Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2) CONTROL PANEL INTRODUCTION 67 12345 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Cet équipement respecte les limites d'exposition aux radiations fixées par la FCC pour un environnement non contrôlé. Il doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Rev1/26/2023 ShenzhenYuanRuiInformationTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026/5/18 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BCBU-HZB-12 ShenzhenYuanRuiInformationTechnologyCo.,Ltd(“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. ShenzhenLianshunIntelligentCo.,Ltd(“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedby KasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwithintegratedKaspersky Lab,Inc.(oranyofitssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24- 886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, LucyLiu Rev1/26/2023 ShenzhenYuanRuiInformationTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026/5/18 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BCBU-HZB-12 ShenzhenYuanRuiInformationTechnologyCo.,Ltd(“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentity oranyofitssubsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, LucyLiu
Rev11/20/07 ShenzhenYuanRuiInformationTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision Date:2026/5/ ConfidentialityRequestregardingapplicationforcertificationofFCCID:2BCBU-HZB-12 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName* BlockDiagram,Schematics,Operation Description BlockDiagram.pdf, Schematics.pdf OperationDescription.pdf Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. Werequestthefollowingattachmentstobekeptconfidentialforashortperiodoftimewithin 180daysfromthedateofsubmittingtheFCCID. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName* TestSetupPhotosTestSetupPhotos.pdf internalphotographsinternalphotographs.pdf Sincerely, LucyLiu ShenzhenYuanRuiInformationTechnologyCo.,Ltd
M:\MasterDocuments\TEMPLATES\POA_Letter.doc ShenzhenYuanRuiInformationTechnologyCo.,Ltd Room201,ABldg,NO.1QianWan1stRoadShenZhenHongKongCooperationZone Date:2026/5/18 SUBJECT:FCCID:2BCBU-HZB-12 ToWhomItMayConcern: We,theundersigned,herebyauthorizeDongguanDNTestingCo.,Ltdonourbehalf,to applytotheFederalCommunicationsCommission.AnyandallactscarriedoutbyApple Leeonourbehalfshallhavethesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, LucyLiu ShenzhenYuanRuiInformationTechnologyCo.,Ltd
ShenzhenYuanRuiInformationTechnologyCo.,Ltd Room201,ABldg,NO.1QianWan1stRoadShenZhenHongKongCooperationZone Date:2026/5/18 SUBJECT:FCCID:2BCBU-HZB-12 ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, ShenzhenYuanRuiInformationTechnologyCo.,Ltd LucyLiu
DNT2604141488R02820-P01Page: 1 of 3 PHOTOGRAPHSOFEUT FCCID:2BCBU-HZB-12 ExternalPhotos ExternalPhotos DNT2604141488R02820-P01Page: 2 of 3 ExternalPhotos ExternalPhotos DNT2604141488R02820-P01Page: 3 of 3 ExternalPhotos ExternalPhotos --END--
SmartlceMaker FCCID:2BCBU-HZB-12 Thisdevicecomplieswithpart15oftheFCCrules. Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseharmful interference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterference thatmaycauseundesiredoperation.
GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] RFExposureEvaluationReport ApplicationNo.: DNT2604141488R02820-04606 Applicant: ShenzhenYuanRuiInformationTechnologyCo.,Ltd AddressofApplicant: Room201,ABldg,NO.1QianWan1stRoadShenZhenHongKong CooperationZoneShenzhenChina EUTDescription: SmartIceMaker ModelNo.: HZB-12/H-W AdditionalModel(s): / FCCID: 2BCBU-HZB-12 Powersupply AC120V/60Hz TradeMark: Crownful Standards: 47CFRPart2.1091 FCCKDB447498D01v06 DateofReceipt: 2026/04/14 DateofTest: 2026/04/15to2026/05/07 DateofIssue: 2026/05/14 TestResult: PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:Ifthereisanyobjectiontotheresultsinthisreport,pleasesubmitawritteninquirytothecompanywithin15daysfromthedateof receivingthereport.Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,andisissuedbythecompanyinaccordance withtherequirementsofthe"ConditionsofIssuanceofTestReports"printedintheattachedpage.Unlessotherwisestated,theresults presentedinthisreportonlyapplytothesamplestestedthistime.Partialreproductionofthisreportisnotallowedunlessapprovedbythe companyinwriting. ReportNo.:DNT2604141488R02820-04606Date:May14,2026Page: 2 / 7 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/May14,2026ValidOriginalReport ReportNo.:DNT2604141488R02820-04606Date:May14,2026Page: 3 / 7 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Contents 1GENERALINFORMATION............................................................................................................................................................4 1.1TESTLOCATION..........................................................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT..............................................................................................................................................4 1.3TESTFACILITY............................................................................................................................................................................5 2RFEXPOSUREEVALUATION.....................................................................................................................................................6 2.1RFEXPOSURECOMPLIANCEREQUIREMENT............................................................................................................................6 2.1.1Limits..................................................................................................................................................................................6 2.1.2TestProcedure.................................................................................................................................................................7 2.1.3EUTRFExposureEvaluation........................................................................................................................................7 ReportNo.:DNT2604141488R02820-04606Date:May14,2026Page: 4 / 7 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1GeneralInformation 1.1TestLocation Company:GuangdongDNTestingCo.,Ltd Address: No.1,WestFourthStreet,SouthXinfaRoad,WushaLiwu,Chang’anTown, DongguanCity,GuangdongP.R.China Testengineer:GaliLin 1.2GeneralDescriptionofEUT Manufacturer: ShenzhenFarayInfoTechCo.,Ltd AddressofManufacturer: Room401,BlockA,XichuangTechnologyBuilding,No.7025,LiuxianAvenue, XiliCommunity,XiliStreet,NanshanDistrict,ShenzhenChina Factory: NingboHiconIndustryTechnologyCo.,Ltd. AddressofFactory: No.55,4thBinhaiRoad,QianwanNewArea,Ningbo,Zhejiang,P.R.China, 315324 EUTDescription: SmartIceMaker ModelNo.: HZB-12/H-W AdditionalModel(s): / PowerSupply: AC120V/60Hz TradeMark: Crownful HardwareVersion: V1.0 SoftwareVersion: V1.0 ChipType: ESP32-C3 Serialnumber PR2604141488R02820 SampleType:PortableDevice,Module,MobileDevice AntennaType: External,Integrated AntennaPorts: Ant1,Ant2,Ant3 AntennaGain: Providedbyapplicant 4.16dBi Note: *Sincetheabovedataand/orinformationisprovidedbytheclientrelevantresultsorconclusionsofthis reportareonlymadeforthesedataand/orinformation,DNTisnotresponsiblefortheauthenticity,integrity andresultsofthedataandinformationand/orthevalidityoftheconclusion. ReportNo.:DNT2604141488R02820-04606Date:May14,2026Page: 5 / 7 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1.3TestFacility Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: LabA: •FCC,USA DesignationNumber:CN1348 •A2LA(CertificateNo.7050.01) GUANGDONGDNTESTINGCO.,LTD.isaccreditedbytheAmericanAssociationforLaboratory Accreditation(A2LA).CertificateNo.7050.01. •Innovation,ScienceandEconomicDevelopmentCanada GUANGDONGDNTESTINGCO.,LTD.EMCLaboratoryhasbeenrecognizedbyISEDasanaccreditedtesting laboratory.CABidentifierisCN0149. IC#:30755. ReportNo.:DNT2604141488R02820-04606Date:May14,2026Page: 6 / 7 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 2RFExposureEvaluation 2.1RFExposureComplianceRequirement 2.1.1Limits Frequ…
Text truncated - open the document above for the full version.
