FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ritron Inc/
  3. AIERIT09-150

AIERIT09-150Voice Notification Radio Transmitter

Ritron Inc
Voice Notification Radio Transmitter - FCC ID AIERIT09-150 - Ritron Inc
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Apr 07, 1999
Application Purpose
Original Equipment
Date of Application
Jan 11, 1999
Equipment Note
Voice Notification Radio Transmitter
Frequency Range
150.00000000 - 165.00000000
Company
Ritron Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Schematics

↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

rtc9212b.pm5 Ritron Publication RQT-UM1 14500006 Revision B 02-12-1999 Copyright© 1999 RITRON, INC. — ALL RIGHTS RESERVED RITRON®,PATRIOT®,JOBCOM®&Quiet Call® are registered trademarks of RITRON,INC. Quick Talk TM is a trademark of RITRON, INC. P.O. Box 1998, Carmel, IN 46032-1998 • 505 W. Carmel Dr., Carmel, IN 46032 • USA PH: 317-846-1201; 1-800-USA-1-USA (1-800-872-1872) • FAX: 317-846-4978 Web: www.ritron.com • E-mail: [email protected] Quick Talk Voice Notification Radio Transmitter Basic Owner's Manual - CONSTRUCTION - FACTORIES - WAREHOUSES - FARMS - UTILITIES - AIRPORTS - STORES - SECURITY - LAW ENFORCEMENT - SHIPPING - APARTMENTS - SPORTS - HOTELS - RESTAURANTS - SCHOOLS - TRANSPORTATION rtc9212b.pm5 When using this unit, follow these basic safety instruc- tions to reduce the risk of fire, electric shock or personal injury. 1.Read and follow all instructions. 2.Disconnect the unit before cleaning. Do not use liquid or aerosol cleaners. 3.Use only approved power sources for the unit. 4.During thunderstorms, avoid contact with this unit and any external antenna system or wiring. 5.The Quick Talk switch and external power terminals are connected internally to the antenna connector. If the Quick Talk switch or power supply terminals are connected to a high voltage a hazardous condition may exist in that contact with the antenna may prove injurious or even fatal. 6.In general, the switches you connect to the Quick Talk should be independent dry contact switches and not a part of any other "live" electrical circuit 7.If you are unsure whether your installation will be safe, contact an experienced electrician or electronics technician. TABLE OF CONTENTS DESCRIPTIONPAGE WHAT THIS MANUAL COVERSii WARNINGS AND CAUTIONSii ACCESSORIES AND OPTIONSii INTRODUCTION1 General1 Model Identification1 FEATURES1 Basic Features1 Advanced Features1 CONTROLS & CONNECTORS2 PROGRAMMING3 Frequently Asked Questions3 Testing Your Programming Telephone3 Transmitter Frequency4 Quiet Call Coded Squelch Codes5 Digital Quiet Call Squelch Codes6 Testing Your Switch7 Recording Voice Messages8 Playing Back Voice Messages8 Programming Voice Phrase Repetitions9 Programming a Transmission Schedule9 Limiting the Number of Transmissions10 Resetting the unit to Factory Defaults10 INSTALLATION11 CARE AND MAINTENANCE11 Low Battery Alert Message11 Battery Replacement11 F.C.C. LICENSING12 WARRANTY12 ACCESSORIES FOR QUICK TALK These replacement and optional items are available from Ritron and its authorized dealers. ItemDescription AFB-1545Standard 19' Flexible Whip Antenna ABD-1545High Performance External Antenna RAC-02BNCoaxial Cable for External Antenna, 20 ft. RQT-UM2Advanced Features Applications Manual This manual (Ritron Item: RQT-UM1) covers basic opera- tion of the Quick Talk Voice Notification Radio Transmitter. For the majority of applications this is all you will need. There are many more complex features of the Quick Talk that are explained in the Advanced Features Manual (Ritron Item: RQT-UM2). In addition, the following application notes are available via fax by calling Ritron at 317-846-1201, or on the Ritron Website at "http://www.ritron.com". App.Note #Description of Application Bulletin RQT-AN01Using 0-5 V and 4-20 mA Analog Inputs RQT-AN02Using Terminated Alarm Loops RQT-AN03Greater Range with Optional Antennas RQT-AN03Greater Ranges using Repeaters RQT-AN04Vehicle Detectors for the Quick Talk RQT-AN05Solar Power Panels for Quick Talk RQT-AN06Ritron Custom Engineering Services RQT-AN07Interfacing to High Power Radios RQT-AN08Quick Talk Agricultural Applications RQT-AN09Quick Talk Industrial Applications RQT-AN10Quick Talk Retail Business Applications RQT-AN11Security and Alarm Applications RQT-AN12Home and Sports Application Page ii WHAT THIS MANUAL COVERS - - - - - - - WARNING - - - - - - - IMPORTANT SAFETY INFORMATION Page 1For assistance, telephone RITRON at 1-800-872-1872 or go to "http://www.ritron.com". qtm9212a.pm5 ABOUT THE QUICK TALK VOICE NOTIFICATION TRANSMITTER QUICK TALK FEATURES GENERAL INFORMATION The Quick Talk is a radio transmitter that reports changes in the status of switches by transmitting user-recorded voice messages to two-way mobile or portable radios. Quick Talk transmits your voice message when the switch change occurs and at intervals you select. Because you provide and connect the switches to your Quick Talk units, they can report changes due to intrusion, tamper, equipment malfunction, liquid level, machinery, pressure, temperature, power, smoke or leakage. The Quick Talk is easily programmed to transmit on your existing or new radio frequency and also encodes the most popular sub-audible coded squelch formats such as Quiet Call® or Digital Quiet Call TM . This enables all of your personnel with JOBCOM, PATRIOT or equivalent two-way radios to hear the voice messages instantly, and to be alerted to the current condition of each monitored location or device. Quick Talk is housed in a weather-resistant enclosure so that it can be installed in a wide variety of indoor and outdoor locations. You don't have to supply AC line power to the Quick Talk because its six internal AA Alkaline batteries will power the unit for about a year. QUICK TALK MODELS AND FREQUENCIES There are two separate Quick Talk models, one for each of the most popular professional radio communications bands. The model number appears on a label on the front of the case and a second label is placed inside the case. MODELBANDFREQUENCY RANGE RQT-150VHF-FM150 to 165 MHz RQT-450UHF-FM450 to 470 MHz Ritron manufactures mobile, portable and base station two- way radios and repeaters for use with Quick Talk, and pioneered the use of Color Dots on radios to identify frequencies. The factory-programmed, default frequencies for Quick Talk are Blue Dot (154.570 MHz) for VHF units, and Blue Star (467.925 MHz) for UHF units. The instruc- tions on page 4 describe how easy it is for the owner to change the Quick Talk transmit fr…

