ACQ-DCX3635MCable Set Top Box

ARRIS
Cable Set Top Box - FCC ID ACQ-DCX3635M - ARRIS
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jan 04, 2016
Application Purpose
Original Equipment
Date of Application
Oct 29, 2015
Equipment Note
Cable Set Top Box
Frequency Range
5745.00000000 - 5825.00000000
Company
ARRIS
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗
↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 IMPORTANT SAFETY INSTRUCTIONS • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with dry cloth. • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. • Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. • Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. • Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. • Only use attachments/accessories specified by the manufacturer. • Unplug this apparatus during lightning storms or when unused for long periods of time. • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as the power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. IMPORTANT SAFETY CONSIDERATIONS FOR ALL SET-TOPS • The mains plug is the main disconnect device. It shall remain readily accessible and operable. • The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. • WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. • WARNING: Batteries shall not be exposed to excessive heat such as sunshine, fire or the like. • See label on bottom of unit for additional markings. During Transportation to the Subscriber Home • Transport the cable terminal in its shipping box or an equally padded container. • Do not expose the terminal to rain or moisture. During Installation • Do not place the terminal in an enclosed area where the cooling vents are blocked or impede the flow of air through the ventilation openings. • Install the terminal so that its position does not interfere with its proper ventilation. For example, do not place the terminal on a bed, sofa, rug, or similar surface that could block the ventilation openings. • Install the terminal so that there is a minimum of two inches of space between surrounding surfaces and the top, left, and right sides of the terminal to ensure proper ventilation. • Install the terminal away from heat sources such as radiators, heat registers and stoves. Installation of the terminal near consumer electronics devices, such as stereo receiver/amplifiers and televisions, is permitted as long as the air surrounding the terminal does not exceed 40º C (104º F). • Place the terminal on a flat surface not prone to vibration or impact. • Do not place the terminal on top of another electronic device. • Do not install the terminal in an area where condensation occurs. • To prevent the temporary loss of guide data and cause a temporarily non- responding terminal, do not plug the AC power cord into a switched power outlet. ADDITIONAL SAFETY CONSIDERATIONS FOR DVR MODELS • To avoid shock and vibration damage to the internal hard drive, do not move the terminal while it is plugged in. • To allow the hard drive to spin down and park its heads, wait at least 10 seconds after disconnecting power before moving the terminal. • Install the terminal so that there is a minimum of 3 inches of space between surrounding surfaces and the back of the terminal to ensure proper ventilation. FCC Certification This product contains a radio transmitter and accordingly has been certified as compliant with 47 CFR Part 15 of the FCC Rules for intentional radiators. Products that contain a radio transmitter are labeled with FCC ID and the FCC logo. CAUTION: Exposure to Radio Frequency Radiation. To comply with the FCC RF exposure compliance requirements, the separation distance between the antenna and any person’s body (including hands, wrists, feet and ankles) must be at least 20 cm (8 inches). FCC COMPLIANCE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and set-top. • Connect the equipment into an outlet on a circuit different from that to which the set-top is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by ARRIS for compliance could void the user’s authority to operate the equipment. FCC DECLARATION OF CONFORMITY ARRIS Enterprises, Inc., 3871 Lakefield Drive, Suwanee, GA 30024, 1-866-36-AR…

Text truncated - open the document above for the full version.

Cover Letter(s)

TCBJ FORM-4 Issued by: TCB Administrator Revision 6 12/06/10 Long Term Confidentiality Request Letter September 30 th 2015 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR DCX3635 ACQ-DCX3635 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Block Diagrams, Schematics, Operational Descriptions, and Parts Listed required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of competition. Please contact me if there is any information you may need. Sincerely, Michael Welty

ID Label/Location Info

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 09AS

ID Label/Location Info

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 09AS

ID Label/Location Info

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 09AS

ID Label/Location Info

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 09AS

RF Exposure Info

§ 15.407(f) RF Exposure Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general population/uncontrolled” environment. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5150-5250 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Output Power = 25.36 dBm Antenna Gain = 9.6 dBi Power density is equal to 0.63 mW/cm^2. At a distance of 20 cm.

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. The limit for maximum RF exposure for 5GHz device is 1mW/cm^2 The formula for calculating RF exposure is given as S= Output Power = 23.93 dBm Antenna Gain = 9.9 dBi Power density is equal to 0.481mW/cm^2. At a distance of 20 cm.

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. Peak Conducted Power of 9.6dBi antenna= 19.81dBm =95.72mW 9.6dBi antenna gain in terms of linear value= 9.12 The limit for maximum RF exposure for 5GHz device is 1mW/cm^2 The formula for calculating RF exposure is given as S= P=95.72mW, G= 9.12 & R=20cm, then S comes out to be 0.174mW/cm^2 which was under the limit specified in 1.1310

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory October 23, 2015 ARRIS 101 Tournament Drive Horsham, PA 19044 Dear Mark Hageali, Enclosed is the EMC Wireless test report for compliance testing of the ARRIS, DCX3635 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407, Subpart E (UNII 1). Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\ARRIS\ EMC86201-FCC407 UNII 1 Rev. 2) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMC86201-FCC407 UNII 1 © 2015, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the ARRIS Model DCX3635 Tested under The FCC Certification Rules contained in Title 47 of the CFR 15.407 Subpart E MET Report: EMC86201-FCC407 UNII 1 Rev. 2 October 23, 2015 Prepared For: ARRIS 101 Tournament Drive Horsham, PA 19044 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 Electromagnetic Compatibility ARRIS Introduction DCX3635 CFR Title 47, Part 15.407 Subpart E MET Report: EMC86201-FCC407 UNII 1 Rev. 2 © 2015, MET Laboratories, Inc. Page ii of vii Electromagnetic Compatibility Criteria Test Report for the ARRIS Model DCX3635 Tested under The FCC Certification Rules contained in Title 47 of the CFR 15.407 Subpart E Surinder Singh, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules under normal use and maintenance. Asad Bajwa, Director, Electromagnetic Compatibility Lab Electromagnetic Compatibility ARRIS Introduction DCX3635 CFR Title 47, Part 15.407 Subpart E MET Report: EMC86201-FCC407 UNII 1 Rev. 2 © 2015, MET Laboratories, Inc. Page iii of vii Report Status Sheet Revision Report Date Reason for Revision  September 29, 2015 Initial Issue. 1 October 13, 2015 Corrected FCC ID. 2 October 23, 2015 Engineer Corrections. Electromagnetic Compatibility ARRIS Table of Contents DCX3635 CFR Title 47, Part 15.407 Subpart E MET Report: EMC86201-FCC407 UNII 1 Rev. 2 © 2015, MET Laboratories, Inc. Page i of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................4 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................5 E. Mode of Operation ..............................................................................................................................................5 F. Method of Monitoring EUT Operation ...............................................................................................................5 G. Modifications ......................................................................................................................................................5 a) Modifications to EUT .............................................................................................................. 5 b) Modifications to Test Standard ................................................................................................ 5 H. Disposition of EUT .........................................................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory October 29, 2015 ARRIS 101 Tournament Drive Horsham, PA 19044 Dear Mark Hageali, Enclosed is the EMC Wireless test report for compliance testing of the ARRIS, DCX3635 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\ARRIS\EMC86201-FCC407 UNII 2 Rev. 3) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMC85068-FCC407 UNII 2 © 2015, MET Laboratories, Inc. Page i of vi Electromagnetic Compatibility Criteria Test Report for the ARRIS DCX3635 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators MET Report: EMC86201-FCC407 UNII 2 Rev. 3 October 29, 2015 Prepared For: ARRIS 101 Tournament Drive Horsham, PA 19044 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility ARRIS Equipment Configuration DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 2 Rev. 3 © 2015, MET Laboratories, Inc. Page ii of xiii Electromagnetic Compatibility Criteria Test Report for the ARRIS DCX3635 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15, Subpart B for Unintentional Radiators and Title 47 of the CFR, Part 15.407 for Intentional Radiators Surinder Singh, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules under normal use and maintenance. Asad Bajwa, Director Electromagnetic Compatibility Lab Electromagnetic Compatibility ARRIS Equipment Configuration DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 2 Rev. 3 © 2015, MET Laboratories, Inc. Page iii of xiii Report Status Sheet Revision Report Date Reason for Revision  September 29, 2015 Initial Issue. 