FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HARRIS CORPORATION/
  3. AXATR-417-A2

AXATR-417-A2Cellular Phone

HARRIS CORPORATION
Cellular Phone - FCC ID AXATR-417-A2 - HARRIS CORPORATION
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jun 24, 2001
Application Purpose
Original Equipment
Date of Application
Apr 30, 2001
Equipment Note
Cellular Phone
Frequency Range
1850.00000000 - 1910.00000000
Company
HARRIS CORPORATION
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

!"  LZT 123 4598/12 R1 THIS MODEL PHONE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES.Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by indepen-dent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health.The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg.* Tests for SAR are conducted using standard operating positions accepted by the FCC with the phone trans-mitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (i.e., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value as reported to the FCC for this model phone when tested for use at the ear is 1.35 W/kg and when worn on the body is .83 W/kg. Body worn mea-surements are made while the phone is in use and worn on the body with an Ericsson accessory. The design and composition of an accessory can affect the body worn SAR levels for the phone. Ericsson has not measured, and makes no representation about the body worn SAR levels when the phone is used with non-Ericsson accessories.The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. While there may be differences between the SAR levels of various phones, all mobiles granted a FCC equipment authorization meet the government requirement for safe exposure. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/oet/ fccid after searching on FCC ID AXATR-417-A2. Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications & Internet Association (CTIA) web-site at http://www.phonefacts.net/ . ___________________________________* In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kilogram (W/kg) averaged over one gram of tissue. The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements. Important Information Mobile Phone T60d User’s Guide PRELIMINARY Para obtener una copia en español de esta Guía del Usuario, visite nuestra página Web en www.ericsson.com/phones o, si se encuentra en Estados Unidos, también puede llamar al 1-800-374-2776. Register your new phone, purchase Ericsson original accessories, and see the latest in products by visiting us at: www.ericsson.com/phones 8/01 PBM This manual is published by Ericsson Inc., without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by Ericsson Inc., at any time and without notice. Such changes will, however, be incorporated into new editions of this manual. “Ericsson”, “Ericsson  ” and “ERICSSON ORIGINAL ACCESSORIES” are each registered U.S. Trademarks owned by Telefonaktiebolaget L M Ericsson of Sweden. “Microsoft”, “Windows” and the design plus words “Microsoft Windows” are each either registered and/or pending U.S. Trademarks owned by Microsoft Corporation of Redmond, Washington, U.S.A. Trademarks referred to herein are trademarks of their respective companies. T9 Text Input is licensed under one or more of the following: U.S. Pat. Nos. 5,818,437, 5,953,541, 5,187,480, 5,945,928, and 6,011,554; Canadian Pat. No. 1,331,057; United Kingdom Pat. No.2238414B; Hong Kong Standard Pat. No. HK0940329; Republic of Singapore Pat. No. 51383; Euro.Pat. No. 0 842 463 (96927260.8) DE/DK, FI, FR, IT,NL,PT.ES,SE,GB; and additional patents are pending worldwide. © 2001, Ericsson Inc. All rights reserved. Publication Number: AE/LZT 123 6623 P1B Printed in USA Table of ContentsAbout this User’s Guide.............................. 9Getting Started ........................................... 11Voice Operation ......................................... 21Menus ........................................................ 25Using the Phonebook ................................. 41Voice Command......................................... 53Text Input .................................................. 67Using the Calendar ..................................... 71Making Data and Fax Calls......................... 75 1 Guidelines for Safe and Efficient Use Since its introduction in the mid 1980s, the mobile phone has been one of the most exciting and innovative products ever developed. Your phone can help you to stay in touch with your office, your home, emergency services and others. SafetyExposure to Radio Frequency Signals Your wireless handheld portable telephone is a low power radio transmitter and receiver. When it is ON, it receives and …

Text truncated - open the document above for the full version.

Attestation Statements

APPLICANT: FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. EXHIBIT 2 Index for Exhibit Exhibit #Description 2AProtection Against Unauthorized ESN and Firmware Upgrades 2BCertification of Data 2CCompliance Statement to Part 22.921, 911 Call Processing Procedures

Cover Letter(s)

May 1, 2001 Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Attention: Equipment Authorization Branch Subject:Type Acceptance for FCC ID:AXATR-417-A2 Model: T60d Gentlemen, Ericsson Inc. requests a grant of Type Acceptance for the above mentioned FCC Identifier. This portable transceiver is designed for use in the AMPS/DAMPS cellular telephone system. The mobile operates in the 800 MHz Domestic Public Cellular Radiotelephone Communications Services per Subpart H of Part 22 and operating in the 1900 MHz Domestic Public Cellular Radiotelephone Communications Services, as per Part 24. When operating in the 1900 MHz range, DAMPS technology will be employed. It meets the requirements of IS-137A for operation in cellular systems. Documents governing DAMPS were used as a guide. Measurements and calculations for SAR have been made on this radio. This unit complies with IEEE C95.1-1991 (ANSI/IEEE C95.1-1992). Ericsson Inc. requests confidentiality under 47 CFR 0.459 for the following exhibit listed: Exhibit 4Block Diagrams Exhibit 5Circuit Diagrams Exhibit 10Tune-up Procedure Justification of this request is that in order to facilitate the circuit miniaturization of the AXATR- 417-A2, certain proprietary techniques were implemented to reduce the board space required for the RF circuitry layout. These techniques are applicable to the design of the power amplifier and a unique method of implementing modulation. To protect Ericsson’s competitive advantage on these proprietary techniques, we request the above listed exhibits be held as confidential and withheld from the Public Information File. Sincerely, Pierre Chery Regulatory Services Tel No:(919) 472-1697 Research Triangle Park, NCFax No:(919) 472-6382

Cover Letter(s)

June 22, 2001 Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Attention: Andy Leimer/Equipment Authorization Branch Subject:Type Acceptance for FCC ID: AXATR-417-A2 Reference Number:19546 731 Confirmation No.:EA100832 Dear Mr. Leimer: The following are responses to the above correspondence reference number dated 6 June, 2001. 1) The internal photo exhibit now includes photos showing the component side of all boards. There are photos with the RF shielding in place as well as photos with the RF shielding removed. 2) Concerning Part 24’s EIRP requirement, thank you for converting the submitted data from ERP to EIRP. 3) Exhibit 2 contains letters of attestation stating compliance to 911 Call Processing and ESN Security. 4) The preliminary user manual indicates two batteries, however, this product will only be marketed with the Lithium Ion battery which was the battery used for the SAR measurements/report. This correction has been made to the user manual and will be filed with the Commission when the final version of the manual is ready. The final version of the manual containing this correction will be submitted to the Commission prior to product launch to the market. 5) The additional information concerning RF exposure and unapproved Ericsson accessories is included in the “Product Care and Operation” section of the user manual beginning on page 4. On page 5 it is stated: Only Ericsson original accessories are recommended. And on page 6 it is stated: Ericsson has not measured, and makes no representation about the body worn SAR levels when the phone is used with non-Ericsson accessories. This information is also included in the SAR insert page. I hope the Commission will find the responses and proposed action satisfactory for the issuance of the grant of equipment authorization for this product. Sincerely, Pierre Chery Regulatory Services Tel No:(919) 472-1697 Research Triangle Park, NCFax No:(919) 472-6382

External Photos

APPLICANT:Exhibit 3 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 3 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc.

ID Label/Location Info

APPLICANT:Exhibit 1 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. NOTE: THE FCC ID NUMBER ON THE LABEL MAY OR MAY NOT BE CIRCUMSCRIBED

Internal Photos

APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc.

Internal Photos

APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc. APPLICANT:Exhibit 9 FCC ID NO: ERICSSON INCAXATR-417-A2 ©2001 Ericsson Inc.

RF Exposure Info

Uppgjord -Prepared ERA/T/F Martin Siegbahn Godkänd -Approved ERA/T/FC (Christer Törnevik) Kontr. -Checked Datum -Date 2001-03-20 Ert datum -Your date Rev B Dokumentnr -Document no T/F 00:037 Blad -Sheet 1 (1) Tillhör referens -File /reference Tfn -Telephone 75-70811 Dokument -Document Document list INTERNAL LIMITED Ericsson SAR Measurement Specification PartDocument nameDocument numberRev 1Introduction and purposeERA/T/U-98:446C 2Tissue liquid preparationERA/T/F-00:032A 3Measurements of dielectric parametersERA/T/U-98:405F 4System accuracy verificationEUS/CV/R-000017/PROB 5Calibration of equipmentEUS/TR/X-98:1586D 6DUT preparation and characterizationERA/T/F-01:006A 7SAR measurement procedureERA/T/F-01:036A 8Documentation of resultsERA/T/U-98:447C 9BibliographyERA/T/U-99:047D 10Glossary of symbolsEUS/TR/X-99:1336A Internal limited INSTRUCTION1 (4) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other)Nr - No. ERA/T/UF Christer TörnevikT/U-98:446 Dokansv/Godk – Doc respons/ApprovedKontr - CheckedDatum - Date RevFile ERA/T/UF Christer Törnevik2000-03-17C Ericsson SAR measurement specification, part 1: Introduction and purpose 1. Introduction It is an Ericsson policy that all RF transmitting products shall comply with existing recommendations, standards and regulations on human exposure to electromagnetic fields. In the reference section below, the most important RF safety guidelines are listed [1-8]. If no national standard or regulation is available in a country, the international recommendation from ICNIRP [1] shall be applied for Ericsson products. The RF safety guidelines specify basic restrictions and reference levels. In the frequency range of interest for mobile communications, the basic restrictions are expressed as Specific Absorption Rate (SAR) limits and the reference levels as field strength or power density limits. The reference levels are provided for the purpose of simple measurements of compliance with the basic restrictions, and they are primarily applicable in the farfield region of a RF source. Measured values greater than the reference levels do not necessarily mean that the basic restrictions are exceeded. In the nearfield region of mobile communication devices (handsets or base station antennas), field strength values exceeding the reference levels may be observed. Compliance with the basic SAR restrictions has therefor to be verified. SAR (W/kg) is a measure of the rate of RF energy absorption in tissue. The table below shows the localized SAR limits for the general public (uncontrolled environment) and workers (controlled environment) in the ICNIRP and ANSI/IEEE guidelines. Mobile communication equipment are usually used by the general public and should consequently be in compliance with the general public limits, which are 2.0 W/kg averaged in 10 gram of tissue in the ICNIRP guidelines and 1.6 W/kg averaged in 1 gram in the ANSI/IEEE standard. Because of the lower limit and the smaller averaging mass, the ANSI/IEEE limit is slightly more conservative than the ICNIRP limit. The averaging times are also different, 6 minutes in the ICNIRP recommendations and 30 minutes in the IEEE guidelines. The 2.0 W/kg (10 g) SAR limit has also been adopted in a European Prestandard from CENELEC [3] and in guidelines from the Ministry of Post and Telecommunications in Japan [4]. The 1.6 W/kg (1g) SAR limit has been adopted by the FCC as a regulation in the U.S. [6], and also as the basic restriction in preliminary Australian and Canadian standards [5,6]. The FCC requires SAR testing of mobile phones since 1997 [6,10]. Similar requirements were introduced in Australia February 1, 1999 [7] and will be introduced in Canada during 1999. In Europe and Japan regulations are expected within the next few years. SAR test standards for mobile communication equipment are under development by IEC, CENELEC, IEEE and ARIB. In the year 2000, it is expected that the first international standard will be published. Technical documents describing SAR test methods and procedures are already available from CENELEC, ARIB, ACA and the FCC [7-10]. Standard/GuidelineLocalized SAR limit (W/kg) General public (uncontrolled) Localized SAR limit (W/kg) Workers (controlled) ICNIRP (1998)2.0 (10 g)10 (10 g) ANSI/IEEE (1992)1.6 (1 g)8.0 (1g) Internal limited INSTRUCTION2 (4) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other)Nr - No. ERA/T/UF Christer TörnevikT/U-98:446 Dokansv/Godk – Doc respons/ApprovedKontr - CheckedDatum - Date RevFile ERA/T/UF Christer Törnevik2000-03-17C 2. Purpose of the Ericsson SAR measurement specification The purpose of the Ericsson SAR measurement specification is to describe how SAR tests shall be conducted in the three SAR test laboratories in Ericsson, which are: • The Ericsson EMF Research Laboratory at Ericsson Research in Kista (Contacts: ERA/T/UF Christer Törnevik or ERA/T/UD Martin Siegbahn) • The ECS SAR laboratory at Ericsson Mobile Communications in Lund (Contacts: ECS/TN/FAC Thomas Bolin or ECS/TA/FA Ramadan Plicanic) • The EUS SAR laboratory at Ericsson Inc. in RTP (Contacts: EUS Russ Holshouser or EUS Mark Douglas) All these laboratories are equipped with the DASY3 SAR test system from Schmid & Partner Engineering AG (SPEAG). Since there is not yet an official standard that defines and describes SAR test procedures, it is necessary to specify internal Ericsson procedures for testing of mobile communication equipment. When an international SAR test standard is available, the Ericsson SAR measurement specification will be partly or completely replaced by this standard. The Ericsson SAR measurement specification may be submitted to agencies like the FCC (USA), ACA (Australia) and Industry Canada if requested. 3. Applicability of the Ericsson SAR measurement specification The Ericsson SAR test measurement specification shall always be followed when testing for compliance with SAR limits for handheld radio produ…

Text truncated - open the document above for the full version.

