturing Tolerance [BT LE] GFSK(Peak) Channel Channel 00 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance Β± (dB) 1.0 1.0 1.0 8. Measurement Results 8.1 Standalone MPE Evaluation As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained. [BT LE] Modulation Type Output power Antenna Gain (dBi) Antenna Gain (linear) MPE (mW/cm2) Mβ¦
Text truncated - open the document above for the full version.
Shenzhen Yingfeng Intelligent Technology Co., Ltd. Antenna specification Quick Reference Date Antenna Introduction Bluetooth antenna is directly mounted on the PCB board Frequenc Range 2402 ~ 2480MHz Ant. Port Input Pwr. (dBm) 0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm) -1.2 (Input pwr β loss pwr) Peak EIRP(dBm) 0 Directivity (dBi) 0 (all direction antenna) Efficiency (dB) 1.0% Gain (dBi) 0 (Avg Gain XY-plane) Maximum Power (dBm) 0 (XY-plane) Minimum Power (dBm) 0(XY-plane) Avg. Power (dBm) 0(XY-plane) Input Impendence(ohm) 50 Polarization Type V ertical & Horizontal V . S .W . R < 6 All the technical data and information contained herein are subject to change without prior notice Antenna Layout & module on the system board Shenzhen Yingfeng Intelligent Technology Co., Ltd. Antenna Gain Gain Table Unit in dBi @2.44GHz XY-plane XZ-plane YZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 0 0 0 0 0 0 0 Shenzhen Yingfeng Intelligent Technology Co., Ltd. Return Loss 3D radiation pattern diagram Shenzhen Yingfeng Intelligent Technology Co., Ltd. XY-plane XZ-plane YZ-plane
Page 1 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: LED Strip Lights Test Model: TSL60 Environmental Conditions Temperature: 23.8ο° C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Ling Zhu Page 2 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 DTS Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.712 2401.628 2402.340 0.5 PASS 2440 0.716 2439.624 2440.340 0.5 PASS 2480 0.720 2479.624 2480.344 0.5 PASS Page 3 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 4 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Occupied Channel Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0572 2401.4697 2402.5269 --- --- 2440 1.0596 2439.4684 2440.5280 --- --- 2480 1.0555 2479.4715 2480.5270 --- --- Page 6 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 7 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 -0.10 β€30 PASS 2440 0.01 β€30 PASS 2480 0.21 β€30 PASS EIRP TestMode Frequency (MHz) Maximum Peak Output Power [dBm] Antenna Gain Report EIRP Power(dBm) Limit[dBm] Verdict BLE_1M 2402 -0.10 0 -0.10 36 PASS 2440 0.01 0 0.01 36 PASS 2480 0.21 0 0.21 36 PASS Page 9 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 10 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -15.19 β€8.00 PASS 2440 -15.14 β€8.00 PASS 2480 -15 β€8.00 PASS Page 12 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 13 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 27 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcβ¦
Text truncated - open the document above for the full version.
Page 1 of 34 FCC ID: 2AZNY-TSL60 Report No.: LCSA063023161EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Fujian EastWest Lifewit Technology Co., LTD LED Strip Lights Test Model: TSL60 Additional Model No.: Please Refer to Page 6 Prepared for : Fujian EastWest Lifewit Technology Co., LTD Address : Rm 1201-1205, Bld 18, 2nd Phase of Innovation Park, no.7, Wulongjiang Mid-Ave, Fuzhou High-tech Zone, Fuzhou, Fujian Province Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : July 04, 2023 Number of tested samples : 2 Sample No. : A063023161-1, A063023161-2 Serial number : Prototype Date of Test : July 04, 2023 ~ July 14, 2023 Date of Report : July 17, 2023 Page 2 of 34 FCC ID: 2AZNY-TSL60 Report No.: LCSA063023161EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA063023161EA Date of Issue .................................. : July 17, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards β Partial application of Harmonised standards β‘ Other standard testing method β‘ Applicantβs Name ......................... : Fujian EastWest Lifewit Technology Co., LTD Address .......................................... : Rm 1201-1205, Bld 18, 2nd Phase of Innovation Park, no.7, Wulongjiang Mid-Ave, Fuzhou High-tech Zone, Fuzhou, Fujian Province Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : LED Strip Lights Trade Mark ..................................... : TONOR Test Model ...................................... : TSL60 Ratings ........................................... : Input: 24V1.0A For AC Adapter Input: 100-240V~, 50/60Hz, 0.8A max Adapter Output: 24V1.0A Result ............................................ : Positive Compiled by: Supervised by: Approved by: Kay Hu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 34 FCC ID: 2AZNY-TSL60 Report No.: LCSA063023161EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : TSL60 EUT......................................... : LED Strip Lights Applicant............................... : Fujian EastWest Lifewit Technology Co., LTD Address.................................. : Rm 1201-1205, Bld 18, 2nd Phase of Innovation Park, no.7, Wulongjiang Mid-Ave, Fuzhou High-tech Zone, Fuzhou, Fujian Province Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Fujian EastWest Lifewit Technology Co., LTD Address................................... : Rm 1201-1205, Bld 18, 2nd Phase of Innovation Park, no.7, Wulongjiang Mid-Ave, Fuzhou High-tech Zone, Fuzhou, Fujian Province Telephone............................... : / Fax.......................................... : / Factory................................... : Shenzhen Yingfeng Intelligent Technology Co., LTD Address................................... : Shenzhen Longgang District Bantian street new snow community on snow technology Building 8B, No.5, Chengyi Road Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA063023161EA July 17, 2023 Date of issue Page 4 of 34 FCC ID: 2AZNY-TSL60 Report No.: LCSA063023161EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 17, 2023 Initial Issue --- Page 5 of 34 FCC ID: 2AZNY-Tβ¦
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2AZNY-TSL60 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Test Setup Photo(s) of Conducted Emissions Measurement Fig. 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

Voice Amplifier
Equipment Class
DTS - Digital Transmission System
WIRELESS MICROPHONE
Equipment Class
TLD - Licensed LPAS Device
WIRELESS MICROPHONE
Equipment Class
TLD - Licensed LPAS Device
WIRELESS MICROPHONE
Equipment Class
TLD - Licensed LPAS Device
WIRELESS MICROPHONE
Equipment Class
TLD - Licensed LPAS Device