Text truncated - open the document above for the full version.

Attestation Statements

From:RITRON, INC. 505 West Carmel Drive Carmel, IN 46032 Date:January 10, 1999 To: Federal Communications Commission Re:Attestation for Testing and Compliance FCC ID: AIERIT09-150 This equipment has been tested in accordance with the requirements contained in the appropriate Commission regulations. To the best of my knowledge, these tests were performed using measurement procedures consistent with industry or Commission standards and demonstrate that the equipment complies with the appropriate standards. Each unit manufactured, imported or marketed as defined in the Commission’s regulations, will conform to the samples tested within the variations that can be expected due to quantity production and testing on statistical basis. I further certify that the necessary measurements were made at the facilities of Ritron, Inc. either by myself or a qualified individual under my direct supervision. Steven Paul Henke Vice President and Chief Engineer

Block Diagram

FCC ID: AIERIT09-150 RQT – 150 Transmitter Block Diagram +5V Regulator (IC302) LATCH IN CLK IN DATA IN TX MOD Synthesizer (IC301) Reference Oscillator w/Modulator (16.000 MHz) TX Power Supply Switching and Regulation (Q312, 313, 314, 315) +V SW STROBE TX_ENABLE +V_Strobe +15V Voltage Boost (Q301) Voltage Controlled Oscillator / Buffer (Q307, 308) Modulation Balance (R310) RF Final Stage (Q401) +5VTxPA +5VTxPA +5V_TX RF Feedback Low-Pass Filter +V BATT Charge Pump (Q303 & 304) Loop Filter Control Voltage RF Driver Stage (Q311) VCO Buffer Amplifier (Q309) GND +15V Ref. Modulation VCO Modulation Interface Connector to Control Board DOWN UP Pulses

External Photos

F.C.C. Equipment Authorization Exhibit RITRON, INC. FCC ID: AIERIT09-150 Page 1 of 1 External photograph showing placement of FCC ID label.

ID Label/Location Info

This drawing is provided to the label vendor. It specifies the construction and information present on the FCC ID label.Two labels are attached to each RQT. One label is placed on the outside of the unit in the lower right hand corner of the fron t cover. This is shown in the external photograph provided as a separate exhibit.A second label is placed on the inside of the front cover as shown in the internal photograph provided as a separate exhibit.

Internal Photos

F.C.C. Equipment Authorization Exhibit RITRON, INC. FCC ID: AIERIT09-150 Page 1 of 3 Internal Photographs F.C.C. Equipment Authorization Exhibit RITRON, INC. FCC ID: AIERIT09-150 Page 2 of 3 F.C.C. Equipment Authorization Exhibit RITRON, INC. FCC ID: AIERIT09-150 Page 3 of 3

Operational Description

From: RITRON, INC. 505 West Carmel Drive Carmel, IN 46032 Date: January 5, 1999 To:Federal Communications Commission Re:Statement Concerning RF Exposure FCC ID: AIERIT10-450 Per the FCC Rules and Regulations as described in the Commission’s OET Bulletin 65 this device is categorically excluded from routine RF evaluation because it is a Part 90, low power, intermittently activated transmitter. Steven Paul Henke Vice President & Chief Engineer

Parts List/Tune Up Info

From: RITRON, INC. 505 West Carmel Drive Carmel, IN 46032 Date: January 5, 1999 To:Federal Communications Commission Re:Statement Concerning RF Exposure FCC ID: AIERIT10-450 Per the FCC Rules and Regulations as described in the Commission’s OET Bulletin 65 this device is categorically excluded from routine RF evaluation because it is a Part 90, low power, intermittently activated transmitter. Steven Paul Henke Vice President & Chief Engineer

RF Exposure Info

From: RITRON, INC. 505 West Carmel Drive Carmel, IN 46032 Date: January 5, 1999 To:Federal Communications Commission Re:Statement Concerning RF Exposure FCC ID: AIERIT10-450 Per the FCC Rules and Regulations as described in the Commission’s OET Bulletin 65 this device is categorically excluded from routine RF evaluation because it is a Part 90, low power, intermittently activated transmitter. Steven Paul Henke Vice President & Chief Engineer

Test Report

F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 1 of 29 Exhibit Type:Test Report Date:January 5, 1999 The following exhibits are contained in this file. Other exhibits required were electronically filed as separate exhibits. This file makes references to information contained in these separate exhibits. This includes but is not limited to schematics, drawings and photographs. Description of Exhibit F.C.C. Rule(s) - Statement of Certifying Engineer2.947 Manufacturer’s Statement2.983 (a) (b) (c) List of Test Equipment Used2.947 (d) Description of Measurement Facility2.948 Statement Certifying Spectrum Efficiency 90.203 (j) (3) Radio Frequency Power Output2.985 Transmitter Modulator Response2.987 (a), (b) Speech Amplifier Low Pass Filter Response2.987(a) Percent of Modulation vs. Modulation Input Voltage2.987(b) Occupied Bandwidth, Emission Masks2.989 (c), 90.210 (d), 90.211 (a) Spurious Emissions at Antenna Terminals2.991 Field Strength of Spurious Emissions2.993 (b) Frequency Stability vs. Temperature2.995 (a), 90.213 (a) (7) Frequency Stability vs. Input Voltage2.995 (d) F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 2 of 29 EXHIBIT TYPE:Statement of Certifying Engineer FCC PART:2.947 DATE:January 5, 1998 I, Steven Paul Henke, am now and have been for the past 20 years the Vice President and Chief Engineer of RITRON, INC.. I hereby certify that all the measurements and data herein were taken by me, or under my direct supervision and that they were obtained using sound and professionally accepted engineering principles, and that they accurately reflect the performance and characteristics of the unit tested. Further I attest that manufacturing controls exist such that this data is representative of units which will be manufactured by Ritron. Signed: Steven Paul Henke Vice President and Chief Engineer F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 3 of 29 EXHIBIT TYPE:List of Test Equipment Used to Conduct Measurements FCC PART:2.947 (d) DATE:November 10, 1998 The measurements taken for this application were obtained using one or more of the following pieces of equipment. ITEM MANUFACTURER MODEL NO.SERIAL NO. DC Power SupplyAstron VS-20M 9406023 MultimeterBeckman Industrial441050710069 MultimeterBK Precision2704A234-008455 RF Power MeterHewlett Packard435B2441A10170 RF Power Sensor*Hewlett Packard8482B2349A01936 RF Load, Calibrated*Hewlett Packard8482B2349A01936 * Traceable Calibrated Source of matching serial numbers. WattmeterTelewave448172 RF Test SetHewlett Packard 8920AR# 01498 Spectrum AnalyzerHewlett Packard8559A2010A 06979 Spectrum AnalyzerHewlett PackardHP8560E 01540 Digital Storage ScopeFluke/PhillipsPM3335DM630034 PlotterHewlett Packard7585B2503A05509 Temperature ChamberDelta Design3900 CL0-52-R PyrometerOmega 7035-J-2257504 F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 4 of 29 EXHIBIT TYPE:Description of Measurement Facility FCC PART:2.948 DATE:November 10, 1998 The Field Strength measurements filed with this application were made on a site certified by RITRON, INC.. Data pertaining to this site is on file with the FCC and is current. This site is used on a continuing basis exclusively by RITRON, INC. and is utilized only for RF Field Strength Measurements of equipment designed and manufactured by RITRON, INC.. It is not used for measurements by or for any other party on a contract basis or otherwise. All other measurements were taken at Ritron’s Engineering Laboratory in Carmel, Indiana. F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 5 of 29 EXHIBIT TYPE:Radio Frequency Power Output FCC PART:2.985 DATE:December 14, 1998 PROCEDURE: An RQT-150 was aligned for transmitter operation on 154.540 MHz. (Fo) per the tune-up procedure outlined in the preliminary manual. The output of a variable DC power supply was applied to the external DC power terminals of the unit. The RQT-150 antenna connector was connected to the input of the HP Power Meter. This device provides a single 50 Ohm resistively loaded input port for all measurements. The voltages across the resistor in series with the final RF power transistor were measured and Ohm’s Law was used to determine the collector current. The DC power supply voltage applied to the unit was varied from 6 to 15 Volts DC. The measured transmitter output power remained constant across this range of input voltages. This is attributable to the fact that supply voltages to the transmitter are regulated to a fixed voltage regardless of the applied power supply voltage. RQT-150, 154.54 MHz, 15 Ohm Collector Resistor External RegulatedCollectorCollectorInputRF Output VoltageVoltageVoltageCurrentPowerPower Efficiency (Volts) (Volts)(Volts)(Amperes)(Watts)(Watts)(%) 6.04.93.60.0870.3120.11838% 9.04.93.60.0870.3120.11838% 12.04.93.60.0870.3120.11838% 15.04.93.60.0870.3120.11838% Certifying Engineer:Steve Henke Date:December 14,1998 F.C.C. Equipment Authorization Application Exhibit. RITRON, INC. FCC ID: AIERIT09-150 Page 6 of 29 EXHIBIT TYPE:Modulator Frequency Response FCC PART:2.987 (a), (b) DATE:November 20, 1998 PROCEDURE: The RQT-150 was aligned for transmitter operation on 154.540 MHz. (Fo) per the tune-up procedure contained in the preliminary manual. The modulation input to the transmitter was isolated by breaking the TX MOD line between the RQT Control and Transmitter boards. The HP Test Set’s Audio Generator output was connected to the Transmitter Board’s TX MOD. The frequency response of the modulator was determined to be flat within +/-1.5 from 10 Hz to 27,000 Hz. The slight variation is response is at a low frequency and is due to the two point synthesizer reference and VCO modulation method. The following pages show the results in tabular and graphical form. Certifying Engineer:Steve Henke Date:November 20, 1998 F.C.C. Equipme…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Sam L. Dulaney(Chief Engineer)
[email protected]317 846-1201Fax: 317 846-4978

Technical Contact

Ritron IncSteven P Henke
[email protected]317-846-1201

505 West Carmel Drive · Carmel, Indiana · United States

Non-Technical Contact

Ritron IncSteven P Henke
[email protected]317-846-1201

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
290.217(b)150 MHz - 165 MHz120.00 mW16K0F3E5 ppm

Other Applications from Ritron Inc

VHF Transceiver - FCC ID AIERIT53-16006 - Ritron Inc
AIERIT53-16006

VHF Transceiver

Jan 04, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
VHF Modem Transceiver - FCC ID AIERIT39-26006 - Ritron Inc
AIERIT39-26006

VHF Modem Transceiver

Aug 26, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
UHF Transceiver - FCC ID AIERIT51-46530 - Ritron Inc
AIERIT51-46530

UHF Transceiver

Jul 25, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
UHF DMR Digital / Analog 2-Way Desktop Radio - FCC ID AIERIT50-477DMR - Ritron Inc
AIERIT50-477DMR

UHF DMR Digital / Analog 2-Way Desktop Radio

Feb 01, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
VHF Transceiver - FCC ID AIERIT51-16006 - Ritron Inc
AIERIT51-16006

VHF Transceiver

Jan 19, 2021

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter