FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Inlumen Technologies Co., Ltd./
  3. 2BHFB-5028-00

2BHFB-5028-00MINI2 Thermal Imaging Monocular

Inlumen Technologies Co., Ltd.
MINI2 Thermal Imaging Monocular - FCC ID 2BHFB-5028-00 - Inlumen Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 25, 2026
Application Purpose
Original Equipment
Equipment Note
MINI2 Thermal Imaging Monocular
Frequency Range
2412.00000000 - 2462.00000000
Company
Inlumen Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

All rights reserved and shall not be copied and distributed in any form without written permission NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission IMPORTANT SAFETY INFORMATION Environmental influences - Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage the interior components. - Avoid touching the metal surface (cooling fins) after exposure to sunlight or cold. Ergonomics notes Take breaks after longer periods of use to avoid wrist pain. Risk of swallowing Do not place this device in the hands of small children. Incorrect handling can cause small parts to come loose which may be swallowed. Safety instructions for use - Handle the device with care: rough handling can damage the internal battery. - Do not expose the device to fire or high temperatures. - Install the batteries correctly according to the instruction on the device. Reverse connection is prohibited. - The battery capacity decreases when operated in a cold ambient temperature. This is not a fault and occurs for technical reasons. - The recommended temperature for using this product is -20° to +50°. Otherwise, it will affect the service life of the product. - Do not store the device for long periods at temperatures below - 20°C or above 50°C, or it will permanently reduce the battery capacity. - Always store the device in a dry, well-ventilated space. - If the device has been damaged or the battery is defective, send the device to our after-sales service for repair. Safety instructions for the power supply unit - Check the power supply unit, cable and adapter for visible damage before use. NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission - Do not use any defective parts. Defective components must be replaced. - Do not use the power supply unit in wet or humid environments. - Only charge the device at temperatures ranging between 0°C and 50°C. - Do not make any technical modifications. Disposal of batteries Directive 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. For battery details, refer to the documentation of the specific product. The battery is marked with this symbol, which may include Cd (indicating cadmium), Pb (indicating lead), or Hg (indicating mercury). For proper recycling, please return the battery to your supplier or send it to a designated collection point. For more information, visit www.recyclethis.info. User information on the disposal of electrical and electronic devices (private households) 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. For business customers within the European Union Please contact your dealer or supplier regarding the disposal of electrical and electronic devices. He will provide you with further information. Information on disposal in other countries outside of the European Union This symbol is only applicable in the European Union. Please contact your local authority or dealer if you wish to dispose of this product and ask for a disposal option. Intended use The device is intended for displaying heat signatures during nature NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission observation, remote hunting observations and for civil use. This device is not a toy for children. Use the device only as described in this operating manual. The manufacturer and the dealer accept no liability for damages which arise due to non-intended or incorrect use. Function test - Before use, please ensure that your device has no visible damage. - Test to see if the device displays a clear, undisturbed image. - Check that the settings for the thermal imaging monocular are correct. See the notes in the section Power On and Image Settings. Installing/Removing the battery The MINI2 series thermal imaging monocular is equipped with built- in battery pack . The built-in battery pack cannot be removed. NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission 1 Specifications Product Model MINI2 H25 Thermal Module Image Sensor Uncooled Vox Resolution, pixel 640*512 Pixel Size, μm 12 NETD, mk ≤15 Frame Rate, Hz 60 Objective Lens F25mm /1.0 FOV 17..6*14.1 Detection Range, m (Target Size: 1.7m×0.5m, P(n)=99%) 1298 Optical Module Image Sensor 1/1.8'' CMOS Resolution 960x540 Pixel Size, μm 8 FOV 30.8*17.3 Objective Lens F 14.3/0.85 Eyepiece Diopter Adjustment, D -5~+5 Exit Pupil Diameter 17 mm Eye Relief, mm 25mm Display Type AMOLED Resolution, pixel 1280x1024 Size, inch 0.6inch Power Supply Battery Type/Capacity Internal Lithium-ion battery / 750mAh External battery pack / 4000mAh External Power Supply 5V (Type C USB) Physical Parameters Operating Time (t=22°C), h★ 7h IP Rate IP67 Memory Capacity, GB 32 Operating Temperature, ºC -20°C-50°C NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission Dimension 101.55*43.7*64.5 (without eyepiece) Weight, g 240g NOCPIX  MINI2  User Manual www.nocpix.com All rights reserved and shall not be copied and distributed in any form without written permission 2 Package Contents ⚫ MINI 2 series infrared thermal imager ⚫ Magnetic Charging Cable ⚫ USB-C Cable ⚫ Soft Case ⚫ Lens Cloth ⚫ Nocpix External Battery Pack NOCPIX  MINI2  Us…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: BTL-FCC SAR-1-2601H051_Appendix B. Page 1 of 1 Test Laboratory: BTL Inc. (Dongguan) Date: 2026/3/10 W08_WiFi 2.4G_802.11b_CH11_Back Side_0mm DUT: Test sample; Communication System: UID 10012 - CAB, IEEE 802.11b WiFi 2.4 GHz (DSSS, 1 Mbps); Frequency: 2462 MHz; Duty Cycle: 1:1 Medium parameters used: f = 2462 MHz; σ = 1.872 S/m; ε r = 39.662; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.9 °C DASY Configuration: • Probe: EX3DV4 - SN7544; ConvF(7.63,7.63,7.63) @2462 MHz; Calibrated: 2025/6/19 • Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 Sn420; Calibrated: 2025/4/8 • Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD000P40CB; Serial: TP:1469 • DASY52 52.10.4(1535); SEMCAD X 14.6.14(7501) Area Scan (10x14x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 1.36 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 27.62 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 3.63 W/kg SAR(1 g) = 1.30 W/kg; SAR(10 g) = 0.439 W/kg Smallest distance from peaks to all points 3 dB below = 5.1 mm Ratio of SAR at M2 to SAR at M1 = 40.5% Maximum value of SAR (measured) = 2.33 W/kg

Test Setup Photos

Report No.: BTL-FCC SAR-1-2601H051_Appendix D. Page 1 of 2 Appendix D. Photographs of the Test Set-Up Photo 1: Front Side _0mm Photo 2: Back Side _0mm Photo 3: Left Side_0mm Photo 4: Right Side_0mm EUT Photo 5: Top Side_0mm EUT Photo 6: Bottom Side_0mm Report No.: BTL-FCC SAR-1-2601H051_Appendix D. Page 2 of 2 EUT Photo 7: Front Side View EUT Photo 8: Back Side View

Test Report

Internal files, please do not disclose without permission * D a t a s h e e t P/N:ZY-YJ-WF-001 customer: 合肥影炬创新技术有限公司 Band: 2.4G-WIFI Connect:IPEX-1 Cable:coaxial cable1.13-42mm(Black) Specification Antenna Performance Testing Product Drawing 1 2 3 ZY Antenna makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. ZY Antenna reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. ................................................ .......................................... ....................... 1 2 7 1 1. S pecification Frequency: 2400-2500MHZ Input Impedance: 50Ω V.S.W.R: ≤2.0 Gain: [email protected] Polarization Type: Linear Passive Electrical Specifications Mechanical Specifications Antenna Size:25.13*14.55*0.2 Material:metal Connector Type:IPEX-1 Cable:42mm Working Temperature: -40~85°C 2 2. Antenna Performance Testing Test equipment: Satimo24G microwave laboratory+E5071C network analyzer 3 S11 2.1 4 TEST(Efficiency&Gain) 2.2 5 2D-2450MHZ 2.3 3D-2450MHZ 2.4 6 3. Product Drawing 7

RF Exposure Info

Report No.: BTL-FCC SAR-1-2601H051_Appendix A. Page 1 of 1 Test Laboratory: BTL Inc. (Dongguan) Date: 2026/3/10 System Check_H2450_0310 DUT: Dipole 2450 MHz D2450V2;SN:919; Communication System: UID 0, CW (0); Frequency: 2450 MHz; Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.862 S/m; ε r = 39.685; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.9 °C DASY Configuration: •Probe: EX3DV4 - SN7544; ConvF(7.63,7.63,7.63) @2450 MHz; Calibrated: 2025/6/19 •Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 •Electronics: DAE4 Sn420; Calibrated: 2025/4/8 •Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD000P40CB; Serial: TP:1469 •DASY52 52.10.4(1535); SEMCAD X 14.6.14(7501) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 6.55 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 70.72 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 11.4 W/kg SAR(1 g) = 5.37 W/kg; SAR(10 g) = 2.44 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to SAR at M1 = 47.1% Maximum value of SAR (measured) = 9.16 W/kg

RF Exposure Info

Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 1 of 30 FCC SAR Test Report FCC ID: 2BHFB-5028-00 Project No. : 2601H051 Equipment : MINI2 Thermal Imaging Monocular Brand Name : Nocpix Model Name : H25 Date of Receipt : Feb. 03, 2026 Date of Test : Mar. 06, 2026 ~ Mar. 12, 2026 Issued Date : Mar. 18, 2026 Test Sample : Engineering Sample No.: SH92026020319 Standard(s) : Please refer to page 2. Applicant : Inlumen Technologies Co., Ltd. Address : Room 806, A1, Phase 3, lnnovation Industrial Park,High-tech Zone, Hefei City, Anhui Province, China. Manufacturer : Inlumen Technologies Co., Ltd. Address : Room 806, A1, Phase 3, lnnovation Industrial Park,High-tech Zone, Hefei City, Anhui Province, China. The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Dana Chen Approved by : Herbort Liu No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 2 of 30 Standard(s) : IEEE Std C95.1:2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 kHz to 300 GHz IEEE Std 1528 TM -2013 IEEE Recommended Practice for Determining the Peak Spatial- Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques KDB865664 D01 SAR measurement 100 MHz to 6 GHz v01r04 KDB447498 D01 General RF Exposure Guidance v06 Test Method : KDB865664 D02 SAR Reporting v01r02 KDB248227 D01 802. 11 Wi-Fi SAR v02r02 Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 3 of 30 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 4 of 30 Table of Contents Page REVISION HISTORY 6 1 . GENERAL INFORMATION 7 1.1 STATEMENT OF COMPLIANCE 7 1.2 LABORATORY ENVIRONMENT 7 1.3 GENERAL DESCRIPTION OF EUT 8 1.4 MAIN TEST INSTRUMENTS 9 2 . RF EMISSIONS MEASUREMENT 10 2.1 TEST FACILITY 10 2.2 MEASUREMENT UNCERTAINTY 10 3 . SAR MEASUREMENTS SYSTEM CONFIGURATION 11 3.1 SAR MEASUREMENT SET-UP 11 3.1.1 TEST SETUP LAYOUT 11 3.2 DASY5 E-FIELD PROBE SYSTEM 12 3.2.1 PROBE SPECIFICATION 12 3.2.2 E-FIELD PROBE CALIBRATION 13 3.2.3 OTHER TEST EQUIPMENT 14 3.2.4 SCANNING PROCEDURE 15 3.2.5 SPATIAL PEAK SAR EVALUATION 16 3.2.6 DATA STORAGE AND EVALUATION 17 3.2.7 DATA EVALUATION BY SEMCAD 18 4 . SYSTEM VERIFICATION PROCEDURE 20 4.1 TISSUE VERIFICATION 20 4.2 SYSTEM CHECK 21 4.3 SYSTEM CHECK PROCEDURE 21 5 . SAR MEASUREMENT VARIABILITY AND UNCERTAINTY 22 5.1 SAR MEASUREMENT VARIABILITY 22 6 . OPERATIONAL CONDITIONS DURING TEST 23 6.1 TEST POSITION 23 6.2 TEST CONFIGURATION 24 7 . TEST RESULT 25 7.1 CONDUCTED POWER RESULTS 25 7.1.1 CONDUCTED POWER MEASUREMENTS OF WIFI 2.4G 25 7.2 SAR TEST RESULTS 26 7.2.1 SAR MEASUREMENT RESULT 27 Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 5 of 30 Table of Contents Page 8 MULTIPLE TRANSMITTER EVALUATION 28 APPENDIX 29 1. TEST LAYOUT 29 Appendix A. SAR Plots of System Verification Appendix B. SAR Plots of SAR Measurement Appendix C. Calibration Certificate Appendix D. Photographs of the Test Set-Up Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 6 of 30 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCC SAR-1-2601H051 R00 Original Report. Mar. 18, 2026 Valid Report No.: BTL-FCC SAR-1-2601H051 Report Version: R00 Page 7 of 30 1. GENERAL INFORMATION 1.1 STATEMENT OF COMPLIANCE Mode Highest Bodyworn SAR-1g (W/kg) 2.4G WLAN 1.439 Note: The device is in compliance with Specific Absorption Rate (SAR) for general population uncontrolled exposure limits according to the FCC rule §2.1093, the ANSI/IEEE C95.1, the NCRP Report Number 86 for uncontrolled environment, and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528. 1.2 LABORATORY ENVIRONMENT Te mperature Min. = 18ºC, Max. = 25ºC Relative humidity Min. = 30%, Max…

Text truncated - open the document above for the full version.

