FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lenovo (Beijing) Limited/
  3. A5MSM8866

A5MSM8866Wireless Mouse

Lenovo (Beijing) Limited

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 31, 2025
Application Purpose
Original Equipment
Equipment Note
Wireless Mouse
Frequency Range
2402.00000000 - 2480.00000000
Company
Lenovo (Beijing) Limited
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_03 06-06-2024 Lenovo (Beijing) Limited Certification Application Attestation Statements Lenovo (Beijing) Limited 0032905564 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District, Beijing China Subject: FCC ID: A5MSM8866 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Lenovo (Beijing) Limited certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Lenovo (Beijing) Limited (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2025-12-18 City: Beijing Name (2) : Yang Liu Function: Compliance Engineer Telephone number: (86)10-58867473 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_03 06-06-2024 Lenovo (Beijing) Limited

Attestation Statements

Grantee FRN: 0032905564

Cover Letter(s)

RF_160_06 Declaration of Authorisation Date of issue 13-08-2025 Lenovo (Beijing) Limited Declaration of Authorization We Name: Lenovo (Beijing) Limited Address: 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District, City: Beijing Country: China Declare that: Name Representative of agent: Ms. Grace Chen ) Agent Company name: BTL Inc. Address: 4F., No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., City: Taipei City Country 114 Taiwan is authorized to apply for Certification of the following product(s): Product description: Wireless Mouse Type designation: SM8866 Trademark: Lenovo Validity/ expiry date 2026/12/17 on our behalf. Date: 2025-12-18 City: Beijing Name: Yang Liu Function: Compliance Engineer Signature:  . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 1 of 2 Company Name: Lenovo (Beijing) Limited Address: 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District, City: Beijing Country: China To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: A5MSM8866 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: we request short-term confidential treatment for the following information until 180 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device. Date: 2025-12-18 Name and signature of applicant: Yang Liu Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 2 of 2 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

ID Label/Location Info

R-R-LVK-SM8866 CAN ICES (B) / NMB (B) Mouse Rating Made in China/ Model SM8866 /鼠标 IC: 5903G-SM8866 FCC ID: A5MSM8866 中国制造 / 额定电压电流: / 型号: Complies with IMDA Standards DB102306 E145614C3 5V 500mA

RF Exposure Info

Report No.: BTL-FCCP-3-2511T035 Project No.: 2511T035 Page 1 of 8 Report Version: R00 FCC SAR Exclusion Report FCC ID: A5MSM8866 Report No. : BTL-FCCP-3-2511T035 Equipment : Wireless Mouse Model Name : SM8866 Brand Name : Lenovo Applicant : Lenovo (Beijing) Limited Address : 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District,Beijing China Standard(s) : 47 CFR § 2.1093 IEEE C95.1 Date of Receipt : 2025/11/19 Date of Test : 2025/12/3 ~ 2025/12/11 Issued Date : 2025/12/18 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-3-2511T035 Project No.: 2511T035 Page 2 of 8 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-3-2511T035 Project No.: 2511T035 Page 3 of 8 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-3-2511T035 R00 Original Report. 2025/12/18 Valid Report No.: BTL-FCCP-3-2511T035 Project No.: 2511T035 Page 4 of 8 Report Version: R00 1. LIMITS According to § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit for occupational/controlled exposure is 20 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). Exposure may be averaged over a time period not to exceed 6 minutes to determine compliance with occupational/controlled SAR limits. (c) The SAR limits for general population/uncontrolled exposure are 0.08 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 1.6 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit is 4 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). Exposure may be averaged over a time period not to exceed 30 minutes to determine compliance with general population/uncontrolled SAR limits. (e) Limits for Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic fields (Table 1). Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *(100) ≤6 3.0-30 1842/f 4.89/f *(900/f 2 ) <6 30-300 61.4 0.163 1.0 <6 300-1.500 f/300 <6 1.500-100.000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1.500 f/1500 <30 1.500-100.000 1.0 <30 f = frequency in MHz. * = Plane-wave equivalent power density. Report No.: BTL-FCCP-3-2511T035 Project No.: 2511T035 Page 5 of 8 Report Version: R00 2. APPLIED EXEMPTION CRITERIA Refer to KDB 447498 D04, ticked item is applied: For RF Exposure Test Exemptions for Single Source: ☐ 1-mW Test Exemption Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-ANT-2511T035 Page 1 of 13 ANT Test Report Antenna Type: Chip Antenna EUT Photo Report No.: BTL-ANT-2511T035 Page 2 of 13 Project No. : 2511T035 Product Type : Chip Antenna Brand Name : LITEON Test Model : SM8866 Date of Receipt : 2025/11/13 Date of Test : 2025/11/13 Issued Date : 2025/11/13 Report Version : R00 Test Sample : WAN223216F2451SH08 Standard(s) : NSI IEEE Std 149 Applicant : LITEON Technology Corporation Address : No.392, Ruiguang Road, Neihu District, Taipei City 114 Manufacturer : LITEON Technology Corporation Address : No.392, Ruiguang Road, Neihu District, Taipei City 114 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Cliff Tsai,Engineer Approved by : Eric Lee, Manager Tel: +886-2265-2384 www.btl.com.tw Service mail: [email protected] Report No.: BTL-ANT-2511T035 Page 3 of 13 Table of Contents REPORT ISSUED HISTORY ........................................................................................... 4 1 . PHYSICAL LAYOUT AND SITE DESCRIPTION ....................................................... 6 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY .......................................................................... 6 1.2 ANECHOIC CHAMBER ........................................................................................................................ 6 1.3 QUIET ZONE ........................................................................................................................................ 7 1.4 TEST EQUIPMENT .............................................................................................................................. 7 1.5 AMS32 SOFTWARE ............................................................................................................................. 7 TEMPERATURE, HUMIDITY .......................................................................................... 7 2 . TEST EQUIPMENT LIST .......................................................................................... 11 2.1 TEST EQUIPMENT USED FOR MEASURING .................................................................................. 11 3 . PHOTOGRAPH ........................................................................................................ 13 3.1 EUT SETUP PHOTO .......................................................................................................................... 13 Report No.: BTL-ANT-2511T035 Page 4 of 13 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-ANT-2511T035 R00 Original Report. 2025-11-13 Valid TEST FACILITY & Contact Information Test Lab. Address BTL. Inc No. 72, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan Report No.: BTL-ANT-2511T035 Page 5 of 13 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by CNAS or any other agency. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-ANT-2511T035 Page 6 of 13 1. PHYSICAL LAYOUT AND SITE DESCRIPTION 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY All tests were performed in BTL Inc. state-of-the-art Wireless Mobile Device Test Laboratory consisting of a rectangular anechoic chamber equipped with a Conical cut positioning system for WPTC-L chambers. A base station simulator is used to establish communication with the EUT and place it in the proper mode, and a spectrum analyzer and RF switch combination is used for measuring the signal from the EUT at each position and polarization. BTL Inc.’s AMS32 System Software and Contest Sequencer Software are used for data acquisition, post-processing, and generation of the required output. 1.2 ANECHOIC CHAMBER The anechoic chamber is a rectangular anechoic chamber designed and built by Rohde & Schwarz with the following nominal dimensions Length: 5.4 m Width: 4.5 m Height: 4.2 m The anechoic chamber consists of a shielded enclosure constructed of rigid, steel-clad, wood core modular panels with steel framing. The chamber is treated with Rohde & Schwarz microwave absorber, utilizing both pyramidal and wedge shaped absorber. Lighting in the chamber is RF-filtered and consists of two (2) incandescent lamps mounted in recessed wav…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 1 of 68 Report Version: R00 FCC Radio Test Report FCC ID: A5MSM8866 Report No. : BTL-FCCP-1-2511T035 Equipment : Wireless Mouse Model Name : SM8866 Brand Name : Lenovo Applicant : Lenovo (Beijing) Limited Address : 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District,Beijing China Radio Function : Bluetooth Low Energy FCC Rule Part(s) : FCC CFR Title 47, Part 15, Subpart C (15.247) Measurement Procedure(s) : ANSI C63.10-2020 Date of Receipt : 2025/11/19 Date of Test : 2025/12/3 ~ 2025/12/11 Issued Date : 2025/12/18 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 2 of 68 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 3 of 68 Report Version: R00 CONTENTS REVISION HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 7 1.4 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 8 1.5 DUTY CYCLE 8 2 GENERAL INFORMATION 9 2.1 DESCRIPTION OF EUT 9 2.2 TEST MODES 11 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 2.4 SUPPORT UNITS 13 3 AC POWER LINE CONDUCTED EMISSIONS TEST 14 3.1 LIMIT 14 3.2 TEST PROCEDURE 14 3.3 DEVIATION FROM TEST STANDARD 15 3.4 TEST SETUP 15 3.5 TEST RESULT 15 4 RADIATED EMISSIONS TEST 16 4.1 LIMIT 16 4.2 TEST PROCEDURE 17 4.3 DEVIATION FROM TEST STANDARD 17 4.4 TEST SETUP 18 4.5 EUT OPERATING CONDITIONS 19 4.6 TEST RESULT – 9 KHZ TO 30 MHZ 19 4.7 TEST RESULT – 30 MHZ TO 1 GHZ 19 4.8 TEST RESULT – ABOVE 1 GHZ 19 5 BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES / LIMIT 20 5.2 TEST PROCEDURE 20 5.3 DEVIATION FROM STANDARD 20 5.4 TEST SETUP 20 5.5 EUT OPERATION CONDITIONS 20 5.6 TEST RESULTS 20 6 OUTPUT POWER TEST 21 6.1 APPLIED PROCEDURES / LIMIT 21 6.2 TEST PROCEDURE 21 6.3 DEVIATION FROM STANDARD 21 6.4 TEST SETUP 21 6.5 EUT OPERATION CONDITIONS 21 6.6 TEST RESULTS 21 7 POWER SPECTRAL DENSITY TEST 22 7.1 APPLIED PROCEDURES / LIMIT 22 7.2 TEST PROCEDURE 22 7.3 DEVIATION FROM STANDARD 22 7.4 TEST SETUP 22 7.5 EUT OPERATION CONDITIONS 22 Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 4 of 68 Report Version: R00 7.6 TEST RESULTS 22 8 ANTENNA CONDUCTED SPURIOUS EMISSION 23 8.1 APPLIED PROCEDURES / LIMIT 23 8.2 TEST PROCEDURE 23 8.3 DEVIATION FROM STANDARD 23 8.4 TEST SETUP 23 8.5 EUT OPERATION CONDITIONS 23 8.6 TEST RESULTS 23 9 LIST OF MEASURING EQUIPMENTS 24 10 EUT TEST PHOTO 26 11 EUT PHOTOS 26 APPENDIX A AC POWER LINE CONDUCTED EMISSIONS 27 APPENDIX B RADIATED EMISSIONS - 9 KHZ TO 30 MHZ 32 APPENDIX C RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 37 APPENDIX D RADIATED EMISSIONS - ABOVE 1 GHZ 40 APPENDIX E BANDWIDTH 59 APPENDIX F OUTPUT POWER 62 APPENDIX G POWER SPECTRAL DENSITY TEST 64 APPENDIX H ANTENNA CONDUCTED SPURIOUS EMISSION 66 Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 5 of 68 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-1-2511T035 R00 Original Report. 2025/12/18 Valid Report No.: BTL-FCCP-1-2511T035 Project No.: 2511T035 Page 6 of 68 Report Version: R00 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions APPENDIX A Pass ------ 15.205 15.209 15.247(d) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D Pass ------ 15.247(a)(2) Bandwidth APPENDIX E Pass ------ 15.247(b)(3) Output Power APPENDIX F Pass ------ 15.247(e) Power Spectral Density APPENDIX G Pass ------ 15.247(d) Antenna conducted Spurious Emission APPENDIX H Pass ------ 15.203 Antenna Requirement ------ Pass ------ Statement of Conformity The statement of conformity is based on the binary decision rule according to IEC Guide 115 and ILAC G8 "simple acceptance" principle. Wit…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 1 of 68 Report Version: R00 FCC Radio Test Report FCC ID: A5MSM8866 Report No. : BTL-FCCP-2-2511T035 Equipment : Wireless Mouse Model Name : SM8866 Brand Name : Lenovo Applicant : Lenovo (Beijing) Limited Address : 201-H2-6, Floor2, Building 2, No. 6 Shangdi West Road, Haidian District,Beijing China Radio Function : Short Range Device FCC Rule Part(s) : FCC CFR Title 47, Part 15, Subpart C (15.247) Measurement Procedure(s) : ANSI C63.10-2020 Date of Receipt : 2025/11/19 Date of Test : 2025/12/4 ~ 2025/12/11 Issued Date : 2025/12/18 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 2 of 68 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 3 of 68 Report Version: R00 CONTENTS REVISION HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 7 1.4 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 8 1.5 DUTY CYCLE 8 2 GENERAL INFORMATION 9 2.1 DESCRIPTION OF EUT 9 2.2 TEST MODES 11 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 2.4 SUPPORT UNITS 13 3 AC POWER LINE CONDUCTED EMISSIONS TEST 14 3.1 LIMIT 14 3.2 TEST PROCEDURE 14 3.3 DEVIATION FROM TEST STANDARD 15 3.4 TEST SETUP 15 3.5 TEST RESULT 15 4 RADIATED EMISSIONS TEST 16 4.1 LIMIT 16 4.2 TEST PROCEDURE 17 4.3 DEVIATION FROM TEST STANDARD 17 4.4 TEST SETUP 18 4.5 EUT OPERATING CONDITIONS 19 4.6 TEST RESULT – 9 KHZ TO 30 MHZ 19 4.7 TEST RESULT – 30 MHZ TO 1 GHZ 19 4.8 TEST RESULT – ABOVE 1 GHZ 19 5 BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES / LIMIT 20 5.2 TEST PROCEDURE 20 5.3 DEVIATION FROM STANDARD 20 5.4 TEST SETUP 20 5.5 EUT OPERATION CONDITIONS 20 5.6 TEST RESULTS 20 6 OUTPUT POWER TEST 21 6.1 APPLIED PROCEDURES / LIMIT 21 6.2 TEST PROCEDURE 21 6.3 DEVIATION FROM STANDARD 21 6.4 TEST SETUP 21 6.5 EUT OPERATION CONDITIONS 21 6.6 TEST RESULTS 21 7 POWER SPECTRAL DENSITY TEST 22 7.1 APPLIED PROCEDURES / LIMIT 22 7.2 TEST PROCEDURE 22 7.3 DEVIATION FROM STANDARD 22 7.4 TEST SETUP 22 7.5 EUT OPERATION CONDITIONS 22 Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 4 of 68 Report Version: R00 7.6 TEST RESULTS 22 8 ANTENNA CONDUCTED SPURIOUS EMISSION 23 8.1 APPLIED PROCEDURES / LIMIT 23 8.2 TEST PROCEDURE 23 8.3 DEVIATION FROM STANDARD 23 8.4 TEST SETUP 23 8.5 EUT OPERATION CONDITIONS 23 8.6 TEST RESULTS 23 9 LIST OF MEASURING EQUIPMENTS 24 10 EUT TEST PHOTO 26 11 EUT PHOTOS 26 APPENDIX A AC POWER LINE CONDUCTED EMISSIONS 27 APPENDIX B RADIATED EMISSIONS - 9 KHZ TO 30 MHZ 32 APPENDIX C RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 37 APPENDIX D RADIATED EMISSIONS - ABOVE 1 GHZ 40 APPENDIX E BANDWIDTH 59 APPENDIX F OUTPUT POWER 62 APPENDIX G POWER SPECTRAL DENSITY TEST 64 APPENDIX H ANTENNA CONDUCTED SPURIOUS EMISSION 66 Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 5 of 68 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-2-2511T035 R00 Original Report. 2025/12/18 Valid Report No.: BTL-FCCP-2-2511T035 Project No.: 2511T035 Page 6 of 68 Report Version: R00 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions APPENDIX A Pass ------ 15.205 15.209 15.247(d) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D Pass ------ 15.247(a)(2) Bandwidth APPENDIX E Pass ------ 15.247(b)(3) Output Power APPENDIX F Pass ------ 15.247(e) Power Spectral Density APPENDIX G Pass ------ 15.247(d) Antenna conducted Spurious Emission APPENDIX H Pass ------ 15.203 Antenna Requirement ------ Pass ------ Statement of Conformity The statement of conformity is based on the binary decision rule according to IEC Guide 115 and ILAC G8 "simple acceptance" principle. Witho…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yang Liu(Compliance Engineer)
[email protected]Fax: (86)10-55866630

