Version˖ 0 Software Operation Instruction 4.4 Other Functions Lock/Unlock ControlPress the unlock or lock button in FOB ༃ battery level is normal, [Signal Sending Prompt] ༄ battery level is low, [Low Power Prompt] ༅ Press and hold the button to send the signal continuously; release the button to stop. The maximum sending duration is 10 seconds 4.3 Low Power Detection Perform battery level detection after pressing any button. Low power is defined when the battery voltage drops to 2.4±0.1V; it is recommended to replace the battery as soon as possible. 4.2 The Functions Of FOB a. This FOB is equipped with 2 groups of control buttons (each group includes one unlock button and one lock button, total 4 buttons). b. Each group of buttons can be separately bound to multiple devices to achieve grouped synchronous control. c. When the user operates a specific group of buttons, all devices bound to this group (devices within the control range) will respond simultaneously and execute the unlock or lock command. Note: Pressing the buttons again during signal transmission will not interrupt the signal sending process. FunctionInstructionDescription Signal Sending Prompt White light flashes continuously /Flashing stops when sending ends Low Power Prompt Red light flashes continuously /Flashing stops when sending ends 4. Instruction 4.1 Sound & Light Indicator Prompt ItemLight StatusBuzzer StatusOthers 第1页 E.60036.01.101.00 1. Description: the FOB equips with 433.92 MHz, 4 buttons and 1 coin battery, which is used to match the RV lock. After matched, the FOB could be used to lock/unlock the RV lock 2. Program˖71.25.023.01 3. Parameters Working Voltage DC3.0V˄CR2032 coin battery˅ Quiescent Current 1uA ( standby mode, which means the control signal transmission stops (the indicator light ceases to flash) and no button is pressed.) Dynamic Current 20mA (in standby mode, press and release any button until the device returns to standby mode.) Low Power Indicator Yes ᵪᇶ᮷Ԧ Version˖ 0 Software Operation Instruction 第2页 E.60036.01.101.00 ᵪᇶ᮷Ԧ Mark Old Version New Version Draft/Date˖ ằ㜌 2025.12.12 Audit/Date˖ 䬻ݶ䜁 2025.12.12 Approved/Date˖ 䖹ݹṮ 2025.12.12 Before ChangeAfter ChangeDate FunctionOperationPhenomenon Software Version Display Press and hold the lock buttons (from both button groups) simultaneously for 5 seconds or longer If the operation is correct: the red and white lights turn on at the same time, then flash. The number of white light flashes indicates the main version number; the number of red light flashes indicates the secondary version number. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modi¿cations to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The device can be used in portable exposure condition without restriction.
Page1of4FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.3 Fig.4 Page3of4FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.5 Fig.6 Page4of4FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.7
Page1of1FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com LABELANDLOCATION Material:tagboard Glue:adhesivesticker Frontcolor:black Labelcolor:Mattsilver (Size:L2.0cmxW1.0cm) LabelLocation KeyFOB Model:KeyFOB FCCID:2BDX6-R015V
Page 1 of 3 FCC ID: 2BDX6-R015V Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2BDX6-R015V Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 3 Fig. 4 Antenna Page 3 of 3 FCC ID: 2BDX6-R015V Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 5 Fig. 6
Page1of9FCCID:2BDX6-R015VReportNo.:LCSC12225022EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation For RVLOCK&CO,LLC KeyFOB TestModel:KeyFOB Preparedfor:RVLOCK&CO,LLC Address:1770WEST2690SOUTHWELLSVILLE,UT84339 Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:December22,2025 Numberoftestedsamples:2 SampleNo.:C251222017-1,C251222017-2 Serialnumber:Prototype DateofTest:December22,2025~January12,2026 DateofReport:January13,2026 Page2of9FCCID:2BDX6-R015VReportNo.:LCSC12225022EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation ReportReferenceNo. .................. :LCSC12225022EB DateofIssue .................................... :January13,2026 TestingLaboratoryName...........:GuangzhouLCSComplianceTestingLaboratoryLtd. Address.............................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure......... :FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName..........................:RVLOCK&CO,LLC Address.............................................:1770WEST2690SOUTHWELLSVILLE,UT84339 TestSpecification Standard...........................................: FCCKDBpublication447498D01General1RFExposureGuidance v06 FCCCFR47part11.1310 FCCCFR47part22.1093 TestReportFormNo...................:TRF-4-E-215A/0 TRFOriginator.................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF......................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription. ................. :KeyFOB TradeMark ....................................... : N/A TestModel ....................................... : KeyFOB Ratings .............................................. :PleaseRefertoPage6 Result ................................................ :PASS Compiledby:Supervisedby:Approvedby: AceYao/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of9FCCID:2BDX6-R015VReportNo.:LCSC12225022EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC12225022EB January13,2026 Dateofissue TestMode...........................:KeyFOB EUT....................................:KeyFOB Applicant...........................:RVLOCK&CO,LLC Address..............................:1770WEST2690SOUTHWELLSVILLE,UT84339 Telephone..........................:/ Fax.....................................:/ Manufacturer..................:XIAMENMAKESECURITYTECHNOLOGYCO.,LTD Address..............................:NO.29,HOUSHANTOUROAD,SHENQINGINDUSTRIAL AREA,GUANKOUTOWN,JIMEIDISTRICT,XIAMEN Telephone..........................:/ Fax.....................................:/ Factory............................:XIAMENMAKESECURITYTECHNOLOGYCO.,LTD Address..............................:NO.29,HOUSHANTOUROAD,SHENQINGINDUSTRIAL AREA,GUANKOUTOWN,JIMEIDISTRICT,XIAMEN Telephone..........................:/ Fax.....................................:/ Page4of9FCCID:2BDX6-R015VReportNo.:LCSC12225022EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000January13,2026InitialIssue--- Page5of9FCCID:2BDX6-R015VReportNo.:LCSC12225022EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS DescriptionPage 1.PRODUCTINFORMATION....................................................................................................................................6 2.EVALUATIONMETHODANDLIMIT.....................................................................................................................7 3.REFEREVALUATIONMETHOD..........................................................................................................................7 4.CONDUCTEDPOWER............................................................................................................................................8 5.EVALUATIONRESULTS........................................................................................................................................8 6.CONCLUSION...........................................................................................................................................................8 7.DESCRIPTIONOFTESTFACILITY.....................................................................................................................8 8.STATEMENTOFTHEMEASUREMENTUNCERTAINTY...............................................................................9 Pa…
Text truncated - open the document above for the full version.
Antenna name漡PCB antennaȼ Antenna model漡PCB-ANT-01ȼ manufacturer 漡 XIAMEN MAKE SECURITY TECHNOLOGY CO.,LTDȼ Company address漡NO.29, HOUSHANTOU ROAD, SHENQING INDUSTRIAL AREA, GUANKOU TOWN, JIMEIDISTRICT,XIAMENȼ Antenna dimension drawing漡 We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required Antenna gain: 0dBi max Frequency range: 433.92MHz
Page1of28FCCID:2BDX6-R015VReportNo.:LCSC12225022EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For RVLOCK&CO,LLC KeyFOB TestModel:KeyFOB Preparedfor:RVLOCK&CO,LLC Address:1770WEST2690SOUTHWELLSVILLE,UT84339 Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:December22,2025 Numberoftestedsamples:2 SampleNo.:C251222017-1,C251222017-2 Serialnumber:Prototype DateofTest:December22,2025~January12,2026 DateofReport:January13,2026 Page2of28FCCID:2BDX6-R015VReportNo.:LCSC12225022EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15C(15.231) ReportReferenceNo. .................. :LCSC12225022EA DateofIssue .................................... :January13,2026 TestingLaboratoryName...........:GuangzhouLCSComplianceTestingLaboratoryLtd. Address.............................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure......... :FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName..........................:RVLOCK&CO,LLC Address.............................................:1770WEST2690SOUTHWELLSVILLE,UT84339 TestSpecification Standard...........................................:FCCCFR47PART15SubpartC,ANSIC63.10-2020 TestReportFormNo...................:TRF-4-E-176A/0 TRFOriginator.................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF ...................................... :Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription..................:KeyFOB TradeMark.......................................: N/A TestModel.......................................: KeyFOB Ratings..............................................:PleaseRefertoPage6 Result................................................:PASS Compiledby:Supervisedby:Approvedby: AceYao/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of28FCCID:2BDX6-R015VReportNo.:LCSC12225022EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC12225022EA January13,2026 Dateofissue TestMode...........................:KeyFOB EUT....................................:KeyFOB Applicant...........................:RVLOCK&CO,LLC Address..............................:1770WEST2690SOUTHWELLSVILLE,UT84339 Telephone..........................:/ Fax.....................................:/ Manufacturer..................:XIAMENMAKESECURITYTECHNOLOGYCO.,LTD Address..............................:NO.29,HOUSHANTOUROAD,SHENQINGINDUSTRIAL AREA,GUANKOUTOWN,JIMEIDISTRICT,XIAMEN Telephone..........................:/ Fax.....................................:/ Factory............................:XIAMENMAKESECURITYTECHNOLOGYCO.,LTD Address..............................:NO.29,HOUSHANTOUROAD,SHENQINGINDUSTRIAL AREA,GUANKOUTOWN,JIMEIDISTRICT,XIAMEN Telephone..........................:/ Fax.....................................:/ Page4of28FCCID:2BDX6-R015VReportNo.:LCSC12225022EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000January13,2026InitialIssue-- Page5of28FCCID:2BDX6-R015VReportNo.:LCSC12225022EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)........................................................................................................................6 1.2.OBJECTIVE...........................................................................................................................................................7 1.3.ENVIRONMENTALCONDITIONS............................................................................................................................7 1.4.SUPPORTEQUIPMENTLIST.................................................................................................................................7 1.5.EXTERNALI/OPORT...........................................................................................................................................7 1.6.EUTOPERATION.................................................................................................................................................7 1.7.ANTENNASYSTEM...............................................................................................................................................7 1.8…
Text truncated - open the document above for the full version.
Page1of1FCCID:2BDX6-R015V GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestSetupPhotosoftheEUT RadiatedEmissionsMeasurement(30M-1GHz),20dBBandwidthEmissions Fig.1 RadiatedEmissionsMeasurement(Above1GHz) Fig.2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

RVLock Scout Camera
Equipment Class
DTS - Digital Transmission SystemBeacon
Equipment Class
DTS - Digital Transmission System
AXIS LATCH EXTENDER
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterTREK KEYLESS ENTRY HANDLE
Equipment Class
DTS - Digital Transmission System
RV LOCK BT PRO
Equipment Class
DTS - Digital Transmission System