Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhenPeichengTechnologyCo.,Ltd 5thFloor,Building64,BaotianIndustrialZone,ChentianCommunity,XixiangStreet,BaoanDistrict, ShenzhenCity,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-5-16 Towhomitmayconcern: We,ShenzhenPeichengTechnologyCo.,Ltd,herebycertifythattheequipmentforwhichauthorization issoughtFCCID:2BE3V-Q2isnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuantto§2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,wearenotidentifiedontheCovered List(https://www.fcc.gov/supplychain/coveredlist)asanentityproducing“covered”equipment. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(b)and(d)(5)and(6). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRas wellasKDB986446D01. Sincerely, Signature ShaobinChen Manager ShenzhenPeichengTechnologyCo.,Ltd 6 2 _ [ m o d e l ] C o v e r e d E q u _ 2 . 9 1 1 ( d ) ( 5 ) ( i ) a n d ( i i ) - U , V 0 3
ShenzhenPeichengTechnologyCo., Ltd 5th Floor, Building64, BaotianIndustrialZone, ChentianCommunity,XixiangStreet, Baoan District, ShenzhenCity, China FederalCommunicationsCommission Authorizationand EvaluationDivision EquipmentAuthorizationBranch 7435 OaklandMills Road Columbia,MD 21046 2024-5-16 U.S. AgentDesignation ShenzhenPeichengTechnologyCo., Ltdacknowledgestheir consentfor the followingcontactlocatedin the UnitedStatesto act as their agent for serviceof processfor the equipmentfor which authorizationis sought FCC ID:2BE3V-Q2 Nameand companyof U.S. agent: ACT Lab LLC PhysicalU.S. addressof agent: 3280 East 59th StreetLong Beach , CA 90805UnitedStates FRN of U.S. agent: 0033465568 Email addressof U.S. agent: [email protected] ACT Lab LLCacknowledgestheir obligationto acceptserviceof processon behalfof ShenzhenPeichengTechnologyCo., Ltd. ShenzhenPeichengTechnologyCo., Ltdwith the FRN0034963744acceptsits obligationto maintainan agent for serviceof processin the UnitedStatesfor no less than one year after eitherthe granteehas permanently terminatedall marketingand importationof the applicableequipmentwithinthe U.S., or the conclusionof any Commission-relatedadministrativeor judicialproceedinginvolvingthe equipment,whicheveris later. By signingthis form, we confirmthe aboveand that we are awareof the applicationrequirementslisted under§ 2.911(d)(7). The informationprovidedin this letter is basedon the referencedrule parts of Title 47 of the CFR as well as KDB 986446D01. An expirationdate for this letter does not exist. In case the U.S. agent changes,the granteeis obligatedto notify the FCC within 30 days via the grantingTCB. Sincerely, Signature ShaobinChen Manager ShenzhenPeichengTechnologyCo., Ltd Signature Scott Huber SeniorTechnicalDirector ACT Lab LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
ShenzhenPeichengTechnologyCo.,Ltd Add:5thFloor,Building64,BaotianIndustrialZone,ChentianCommunity,Xixiang Street,BaoanDistrict,ShenzhenCity,China Date:2024-5-16 FCCID:2BE3V-Q2 DearSir/Madam, We,ShenzhenPeichengTechnologyCo.,LtdHerebydeclaresthefollowingstatementfor FederalCommunicationsCommission,PCBboard,circuit,structureandinternalofthese model(s)arethesame,Onlyappearanceandmodelnamesisdifferentforthesemodel: Productname:Tablet Modelno.:Q2,Q2S,Q2K Sincerely, Name/Title : ShaobinChen/Manager Company: ShenzhenPeichengTechnologyCo.,Ltd Address: 5thFloor,Building64,BaotianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,ShenzhenCity, China Phone: 15818750927 Fax: 0755-26509195 E-Mail: [email protected]
