Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCCCaution: Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2) thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay cause undesired operation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecould void the user's authorityto operatetheequipment. Note: This equipment has been tested and found to complywiththelimitsforaClass B digital device, pursuant to part 15 of the FCC Rules.Theselimitsaredesignedto provide reasonable protection against harmful interferenceinaresidentialinstallation. This equipment generates uses and can radiate radio frequencyenergyand,ifnot installed and used in accordance with the instructions, maycauseharmfulinterference to radio communications. However, there is no guaranteethatinterferencewillnot occur in a particular installation. If this equipment doescauseharmfulinterferenceto radio or television reception, which can be determinedbyturningtheequipmentoff and on, the user is encouraged to try to correct the interferencebyoneormoreofthe following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit differentfromthattowhichthe receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposurerequirement.The device can be used in portable exposure condition without restriction. myWaves Memory Headband
myWavesTechnologiesLimited 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:myWavesTechnologiesLimited Address:UnitJ,15/F.,TALBuilding,49AustinRoad,Kowloon,HongKong ProductName:myWavesMemoryHeadband FCCID:2BKL8-HM Model(s):HM 2.911(d)(5)(i)EquipmentType We,[myWavesTechnologiesLimited](“theapplicant”)certifythattheequipmentforwhich authorizationissoughtthroughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:KimberlyWhileyDate:2024.9.2 TitleandCompanyname:Manager/myWavesTechnologiesLimited NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
myWavesTechnologiesLimited 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:myWavesTechnologiesLimited Address:UnitJ,15/F.,TALBuilding,49AustinRoad,Kowloon,HongKong ProductName:myWavesMemoryHeadband FCCID:2BKL8-HM Model(s):HM 2.911(d)(5)(ii)Applicantfiling We,[myWavesTechnologiesLimited](“theapplicant”)certifythat,asofthedateofthefilingofthe application,theapplicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto §1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:KimberlyWhileyDate:2024.9.2 TitleandCompanyname:Manager/myWavesTechnologiesLimited NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
myWavesTechnologiesLimited 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:myWavesTechnologiesLimited Address:UnitJ,15/F.,TALBuilding,49AustinRoad,Kowloon,HongKong ProductName:myWavesMemoryHeadband FCCID:2BKL8-HM Model(s):HM 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[myWavesTechnologiesLimited](“theapplicant”)designate[StoneTrading Limited] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfofthe applicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:StoneTradingLimited USAAddress:6547NAcademyBlvd #2266,ColoradoSprings,CO80918,United States FRNNumber:0033401936 ContactName:DongmeiFang TelephoneNo:+12134573118 Email:[email protected] Applicant Companyname:myWavesTechnologies Limited Address:UnitJ,15/F.,TALBuilding,49 AustinRoad,Kowloon,HongKong GranteeFRNNumber:0035872506 FCCGranteeCode:2BKL8 ContactName:KimberlyWhiley TelephoneNo:852-27306633 Email:[email protected] Signature: Title:Manager Signature: Title:Manager Date:2024-09-02Date:2024-09-02 myWavesTechnologiesLimited 2.911(d)(7)USAAgentv1.5 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
myWavesTechnologiesLimited AgentAuthorization Company:myWavesTechnologiesLimited Address:UnitJ,15/F.,TALBuilding,49AustinRoad,Kowloon,HongKong ProductName:myWavesMemoryHeadband ModelNumber(s):HM ProductDescription:myWavesMemoryHeadband WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2024.9.2 Name:KimberlyWhiley Title:Manager Company:myWavesTechnologiesLimited
myWavesTechnologiesLimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024.9.2 Subject;RequestforConfidentiality FCCID:2BKL8-HM ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:KimberlyWhiley Title:Manager
EUT PHOTO(External Photos)
Label & label location 20mm*10mm FCC ID:2BKL8-HM Label location
EUT PHOTO(Internal Photos) ANT
RF EXPOSURE EVALUATION METHOD FCC ID:2BKL8-HM Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. EDR Mode Max Power(dBm) Max Power(mW) Frequency(MHz) Min. distance(mm) Calc. thresholds limit GFSK -5.893 0.26 2402 5 0.08 3.0 π/4DQPSK -5.174 0.30 2402 5 0.09 3.0 8DPSK -4.510 0.35 2402 5 0.11 3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.
Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.25 -0.76 -0.56 -5.24 -2.45 -1.87 MAX. Gain -0.56dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -1.25385 -30.0103 -7.12356 2450 -0.760408 -36.2309 -7.38028 2500 -0.564906 -22.0120 -6.42306 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -5.2426 -21.8636 -12.0129 2450 -2.4503 -24.1659 -10.1367 2500 -1.87256 -29.8203 -9.36204
Project No.: ZKT-24081510007E Page 1 of 70 FCC TEST REPORT FCC ID:2BKL8-HM Report Number. ................................ : ZKT-24081510007E Date of Test ..................................................: Aug. 15, 2024 to Aug. 22, 2024 Date of issue ..................................... : Aug. 22, 2024 Total number of pages ....................... 70 Test Result ...................................... : PASS Testing Laboratory. ........................ : Shenzhen ZKT Technology Co., Ltd. Address ........................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : myWaves Technologies Limited Address ........................................... : Unit J, 15/F., TAL Building, 49 Austin Road, Kowloon, Hong Kong Manufacturer's name ................... : myWaves Technologies Limited Address ........................................... : Unit J, 15/F., TAL Building, 49 Austin Road, Kowloon, Hong Kong Test specification: Standard ........................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test procedure ................................. : / Non-standard test method .............. : N/A Test Report Form No. .................... : / Test Report Form(s) Originator .... : ZKT Testing Master TRF ................................... : Dated: 2020-01-06 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : myWaves Memory Headband Trademark ....................................... : myWaves Model/Type reference ....................... : HM Ratings .............................................. : Input: 5V1A Battery: 3.7V 300mAh, 1.11Wh Project No.: ZKT-24081510007E Page 2 of 70 Testing procedure and testing location: Testing Laboratory ................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Jim Liu Tested by (name + signature) .................... : Jeff Fu Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-24081510007E Page 3 of 70 Table of Contents Page 1. VERSION .............................................................................................................. 5 2. TEST SUMMARY .................................................................................................. 6 2.1 TEST FACILITY ................................................................................................... 7 2.2 MEASUREMENT UNCERTAINTY ...................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT .................................................................... 8 3.2 Test Setup Configuration ..................................................................................... 9 3.3 Support Equipment .............................................................................................. 9 4. EMC EMISSION TEST ........................................................................................ 12 4.1 Conducted emissions ........................................................................................ 12 4.1.1 POWER LINE CONDUCTED EMISSION Limits ............................................ 12 4.1.2 TEST PROCEDURE ...................................................................................... 12 4.1.3 DEVIATION FROM TEST STANDARD .......................................................... 12 4.1.4 TEST SETUP ................................................................................................. 13 4.1.5 EUT OPERATING CONDITIONS ................................................................... 13 4.1.6 Test Result ..................................................................................................... 14 4.2 Radiated emissions ........................................................................................... 16 4.2.1 Radiated Emission Limits ............................................................................... 16 4.2.2 TEST PROCEDURE ...................................................................................... 16 4.2.3 DEVIATION FROM TEST STANDARD .......................................................... 17 4.2.4 TEST SETUP ................................................................................................. 17 4.2.5 EUT OPERATING CONDITIONS ................................................................... 18 4.2.6 TEST RESULTS ............................................................................................. 18 5. RADIATED BAND EMISSION MEASUREMENT ............................................... 27 5.1 Test Requirement: ............................................................................................. 27 5.2 TEST PROCEDURE ......................................................................................... 27 5.3 DEVIATION FROM TEST STANDARD ............................................................. 28 5.4 TEST SETUP .................................................................................................... 28 5.5 EUT OPERATING CONDITIONS ...................................................................... 28 5.6 TEST RESULT .................................................................................................. 29 6. CONDUCTED BAND EDGE AND …
Text truncated - open the document above for the full version.
EUT TEST PHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 350.00 µW |
Asset Tag
Equipment Class
DTS - Digital Transmission System
myWaves Bluetooth Headband
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter