Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
BIQU×FOXLTInfinityBed Auto-UnloadingHeatedBed InfinityBedP1UserManualV1.0 (Applicableseriesmodel:InfinityBedP2) 1.ProductSpecifications ItemSpecification MaterialMetal/PCB ColorBlack PackageDimensions377.4(L)×332.9(W)×91.4(H)mm PackageWeight3.5kg InputVoltage110-240V~ OperatingPower200-1000W PrintVolume 256 × 256 × 235 MaximumHeatedBed Temperature 110 °C OperatingTemperature 10°C-70°C 2.ModuleDescription 01-PowerSwitch02-StatusLED03-StopButton04-Clean Button FunctionDescription: 01PowerSwitch:movethelevertoONtopoweron,andtoOFFtopoweroff 02StatusLED: Alternatingredandblue:networkpairingmode Solidblue:networkpairingsuccessful,enteringconsolemode Thebuttonlightsredwhenpressed 03StopButton:emergencystopformanualandautomaticplatformcleaning 04CleanButton: Shortpresstostarttheplatformcleaningfunction(pressfornomorethan2seconds) Secondaryfunction:restorefactorysettings.Pressandholdfor10secondstoclearall configurations(theredLEDflasheswhentriggered;theactionstartswhenthebuttonis released) 3.ProductUsageInstructions 3.1DeviceBinding 1.AfterenteringInfinityBedHub,gotothe[SystemSettings-DeviceConfiguration]pageand click[Scan]toscanforprinterdevicesintheenvironment. 2.Oncethescaniscomplete,alldetectedprinterdeviceswillbedisplayedonthepage. 3.Selectthetargetprinterandclick[BindDevice].Entertheprinter'spairingcodeinthedialog boxandclick[Pair]tostartbindingtheprinter. 4.Aftersuccessfulbinding,thestatusandinformationoftheboundprinterwillbedisplayedin [MyPrinters]. 3.2StartingaPrintJob 1.Click[FileManagement].InfinityBedHubwillautomaticallyretrievethefileinformationfrom theprinter'sexternalstorageanddisplayitonthepage. 2.Selectthetargetprintfileandclick[PrintSettings]tocustomizetheparametersofthisprint job. 3.Click[Confirm].Theprintjobwillbeaddedto[DeviceControl-TaskList]andwaittobe printed. 4.Manufacturer Manufacturer:ShenzhenBIQUInnovationTechnologyCo.,Ltd. Address:1508,BuildingT1,LijinchengCenter,YousongCommunity,LonghuaSubdistrict,Longhua District,Shenzhen,Guangdong,China 5.FCCStatements
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID. ........................................... : CTA26082801403 2BAS6-INFINITYBED Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Ace Chai Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Sep. 07, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................. : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Shenzhen BIQU Innovation Technology Co., Ltd. Address ............................................. : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description..................... : BIQU X FOXLT Infinity Bed Trade Mark ....................................... : Manufacturer ..................................... : Shenzhen BIQU Innovation Technology Co., Ltd. Model/Type reference ....................... : BIQU X FOXLT Infinity Bed P1 Listed Models .................................... : BIQU X FOXLT Infinity Bed P2 Rating ............................................... : Input: 110-240V~, 50/60Hz, 200-1000W and 24V1.0A Result ................................................ : PASS Report No.: CTA26082801403 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : BIQU X FOXLT Infinity Bed Model /Type : BIQU X FOXLT Infinity Bed P1 Listed Models : BIQU X FOXLT Infinity Bed P2 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and color are different for these model. So the tests were performed on model BIQU X FOXLT Infinity Bed P1 and the test results for the main test model can cover the listed models. Applicant : Shenzhen BIQU Innovation Technology Co., Ltd. Address : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Manufacturer : Shenzhen BIQU Innovation Technology Co., Ltd. Address : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26082801403 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ................................................................................................................ 4 2 SUMMARY ............................................................................................................................... 5 2.1 General Remarks .......................................................................................................... 5 2.2 Product Description ....................................................................................................... 5 2.3 Special Accessories ...................................................................................................... 5 2.4 Modifications .................................................................................................................. 5 3 TEST ENVIRONMENT ............................................................................................................ 6 3.1 Address of the test laboratory ....................................................................................... 6 3.2 Test Facility.................................................................................................................... 6 3.3 Statement of the measurement uncertainty .................................................................. 6 4 Test limit ................................................................................................................................... 7 4.1 Requirement .................................................................................................................. 7 4.2 MPE Calculation Method ............................................................................................... 7 4.3 Conducted Power Results ............................................................................................. 7 4.4 Manufacturing tolerance .....................................…
Text truncated - open the document above for the full version.
