
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Register your new phone, purchase Ericsson original accessories, and see the latest in products by visiting us at: www.ericsson.com/us/consumer6/00 PBMThis manual is published by Ericsson Inc., without any warranty. Improvements and changes to this manual necessitated by typog raphical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by Ericsson Inc., at any time and without notice. Such changes will, however, be incorporated into new editions of this manual."Ericsson", "Ericsson " and "ERICSSON ORIGINAL ACCESSORIES" are each registered U.S. Trademarks owned by Telefonaktiebolaget LM Ericsson of Sweden.“Tegic" and "T9" are each registered U.S. Trademarks owned by Tegic Communications, Inc. of Seattle, Washington, U.S.A. The T9 ® text input product is provided under license from Tegic Communications Inc. and is covered by U.S. Pat. 5,818,437, U.S. Pat. 5,953,5 41, U.S. Pat. 6,011,554 and other patents pending. © 2000, Ericsson Inc. All rights reserved.Publication Number: AE/LZT 123 5632 R1 Printed in USA A2218z User’s Guide Some menus/features are operator dependent. i Guidelines for Safe and Efficient Use . . . . . 1Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Product Care and Operation . . . . . . . . . . . . . . . . . . . . . . .3Battery Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4FDA Consumer Update . . . . . . . . . . . . . . . . . . . . . . . . . .5A2218z Features . . . . . . . . . . . . . . . . . . . . . 10Getting Started . . . . . . . . . . . . . . . . . . . . . . . 13Demonstration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Assembling Your Phone . . . . . . . . . . . . . . . . . . . . . . . . . .13Powering On Your Phone . . . . . . . . . . . . . . . . . . . . . . . .16Display Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Display Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Using Menus . . . . . . . . . . . . . . . . . . . . . . . . 19Moving Through the Menus . . . . . . . . . . . . . . . . . . . . . .19Menu System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19My Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Making and Receiving Calls . . . . . . . . . . . . 22Making and Receiving Calls . . . . . . . . . . . . . . . . . . . . . .22During a Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Personalizing Your Phone . . . . . . . . . . . . . 25Ring Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25More Personalization Options . . . . . . . . . . . . . . . . . . . . 26Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Adding Accessories to a Profile . . . . . . . . . . . . . . . . . . . . 29Your Phone Book . . . . . . . . . . . . . . . . . . . . 30Memories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Creating a Phone Book Entry . . . . . . . . . . . . . . . . . . . . 30Calling a Phone Book Entry . . . . . . . . . . . . . . . . . . . . . 31Shortcuts to Phone Book Entries . . . . . . . . . . . . . . . . . . 31Keeping the Phone Book Up to Date . . . . . . . . . . . . . . . 31Copying Entries From One SIM to Another . . . . . . . . . 32Checking the Status of the Memories . . . . . . . . . . . . . . . 32When the SIM Card Memory Is Full . . . . . . . . . . . . . . . 32Telephone Banking Services . . . . . . . . . . . . . . . . . . . . . . 33Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33E-mail Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Entering Special Characters . . . . . . . . . . . . . . . . . . . . . . 34Using the Call List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Calling Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table of Contents Some menus/features are operator dependent.iiVoicemail Service . . . . . . . . . . . . . . . . . . . . 39Voicemail Notification . . . . . . . . . . . . . . . . . . . . . . . . . . 39Storing your Voicemail number . . . . . . . . . . . . . . . . . . . 39Calling Your Voicemail . . . . . . . . . . . . . . . . . . . . . . . . . . 39Changing the Message Alert Signal . . . . . . . . . . . . . . . . . 39Text Messaging (SMS). . . . . . . . . . . . . . . . . 41Enabling Your Phone to Send SMS . . . . . . . . . . . . . . . . 41Sending Text Messages . . . . . . . . . . . . . . . . . . . . . . . . . . 41Customizing Your Text Messages . . . . . . . . . . . . . . . . . . 42Templates for Text Messages . . . . . . . . . . . . . . . . . . . . . 42Receiving a Text Message . . . . . . . . . . . . . . . . . . . . . . . . 43Area Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Cell Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Call Information . . . . . . . . . . . . . . . . . . . . . . 47Total Call Time or Call Cost . . . . . . . . . . . . . . . . . . . . . 47Determining the Call Cost . . . . . . . . . . . . . . . . . . . . . . . 47Credit Limit for Calls . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Call Options . . . . . . . . . . . . . . . . . . . . . . . . . 49Call Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Restrict Calls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Fixed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Closed User Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Accept Calls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Handling Multiple Calls. . . . . . . . . . . . . . . . 53The Call Waiting Service . . . . . . . . . . . . . . . . . . . . . . . . 53Receiving a Second Call . . . . . . . . . . . . . . . . . . . . . . . . . 53Making a Second Call . . . . . . . . . . . . . . . . . . . . . . . . …
Text truncated - open the document above for the full version.
