FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Blueiot (Beijing) Technology Co., Ltd./
  3. 2AZOM-UG2000ID

2AZOM-UG2000IDPositioning Device

Blueiot (Beijing) Technology Co., Ltd.
Positioning Device - FCC ID 2AZOM-UG2000ID - Blueiot (Beijing) Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 01, 2026
Application Purpose
Original Equipment
Equipment Note
Positioning Device
Frequency Range
2402.00000000 - 2480.00000000
Company
Blueiot (Beijing) Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Bluetooth Gateway UG2000-ID Blueiot (Beijing) Technology Co., Ltd. Confidential Information 2 Copyrigh Statement Copyright ©2020 Blueiot (Beijing) Technology Co., Ltd. All rights reserved. All content of this manual, including text, images, graphics, etc, is the exclusive property of Blueiot (Beijing) Technology Co., Ltd. No entity or individual is allowed to extract, reproduce, translate, or modify this manual, either in whole or in part, by any means without prior written consent. Unless otherwise agreed, no statements or warranties, explicit or implicit, are provided for this manual. Trademark Statement Blueiot (Beijing) Co., Ltd. is the rightful owner of “Blueiot” and other various registered trademarks, logos and trademark portfolios. Disclaimers ◼ Within the legal limits, products in this manual (hardware, software, etc.) are provided in their current state, potentially with defects, errors or malfunctions. The company gives no explicit or implicit warranties, and shall not be liable for any special, incidental, or indirect damages from using the product in this manual or other our company products. ◼ The company reserves the right to modify the product design, features and specifications without prior notice due to technological advancements. ◼ The “Blueiot” series products (hereinafter referred to as “the device”) provided by the company act as an auxiliary aid and is not intended to replace safety management systems, precautions or emergency responses for hazardous tasks, nor regulatory systems and measures in operational management. ◼ During the use of the device, operators should be reminded that the presence of assistance tools shall not reduce their safety awareness. Regular device inspections are required. If you encounter any problems, please don’t hesitate to contact us at [email protected] for prompt repairs or replacements. Blueiot (Beijing) Technology Co., Ltd. Confidential Information 3 Contents 1. Product Introduction ............................................................................................................... 4 1.1.Product Overview ................................................................................................................. 4 1.2. Functional Features ............................................................................................................. 4 2. Instructions for Use ................................................................................................................ 5 2.1.install .................................................................................................................................... 5 2.2.supply electricity .................................................................................................................. 6 2.3. Network Connection ........................................................................................................... 6 2.4 Network Configuration ........................................................................................................ 7 2.5. Server and Backup Server IPs ............................................................................................. 7 3. Maintenance and Care ............................................................................................................ 8 4. Precautions ............................................................................................................................. 8 5. Warranty Details .................................................................................................................... 8 Non-Warranty Regulations: ....................................................................................................... 8 Attachment: Specification Parameters ....................................................................................... 9 Blueiot (Beijing) Technology Co., Ltd. Confidential Information 4 1. Product Introduction 1.1.Product Overview UG2000-ID features continuous monitoring and reporting capabilities for Bluetooth broadcasts. Specially designed for indoor beacon and tag positioning devices, it uploads Bluetooth ranging and monitoring data from positioning terminals to the platform server via wired Ethernet . It boasts extensive coverage, low latency, high concurrency stability. The UG2000-ID universal Bluetooth gateway supports dual power supply via PoE/DC, Suitable for a wide range of indoor environments, it asset tracking as well as environmental data industries including healthcare, warehousing, transportation and manufacturing. 1.2. Functional Features Wide-area communication, supporting up to 180 meters coverage in open environments Extremely high label scanning capacity, with single-channel scanning capacity exceeding 300 broadcast packets per second The single gateway supports two mainstream Bluetooth positioning methods simultaneously: Beacon TAG three-point positioning and Bluetooth gateway RSSI positioning. and superior meets the requirements for personnel and collection. It serves as an ideal solution for Blueiot (Beijing) Technology Co., Ltd. Confidential Information 5 Supports label configuration, automatic content deduplication, and batch settings to facilitate rapid on-site deployment. 2. Instructions for Use 2.1.install The UG2000-ID gateway is typically installed as a ceiling-mounted unit; alternatively, it can be mounted using suspension or wall mounting methods depending on the specific structural characteristics of the buildings ceiling. The Bluetooth gateway captures Bluetooth signals, so it has strict requirements for installation location and surrounding environment: the gateway must be installed correctly with its front facing downward. It should not be installed vertically or at an angle. The Bluetooth gateway must not be obstructed, and its visible coverage area should be maximized. It is prohibited to install the Bluetooth gateway above obstructions such as ceilings (including metal mat…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Blueiot (Beijing) Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-08-26 FCC ID: 2AZOM-UG2000ID Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing Blueiot (Beijing) Technology Co., Ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Blueiot (Beijing) Technology Co., Ltd. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing Blueiot (Beijing) Technology Co., Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Applicant: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Contact Person: Liu jida Tel.: 15101154880 Email: [email protected] Sincerely, Signature:

Attestation Statements

Attestation Statements Date: 2026-08-26 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2AZOM-UG2000ID) Blueiot (Beijing) Technology Co., Ltd., the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated agent for service of process, Blueiot (Beijing) Technology Co., Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: Blueiot (Beijing) Technology Co., Ltd. Contact Name: Liu jida Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Telephone No: 15101154880 Email: [email protected] FRN: 0030825889 Signature: Liu jida Agent Information: Company Name:HOPEK CORPORATION INC Address:16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN:0034562900 Contact Name:YangyangXu Telephone No:561-875-9826 Email:[email protected] Signature: Yangyang Xu

Cover Letter(s)

Blueiot (Beijing) Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 26, 2026 Subject; Request for Confidentiality FCC ID: 2AZOM-UG2000ID To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Liu jida Title: Manager

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Blueiot (Beijing) Technology Co., Ltd. Date:2026-08-26 Product Model Number: UG2000-ID FCC ID:2AZOM-UG2000ID To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Liu jida Contact Listed on FCC Wesbite Title: Manager Email: [email protected] On behalf of: Blueiot (Beijing) Technology Co., Ltd.

External Photos

Page 1 of 5 Report No.: LGT26H017 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 5 Report No.: LGT26H017 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 5 Report No.: LGT26H017 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 5 Report No.: LGT26H017 Appendix - External Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 5 Report No.: LGT26H017 Appendix - External Photographs of EUT Constructional Details Photo 9 Photo 10

ID Label/Location Info

Label Size: 21*43mm FCC ID: 2AZOM-UG2000ID

Internal Photos

Page 1 of 2 Report No.: LGT26H017 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 BLE ANT Page 2 of 2 Report No.: LGT26H017 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: Positioning Device Model Number: UG2000-ID FCC ID: 2AZOM-UG2000ID Issued For : Blueiot (Beijing) Technology Co., Ltd. 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H017HA01 Sample Received Date: Aug. 04, 2026 Date of Test: Aug. 04, 2026 ~ Aug. 19, 2026 Date of Issue: Aug. 19, 2026 Report No.: LGT26H017HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Manufacturer: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Product Name: Positioning Device Trademark: Blueiot Model Number: UG2000-ID Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1091 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Chris Chen Engineer Technical Director Report No.: LGT26H017HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 EUT OPERATION CONDITION 7 2.4 CLASSIFICATION 7 2.5 TEST RESULT 8 Report No.: LGT26H017HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Aug. 19, 2026 Initial Issue Report No.: LGT26H017HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Positioning Device Test Model Number: UG2000-ID Series Number: N/A Model Difference: N/A Frequency Bands: Bluetooth 2402-2480MHz Rating: Input:100-240V~ 50/60Hz 0.6A MAX Output: 12.0V⎓2.0A 24.0W Battery: N/A Hardware Version: V1.0 Software Version: V1.0 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT26H017HA01 Page 6 of 8 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 0.3-3.0 614 1.63 *(100) 3.0-30 1842/f 4.89/f *(900/f 2 ) 30-300 61.4 0.163 1.0 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 1.34-30 824/f 2.19/f *(180/f 2 ) 30-300 27.5 0.073 0.2 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F= Frequency in MHz * = Plane-wave equivalent power density. Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Report No.: LGT26H017HA01 Page 7 of 8 2.3 EUT OPERATION CONDITION EUT was enabled to transmit and receive at lowest, middle and highest channels. 2.4 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. Report No.: LGT26H017HA01 Page 8 of 8 2.5 TEST RESULT Turn up Result Mode Turn up Power BLE 1M-GFSK-2402 1±1dBm BLE 1M-GFSK-2440 2±1dBm BLE 1M-GFSK-2480 1±1dBm BLE 2M-GFSK-2402 1±1dBm BLE 2M-GFSK-2440 2±1dBm BLE 2M-GFSK-2480 1±1dBm The MPE result of worst mode: RF Function Frequency (MHz) Max Turn up Power (dBm) Max Turn up Power (mW) ANT Gain (dBi) ANT Gain (gain of antenna in linear scale) Power Density (mW/cm²) Limit (mW/cm²) Ratio Result BT 2440 3.00 2.00 3 2.00 0.0008 1 0.0008 Pass Note: 1. The Maximum Power Density is less than the limit, complies with the exemption requirements. ※※※※※END OF THE REPORT※※※※※

Test Report

ANTENNA SPECIFICATION 1. Specifications Name ANT_FPC_ BLE_W35H20_V1.0 Size 30x20mm Working Frequency 2.4GHz---2.5GHz Bandwidth 0.1GHz Antenna type FPC antenna VSWR <2 Impendence 50Ω Radiation Properties omnidirectional Polarization type Linear Efficiency (%) 85% Gain 3dBi Working Temperature -40°C~85°C Manufacturer: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China 2. Antenna Characteristic 2.1 Return Loss 2.2 Efficiency 2.3 Radiation pattern Antenna Size Uint: mm

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 55 RF TEST REPORT Product Name: Positioning Device Model Number: UG2000-ID FCC ID: 2AZOM-UG2000ID Issued For : Blueiot (Beijing) Technology Co., Ltd. 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H017RF01 Sample Received Date: Aug. 04, 2026 Date of Test: Aug. 04, 2026 ~ Aug. 19, 2026 Date of Issue: Aug. 19, 2026 Report No.: LGT26H017RF01 Page 2 of 55 TEST REPORT CERTIFICATION Applicant: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Manufacturer: Blueiot (Beijing) Technology Co., Ltd. Address: 10/F, Tower A, TusPark Innovation Plaza, Haidian District, Beijing, China Product Name: Positioning Device Trademark: Blueiot Model Number: UG2000-ID Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT26H017RF01 Page 3 of 55 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 19 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 20 4.6 TEST RESULTS (BAND EDGE REQUIREMENTS) 25 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 26 5.1 LIMIT 26 5.2 TEST PROCEDURE 26 5.3 TEST SETUP 26 5.4 EUT OPERATION CONDITIONS 26 5.5 TEST RESULTS 26 6. POWER SPECTRAL DENSITY TEST 27 6.1 LIMIT 27 6.2 TEST PROCEDURE 27 6.3 TEST SETUP 27 6.4 EUT OPERATION CONDITIONS 27 Report No.: LGT26H017RF01 Page 4 of 55 6.5 TEST RESULTS 27 7. BANDWIDTH TEST 28 7.1 LIMIT 28 7.2 TEST PROCEDURE 28 7.3 TEST SETUP 28 7.4 EUT OPERATION CONDITIONS 28 7.5 TEST RESULTS 28 8. PEAK OUTPUT POWER TEST 29 8.1 LIMIT 29 8.2 TEST PROCEDURE 29 8.3 TEST SETUP 29 8.4 EUT OPERATION CONDITIONS 29 8.5 TEST RESULTS 29 9. ANTENNA REQUIREMENT 30 9.1 STANDARD REQUIREMENT 30 9.2 EUT ANTENNA 30 APPENDIX I - TEST RESULTS 31 DUTY CYCLE 31 MAXIMUM PEAK CONDUCTED OUTPUT POWER 34 -6DB BANDWIDTH 37 OCCUPIED CHANNEL BANDWIDTH 40 MAXIMUM POWER SPECTRAL DENSITY LEVEL 43 BAND EDGE 46 CONDUCTED RF SPURIOUS EMISSION 50 APPENDIX II - MEASUREMENT PHOTOS 55 Report No.: LGT26H017RF01 Page 5 of 55 Revision History Rev. Issue Date Revisions 00 Aug. 19, 2026 Initial Issue Report No.: LGT26H017RF01 Page 6 of 55 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 Part 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024. Report No.: LGT26H017RF01 Page 7 of 55 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB 9 All Emissions, Radiated (18GHz-40GHz) ±4.31dB 10 Temperature ±0.5°C 11 Humidity ±2% 12 Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT26H017RF01 Page 8 of 55 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Positioning Device Test Model Number: UG2000-ID Series Number: N/A Model Difference: N/A Product Description: Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Radio Technology: BLE Bluetooth Configuration: BLE (1M PHY, 2M PHY) Number Of Channel: 40 Antenna Designation: FPC Antenna Gain (dBi) 3 Channel List: Please refer to the Note 3. Adapter: Input:100-240V~ 50/60Hz 0.6A MAX Output: 12.0V⎓2.0A 24.0W Battery: N/A Hardware Version: V1.0 Software Version: V1.0 Connecting I/O Port(s): Please refer to the Note …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.: LGT26H017 Appendix - Test Setup photos Set-up for Radiated Spurious Emission, Below 1GHz Set-up for Radiated Spurious Emission, Above 1GHz Page 2 of 2 Report No.: LGT26H017 Set-up for Conducted Emission

Contact Information

Applicant

Liu jida(Manager)
[email protected]Fax: 15101154880

Technical Contact

HOPEK CORPORATION INCYangyang Xu
[email protected]

16755 Coyote Bush Dr Unit 84, · United States

Test Firm

Shenzhen LGT Test Service Co., Ltd.Wen Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Blueiot (Beijing) Technology Co., Ltd.

BlueIOT RTLS Tag - FCC ID 2AZOM-BT4500-B - Blueiot (Beijing) Technology Co., Ltd.
2AZOM-BT4500-B

BlueIOT RTLS Tag

May 18, 2023

Equipment Class

DTS - Digital Transmission System
Blueiot RTLS Tag - FCC ID 2AZOM-BT1000W - Blueiot (Beijing) Technology Co., Ltd.
2AZOM-BT1000W

Blueiot RTLS Tag

Dec 13, 2022

Equipment Class

DTS - Digital Transmission System
Blueiot RTLS Tag - FCC ID 2AZOM-BT1000G - Blueiot (Beijing) Technology Co., Ltd.
2AZOM-BT1000G

Blueiot RTLS Tag

Apr 26, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Blueiot RTLS Anchor - FCC ID 2AZOM-BA3000T - Blueiot (Beijing) Technology Co., Ltd.
2AZOM-BA3000T

Blueiot RTLS Anchor

Apr 26, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter