
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MultiConnect ® rCell100 SeriesRouterUserGuide MULTICONNECT® RCELL100 SERIESROUTERUSERGUIDE MultiConnect ® rCell100 SeriesRouterUserGuide Model:MTR-EV3 Part Number:S000582Version:1.0.4 Copyright This publicationmay not be reproduced,in wholeor in part,withoutthe specificand expresspriorwrittenpermissionsignedby an executiveofficerof Multi-TechSystems,Inc. All rightsreserved.Copyright© 2014by Multi-TechSystems,Inc. Multi-TechSystems,Inc. makesno representationsor warranties,whetherexpress,impliedor by estoppels,withrespectto the content,information, materialand recommendationshereinand specificallydisclaimsany impliedwarrantiesof merchantability,fitnessfor any particularpurposeand non- infringement. Multi-TechSystems,Inc. reservesthe rightto revisethis publicationand to makechangesfromtimeto timein the contenthereofwithoutobligationof Multi-TechSystems,Inc. to notifyany personor organizationof suchrevisionsor changes. LegalNotices The Multi-Techproductsare not designed,manufacturedor intendedfor use, and shouldnot be used,or sold or re-soldfor use, in connectionwith applicationsrequiringfail-safeperformanceor in applicationswherethe failureof the productswouldreasonablybe expectedto resultin personalinjuryor death,significantpropertydamage,or seriousphysicalor environmentaldamage.Examplesof suchuse includelife supportmachinesor otherlife preservingmedicaldevicesor systems,air trafficcontrolor aircraftnavigationor communicationssystems,controlequipmentfor nuclearfacilities,or missile,nuclear,biologicalor chemicalweaponsor othermilitaryapplications(“RestrictedApplications”). Use of the productsin suchRestricted Applicationsis at the user’s sole risk and liability. MULTI-TECHDOESNOTWARRANTTHATTHE TRANSMISSIONOF DATABY A PRODUCTOVERA CELLULARCOMMUNICATIONSNETWORKWILLBE UNINTERRUPTED,TIMELY,SECUREOR ERRORFREE,NORDOESMULTI-TECHWARRANTANY CONNECTIONOR ACCESSIBILITYTO ANY CELLULAR COMMUNICATIONSNETWORK.MULTI-TECHWILLHAVENO LIABILITYFOR ANY LOSSES,DAMAGES,OBLIGATIONS,PENALTIES,DEFICIENCIES,LIABILITIES, COSTSOR EXPENSES(INCLUDINGWITHOUTLIMITATIONREASONABLEATTORNEYSFEES)RELATEDTO TEMPORARYINABILITYTO ACCESSA CELLULAR COMMUNICATIONSNETWORKUSINGTHE PRODUCTS. ContactingMulti-Tech KnowledgeBase The KnowledgeBaseprovidesimmediateaccessto supportinformationand resolutionsfor all Multi-Techproducts.Visithttp://www.multitech.com/kb.go. SupportPortal To createan accountand submita supportcasedirectlyto our technicalsupportteam,visit:https://support.multitech.com. Support BusinessHours:M-F,8amto 5pmCT CountryBy EmailBy Phone Europe,MiddleEast,Africa:[email protected]+(44)118 959 7774 U.S.,Canada,all others:[email protected](800)972-2439or (763)717-5863 Warranty To readthe warrantystatementfor yourproduct,visit www.multitech.com/warranty.go. For otherwarrantyoptions,visit www.multitech.com/es.go. WorldHeadquarters Multi-TechSystems,Inc. 2205WoodaleDrive,MoundsView,MN 55112 Phone:(800)328-9717or (763)785-3500 Fax (763)785-9874 2MultiConnect ® rCell100 SeriesRouterUserGuide CONTENTS Contents ProductOverview....................................................................................................................................................5 AboutMultiConnectrCell100 SeriesRouter................................................................................................................5 Documentation...........................................................................................................................................................5 Descriptionsof LEDs......................................................................................................................................................6 EthernetLED Descriptions...........................................................................................................................................6 Side Panels....................................................................................................................................................................7 Specifications................................................................................................................................................................8 Dimensions..................................................................................................................................................................10 PowerDrawMTR-EV3.................................................................................................................................................11 SafetyWarnings.....................................................................................................................................................12 LithiumBattery...........................................................................................................................................................12 EthernetPorts.............................................................................................................................................................12 RadioFrequency(RF) Safety.......................................................................................................................................12 InterferencewithPacemakersand OtherMedicalDevices......................................................................................12 Potentialinterference...............................................................................................................................................12 Precautionsfor pacemakerwearers........................................................................................................................13 Antenna.......................................................................................................................................................................13 ImportantSafetyInstructions.....................................................................................................................…
Text truncated - open the document above for the full version.
Multitech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 May 19, 2014 Subject: 47 CFR Section 2.1033(b)(11) To Whom It May Concern: The MTR-EV3-B10 and MTR-EV3-B09 devices do not operate within the 59.0– 64.0 GHz range. Per 47 CFR Section 2.1033(b)(11) we are therefore not required to provided exhibits demonstrating compliance with the provisions of § 15.255 (g) and (i). Sincerely, Marvin Sundeen Director of Quality Control
Multi-Tech Systems, Inc., 2205 Woodale Drive, Mounds View, MN 55112 Receiver Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 Subject: Request for Permanent Confidentiality FCC ID: AU792U13A16855 5-19-2014 To Whom It May Concern: In accordance with §0.457(d) and §0.459 of CFR 47, Multi-Tech Systems, Inc. requests permanent confidentiality for the following items 1. Block Diagram 2. Schematic Diagram 3. Part List 4. Operational Description These items contain detailed system and equipment description and related information about the product which Multi-Tech Systems, Inc. considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Multi-Tech Systems, Inc. also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. Best Regards, Marvin Sundeen Director of Quality Control Multi-Tech Systems, Inc
Multi-Tech Systems, Inc., 2205 Woodale Drive, Mounds View, MN 55112 Receiver Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 Subject: Request for Short Term Confidentiality FCC ID: AU792U13A16855 5-19-2014 To Whom It May Concern: In accordance with §0.457(d) and §0.459 of CFR 47, Multi-Tech Systems, Inc. requests short term confidentiality for the following items 1. External Photographs 2. Internal Photographs 3. User Manual 4. Test Set-Up Photographs. Until the product will be publically announced short term confidentiality release date: 180 days from the grant date These items contain detailed system and equipment description and related information about the product which Multi-Tech Systems, Inc. considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Multi-Tech Systems, Inc. also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. Best Regards, Marvin Sundeen Director of Quality Control Multi-Tech Systems, Inc
Multi-Tech Systems, Inc., 2205 Woodale Drive, Mounds View, MN 55112 5/19/2014 Federal Communications Commission 445 12th Street SW Washington, DC 20554 Subject: Limited Agency Agreement Re: We, Multi-Tech Systems, Inc hereby authorized Intertek Testing Services to act as our agent for the purpose of preparing application for FCC ID number AU792U13A16855 under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is (5/19/2014). The limited agency agreement expires on 8/9/2014 unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Best Regards, Marvin Sundeen Director of Quality Control Multi-Tech Systems, Inc
Label and location info
Label and location info
731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com MPE Calculation § 1.1310: The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter. Part 1.1310 Limits for Maximum Permissible Exposure (MPE) 1.1 Test Procedure An MPE evaluation for was performed in order to show that the device was compliant with §2.1091. The maximum power density was calculated for each transmitter at a separation distance of 20cm. For each transmitter the maximum RF exposure at a 20 cm distance using the formula: 10/)( 10 dBmowerConductedP mW PowerConducted= 2 )20(4 . cm mW GainAntPowerConducted tyPowerDensi × × = π 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com 1.2 Results: The device contains Cellular, Bluetooth, and 802.11 transmitters. The Cellular radio can which can transmit simultaneously. The following calculations show that the total power density from each transmitter at 20cm is less than the limit for general population / un-controlled exposure. With the worst case Cellular, 802.11, and Bluetooth radios transmitting simultaneously, the MPE calculations are less than the applicable limit. The device meets the RF exposure limit at a 20cm separation distance as required by part 2.1091 of the FCC rules with all modules transmitting simultaneously 1 . The total sum of the ratio of the power densities to the corresponding limit for all radios capable of transmitting simultaneously was computed as follows: Total = (CDMA Cell Band Power Density / Limit Cell Band) + (802.11 Power Density / Limit 802.11) + (Bluetooth Power Density / Limit Bluetooth) Total = (0.12 / 0.54) + (0.09 / 1) + (0.000003 / 1) = 0.312 Compliance is shown by the sum of the radio of the power densities for all radios that can transmit simultaneously being less than 1. 1 The cellular radio is only capable of transmitting in one mode at a time. 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com Individual Radio Test Results: CDMA Cell Band Transmitter: • Maximum Cell Band Conducted Output Power = 300mW • Maximum Cell Band Antenna Gain = 2.0dBi Power Density = (300*2mW x 2.0dBi) / 5025.6 Power Density = 0.12mW/cm2 Limit at 824MHz = 0.54mW/cm 2 CDMA PCS Band Transmitter: • Maximum PCS Conducted Output Power = 274mW • Maximum PCS Antenna Gain = 2.0dBi Power Density = (274mW x 2.0dBi) / 5025.6 Power Density = 0.11mW/cm2 Limit at 1.8GHz = 1mW/cm 2 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com 802.11 Transmitter • Maximum 802.11 Conducted Output Power = 264mW • Maximum 802.11 Antenna Gain = 1.8dBi Power Density = (264mW x 1.8dBi) / 5025.6 Power Density = 0.09mW/cm2 Limit at 2.4GHz = 1mW/cm 2 Bluetooth Transmitter • Maximum Bluetooth Conducted Output Power = 0.0084mW • Maximum Bluetooth Antenna Gain = 1.8dBi Power Density = (0.0084mW x 1.8dBi) / 5025.6 Power Density = 0.000003mW/cm 2 Limit at 2.4GHz = 1mW/cm 2
Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 2 of 55 TABLE OF CONTENTS 1. Scope 4 2. Introduction (Site Description) 5 2.1 Test facility 5 2.2 Accreditation and listing 6 3. Test Conditions & EUT Information 7 3.1 Operating During Test 7 3.2 Environmental Conditions 7 3.3 Description of EUT 7 4. Measuring Instrument Calibration 8 5. Summary of Test Results 9 6. Recommendation / Conclusion 9 7. Description of Test 10 7.1 Effective Radiated Power / Equivalent Isotropic Radiated Power 10 7.2 Radiated Spurious & Harmonic Emission 11 7.3 Conducted Output Power 12 7.4 Conducted Spurious Emission 13 7.5 Frequency Stability / Temperature Variation 15 7.6 Conducted Output Power 16 8. Test Data 17 8.1 Conducted Output Power 17 8.2 Effective Radiated Power (ERP) 19 8.3 Equivalent Isotropic Radiated Power (EIRP) 20 8.4 Occupied Bandwidth / 26 dB Emission Bandwidth 21 8.5 Radiated Spurious & Harmonic Emission (Cellular) 22 8.6 Radiated Spurious & Harmonic Emission (PCS) 24 8.7 Frequency Stability / Temperature Variation (Cellular) 26 8.8 Frequency Stability / Temperature Variation (PCS) 28 8.9 Receiver Spurious Emissions 30 Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 3 of 55 9. Accuracy of Measurement 31 10. Test Plots (Cellular) 33 11. Test Plots (PCS) 40 12. Test Equipment List 47 Appendix A: Labelling Requirement 48 Appendix B: Photographs of Test Set-up 49 Appendix C: EUT Photographs 50 Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 4 of 55 1. Scope Measurement and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission under FCC Part 2 & Part 22 & 24 and Industrie Canada under RSS-Gen & 132 & 133. Responsible Party : Contact Person : Manufacturer : Telit Communications S.p.A. Brian Tucker Tel No. : +919 439 7977 Telit Communications S.p.A. Viale Stazione di Prosecco 5/B, 34010 Sgonico, Trieste, Italy z FCC ID: RI7DE910-DUAL z IC 5131A-DE910DUAL z Model: DE910-DUAL z Brand Name: Telit z EUT Type: DUAL BAND CDMA/GPS Module z Classification: Licensed Potable Transmitter(PCB) z Applied Standard: FCC 47 CFR Part & 2, 22, 24 RSS-Gen, 132,133 z Test Procedure(s): ANSI C63.4 (2003) z Dates of Test: November 22, 2011 ~ November 30, 2011 z Place of Tests: Nemko Korea Co., Ltd. Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 5 of 55 2. Introduction (Site Description) 2.1 Test facility The measurement procedure described in American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C63.4-2003) was used in determining radiated and conducted emissions emanating from Telit Communications S.p.A. FCC ID : RI7DE910-DUAL and IC: 5131A-DE910DUAL These measurement tests were conducted at Nemko Korea Co., Ltd. The site address is 300-2, Osan-Ri, Mohyeon-Myeon, Cheoin-Gu, Yongin-Si, Gyeonggi-Do, KOREA The area of Nemko Korea Corporation Ltd. Test site is located in a mountain area at 80 kilometers (48 miles) southeast and Incheon International Airport (Incheon Airport), 30 kilometers (18miles) south-southeast from central Seoul. It is located in the valley surrounded by mountains in all directions where ambient radio signal conditions are quiet and a favorable area to measure the radio frequency interference on open field test site for the computing and ISM devices manufactures. The detailed description of the measurement facility was found to be in compliance with the requirements of §2.948 according to ANSI C63.4 2003. Fig. 1. The map above shows the Seoul in Korea vicinity area. The map also shows Nemko Korea Corporation Ltd. and Incheon Airport. Nemko Korea Co., Ltd. 300-2,Osan-Ri,Mohyeon-Myeon, Cheoin-Gu, Yongin-Si, Gyunggi-Do, KOREA 449-852 Tel) +82-31-322-1700 Fax) +82-31-322-2332 Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 6 of 55 2.2 Accreditation and listing Accreditation type Accreditation number FCC part 15/18 Filing site Registration No. 97992 CAB Accreditation for DOC Designation No. KR0026 KOLAS Accredited Lab. (Korea Laboratory Accreditation Scheme) Registration No. 155 Canada IC Registered site Site No. 2040E-1 VCCI registration site(RE/CE/Telecom CE) Member No. 2118 EMC CBTL - KCC(RRL)Designated Lab. Registration No. KR0026 SASO registered Lab and Certification Body Registration No. 2008-15 Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 7 of 55 3. Test Conditions & EUT Information 3.1 Operating During Test The EUT was tested at the lowest channel, middle channel and the highest channel with maximum RF power and all data were recorded in the report. 3.2 Environmental Conditions Temperature 21°C ~ 26°C Relative Humidity 35% ~ 60% 3.3 Description of EUT Frequency Band Tx 824.70 MHz ~ 848.31 MHz 1851.25 MHz ~ 1908.75 MHz Rx 869.70 MHz ~ 893.31 MHz 1931.25 MHz ~ 1988.75 MHz Output Power (Conducted power) Cellular CDMA : 0.298 W(24.74 dBm) PCS CDMA : 0.274 W(24.37 dBm) Emission Designator 1M29F9W Antenna Type Magnet Mount Antennas Antenna Gain 5.12 dBi for Cellular, 6.12 dBi for PCS Dimensions 28.2 mm(W) x 28.2 mm(D) x 2.5 mm(H) Weight Approx. 4.7 g Operating Temperature -30°C ~ +85 °C Test Report No.: NK-11-R-299 FCC and IC Certification Telit Communications S.p.A. FCC ID: RI7DE910-DUAL / IC: 5131A-DE910DUAL Page 8 of 55 4. Measuring Instrument Calibration All measurements were made with instruments calibrated according to the r…
Text truncated - open the document above for the full version.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. EMC Report for MultiTech Systems, Inc. on the rCell – Intelligent Wireless Router Page 1 of 12 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com CDMA TEST REPORT Report Number: 101549076LEX-004 Project Number: G101549076 Report Issue Date: 6/3/2014 Product Name: rCell – Intelligent Wireless Router FCCID: AU792U13A16855 Standards: FCC Part 22 Subpart H FCC Part 24 Subpart E Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Drive Lexington, KY 40510 MultiTech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 Report prepared by Report reviewed by Toby Carrier, Technician Bryan Taylor, Team Leader Intertek Report Number: 101549076LEX-004 Issued: 6/3/2014 EMC Report for MultiTech Systems, Inc. on the rCell – Intelligent Wireless Router FCCID:AU792U13A16855; Page 2 of 12 TABLE OF CONTENTS 1 Introduction and Conclusion .............................................................................................................. 3 2 Test Summary ...................................................................................................................................... 3 3 Description of Equipment Under Test ............................................................................................... 4 4 Radiated Output Power ....................................................................................................................... 6 5 Radiated Spurious Emissions (Transmitter) ..................................................................................... 7 6 Measurement Uncertainty ................................................................................................................. 11 7 Revision History ................................................................................................................................. 12 Intertek Report Number: 101549076LEX-004 Issued: 6/3/2014 EMC Report for MultiTech Systems, Inc. on the rCell – Intelligent Wireless Router FCCID:AU792U13A16855; Page 3 of 12 1 Introduction and Conclusion The tests indicated in section 2 were performed on the product constructed as described in section 3. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test method, a list of the actual test equipment used, documentation photos, results and raw data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complied with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. The INTERTEK-Lexington is located at 731 Enterprise Drive, Lexington Kentucky, 40510. The radiated emission test site is a 10-meter semi-anechoic chamber. The chamber meets the characteristics of CISPR 16-1 and ANSI C63.4. For measurements, a remotely controlled flush-mount metal-top turntable is used to rotate the EUT a full 360 degrees. A remote controlled non-conductive antenna mast is used to scan the antenna height from one to four meters. The test site is listed with the FCC under registration number 485103. The test site is listed with Industry Canada under site number IC 2042M-1. 2 Test Summary Page Test full name FCC Reference IC Reference Result - Conducted Output Power §2.1046 §24.232(d) RSS-129 (9.2.2) RSS-133 (4.1) RSS-133 (6.4) Pass 1 - Occupied Bandwidth §2.1049, §22.917(b)(d), and §24.238(a) RSS-GEN (4.6.1) RSS-133 (2.3) Pass 1 - Conducted Spurious Emissions §2.1049, §2.1051, §22.917(a)(b), and § 24.238(a)(b) RSS-129 (8.1.1), RSS-129 (9.3), RSS-129 (9.4), RSS-133 (6.5.1) Pass 1 6 Radiated Output Power § 22.913(a) and § 24.232(c) RSS-129 (9.1), RSS-133 (6.4) Pass 7 Radiated Spurious Emissions (Transmitter) §2.1053, §22.917(a)(b), and §24.238(a)(b) RSS-129 (8.1.1), RSS-133 (6.5) Pass - Frequency Stability §2.1055, §22.355, and §24.235 RSS-129 (9.2.1), RSS-133 (6.3) Pass 1 1 See module report also included in this filing. Intertek Report Number: 101549076LEX-004 Issued: 6/3/2014 EMC Report for MultiTech Systems, Inc. on the rCell – Intelligent Wireless Router FCCID:AU792U13A16855; Page 4 of 12 3 Description of Equipment Under Test Equipment Under Test Manufacturer MultiTech Systems, Inc. Model Number MTR-EV3-B10 Serial Number 5227149K FCC Identifier AU792U13A16855 Receive Date 3/31/2014 Test Start Date 3/31/2014 Test End Date 3/31/2014 Device Received Condition Good Test Sample Type Production Frequency Band 824MHz - 849MHz (CDMA Cell Band) 1850MHz – 1910MHz (CDMA PCS Band) Modulation Type CDMA Transmission Control Base Station Simulator Test Channels 1013, 384, and 777 (CDMA Cell Band) 25, 600, and 1075 (CDMA PCS Band) Antenna Type External antenna with 2.0dBi Gain Operating Voltage 115VAC/60Hz (Via AC/DC Power Adapter) Description of Equipment Under Test The MTR-EV3-B10 is an M2M Cellular Modem Operating modes of the EUT: No. Descriptions of EUT Exercising…
Text truncated - open the document above for the full version.
2205 Woodale Drive · Mounds View · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 274.00 mW | 1M29F9W | 2.5 ppm |

MTCAP3-L4G2D-AC3UVA-M, MTCAP3-L4G2D-AC3UWA-M
Equipment Class
DTS - Digital Transmission System
MTAC-003U00
Equipment Class
DTS - Digital Transmission System
MTCDTIP2
Equipment Class
DTS - Digital Transmission System
MTCAP2-915
Equipment Class
DTS - Digital Transmission System
MTAC-Lora-915
Equipment Class
DTS - Digital Transmission System