External Photos

External Photos Documentation Manufacturer: Inlumen Technologies Co., Ltd. Page 1 of 3 Product: MINI2 Thermal Imaging Monocular FCC ID: 2BHFB-5028-00 Model: H25 External Photos Documentation Manufacturer: Inlumen Technologies Co., Ltd. Page 2 of 3 Product: MINI2 Thermal Imaging Monocular FCC ID: 2BHFB-5028-00 Model: H25 External Photos Documentation Manufacturer: Inlumen Technologies Co., Ltd. Page 3 of 3 Product: MINI2 Thermal Imaging Monocular FCC ID: 2BHFB-5028-00 Model: H25

Cover Letter(s)

Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China Date (05/03/2026) TUV SUD America Inc. 10 Centennial Drive Peabody, MA 01960, USA Dear Sir or Madam, We, (Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China.), hereby authorize Wenqiang LU from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151 Heng Tong Road Shanghai 201108 P.R. China, to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on (Dec.31,2026). Yours sincerely, Name: Shirley fu Email: [email protected]

Cover Letter(s)

Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China Date (05/03/2026) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request FCC ID: 2BHFB-5028-00 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Inlumen Technologies Co., Ltd.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation PCB layout (Inlumen Technologies Co., Ltd.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (can list up to 180) days: Internal Photos The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Name: Shirley fu Title: [email protected]

Attestation Statements

WIFI Channel 12 ,13 and 14 Declaration Letter We declare the equipment identified below with regards to Channel 12,13 and 14 capabilities for FCC ID: 2BHFB-5028-00 Declaration Product hardware does not have the capability to operate on Channel 12,13 and 14. Product hardware has the capability to operate on Channel 12 ,13 and 14. However, these three channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 ,13 and 14. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 ,13 and 14, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo-location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, lnnovation Industrial Park, High-tech Zone, 230061 Hefei City, Anhui Province, PEOPLE'S REPUBLIC OF CHINA Name / Title: Shirley fu Signature: Email: [email protected] Date: 2026/03/05 Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, lnnovation Industrial Park, High-tech Zone, 230061 Hefei City, Anhui Province, PEOPLE'S REPUBLIC OF CHINA

Attestation Statements

Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China Data: 2026-03-05 Subject: Statement of disable RF chip AP6214A by software FCC ID: 2BHFB-5028-00 To Whom It May Concern: We Inlumen Technologies Co., Ltd. (Address: Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China.) hereby declare that although the RF chip AP6214A can support different frequencies and Modulation as following table Inlumen Technologies Co., Ltd. Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China Our product is only locked to operate at frequency and Modulation (as following table) by software. this setting is not accessible and can’t active by the user or any other third-party. Best Regards Contact name: Shirley fu Company name: Inlumen Technologies Co., Ltd. Address: Room 806, A1, Phase 3, Innovation Industrial Park, High-tech Zone, Hefei City, Anhui Province, China. E-mail: [email protected]

Contact Information

Applicant

shirley fu
[email protected]Fax: 400-999-3800

Technical Contact

iRay USA, LLCTyler Adair
[email protected]

2601 State Hwy 121 Building 3 Suite 302 · Lewisville, Texas, 75056

Test Firm

BTL Inc. (Shanghai)Riley Wei
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz16.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory is 1.44 W/kg.

Other Applications from Inlumen Technologies Co., Ltd.

Magic Zoom - FCC ID 2BHFB-MATE-00 - Inlumen Technologies Co., Ltd.
2BHFB-MATE-00

Magic Zoom

Aug 10, 2026

Equipment Class

DTS - Digital Transmission System
Nocpix Remote Control - FCC ID 2BHFB-MATE-01 - Inlumen Technologies Co., Ltd.
2BHFB-MATE-01

Nocpix Remote Control

Aug 10, 2026

Equipment Class

DTS - Digital Transmission System
Mate Series Thermal Imaging Attachment - FCC ID 2BHFB-4071-00 - Inlumen Technologies Co., Ltd.
2BHFB-4071-00

Mate Series Thermal Imaging Attachment

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
Digital Night Vision Scope - FCC ID 2BHFB-4066-00 - Inlumen Technologies Co., Ltd.
2BHFB-4066-00

Digital Night Vision Scope

Jun 01, 2026

Equipment Class

DTS - Digital Transmission System
2BHFB-5041-00

Remote Control

May 05, 2026

Equipment Class

DTS - Digital Transmission System