APPLICANT:FCC ID NO: ERICSSON INC.AXATR-389-A2 ©2000 Ericsson Inc. EXHIBIT 2A As per 22.919, Electronic Seal Numbers Protection Against Unauthorized ESN and Firmware Upgrades: The Electronic Serial Number (SNR) is part of the IMEI number of the phone. The IMEI bits in this Phone are encoded and spread over various nonsequential memory locations in order to prevent detection and modification. Once the factory has programmed the IMEI, the mobile firmware cannot overwrite or alter the IMEI memory locations. Both the IMEI host and operation systems components are permanently mounted to the mobile in order to prevent removal and misuse. Unauthorized attempts to alter the mobile’s firmware will cause the unit to become inoperable.
May 12, 2000 Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Attention: Equipment Authorization Branch Subject:Type Acceptance for FCC ID:AXATR-389-A2 Gentlemen, Ericsson Inc. requests a grant of Type Acceptance for the above mentioned FCC Identifier. This portable transceiver is designed for use in the GSM 1900 cellular telephone system. The mobile operates in the 1900 MHz Domestic Public Cellular Radiotelephone Communications Services, as per 47 CFR Part 24. It meets the requirements of GSM1900 11.10-1 version 4.19.1 specification for operation in GSM cellular systems. The mobile was tested and found compliant with 47 CFR Part 15, subpart B. The mobile operates in a temperature range of –20 to +60 degree C. This range is specified in the GSM air interface document. Employing temperature protection in the mobile controls the operating temperature range. Upon the temperature of the mobile exceeding this range, the mobile shuts down as indicated in the power versus temperature and frequency versus temperature plots. Conducted spurious emissions results are not included with this submittal as the antenna is an integral to the unit. Measurements and calculations for SAR have been made on this radio. This unit complies with IEEE C95.1-1991 (ANSI/IEEE C95.1-1992). Ericsson Inc. requests confidentiality under 47 CFR 0.459 for the following exhibit listed: Exhibit 4Block Diagrams Exhibit 5Circuit Diagrams Exhibit 10Parts List and Tune Up Information Exhibit 12Operational Description Exhibits 4, 5, 10 and 12 are marked CONFIDENTIAL on the electronic filing submission. Justification of this request is that in order to facilitate the circuit miniaturization of the AXATR-389-A2, certain proprietary techniques and custom components were implemented to reduce the board space required for the RF circuitry layout. These techniques are applicable to the design of the power amplifier and a unique method of implementing modulation. To protect Ericsson’s competitive advantage on these proprietary techniques, we request the above listed exhibit be held as confidential and withheld from the Public Information File. Sincerely, Jim Sponsler Regulatory Services Email: [email protected] Tel:(919) 472-6460 Fax:(919) 472-6382
APPLICANT:Exhibit 3 FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc. APPLICANT:Exhibit 3 FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc.
APPLICANT:Exhibit 1 FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc.
APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc.
Confidential REPORT 1 (12) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:0790/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-04-13A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z.doc E SAR Test Report: A2218z Date of test: April 12, 2000 Laboratory: Electromagnetic Near Field and Radio Frequency Dosimetry Laboratory Ericsson, Inc. 7001 Development Drive, P.O. Box 13969, Research Triangle Park, NC, 27709, USA Test Responsible: Mark Douglas, Ph.D. Senior Staff Engineer, Antenna Development Group [email protected] (919) 472-6334 Statement of Compliance Ericsson, Inc. declares under its sole responsibility that the that the product Ericsson A2218z to which this declaration relates, is in conformity with the appropriate RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (none) © Ericsson, Inc. 2000 This test report shall not be reproduced except in full, without written approval of the laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Ericsson encourages all feedback, both positive and negative, on this test report. Confidential REPORT 2 (12) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:0790/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-04-13A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z.doc E Table of Contents 1. Introduction0 2. Device Under Test0 2.1Antenna description0 2.2Device description0 3. Test equipment0 3.1 Dosimetric system0 3.2Additional equipment0 4. Electrical parameters of the tissue simulating liquid0 5. System accuracy verification0 6. Test results0 References0 Appendix 1: SAR distribution comparison for system accuracy verification0 Appendix 2: SAR distribution plots0 Appendix 3: Photographs of the device under test0 Appendix 4: Position of device on Generic Twin Phantom0 Appendix 5: Probe calibration parameters for ET3DV5 SN:13240 Confidential REPORT 3 (12) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:0790/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-04-13A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z.doc E 1. Introduction In this test report, compliance of the Ericsson A2218z portable telephone with RF safety guidelines is demonstrated (applicable RF safety guidelines are given in [1]). The device was tested in accordance with the latest available test guidelines [1]. Detailed procedures of the test are described in the Ericsson SAR Measurement Specification [2]. 2. Device Under Test 2.1 Antenna description Type Fixed stub Location Left side length30 mm Dimensions width at base10 mm Configuration Helix 2.2 Device description Device model A2218z Serial number UA2017RT93 Mode 1900 GSM Multiple Access Scheme TDMA Maximum Output Power Setting 1 29.5 dBm Factory Tolerance in Power Setting ± 0.25 Maximum Peak Output Power 2 29.75 dBm Duty Cycle 1 / 8 Transmitting Frequency Range 1850 – 1910 MHz Prototype or Production Unit 3 Prototype 3. Test equipment 3.1 Dosimetric system SAR measurements were made using the DASY3 professional system (software version 3.1c), manufactured by Schmid & Partner Engineering AG and installed Febuary, 1998. The total SAR assessment uncertainty (K = 1) of the system is ±16% and includes a +15% offset (overestimation). The extended uncertainty (K = 2) is ±32% with a +15% offset. This results in a total uncertainty range of –1% to +31% for K = 1, or –17% to +47% for K = 2. The equipment list is given below. Description Serial NumberDue Date DASY3 DAE V1 3454/01 E-field probe ETDV5 13244/01 Dipole Validation Kit, D1800V221712/01 1 This is the conducted power measured at the antenna port when the device is set to its highest power setting. It is measured at the middle of the transmit frequency band. Note that the output power may be different at other frequencies. 2 This equals the maximum output power setting plus the factory tolerance. 3 It shall be understood that a statement of compliance for a prototype unit also applies to production units [3]. Confidential REPORT 4 (12) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:0790/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-04-13A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z.doc E 3.2 Additional equipment Description Serial NumberDue Date Signal Generator HP8648C 3537A015989/00 Dielectric probe kit HP 85070B US330202568/00 Network analyzer HP 8752C 3410A031057/00 Power meter HP 437B3125U137292/01 Power sensor HP 8482H3318A070972/01 Radio communications analyzer Anritsu MT8801B MB124772/01 4. Electrical parameters of the tissue simulating liquid Prior to conducting SAR measurements, the relative permittivity, ε r , and the conductivity, σ, of the tissue simulating liquids were measured with the dielectric probe kit. These values are shown in the table below. The mass density, ρ, entered into the DASY3 program is also given. Recommended limits for maximum permittivity, minimum conductivity and maximum mass density are also shown [3]. It is seen that the measured parameters result in an overestimation of SAR compared to the recommended values. Dielectric Parametersf (MHz) Limits / Measured εε r σσ (S/m)ρρ (g/cm 3 ) Measured 41.181.711.00 1800 Recommended Limits [3] 43.541.151.03 5. System accuracy verification A system accuracy verification of the DASY3 was performed using the dipole validation kits listed in Section 3.1. The system verification test was conducted on the same day as the measurement of the DUT. The obtained results are d…
Text truncated - open the document above for the full version.
Internal limited DOCUMENT LIST1 (1) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other)Nr - No. KI/ERA/T/UF Christer TörnevikERA/T/U-98:442 Dokansv/Godk - Doc respons/ApprovedKontr - CheckedDatum - Date RevFile ERA/T/UF Christer Törnevik2000-03-17H \\ESEKINA001\ERATVIK$\H_christer\emfprogram\sarcontentH.doc Ericsson SAR Measurement Specification PartDocument nameDocument numberRev 1 2 3 4 5 6 7 8 9 10 Introduction and purpose Tissue liquid preparation Measurements of dielectric parameters System accuracy verification Calibration of equipment DUT preparation and characterization SAR measurement procedure Documentation of results Bibliography Glossary of symbols and acronyms ERA/T/U-98:446 ERA/T/U-98:404 ERA/T/U-98:405 EUS/TR/X-98:1585 EUS/TR/X-98:1586 ERA/T/U-98:439 ERA/T/U-98:441 ERA/T/U-98:447 ERA/T/U-99:047 EUS/TR/X-99:1336 C C D D D G G C D A Internal limited INSTRUCTION1 (4) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other)Nr - No. ERA/T/UF Christer TörnevikT/U-98:446 Dokansv/Godk – Doc respons/ApprovedKontr - CheckedDatum - Date RevFile ERA/T/UF Christer Törnevik2000-03-17C Ericsson SAR measurement specification, part 1: Introduction and purpose 1. Introduction It is an Ericsson policy that all RF transmitting products shall comply with existing recommendations, standards and regulations on human exposure to electromagnetic fields. In the reference section below, the most important RF safety guidelines are listed [1-8]. If no national standard or regulation is available in a country, the international recommendation from ICNIRP [1] shall be applied for Ericsson products. The RF safety guidelines specify basic restrictions and reference levels. In the frequency range of interest for mobile communications, the basic restrictions are expressed as Specific Absorption Rate (SAR) limits and the reference levels as field strength or power density limits. The reference levels are provided for the purpose of simple measurements of compliance with the basic restrictions, and they are primarily applicable in the farfield region of a RF source. Measured values greater than the reference levels do not necessarily mean that the basic restrictions are exceeded. In the nearfield region of mobile communication devices (handsets or base station antennas), field strength values exceeding the reference levels may be observed. Compliance with the basic SAR restrictions has therefor to be verified. SAR (W/kg) is a measure of the rate of RF energy absorption in tissue. The table below shows the localized SAR limits for the general public (uncontrolled environment) and workers (controlled environment) in the ICNIRP and ANSI/IEEE guidelines. Mobile communication equipment are usually used by the general public and should consequently be in compliance with the general public limits, which are 2.0 W/kg averaged in 10 gram of tissue in the ICNIRP guidelines and 1.6 W/kg averaged in 1 gram in the ANSI/IEEE standard. Because of the lower limit and the smaller averaging mass, the ANSI/IEEE limit is slightly more conservative than the ICNIRP limit. The averaging times are also different, 6 minutes in the ICNIRP recommendations and 30 minutes in the IEEE guidelines. The 2.0 W/kg (10 g) SAR limit has also been adopted in a European Prestandard from CENELEC [3] and in guidelines from the Ministry of Post and Telecommunications in Japan [4]. The 1.6 W/kg (1g) SAR limit has been adopted by the FCC as a regulation in the U.S. [6], and also as the basic restriction in preliminary Australian and Canadian standards [5,6]. The FCC requires SAR testing of mobile phones since 1997 [6,10]. Similar requirements were introduced in Australia February 1, 1999 [7] and will be introduced in Canada during 1999. In Europe and Japan regulations are expected within the next few years. SAR test standards for mobile communication equipment are under development by IEC, CENELEC, IEEE and ARIB. In the year 2000, it is expected that the first international standard will be published. Technical documents describing SAR test methods and procedures are already available from CENELEC, ARIB, ACA and the FCC [7-10]. Standard/GuidelineLocalized SAR limit (W/kg) General public (uncontrolled) Localized SAR limit (W/kg) Workers (controlled) ICNIRP (1998)2.0 (10 g)10 (10 g) ANSI/IEEE (1992)1.6 (1 g)8.0 (1g) Internal limited INSTRUCTION2 (4) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other)Nr - No. ERA/T/UF Christer TörnevikT/U-98:446 Dokansv/Godk – Doc respons/ApprovedKontr - CheckedDatum - Date RevFile ERA/T/UF Christer Törnevik2000-03-17C 2. Purpose of the Ericsson SAR measurement specification The purpose of the Ericsson SAR measurement specification is to describe how SAR tests shall be conducted in the three SAR test laboratories in Ericsson, which are: • The Ericsson EMF Research Laboratory at Ericsson Research in Kista (Contacts: ERA/T/UF Christer Törnevik or ERA/T/UD Martin Siegbahn) • The ECS SAR laboratory at Ericsson Mobile Communications in Lund (Contacts: ECS/TN/FAC Thomas Bolin or ECS/TA/FA Ramadan Plicanic) • The EUS SAR laboratory at Ericsson Inc. in RTP (Contacts: EUS Russ Holshouser or EUS Mark Douglas) All these laboratories are equipped with the DASY3 SAR test system from Schmid & Partner Engineering AG (SPEAG). Since there is not yet an official standard that defines and describes SAR test procedures, it is necessary to specify internal Ericsson procedures for testing of mobile communication equipment. When an international SAR test standard is available, the Ericsson SAR measurement specification will be partly or completely replaced by this standard. The Ericsson SAR measurement specification may be submitted to agencies like the FCC (USA), ACA (Australia) and Industry Canada if requested. 3. Applicability of the Ericsson SAR measurement specification The Ericsson SAR test measurement specification shall always be followed wh…
Text truncated - open the document above for the full version.
Confidential REPORT 1 (10) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:1455/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-07-12A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z addendum.doc E Addendum to “SAR Test Report: A2218z” Date of test: April 12, 2000 Laboratory: Electromagnetic Near Field and Radio Frequency Dosimetry Laboratory Ericsson, Inc. 7001 Development Drive, P.O. Box 13969, Research Triangle Park, NC, 27709, USA Test Responsible: Mark Douglas, Ph.D. Senior Staff Engineer, Antenna Development Group [email protected] (919) 472-6334 Statement of Compliance Ericsson, Inc. declares under its sole responsibility that the that the product Ericsson A2218z to which this declaration relates, is in conformity with the appropriate RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (none) © Ericsson, Inc. 2000 This test report shall not be reproduced except in full, without written approval of the laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Ericsson encourages all feedback, both positive and negative, on this test report. Confidential REPORT 2 (10) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:1455/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-07-12A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z addendum.doc E Table of Contents 1. Introduction0 2. Device Under Test0 2.1Antenna description0 2.2Device description0 3. Test equipment0 3.1 Dosimetric system0 3.2Additional equipment0 4. Electrical parameters of the tissue simulating liquid0 5. System accuracy verification0 6. Test results0 References0 Appendix 1: SAR distribution comparison for system accuracy verification0 Appendix 4: Position of device on Generic Twin Phantom0 Appendix 5: Probe calibration parameters for ET3DV5 SN:13240 Confidential REPORT 3 (10) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:1455/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-07-12A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z addendum.doc E 1. Introduction This test report is an addendum to report EUS/VR-00:0790/REP “SAR Test Report: A2218z”. In this report compliance of the Ericsson A2218z portable telephone with RF safety guidelines is demonstrated while the device is used against the body with a handsfree accessory (applicable RF safety guidelines are given in [1]). The device was tested in accordance with the latest available test guidelines [1]. Detailed procedures of the test are described in the Ericsson SAR Measurement Specification [2]. 2. Device Under Test Antenna description Type Fixed stub Location Left side length30 mm Dimensions width at base10 mm Configuration Helix Device description Device model A2218z Serial number UA2017RT93 Mode 1900 GSM Multiple Access Scheme TDMA Maximum Output Power Setting 1 29.5 dBm Factory Tolerance in Power Setting ± 0.25 Maximum Peak Output Power 2 29.75 dBm Duty Cycle 1 / 8 Transmitting Frequency Range 1850 – 1910 MHz Prototype or Production Unit Prototype 3. Test equipment 3.1 Dosimetric system SAR measurements were made using the DASY3 professional system (software version 3.1c), manufactured by Schmid & Partner Engineering AG and installed Febuary, 1998. The total SAR assessment uncertainty (K = 1) of the system is ±16% and includes a +15% offset (overestimation). The extended uncertainty (K = 2) is ±32% with a +15% offset. This results in a total uncertainty range of –1% to +31% for K = 1, or –17% to +47% for K = 2. The equipment list is given below. DescriptionSerial NumberDue Date DASY3 DAE V1 3454/01 E-field probe ETDV5 13244/01 Dipole Validation Kit, D1800V221712/01 1 This is the conducted power measured at the antenna port when the device is set to its highest power setting. It is measured at the middle of the transmit frequency band. Note that the output power may be different at other frequencies. 2 This equals the maximum output power setting plus the factory tolerance. Confidential REPORT 4 (10) Prepared (also subject responsible if other)No. RT/EUS/VR/X Mark Douglas919-472-6334 EUS/VR-00:1455/REP ApprovedCheckedDateRevFile EUS/VR/X Mark DouglasMGD2000-07-12A U:\FCC_TRNS\Fcc_389 Pat Margaretta\exhibit 11\A2218z addendum.doc E Additional equipment DescriptionSerial NumberDue Date Signal Generator HP8648C 3537A015989/00 Dielectric probe kit HP 85070B US330202568/00 Network analyzer HP 8752C 3410A031057/00 Power meter HP 437B3125U137292/01 Power sensor HP 8482H3318A070972/01 Radio communications analyzer Anritsu MT8801B MB124772/01 4. Electrical parameters of the tissue simulating liquid Prior to conducting SAR measurements, the relative permittivity, ε r , and the conductivity, σ, of the tissue simulating liquids were measured with the dielectric probe kit. These values are shown in the table below. The mass density, ρ, entered into the DASY3 program is also given. Recommended limits for maximum permittivity, minimum conductivity and maximum mass density are also shown [3]. It is seen that the measured parameters result in an overestimation of SAR compared to the recommended values. Dielectric Parameters f (MHz) Limits / Measured εε r σσ (S/m)ρρ (g/cm 3 ) Measured, 4/12/00 41.181.711.00 1800 Limits, muscle [3] 54.441.391.04 5. System accuracy verification A system accuracy verification of the DASY3 was performed using the dipole validation kits listed in Section 3.1. The system verification test was conducted on the same day as the measurement of the DUT. The obtained results are displayed i…
Text truncated - open the document above for the full version.
To: Frank Coperich/ Kwok Chan FCC Application Processing Branch Re:FCC ID AXATR-389-A2 Applicant:Ericsson Inc Correspondence Reference Number:15116 731 Confirmation Number:EA97574 Date of Original E-Mail:07/14/2000 Frank/Kwok, Below is a copy of your request and our response to correspondence 15116. The statement below allows us to meet the requirements for free trade and your concerns on the use of third party accessories. As was discussed with Kwok, we plan to place this statement on an insert with the manual until we are able to use our existing stock of manuals. Future manuals will have the statement added into the safety section of the manual. The final statement to be placed into the manual may remove the line denoted in bold and underlined below. Your request: Please upload relevant page(s) of the manual containing the body-worn operating instructions and requirements for users to comply with SAR limit. This info should be at a location that is obvious to the users, please indicate its location in the manual. Our response: Body Worn statement Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (i.e., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is xxx and when worn on the body is xxx. Body worn measurements are made while the phone is in use and worn on the body with an Ericsson accessory. The design and composition of an accessory can affect the body worn SAR levels for the phone. Ericsson has not measured, and makes no representation about the body worn SAR levels when the phone is used with non-Ericsson accessories. If you have any questions, feel free to contact me. Jim Sponsler 919-472-6460 [email protected]
APPLICANT: FCC ID NO: ERICSSON INCAXATR-389-A2 ©2000 Ericsson Inc. Exhibit 6 INDEX OF TEST RESULTS Exhibit #Description 6A1900MHz/Part 24: RF Power 6B1900MHz/Part 24: Modulation Characteristics 6C1900MHz/Part 24: Occupied bandwidth 6D1900MHz/Part 24: Spurious Emissions (conducted) 6E1900MHz/Part 24: Spurious Emissions (radiated) 6F1900MHz/Part 24: Frequency Stability APPLICANT:FCC ID NO: ERICSSON INCAXATR-389-A2 © 2000 Ericsson Inc. EXHIBIT 6A1 1900MHz GSM RF POWER OUTPUT Para. 2.1033 (c,6,7), 2.1046 The RF power measured at the output terminals (antenna connector) is plotted against supply voltage variati…
Text truncated - open the document above for the full version.
7001 Development Drive · RTP, North Carolina · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.85 GHz - 1.91 GHz | 1.7 W | 255KGXW | 1.0000000000 ppm |

CM-42
Equipment Class
PCB - PCS Licensed Transmitter
DM-15
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Dual Mode TDMA Cellular Handset
Equipment Class
TNE - Licensed Non-Broadcast Transmitter Held to Ear
Dual Mode TDMA Cellular Transceiver
Equipment Class
TNE - Licensed Non-Broadcast Transmitter Held to Earcellular/pcs portable terminal
Equipment Class
PCE - PCS Licensed Transmitter held to ear