CONFIDENTIALITYREQUEST forCertificationServiceinUSA FederalCommunicationCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21046 Date:<2024-5-16> PursuanttoParagraphs§0.457and0.459oftheCommission’sRules(47C.F.R.)and Section§552(b)(4)oftheFreedomofInformationAct,werequestsconfidentialityfor thefollowingproducts: FCCIDModelname 2BE3V-Q2Q2 Fortheproductstatedabove,werequestthatthefollowinginformationbeheld confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term ConfidentialityDays ExternalPhotos InternalPhotos BlockDiagram Schematics TestSetupPhotos User’sManual PartsList TuneUp OperationalDescriptions Thelong-termconfidentialityexhibitscontainourtradesecretsandproprietary informationthatcouldbeofbenefittoourcompetitors. Theshort-termconfidentialityonthebasisofensuringthatbusinesssensitive informationremainsconfidentialuntiltheactualmarketingofournewdevice. Ifyouhaveanyquestions,pleasefeelfreetocontactmeattheaddressshownbelow. Sincerely, Name/Title: ShaobinChen/Manager Company: ShenzhenPeichengTechnologyCo.,Ltd Address: 5thFloor,Building64,BaotianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,ShenzhenCity, China Phone: 15818750927 Fax: 0755-26509195 E-Mail: [email protected]
ShenzhenPeichengTechnologyCo.,Ltd 5thFloor,Building64,BaotianIndustrialZone,ChentianCommunity,XixiangStreet,BaoanDistrict, ShenzhenCity,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-5-16 Towhomitmayconcern: We,ShenzhenPeichengTechnologyCo.,Ltdtheundersigned,herebyauthorizeEurofinsProduct ServiceGmbHtoactonourbehalfinallmattersrelatingtoapplicationsforequipmentauthorization FCCID:2BE3V-Q2includingthesigningofalldocumentsrelatedtothesematters. AnyandallactscarriedoutbyEurofinsProductServiceGmbHonourbehalfshallhavethesame effectasactsofourown. Bysigningthisapplicationform,weagreetoEurofins’currentvalidGeneralTermsandConditions (AGB),TestingandCertificationRegulations(PZO)whichcanbeviewedonfollowingwebsite www.eurofins.de/eeorretrievedonrequest. Wealsoherebycertifythatnopartytothisapplicationissubjecttoadenialofbenefits,includingFCC benefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.862. Sincerely, Name/Title : ShaobinChen/Manager Company: ShenzhenPeichengTechnologyCo.,Ltd Address: 5thFloor,Building64,BaotianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,ShenzhenCity, China Phone: 15818750927 Fax: 0755-26509195 E-Mail: [email protected]
FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo 7 Appearance of EUT
FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Appendix IID Label Tablet FCC ID: 2BE3V-Q2 Model: Q2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Appendix II ID Label Location
FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 8 Internal of EUT Photo 9 Battery parameters BLE/BT/2.4GWi-Fi Antenna FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo 10 Appearance of PCB Photo 11 Appearance of PCB FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo 12 Appearance of PCB Photo 8 Appearance of PCB
Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202404-0010-6 Page: 1 of 4 TB-RF-074-1.0 1 A/F., Building.6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao’an, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Exposure Evaluation FCC ID: 2BE3V-Q2 1. Client Information Applicant : Shenzhen Peicheng Technology Co., Ltd Address : 5th Floor, Building 64, Baotian Industrial Zone, Chentian Community, Xixiang Street, Baoan District, Shenzhen City, China Manufacturer : Shenzhen Peicheng Technology Co., Ltd Address : 5th Floor, Building 64, Baotian Industrial Zone, Chentian Community, Xixiang Street, Baoan District, Shenzhen City, China 2. General Description of EUT EUT Name : Tablet Model(s) No. : Q2, Q2S, Q2K Model Difference : All PCB boards and circuit diagrams are the same, the only difference is that appearance and model names. Product Description : Operation Frequency: Bluetooth 5.2: 2402MHz~2480MHz 2.4G Wi-Fi: 2412MHz~2462MHz Antenna Gain: 1.30dBi FPC Antenna Power Supply : Input: 5V2A Li-ion Polymer Battery : 3.85V by 3000mAh Rechargeable Li-ion battery Software Version : PC-rk3326s_sgo__r8637_1g-Android12-2145+5648-8in-aic8800-2 +32-Q2-go-debug-20231229 Hardware Version : R862T-RK3326S-V1.0_C Remark: (1) The antenna gain provided by the applicant, the verified for the RF conduction test provided by TOBY test lab. (2) The above antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible. Note: More test information about the EUT please refer the RF Test Report. Report No.: TBR-C-202404-0010-6 Page: 2 of 4 TB-RF-074-1.0 SAR Test Exclusion Calculations 1. FCC: According to KDB 447498 D01 Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies v06. (1) Clause 4.3: General SAR test reduction and exclusion guidance Sub clause 4.31: Standalone SAR test exclusion considerations 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6GHz at test separation distance≤5 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation, mm)]*[√f (GHz) ] ≤3.0 for 1-g SAR [(max. power of channel, including tune-up tolerance, mW)/(min. test separation, mm)]*[√f (GHz) ] ≤7.5.0 for 10-g SAR 2. Summary simultaneous transmission for SAR Exclusion The SAR exemption limits outlined in clause 4.3.2(b) of KDB 447498 have been derived based on an approximate SAR value of 0.4 W/kg using half-wave dipole antennas Footnote 1. As such, when simultaneous transmitter SAR evaluations include transmitters that have been exempt from routine SAR evaluation, the SAR must be estimating based on the ratio between the maximum tune-up tolerance limit of the transmitter that has been exempt and the exemption limit at the specific distance and frequency for that transmitter. This ratio must be multiplied by 0.4 W/kg(2.0 W/kg for controlled use and 1.0 W/kg for limb worn devices) in order to calculate the estimated SAR level. The estimate SAR value is calculated based the following equation: (maximum power level including tune-up tolerance for transmitter A / maximum power level of exemption at the same frequency and distance) * 0.4W/kg The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. Report No.: TBR-C-202404-0010-6 Page: 3 of 4 TB-RF-074-1.0 3. Calculation: Test separation: 5mm Bluetooth (GFSK) Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.402 3.519 4±1 5 3.162 0.980 3.0 2.441 3.714 4±1 5 3.162 0.988 3.0 2.480 3.564 4±1 5 3.162 0.996 3.0 Bluetooth (Pi/4-DQPSK) Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.402 4.062 4±1 5 3.162 0.980 3.0 2.441 4.169 4±1 5 3.162 0.988 3.0 2.480 3.975 4±1 5 3.162 0.996 3.0 Bluetooth (8-DPSK) Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.402 4.482 4±1 5 3.162 0.980 3.0 2.441 4.357 4±1 5 3.162 0.988 3.0 2.480 4.265 4±1 5 3.162 0.996 3.0 Bluetooth LE (1Mbps) Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.402 3.131 3±1 4 2.512 0.779 3.0 2.440 3.204 3±1 4 2.512 0.785 3.0 2.480 3.113 3±1 4 2.512 0.791 3.0 Bluetooth LE (2Mbps) Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.402 3.361 3±1 4 2.512 0.779 3.0 2.440 3.543 4±1 5 3.162 0.988 3.0 2.480 3.45 3±1 4 2.512 0.791 3.0 2.4 G Wi-Fi 802.11b Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.412 7.04 7±1 8 6.310 1.960 3.0 2.437 7.43 7±1 8 6.310 1.970 3.0 2.462 7.55 8±1 9 7.943 2.493 3.0 Report No.: TBR-C-202404-0010-6 Page: 4 of 4 TB-RF-074-1.0 2.4 G Wi-Fi 802.11g Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dBm) Max power of tune up tolerance (mw) Calculation Value Threshold Value 2.412 7.52 8±1 9 7.943 2.467 3.0 2.437 7.36 7±1 8 6.310 1.970 3.0 2.462 7.03 7±1 8 6.310 1.980 3.0 2.4 G Wi-Fi 802.11n20 Frequency (GHz) Conducted Power (dBm) Turn-up Power Tolerance (dB) Max power of tune up tolerance (dB…
Text truncated - open the document above for the full version.