1 October 13, 2015 Corrected FCC ID. Electromagnetic Compatibility ARRIS Equipment Configuration DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 2 Rev. 3 © 2015, MET Laboratories, Inc. Page iv of xiii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................4 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................5 E. Mode of Operation ..............................................................................................................................................5 F. Method of Monitoring EUT Operation ...............................................................................................................5 G. Modifications ......................................................................................................................................................5 a) Modifications to EUT .................................................................................................................... 5 b) Modifications to Test Standard....................................................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory October 23, 2015 ARRIS 101 Tournament Drive Horsham, PA 19044 Dear Mark Hageali, Enclosed is the EMC Wireless test report for compliance testing of the ARRIS, DCX3635 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\ARRIS\EMC86201-FCC407 UNII 3 Rev. 2) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMC86201-FCC407 UNII 3 Rev. 2 © 2015, MET Laboratories, Inc. Page i of ix Electromagnetic Compatibility Criteria Test Report for the ARRIS DCX3635 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15.407 Subpart E for Intentional Radiators MET Report: EMC86201-FCC407 UNII 3 Rev. 2 October 23, 2015 Prepared For: ARRIS 101 Tournament Drive Horsham, PA 19044 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave Baltimore, MD 21230 Electromagnetic Compatibility ARRIS Cover Page DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 3 Rev. 2 © 2015, MET Laboratories, Inc. Page ii of ix Electromagnetic Compatibility Criteria Test Report for the ARRIS DCX3635 Tested under the Certification Rules contained in Title 47 of the CFR, Part 15.407 Subpart for Intentional Radiators Surinder Singh, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 15.407 of the FCC Rules under normal use and maintenance. Asad Bajwa, Director Electromagnetic Compatibility Lab Electromagnetic Compatibility ARRIS Report Status DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 3 Rev. 2 © 2015, MET Laboratories, Inc. Page iii of ix Report Status Sheet Revision Report Date Reason for Revision  September 29, 2015 Initial Issue. 1 October 13, 2015 Corrected FCC ID. 2 October 23, 2015 Engineer corrections. Electromagnetic Compatibility ARRIS Table of Contents DCX3635 CFR Title 47, Part 15E MET Report: EMC86201-FCC407 UNII 3 Rev. 2 © 2015, MET Laboratories, Inc. Page iv of ix Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................4 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................5 E. Mode of Operation ..............................................................................................................................................5 F. Method of Monitoring EUT Operation ...............................................................................................................5 G. Modifications ......................................................................................................................................................5 a) Modifications to EUT .................................................................................................................... 5 b) Modifications to Test Standard...................................................................................................... 5 H. Disposition of EUT .............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Photograph 1. Conducted Emissions, 15.207(a), Test Setup Photograph 2. Radiated Spurious Emissions, Test Setup

Contact Information

Applicant

Jorge Villarreal
[email protected]215-323-1697Fax: 215-323-0037

Technical Contact

ARRIS Group, Inc.Michael Welty
[email protected]215-323-2117

101 Tournament Drive · Horsham · United States

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz96.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device has 20, 40 and 80 MHz bandwidth modes.

Other Applications from ARRIS

WiFi extender - FCC ID ACQ-X5042V2 - ARRIS
ACQ-X5042V2

WiFi extender

Apr 12, 2023

Equipment Class

DTS - Digital Transmission System
Stream TV - FCC ID ACQ-STREAMTV - ARRIS
ACQ-STREAMTV

Stream TV

May 16, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
ACQ-VIP7802

WiFi Set Top Box

May 05, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
WiFi extender - FCC ID ACQ-X5042 - ARRIS
ACQ-X5042

WiFi extender

Jun 07, 2020

Equipment Class

DTS - Digital Transmission System
Cable Set Top Box - FCC ID ACQ-DCX3635 - ARRIS
ACQ-DCX3635

Cable Set Top Box

Oct 21, 2015

Equipment Class

DTS - Digital Transmission System