Technical Specifications
| # | Rule Parts | Frequency Range | Power Output |
|---|
| 1 | 15E | 5.96 GHz - 7.09 GHz | 39.00 mW |
| 2 | 15E | 5.96 GHz - 6.42 GHz | 77.00 mW |
| 3 | 15E | 6.54 GHz - 6.86 GHz | 60.00 mW |
Grant NotesOutput power listed is EIRP.
This device supports 2x2 MIMO operations and bandwidths up to 80MHz.
The highest reported SAR values for head, body-worn accessory, extremity (10g), and simultaneous transmission exposure conditions are 1.12 W/Kg, 0.94 W/Kg, 0.30 W/Kg, 0.84 W/Kg (10g), and 1.59 W/Kg respectively. To satisfy FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
HAC-2019. Conversational gain values of 14.3 dB (with hearing aid) and 19.1 dB (without hearing aid). HAC compliance assessed under waiver DA 23-914.