Technical Contact

Lenovo (United States) IncorporatedBrian Killebrew
[email protected]Fax: 919-294-2716

8001 Development Drive · United States

Test Firm

BTL Inc.Jackie Chiu
[email protected]Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.80 mW
215C2.40 GHz - 2.48 GHz1.90 mW
315C2.40 GHz - 2.48 GHz1.90 mW
Confidentiality
Long Term
Grant Notes
Power Output is conducted. This is a portable device. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Lenovo (Beijing) Limited

A5MH50

TALIX H50 Noise Cancelling Over-ear Headphones

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
A5MWT1206

wegear T10 True Wireless Earbuds

Jul 30, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Lenovo Al Mouse - FCC ID A5M-M830 - Lenovo (Beijing) Limited
A5M-M830

Lenovo Al Mouse

Jul 16, 2026

Equipment Class

DTS - Digital Transmission System
Lenovo Pen Pro for Googlebook - FCC ID A5M-SE01 - Lenovo (Beijing) Limited
A5M-SE01

Lenovo Pen Pro for Googlebook

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System
wegear BLITZ B79 Wireless Mechanical Gaming Keyboard - FCC ID A5M-GK470 - Lenovo (Beijing) Limited
A5M-GK470

wegear BLITZ B79 Wireless Mechanical Gaming Keyboard

Jun 08, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter