Battery capacity: 280mAh Wireless connection: Bluetooth 5.2 Manufacturer: Ultra Easy Health Technology (Guangzhou) Co., LTD
Ultra Easy Health Technology (Guangzhou) Co., LTD 2023.05.06 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for 2BAQM-S8PLUS [Ultra Easy Health Technology (Guangzhou) Co., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) xuyuan chen Ultra Easy Health Technology (Guangzhou) Co., LTD 2023.05.06 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for 2BAQM-S8PLUS [Ultra Easy Health Technology (Guangzhou) Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) xuyuan chen
Ultra Easy Health Technology (Guangzhou) Co., LTD 2023.05.06 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Smart watch Trademark: N/A MODEL : S8 Plus FCC ID : 2BAQM-S8PLUS To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : xuyuan chen /Manager Contact information / address: 228 Huadi Avenue Middle, Liwan District, Guangzhou, China 51000
Ultra Easy Health Technology (Guangzhou) Co., LTD 2023.05.06 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : xuyuan chen /Manager Contact information / address: 228 Huadi Avenue Middle, Liwan District, Guangzhou, China 51000
External Photos
Size:10*5mm Smart watch FCC ID: 2BAQM-S8PLUS Label location
Internal Photos Antenna
RF EXPOSURE EVALUATION METHOD FCC ID: 2BAQM-S8PLUS Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BT Condition Mode Frequency (MHz) Conducted Power (dBm) Limit (dBm) Verdict NVNT 1-DH1 2402 -0.4 21 Pass NVNT 1-DH1 2441 -0.17 21 Pass NVNT 1-DH1 2480 -0.67 21 Pass NVNT 2-DH1 2402 -0.41 21 Pass NVNT 2-DH1 2441 -0.18 21 Pass NVNT 2-DH1 2480 -0.67 21 Pass NVNT 3-DH1 2402 -0.4 21 Pass NVNT 3-DH1 2441 -0.24 21 Pass NVNT 3-DH1 2480 -0.72 21 Pass max possible output power (PK,conducted):0±1dBm -1dBi logarithmic terms convert to numeric result is nearly 0.79 1dBm=1.26mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.402=0.391≤3.0 2441MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.441=0.394≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.48=0.397≤3.0 BLE Frequency Maximum Conducted Output Power(PK) Conducted Output Power Limit (MHz) (dBm) dBm GFSK 1Mbps 2402 -0.13 30 2440 0.16 30 2480 -0.14 30 max possible output power (PK,conducted):0±1dBm -1dBi logarithmic terms convert to numeric result is nearly 0.79 1dBm=1.26mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.402=0.391≤3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.440=0.394≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.48=0.397≤3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.
Model S5 V 1 深圳市和鸣微科技有限公司 PRODUCT SPECIFICATION Test equipment Test system Test environment Active testingPassive testing SG24 GTS temperature:22°C ±3°C humidity:50%±15% BT/WIFI/GPS 600MHZ——6G CMW 500 GTS Agilent 8960 Agilent E5071B SG24 RF Module E2 E3 E1 匹配 ElementValue E1(0201) 2PF E2(0201) 0R E3(0201) Antenna S11 GAIN & Efficiency Frequency (MHz)Gain(dB)Efficiency(%) 2400 -2.6710.66 2410 -2.4110.88 2420 -2.2311.2 2430 -2.1711.24 2440 -1.8511.61 2450 -1.6312.28 2460 -1.3712.69 2470 -1.1313.39 2480 -1.113.87 2490 -114.15 2500 -1.1514.11 2D Radiation Pattern 3D Radiation Pattern Antenna position and size ① length:21mm Diameter0.65mm Add: Floor 1, Building B, Jinghang Industrial Park, Liuxian Second Road, Baoan District 71, Shenzhen City Model S5
No.:BCTC/RF-EMC-007 Page: 1 of 79 Edition:A.5 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2304702885-1E Applicant: Ultra Easy Health Technology (Guangzhou) Co., LTD Product Name: Smart watch Model/Type reference: S8 Plus Tested Date: 2023-04-19 to 2023-04-25 Issued Date: 2023-04-25 Report No.: BCTC2304702885-1E No.:BCTC/RF-EMC-007 Page: 2 of 79 Edition:A.5 FCC ID: 2BAQM-S8PLUS The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Smart watch Trademark: N/A Model/Type Reference: S8 Plus Prepared For: Ultra Easy Health Technology (Guangzhou) Co., LTD Address: 228 Huadi Avenue Middle, Liwan District, Guangzhou, China 51000 Manufacturer: Ultra Easy Health Technology (Guangzhou) Co., LTD Address: 228 Huadi Avenue Middle, Liwan District, Guangzhou, China 51000 Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-04-19 Sample tested Date: 2023-04-19 to 2023-04-25 Issue Date: 2023-04-25 Report No.: BCTC2304702885-1E Test Standards FCC Part15.247 ANSI C63.10-2013 Test Results PASS Remark: This is Bluetooth Classic radio test report. Tested by: Approved by: Lei Chen/Project Handler Zero Zhou/Reviewer Report No.: BCTC2304702885-1E No.:BCTC/RF-EMC-007 Page: 3 of 79 Edition:A.5 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 8 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List .......................................................................................................... 9 4.5 Test Mode ........................................................................................................... 10 4.6 Table Of Parameters Of Text Software Setting ................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test procedure .................................................................................................... 13 6.4 EUT operating Conditions ................................................................................... 13 6.5 Test Result .......................................................................................................... 14 7. Radiated emissions ............................................................................................. 16 7.1 Block Diagram Of Test Setup .............................................................................. 16 7.2 Limit .................................................................................................................... 17 7.3 Test procedure .................................................................................................... 18 7.4 EUT operating Conditions ................................................................................... 19 7.5 Test Result .......................................................................................................... 19 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 23 8.1 Block Diagram Of Test Setup .............................................................................. 23 8.2 Limit .................................................................................................................... 23 8.3 Test procedure .................................................................................................... 24 8.4 EUT operating Conditions ................................................................................... 24 8.5 Test Result .......................................................................................................... 25 9. Spurious RF Conducted Emissions ..................................................................... 26 9.1 Block Diagram Of Test Setup .............................................................................. 26 9.2 Limit .................................................................................................................... 26 9.3 Test procedure .................................................................................................... 26 9.4 Test Result .......................................................................................................... 2…
Text truncated - open the document above for the full version.
Report No.: BCTC2304702885-1E No.:BCTC/RF-EMC-007 Page: 77 of 79 Edition:A.5 17. EUT Test Setup Photographs Conducted Measurement Photo Radiated Measurement Photos Report No.: BCTC2304702885-1E No.:BCTC/RF-EMC-007 Page: 78 of 79 Edition:A.5
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 960.00 µW |

Smart watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
smart watch
Equipment Class
DTS - Digital Transmission System