Size
GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] FCCTestReport ApplicationNo.: DNT2604141488R02820-04608 Applicant: ShenzhenYuanRuiInformationTechnologyCo.,Ltd AddressofApplicant: Room201,ABldg,NO.1QianWan1stRoadShenZhenHongKong CooperationZoneShenzhenChina EUTDescription: SmartIceMaker ModelNo.: HZB-12/H-W AdditionalModel(s): / FCCID: 2BCBU-HZB-12 PowerSupply: AC120V/60Hz TradeMark: Crownful Standards: 47CFRPart2,SubpartJ 47CFRPart15,SubpartC ANSIC63.10:2020 DateofReceipt: 2026/04/14 DateofTest: 2026/04/15to2026/05/07 DateofIssue: 2026/05/14 TestResult:PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:Ifthereisanyobjectiontotheresultsinthisreport,pleasesubmitawritteninquirytothecompanywithin15daysfromthedateof receivingthereport.Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,andisissuedbythecompanyinaccordance withtherequirementsofthe"ConditionsofIssuanceofTestReports"printedintheattachedpage.Unlessotherwisestated,theresults presentedinthisreportonlyapplytothesamplestestedthistime.Partialreproductionofthisreportisnotallowedunlessapprovedbythe companyinwriting. ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 2 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/May14,2026ValidOriginalReport ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 3 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1TestSummary TestItemTestRequirementTestMethodTestResultResult AntennaRequirement 15.203/247(b)--Clause3.1PASS DutyCycle----Clause3.2PASS DTS(6dB)Bandwidth15.247(a)(2)ANSIC63.10:2020Clause3.3PASS ConductedOutputPower15.247(b)(3)ANSIC63.10:2020Clause3.4PASS PowerSpectralDensity15.247(e)ANSIC63.10:2020Clause3.5PASS Band-edgeforRF ConductedEmissions 15.247(d)ANSIC63.10:2020Clause3.6PASS RFConductedSpurious Emissions 15.247(d)ANSIC63.10:2020Clause3.7PASS RadiatedSpuriousEmissions15.247(d);15.205/15.209ANSIC63.10:2020Clause3.8PASS Restrictedbandsaround fundamentalfrequency(Radiated Emission) 15.247(d);15.205/15.209ANSIC63.10:2020Clause3.9PASS ACPowerLine ConductedEmission 15.207ANSIC63.10:2020Clause3.10PASS Note: 1.“N/A”denotestestisnotapplicableinthistestreport. ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 4 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Contents 1TestSummary..................................................................................................................................................................3 2GeneralInformation..........................................................................................................................................................5 2.1TestLocation..........................................................................................................................................................5 2.2GeneralDescriptionofEUT...................................................................................................................................6 2.3ChannelList...........................................................................................................................................................7 2.4TestEnvironmentandMode..................................................................................................................................7 2.5PowerSettingofTestSoftware.............................................................................................................................7 2.6DescriptionofSupportUnits..................................................................................................................................7 2.7TestFacility............................................................................................................................................................8 2.8MeasurementUncertainty(95%confidencelevels,k=2)......................................................................................8 2.9EquipmentList.......................................................................................................................................................9 2.10Assistantequipmentusedfortest......................................................................................................................10 3TestresultsandMeasurementData..............................................................................................................................11 3.1AntennaRequirement..........................................................................................................................................11 3.2DutyCycle............................................................................................................................................................12 3.3DTS(6dB)Bandwidth.........................................................................................................................................13 3.4Maximumconducted(average)outputpower.....................................................................................................14 3.5PowerSpectralDensity........................................................................................................................................15 3.6Band-edgeforRFConductedEmissions....................................................................................…
Text truncated - open the document above for the full version.
ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:21/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Testdata For30-1000MHz Horizontal: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 154.0624.00-8.2115.7940.0024.2110068PKH 2119.4531.44-10.3221.1243.5022.38100320PKH 3181.7433.14-9.5523.5943.5019.9110068PKH 4196.8735.96-11.0224.9443.5018.5610040PKH 5531.9824.78-1.1723.6146.0022.3910054PKH 6786.7528.624.0432.6646.0013.34100134PKH Vertical: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] RemarkPolarity 130.7823.80-9.9113.8940.0026.11100322PKV 2121.0040.48-10.1930.2943.5013.21100360PKV 3132.6538.15-9.1828.9743.5014.531003PKV 4169.9032.56-8.2924.2743.5019.23100190PKV 5185.4333.99-10.0323.9643.5019.54100204PKV 6786.5628.264.0432.3046.0013.7010056PKV ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:22/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Forabove1GHz 11B2412MHz Horizontal: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 1 4824.0060.15-4.6355.5274.0018.48150356PKH 2 7236.0046.43-1.7044.7374.0029.27150212PKH 3 9648.0042.231.0743.3074.0030.70150238PKH 4 4824.0050.96-4.6346.3354.007.6715010AVH 5 7236.0040.45-1.7038.7554.0015.25150212AVH 6 9648.0035.341.0736.4154.0017.59150134AVH Vertical: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 14824.0059.27-4.6354.6474.0019.36150104PKV 27236.0043.70-1.7042.0074.0032.0015051PKV 39648.0043.491.0744.5674.0029.44150287PKV 44824.0049.68-4.6345.0554.008.95150178AVV 57236.0036.76-1.7035.0654.0018.94150262AVV 69648.0037.131.0738.2054.0015.80150312AVV ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:23/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 11B2437MHz Horizontal: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 14874.0060.61-4.7055.9174.0018.09150338PKH 27311.0042.83-1.5341.3074.0032.70150162PKH 39748.0043.261.5644.8274.0029.18150239PKH 44874.0055.56-4.7050.8654.003.14150338AVH 57311.0035.16-1.5333.6354.0020.37150189AVH 69748.0033.521.5635.0854.0018.9215012AVH Vertical: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 14874.0061.52-4.7056.8274.0017.18150233PKV 27311.0043.42-1.5341.8974.0032.11150285PKV 39748.0043.851.5645.4174.0028.59150207PKV 44874.0055.37-4.7050.6754.003.33150233AVV 57311.0035.57-1.5334.0454.0019.96150311AVV 69748.0034.701.5636.2654.0017.74150233AVV ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:24/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 11B2462MHz Horizontal: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 14923.8556.70-4.7951.9174.0022.09150136PKH 27386.0042.98-1.3241.6674.0032.34150187PKH 39848.0041.572.0043.5774.0030.43150111PKH 44924.0054.49-4.7949.7054.004.30150160AVH 57386.0035.03-1.3233.7154.0020.29150211AVH 69848.0035.122.0037.1254.0016.88150136AVH Vertical: NO. Freq. [MHz] Reading Level [dBμV] Correct Factor [dB/m] Result Level [dBμV/m] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Remark Polarity 14924.0061.29-4.7956.5074.0017.50150287PKV 27386.0043.92-1.3242.6074.0031.40150185PKV 39848.0041.622.0043.6274.0030.38150262PKV 44924.0054.14-4.7949.3554.004.65150287AVV 57386.0034.93-1.3233.6154.0020.39150287AVV 69848.0034.882.0036.8854.0017.12150235AVV ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:25/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Note: 1.TheMeasurement(ResultLevel)iscalculatedbyReadingLeveladdingtheCorrectFactor(maybe includingAnt.FactorandtheCableFactoretc.),Thebasicequationisasfollows: ResultLevel=ReadingLevel+CorrectFactor(includingAnt.Factor,CableFactoretc.) 2.Theamplitudeof9KHzto30MHzspuriousemissionthatisattenuatedbymorethan20dBbelowthe permissiblelimithasnoneedtobereported. 3.Theamplitudeof18GHzto25GHzspuriousemissionthatisattenuatedbymorethan20dBbelowthe permissiblelimithasnoneedtobereport. 4.Allchannelshadbeenpre-test,onlytheworstcasewasreported. ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:26/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 3.9Restrictedbandsaroundfundamentalfrequency TestRequirement:47CFRPart15CSection15.209and15.205 TestMethod:ANSIC63.10:2020Section11.12 TestSite:MeasurementDistance:3mor10m(Semi-AnechoicChamber) Limit:FrequencyLimit(dBuV/m)Remark 30MHz-88MHz40.0Quasi-peak 88MHz-216MHz43.5Quasi-peak 216MHz-960MHz46.0Quasi-peak 960MHz-1GHz54.0Quasi-peak Above1GHz 54.0AverageValue 74.0PeakValue TestSetup: Figure1.30MHzto1GHzFigure2.Above1GHz ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:27/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet…
Text truncated - open the document above for the full version.
ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page:33/67 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] NeutralLine: NO. Freq. [MHz] Factor [dB] QP Value [dBμV] QP Limit [dBμV] QP Margin [dB] AV Value [dBμV] AV Limit [dBμV] AV Margin [dB] Verdict 10.15409.8060.8865.784.9043.9255.7811.86PASS 20.18579.8455.6364.238.6039.2254.2315.01PASS 30.29849.8842.9560.2917.3426.5850.2923.71PASS 40.60279.7932.3556.0023.6525.9546.0020.05PASS 52.84619.8626.0156.0029.997.3246.0038.68PASS 614.82579.9311.4760.0048.534.7150.0045.29PASS Remark: 1.ThefollowingQuasi-PeakandAveragemeasurementswereperformedontheEUT: 2.TheMeasurement(ResultLevel)iscalculatedbyReadingLeveladdingtheCorrectFactor(maybe includingLISNFactorandtheCableFactoretc.),Thebasicequationisasfollows: ResultLevel=ReadingLevel+CorrectFactor(includingLISNFactor,CableFactoretc.) ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 34 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 4Appendix AppendixA:DutyCycle TestResult TestModeAntennaFrequency[MHz] Transmission Duration[ms] Transmission Period[ms] DutyCycle [%] Factor 11BAnt124121.011.1190.990.41 11BAnt124371.011.1190.990.41 11BAnt124621.001.1190.090.45 11GAnt124120.620.6792.540.34 11GAnt124370.620.6792.540.34 11GAnt124620.610.6791.040.41 11N20SISOAnt124120.610.6791.040.41 11N20SISOAnt124370.610.6692.420.34 11N20SISOAnt124620.610.6692.420.34 11N40SISOAnt124220.320.3786.490.63 11N40SISOAnt124370.320.3786.490.63 11N40SISOAnt124520.320.3786.490.63 ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 35 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] TestGraphs NTNV-11B-Ant1-2412 NTNV-11B-Ant1-2437 NTNV-11B-Ant1-2462 ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 36 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] NTNV-11G-Ant1-2412 NTNV-11G-Ant1-2437 NTNV-11G-Ant1-2462 ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 37 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] NTNV-11N20SISO-Ant1-2412 NTNV-11N20SISO-Ant1-2437 NTNV-11N20SISO-Ant1-2462 ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 38 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] NTNV-11N40SISO-Ant1-2422 NTNV-11N40SISO-Ant1-2437 NTNV-11N40SISO-Ant1-2452 ReportNo.:DNT2604141488R02820-04608Date:May14,2026Page: 39 / 67 Guangdong DNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] AppendixB:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1241210.0402406.9602417.0000.5PASS 11BAnt124379.0802432.4402441.5200.5PASS 11BAnt124629.4802457.5202467.0000.5PASS 11GAnt1241216.3602403.8402420.2000.5PASS 11GAnt1243716.3602428.8802445.2400.5PASS 11GAnt1246216.3602453.8802470.2400.5PASS 11N20SISOAnt1241217.4002403.3602420.7600.5PASS 11N20SISOAnt1243717.5202428.2802445.8000.5PASS 11N20SISOAnt1246217.4402453.3602470.8000.5…
Text truncated - open the document above for the full version.
19 GEORGETOWN, · Irvine, California, 92612 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 87.49 mW |

Smart Wireless Meat Thermometer
Equipment Class
DTS - Digital Transmission System
Al Nutriscale Aquseal
Equipment Class
DTS - Digital Transmission System
Reaction Training System
Equipment Class
DTS - Digital Transmission System
Eye Massager
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Humidifier
Equipment Class
DTS - Digital Transmission System