FCCID:2BAS6-INFINITYBED TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2BAS6-INFINITYBED Fig.3 Fig.4
1 FCC Appendix RF Test Data for BLE FCC ID : 2BAS6-INFINITYBED Company : Shenzhen BIQU Innovation Technology Co., Ltd. EUT : BIQU X FOXLT Infinity Bed Model Number : BIQU X FOXLT Infinity Bed P1 Report No. : CTA26082801401 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result Test Mode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.644 2401.688 2402.332 0.5 PASS 2440 0.644 2439.692 2440.336 0.5 PASS 2480 0.640 2479.688 2480.328 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0053 2401.5161 2402.5214 --- --- 2440 1.0130 2439.5141 2440.5271 --- --- 2480 1.0071 2479.5148 2480.5219 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Power[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -3.57 ≤30 PASS 2440 -3.66 ≤30 PASS 2480 -3.84 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result Test Mode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -19.44 ≤8.00 PASS 2440 -19.68 ≤8.00 PASS 2480 -19.68 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result Test Mode Antenna ChName Freq(MHz) RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -3.62 -54.94 ≤-23.62 PASS High 2480 -3.89 -54.78 ≤-23.89 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -4.55 -4.55 --- PASS 30~1000 -4.55 -68.57 ≤-24.55 PASS 1000~26500 -4.55 -47.04 ≤-24.55 PASS 2440 Reference -3.97 -3.97 --- PASS 30~1000 -3.97 -69.1 ≤-23.97 PASS 1000~26500 -3.97 -45.42 ≤-23.97 PASS 2480 Reference -4.78 -4.78 --- PASS 30~1000 -4.78 -69.59 ≤-24.78 PASS 1000~26500 -4.78 -46.07 ≤-24.78 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result Test Mode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result Test Mode Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m ] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -60.93 3.2 1.80 39.27 ≤54 PASS AV 2381.585 -59.14 3.2 1.80 41.06 ≤54 PASS AV 2390.000 -59.45 3.2 1.80 40.75 ≤54 PASS Peak 2310.000 -51.6 3.2 0.00 46.8 ≤74 PASS Peak 2370.455 -49.18 3.2 0.00 49.22 ≤74 PASS Peak 2390.000 -51.07 3.2 0.00 47.33 ≤74 PASS High 2480 AV 2483.500 -58.41 3.2 1.80 41.79 ≤54 PASS AV 2484.240 -58.13 3.2 1.80 42.07 ≤54 PASS AV 2500.000 -59.6 3.2 1.80 40.6 ≤54 PASS Peak 2483.500 -49.09 3.2 0.00 49.31 ≤74 PASS Peak 2484.720 -46.91 3.2 0.00 51.49 ≤74 PASS Peak 2500.000 -51.26 3.2 0.00 47.14 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
34 11N20SISO_Ant1_2412_0~Reference 11N20SISO_Ant1_2412_30~1000 35 11N20SISO_Ant1_2412_1000~26500 11N20SISO_Ant1_2437_0~Reference 11N20SISO_Ant1_2437_30~1000 36 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference 37 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 11N40SISO_Ant1_2422_0~Reference 38 11N40SISO_Ant1_2422_30~1000 11N40SISO_Ant1_2422_1000~26500 39 11N40SISO_Ant1_2437_0~Reference 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 40 11N40SISO_Ant1_2452_0~Reference 11N40SISO_Ant1_2452_30~1000 41 11N40SISO_Ant1_2452_1000~26500 42 Appendix G: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] DC Factor [dB] T Factor [dB] 11B Ant1 2412 8.35 8.39 99.52 0.02 0.12 2437 8.36 8.40 99.52 0.02 0.12 2462 8.35 8.40 99.40 0.03 0.12 11G Ant1 2412 0.15 0.19 78.95 1.03 6.67 2437 0.15 0.20 75.00 1.25 6.67 2462 0.15 0.20 75.00 1.25 6.67 11N20SISO Ant1 2412 0.17 0.22 77.27 1.12 5.56 2437 0.17 0.22 77.27 1.12 5.88 2462 0.17 0.22 77.27 1.12 5.88 11N40SISO Ant1 2422 0.18 0.22 81.82 0.87 5.56 2437 0.18 0.23 78.26 1.06 5.56 2452 0.18 0.23 78.26 1.06 5.56 43 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 44 11G_Ant1_2412 11G_Ant1_2437 45 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 46 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 47 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 48 Appendix H: Emissions in Restricted Bands Test Result Test Mode Antenn a ChNam e Frequen cy[MHz] Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict 11B Ant1 Low 2412 AV 2310.000 -60.35 3.2 0.02 38.07 ≤54 PASS AV 2385.800 -53.44 3.2 0.02 44.98 ≤54 PASS AV 2390.000 -55.69 3.2 0.02 42.73 ≤54 PASS Peak 2310.000 -51.14 3.2 0.00 47.26 ≤74 PASS Peak 2389.570 -46.11 3.2 0.00 52.29 ≤74 PASS Peak 2390.000 -48.5 3.2 0.00 49.9 ≤74 PASS High 2462 AV 2483.500 -55.89 3.2 0.03 42.54 ≤54 PASS AV 2488.070 -54.52 3.2 0.03 43.91 ≤54 PASS AV 2500.000 -59.59 3.2 0.03 38.84 ≤54 PASS Peak 2483.500 -46.77 3.2 0.00 51.63 ≤74 PASS Peak 2488.620 -46.68 3.2 0.00 51.72 ≤74 PASS Peak 2500.000 -50.16 3.2 0.00 48.24 ≤74 PASS 11G Ant1 Low 2412 AV 2310.000 -60.74 3.2 1.03 38.69 ≤54 PASS AV 2386.970 -58.78 3.2 1.03 40.65 ≤54 PASS AV 2390.000 -59.52 3.2 1.03 39.91 ≤54 PASS Peak 2310.000 -52.4 3.2 0.00 46 ≤74 PASS Peak 2386.320 -48.73 3.2 0.00 49.67 ≤74 PASS Peak 2390.000 -52.09 3.2 0.00 46.31 ≤74 PASS High 2462 AV 2483.500 -59.49 3.2 1.25 40.16 ≤54 PASS AV 2484.550 -58.55 3.2 1.25 41.1 ≤54 PASS AV 2500.000 -59.97 3.2 1.25 39.68 ≤54 PASS Peak 2483.500 -51.07 3.2 0.00 47.33 ≤74 PASS Peak 2486.750 -48.71 3.2 0.00 49.69 ≤74 PASS Peak 2500.000 -51.69 3.2 0.00 46.71 ≤74 PASS 11N20SI SO Ant1 Low 2412 AV 2310.000 -60.46 3.2 1.12 39.06 ≤54 PASS AV 2384.760 -58.97 3.2 1.12 40.55 ≤54 PASS AV 2390.000 -59.16 3.2 1.12 40.36 ≤54 PASS Peak 2310.000 -53.02 3.2 0.00 45.38 ≤74 PASS Peak 2388.920 -49.35 3.2 0.00 49.05 ≤74 PASS Peak 2390.000 -50.49 3.2 0.00 47.91 ≤74 PASS High 2462 AV 2483.500 -59.02 3.2 1.12 40.5 ≤54 PASS AV 2484.220 -58.74 3.2 1.12 40.78 ≤54 PASS AV 2500.000 -59.39 3.2 1.12 40.13 ≤54 PASS Peak 2483.500 -50.69 3.2 0.00 47.71 ≤74 PASS 49 Peak 2486.420 -49.07 3.2 0.00 49.33 ≤74 PASS Peak 2500.000 -52.3 3.2 0.00 46.1 ≤74 PASS 11N40SI SO Ant1 Low 2422 AV 2310.000 -60.32 3.2 0.87 38.95 ≤54 PASS AV 2389.850 -57.35 3.2 0.87 41.92 ≤54 PASS AV 2390.000 -57.33 3.2 0.87 41.94 ≤54 PASS Peak 2310.000 -53.39 3.2 0.00 45.01 ≤74 PASS Peak 2387.150 -48 3.2 0.00 50.4 ≤74 PASS Peak 2390.000 -48.85 3.2 0.00 49.55 ≤74 PASS High 2452 AV 2483.500 -59.21 3.2 1.06 40.25 ≤54 PASS AV 2483.875 -58.4 3.2 1.06 41.06 ≤54 PASS AV 2500.000 -58.93 3.2 1.06 40.53 ≤54 PASS Peak 2483.500 -50.67 3.2 0.00 47.73 ≤74 PASS Peak 2496.250 -48.59 3.2 0.00 49.81 ≤74 PASS Peak 2500.000 -51.61 3.2 0.00 46.79 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 50 Test Graphs 11B_Ant1_Low_2412_AV 11B_Ant1_Low_2412_Peak 11B_Ant1_High_2462_AV 51 11B_Ant1_High_2462_Peak 11G_Ant1_Low_2412_AV 52 11G_Ant1_Low_2412_Peak 11G_Ant1_High_2462_AV 11G_Ant1_High_2462_Peak 53 11N20SISO_Ant1_Low_2412_AV 11N20SISO_Ant1_Low_2412_Peak 54 11N20SISO_Ant1_High_2462_AV 11N20SISO_Ant1_High_2462_Peak 11N40SISO_Ant1_Low_2422_AV 55 11N40SISO_Ant1_Low_2422_Peak 11N40SISO_Ant1_High_2452_AV 56 11N40SISO_Ant1_High_2452_Peak
1 FCC Appendix RF Test Data for 2.4GWIFI FCC ID : 2BAS6-INFINITYBED Company : Shenzhen BIQU Innovation Technology Co., Ltd. EUT : BIQU X FOXLT Infinity Bed Model Number : BIQU X FOXLT Infinity Bed P1 Report No. : CTA26082801402 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result Test Mode Antenna Frequency[MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 10.200 2406.920 2417.120 0.5 PASS 2437 10.240 2431.920 2442.160 0.5 PASS 2462 10.240 2456.920 2467.160 0.5 PASS 11G Ant1 2412 15.640 2404.200 2419.840 0.5 PASS 2437 15.760 2429.120 2444.880 0.5 PASS 2462 15.520 2454.440 2469.960 0.5 PASS 11N20SISO Ant1 2412 16.320 2403.760 2420.080 0.5 PASS 2437 17.040 2428.480 2445.520 0.5 PASS 2462 16.280 2453.480 2469.760 0.5 PASS 11N40SISO Ant1 2422 35.680 2404.480 2440.160 0.5 PASS 2437 35.040 2419.800 2454.840 0.5 PASS 2452 35.920 2434.160 2470.080 0.5 PASS 3 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 4 11G_Ant1_2412 11G_Ant1_2437 5 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 6 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 7 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 8 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Channel Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 13.410 2405.3068 2418.7168 --- --- 2437 13.415 2430.3077 2443.7227 --- --- 2462 13.416 2455.3201 2468.7361 --- --- 11G Ant1 2412 16.843 2403.6001 2420.4431 --- --- 2437 16.864 2428.6048 2445.4688 --- --- 2462 16.788 2453.6256 2470.4136 --- --- 11N20SISO Ant1 2412 17.887 2403.0781 2420.9651 --- --- 2437 17.868 2428.0713 2445.9393 --- --- 2462 17.913 2453.0572 2470.9702 --- --- 11N40SISO Ant1 2422 36.092 2404.1048 2440.1968 --- --- 2437 36.059 2419.1389 2455.1979 --- --- 2452 36.092 2434.1255 2470.2175 --- --- 9 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 10 11G_Ant1_2412 11G_Ant1_2437 11 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 12 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 13 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 14 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Frequency[MHz] Peak power [dBm] Limit [dBm] Verdict 11B Ant1 2412 13.09 ≤30.00 PASS 2437 13.25 ≤30.00 PASS 2462 13.36 ≤30.00 PASS 11G Ant1 2412 12.58 ≤30.00 PASS 2437 12.81 ≤30.00 PASS 2462 13.06 ≤30.00 PASS 11N20SISO Ant1 2412 12.44 ≤30.00 PASS 2437 12.73 ≤30.00 PASS 2462 12.84 ≤30.00 PASS 11N40SISO Ant1 2422 12.96 ≤30.00 PASS 2437 13.16 ≤30.00 PASS 2452 13.09 ≤30.00 PASS 15 Appendix D: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict 11B Ant1 2412 -13.17 ≤8.00 PASS 2437 -12.88 ≤8.00 PASS 2462 -12.28 ≤8.00 PASS 11G Ant1 2412 -17.96 ≤8.00 PASS 2437 -18.67 ≤8.00 PASS 2462 -18.93 ≤8.00 PASS 11N20SISO Ant1 2412 -19.26 ≤8.00 PASS 2437 -18.52 ≤8.00 PASS 2462 -19.15 ≤8.00 PASS 11N40SISO Ant1 2422 -21.83 ≤8.00 PASS 2437 -19.60 ≤8.00 PASS 2452 -21.41 ≤8.00 PASS 16 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 17 11G_Ant1_2412 11G_Ant1_2437 18 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 19 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 20 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 21 Appendix E: Band edge measurements Test Result Test Mode Antenna ChName Frequency[MHz] RefLevel[dBm] Result[dBm] Limit[dBm] Verdict 11B Ant1 Low 2412 0.55 -47.54 ≤-19.45 PASS High 2462 1.45 -53.39 ≤-18.55 PASS 11G Ant1 Low 2412 -3.78 -35.54 ≤-23.78 PASS High 2462 -3.42 -57.78 ≤-23.42 PASS 11N20SISO Ant1 Low 2412 -3.75 -35.33 ≤-23.75 PASS High 2462 -3.59 -57.28 ≤-23.59 PASS 11N40SISO Ant1 Low 2422 -6.97 -35.4 ≤-26.97 PASS High 2452 -7.07 -57.42 ≤-27.07 PASS 22 Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 23 11G_Ant1_High_2462 11N20SISO_Ant1_Low_2412 24 11N20SISO_Ant1_High_2462 11N40SISO_Ant1_Low_2422 11N40SISO_Ant1_High_2452 25 26 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Frequency[MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 0.36 0.36 --- PASS 30~1000 0.36 -67.79 ≤-19.64 PASS 1000~26500 0.36 -46.58 ≤-19.64 PASS 2437 Reference 0.75 0.75 --- PASS 30~1000 0.75 -69.06 ≤-19.25 PASS 1000~26500 0.75 -46.36 ≤-19.25 PASS 2462 Reference 0.47 0.47 --- PASS 30~1000 0.47 -68.34 ≤-19.53 PASS 1000~26500 0.47 -46.78 ≤-19.53 PASS 11G Ant1 2412 Reference -4.49 -4.49 --- PASS 30~1000 -4.49 -68.98 ≤-24.49 PASS 1000~26500 -4.49 -46.91 ≤-24.49 PASS 2437 Reference -3.60 -3.60 --- PASS 30~1000 -3.60 -68.95 ≤-23.6 PASS 1000~26500 -3.60 -46.35 ≤-23.6 PASS 2462 Reference -4.36 -4.36 --- PASS 30~1000 -4.36 -68.54 ≤-24.36 PASS 1000~26500 -4.36 -45.78 ≤-24.36 PASS 11N20SISO Ant1 2412 Reference -4.39 -4.39 --- PASS 30~1000 -4.39 -68.75 ≤-24.39 PASS 1000~26500 -4.39 -46.68 ≤-24.39 PASS 2437 Reference -4.30 -4.30 --- PASS 30~1000 -4.30 -68.58 ≤-24.3 PASS 1000~26500 -4.30 -46.4 ≤-24.3 PASS 2462 Reference -3.72 -3.72 --- PASS 30~1000 -3.72 -65.52 ≤-23.72 PASS 1000~26500 -3.72 -46.48 ≤-23.72 PASS 11N40SISO Ant1 2422 Reference -7.72 -7.72 --- PASS 30~1000 -7.72 -68.35 ≤-27.72 PASS 1000~26500 -7.72 -46.6 ≤-27.72 PASS 2437 Reference -7.15 -7.15 --- PASS 30~1000 -7.15 -68.64 ≤-27.15 PASS 1000~26500 -7.15 -46.42 ≤-27.15 PASS 2452 Reference -6.82 -6.82 --- PASS 30~1000 -6.82 -68.77 ≤-26.82 PASS 1000~26500 -6.82 -46.83 ≤-26.82 PASS 27 Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 28 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 29 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 30 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference 31 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference 32 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 33 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. .......................................... : CTA26082801402 2BAS6-INFINITYBED Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Sep. 07, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Shenzhen BIQU Innovation Technology Co., Ltd. Address ............................................ : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Test specification.......................... : Standard .......................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : BIQU X FOXLT Infinity Bed Trade Mark ....................................... : Manufacturer .................................... : Shenzhen BIQU Innovation Technology Co., Ltd. Model/Type reference ...................... : BIQU X FOXLT Infinity Bed P1 Listed Models ................................... : BIQU X FOXLT Infinity Bed P2 Modulation Type .............................. : CCK/DSSS/OFDM Operation Frequency ....................... : From 2412 - 2462MHz Rating ............................................... : Input: 110-240V~, 50/60Hz, 200-1000W and 24V1.0A Result ............................................... : PASS Report No.: CTA26082801402 Page 2 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : BIQU X FOXLT Infinity Bed Model /Type : BIQU X FOXLT Infinity Bed P1 Listed Models : BIQU X FOXLT Infinity Bed P2 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and color are different for these model. So the tests were performed on model BIQU X FOXLT Infinity Bed P1 and the test results for the main test model can cover the listed models. Applicant : Shenzhen BIQU Innovation Technology Co., Ltd. Address : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Manufacturer : Shenzhen BIQU Innovation Technology Co., Ltd. Address : 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26082801402 Page 3 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS .......................................................................................................................................... 4 2 SUMMARY ........................................................................................................................................................ 5 2.1 General Remarks .................................................................................................................................... 5 2.2 Product Description ................................................................................................................................. 5 2.3 Equipment Under Test ............................................................................................................................ 5 2.4 Short description of the Equipment under Test (EUT) ............................................................................ 5 2.5 EUT configuration .................................................................................................................................... 5 2.6 EUT operation mode ............................................................................................................................... 6 2.7 Block Diagram of Test Setup .................................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) .............................................................................................................. 6 2.9 Modifications ........................................................................................................................................... 6 3 TEST ENVIRONMENT ............................................…
Text truncated - open the document above for the full version.
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ........................................ : CTA26082801401 2BAS6-INFINITYBED Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Sep. 07, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ...........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Shenzhen BIQU Innovation Technology Co., Ltd. Address ...........................................: 1508, Building T1, Lijincheng Center Yousong Community, Longhua Subdistrict, Longhua District, Shenzhen Guangdong Province, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulti…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 21.70 mW |

Filament Dryer
Equipment Class
DTS - Digital Transmission System
Panda Bamboo Feeder
Equipment Class
DTS - Digital Transmission System
Panda PWR
Equipment Class
DTS - Digital Transmission System
BIQU Panda Treat
Equipment Class
DTS - Digital Transmission System
Panda Knomi
Equipment Class
DTS - Digital Transmission System