第 1 页 深圳市千目通讯科技有限公司 Shenzhen Qianmu Communication Technology Co.,Ltd. Antenna acknowledgement Applicable model Q2K client Shenzhen peicheng technology co., ltd Specification description Product contentspecifications Customer material code S p e c i f i c a t i o n d e s c r i p t i o n WIFI antenna FPC/ Black/Character QM-Q2K-V1.0+ Third-generation terminal wire /φ0.81*175mm+ conductive cloth Change resume serial number dateversionBrief description of changes one2022-04-29V1.0New project 2 three Supplier sample confirmation research and development structurecheckdecide PASSþ FAIL ̈ Customer sample confirmation electronstructureprojectpurchasequalitycheck Reasons for rejection or other precautions: 联系人:王志强 联系方式:13760153961 电话:0755-21633653 传真:0755-21633541 深圳市宝安区航城街道三围社区航空路华丰智谷-航城高科技产业园A座4层425、443号 第 2 页 1、Matching circuit -WIFI antenna The original matching circuit has not changed. 2、Active data WIFI2400~2500Mz 802.11b 11MBps Channelonesix11 TRP14.1914.7214.68 TIS-80.22-80.09-80.7 3、Antenna efficiency and gain 第 3 页 4、WIFI measured map 5、Schematic diagram of environmental treatment and antenna placement Stick conductive cloth on the copper leakage area of the antenna and ground the screen. Co nd uct ive vel vet is att ac he d to the fo ur pla ce 第 4 页 Conductive cloth is attached here, and the motherboard and screen are grounded. 5, structural drawings
Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 1 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 RF Test Data for Bluetooth(BR+EDR) (Conducted Measurements) General Description of EUT Product Name: Tablet Test Model: Q2 Sample ID: 202404-0010-4-2# Environmental Conditions Temperature: 25°C Relative Humidity: 55% Test Voltage: DC 3.85V Test Engineer: ZKN Zhou Note: For a more detailed features description, please refer to the report TBR-C-202404-0010-51 The report only show the worst case data. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 2 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Contents 1. Duty Cycle ........................................................................................................................................................................................... 3 2. Maximum Conducted Output Power ................................................................................................................................................. 9 3. -20dB Bandwidth .............................................................................................................................................................................. 15 4. Occupied Channel Bandwidth ......................................................................................................................................................... 21 5. Band Edge ........................................................................................................................................................................................ 27 6. Band Edge(Hopping) ........................................................................................................................................................................ 34 7. Conducted RF Spurious Emission .................................................................................................................................................. 41 8. Restrict Band .................................................................................................................................................................................... 51 9. Carrier Frequencies Separation....................................................................................................................................................... 58 10. Number of Hopping Channel ......................................................................................................................................................... 61 11. Dwell Time ....................................................................................................................................................................................... 64 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 3 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 1. Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT 1-DH1 2402 Ant1 30.95 5.09 2.56 NVNT 1-DH1 2441 Ant1 30.4 5.17 2.63 NVNT 1-DH1 2480 Ant1 31.2 5.06 2.56 NVNT 2-DH1 2402 Ant1 32 4.95 2.5 NVNT 2-DH1 2441 Ant1 32 4.95 2.5 NVNT 2-DH1 2480 Ant1 31.2 5.06 2.56 NVNT 3-DH1 2402 Ant1 31.2 5.06 2.56 NVNT 3-DH1 2441 Ant1 31.2 5.06 2.56 NVNT 3-DH1 2480 Ant1 31.2 5.06 2.56 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 4 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Test Graphs Duty Cycle NVNT 1-DH1 2402MHz Ant1 Duty Cycle NVNT 1-DH1 2441MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 5 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Duty Cycle NVNT 1-DH1 2480MHz Ant1 Duty Cycle NVNT 2-DH1 2402MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 6 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Duty Cycle NVNT 2-DH1 2441MHz Ant1 Duty Cycle NVNT 2-DH1 2480MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 7 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Duty Cycle NVNT 3-DH1 2402MHz Ant1 Duty Cycle NVNT 3-DH1 2441MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 8 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Duty Cycle NVNT 3-DH1 2480MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202404-0010-51 Page: 9 of 69 FCC ID: 2BE3V-Q2 TB-RF-074-1.0 2. Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT 1-DH1 2402 Ant1 3.519 21 Pass NVNT 1-DH1 2441 Ant1 3.714 21 Pass NVNT 1-DH1 2480 Ant1 3.564 21 Pass NVNT 2-DH1 2402 Ant1 4.062 21 Pass NVNT 2-DH1 2441 Ant1 4.169 21 Pass NVNT 2-DH1 2480 Ant1 3.975 21 Pass NVNT 3-DH1 2402 Ant1 4.482 21 Pass NVNT 3-DH1 2441 Ant1 4.357 21 Pass NVNT 3-DH1 2480 Ant1 4.265 21 Pass Shenzhen Toby Technology Co., Ltd. Http://ww…
Text truncated - open the document above for the full version.
Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202404-0010-51 Page: 1 of 58 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Radio Test Report FCC ID: 2BE3V-Q2 Original Grant Report No. : TBR-C-202404-0010-51 Applicant : Shenzhen Peicheng Technology Co., Ltd Equipment Under Test (EUT) EUT Name : Tablet Model No. : Q2 Series Model No. : Q2S, Q2K Brand Name : ---- Sample ID : 202404-0010-4-1# & 202404-0010-4-2# Receipt Date : 2024-04-19 Test Date : 2024-04-19 to 2024-05-15 Issue Date : 2024-05-15 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Tested By : ZKN Zhou Reviewed By : Camille Li Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202404-0010-51 Page: 2 of 58 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 6 1.1 Client Information ................................................................................................................. 6 1.2 General Description of EUT (Equipment Under Test) ................................................... 6 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 8 1.4 Description of Support Units .............................................................................................. 8 1.6 Description of Test Software Setting .............................................................................. 10 1.7 Measurement Uncertainty ................................................................................................ 10 1.8 Test Facility ......................................................................................................................... 11 2. TEST SUMMARY ..................................................................................................................... 12 3. TEST SOFTWARE ................................................................................................................... 12 4. TEST EQUIPMENT AND TEST SITE ................................................................................... 13 5. CONDUCTED EMISSION ....................................................................................................... 15 5.1 Test Standard and Limit .................................................................................................... 15 5.2 Test Setup ........................................................................................................................... 15 5.3 Test Procedure ................................................................................................................... 15 5.4 Deviation From Test Standard ......................................................................................... 16 5.5 EUT Operating Mode ........................................................................................................ 16 5.6 Test Data ............................................................................................................................. 16 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 17 6.1 Test Standard and Limit .................................................................................................... 17 6.2 Test Setup ........................................................................................................................... 18 6.3 Test Procedure ................................................................................................................... 19 6.4 Deviation From Test Standard ......................................................................................... 21 6.5 EUT Operating Mode ........................................................................................................ 21 6.6 Test Data ............................................................................................................................. 21 7. EMISSIONS IN RESTRICTED BANDS ............................................................................... 22 7.1 Test Standard and Limit .................................................................................................... 22 7.2 Test Setup ........................................................................................................................... 22 7.3 Test Procedure ................................................................................................................... 23 7.4 Deviation From Test Standard ......................................................................................... 25 7.5 EUT Operating Mode ........................................................................................................ 25 Report No.: TBR-C-202404-0010-51 Page: 3 of 58 TB-RF-074-1.0 7.6 Test Data ............................................................................................................................. 25 8. 99% OCCUPIED AND 20DB BANDWIDTH ........................................................................ 26 8.1 Test Standard and Limit .................................................................................................... 26 8.2 Test Setup ...............................................................................................…
Text truncated - open the document above for the full version.
FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Appendix V EUT Test Photographs Photo of Setup for Radiated Emission (Below 1 GHz) Photo of Setup for Radiated Emission (Above 1 GHz) FCC ID: 2BE3V-Q2 TB-RF-074-1.0 Photo of Setup for Radiated Emission (Above 1 GHz) Photo of Setup for Conducted Emission -----END OF REPORT-----
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.80 mW |

Tablet
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Tablet PC
Equipment Class
DTS - Digital Transmission System
Tablet PC
Equipment Class
DTS - Digital Transmission System
Speaker
Equipment Class
DTS - Digital Transmission System