RF Exposure Info

REPORT 1 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN SAR Test Report: T60d Date of test: April 10-12, and 16, 2001 Laboratory: Electromagnetic Near Field and Radio Frequency Dosimetry Laboratory Ericsson, Inc. 7001 Development Drive, P.O. Box 13969, Research Triangle Park, NC, 27709, USA Test Responsible: Mark Douglas, Ph.D. Senior Technical Leader, Antenna Development Group This laboratory is accredited to ISO/IEC Guide 25-1990 to perform the following electromagnetic tests: Specific Absorption Rate (SAR), dielectric parameters, and RF power measurement on the following types of products: Wireless communications devices A2LA certificate Number: 1650-01 Statement of Compliance: Ericsson, Inc. declares under its sole responsibility that the product T60d to which this declaration relates, is in conformity with the appropriate RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (none) © Ericsson, Inc. 2001 This test report shall not be reproduced except in full, without written approval of the laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Ericsson encourages all feedback, both positive and negative, on this test report. REPORT 2 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Table of Contents 1. Introduction3 2. Device Under Test3 2.1 Antenna description3 2.2 Device description3 3. Test equipment3 3.1 Dosimetric system3 3.2 Additional equipment4 4. Electrical parameters of the tissue simulating liquid4 5. System accuracy verification4 6. Test results5 References7 Appendix 1: SAR distribution comparison for system accuracy verification7 Appendix 2: SAR distribution plots15 Appendix 3: Photographs of Device Under Test24 Appendix 4: Position of Device on Phantom29 Appendix 5: Probe calibration parameters33 REPORT 3 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN 1. Introduction In this report, compliance of the Ericsson T60d portable telephone with RF safety guidelines is demonstrated (applicable RF safety guidelines are given in [1]). The device was tested in accordance with the latest available test guidelines [1]. Detailed procedures of the test are described in the Ericsson SAR Measurement Specification [1]. 2. Device Under Test 2.1 Antenna description Type Internal antenna Location Inside the back cover, near the top Maximum length38 mm Dimensions Maximum width51 mm Configuration Patch antenna 2.2 Device description Device model T60d FCC ID AXATR-417-A2 Serial number UA2020480H Mode 800 AMPS800 TDMA1900 TDMA Multiple Access Scheme FDMATDMATDMA Maximum Output Power Setting 1 26.0 dBm26.0 dBm26.0 dBm Factory Tolerance in Power Setting ± 0.25± 0.25± 0.25 Maximum Peak Output Power 2 26.25 dBm26.25 dBm26.25 dBm Duty Cycle 11 / 31 / 3 Transmitting Frequency Range 824 – 849 MHz824 – 849 MHz1850 – 1910 MHz Prototype or Production Unit Prototype 3. Test equipment 3.1 Dosimetric system SAR measurements were made using two DASY3 professional systems (software version 3.1c), manufactured by Schmid & Partner Engineering AG and installed in February 1998, and November 2000. The extended SAR assessment uncertainty (K = 2) is ±32% with a +15% offset. This assessment uncertainty includes measurement uncertainty (±24%) and phantom uncertainty (±10%), as described in [1]. This results in a total uncertainty range of –17% to +47%. The equipment list is given below. Description Serial NumberDue Date DASY3 DAE V1 36912/01 E-field probe ET3DV615389/01 E-field probe ET3DV513376/01 Dipole Validation Kit, D900V20491/03 Dipole Validation Kit, D1800V221712/01 1 This is the conducted power measured at the antenna port when the device is set to its highest power setting. It is measured at the middle of the transmit frequency band. Note that the output power may be different at other frequencies. 2 This equals the maximum output power setting plus the factory tolerance. REPORT 4 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN 3.2 Additional equipment DescriptionSerial NumberDue Date Signal Generator HP8648C 3537A015989/02 Dielectric probe kit HP 85070B US3302025610/01 Network analyser HP 8752C 3410A031057/01 Power meter E4418BGB4020659410/01 Power sensor HP 8482H3318A092688/01 Power meter HP 437B3125U161903/02 Power sensor HP 8482H2704A062354/01 Power meter HP 437B3125U137291/02 Power sensor HP 8482H3318A070972/02 4. Electrical parameters of the tissue simulating liquid Prior to conducting SAR measurements, the relative permittivity, ε r , and the conductivity, σ, of the tissue simulating liquids were measured with the dielectric probe kit. These values are shown in the table below. The mass density, ρ, entered into the DASY3 program is also given. Recommended limits for maximum permittivity, minimum conductivity and maximum mass density are also shown [2]. It is seen that the measured parameters result in an overestimation of SAR compared to the recommended values. Dielectric Parameters f (MHz) Tissue type Limits / Measured ε r σ (S/m)ρ (g/cm 3 ) Chamber Temp. (°C)…

Text truncated - open the document above for the full version.

RF Exposure Info

REPORT 19 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Distribution of maximum SAR in 1900 PCS band. Measured against the body using product # SXK –109-4518/1 as a carry case. REPORT 20 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Distribution of maximum SAR in 800 AMPS band. Measured against the body using product # SXK –109-4518/2 as a carry case. REPORT 21 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Distribution of maximum SAR in 1900 PCS band. Measured against the body using product # SXK –109-4518/2 as a carry case. REPORT 22 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Distribution of maximum SAR in 800 AMPS band. Measured against the body using product # SXK –107-6820/55 as a carry case. REPORT 23 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Distribution of maximum SAR in 1900 PCS band. Measured against the body using product # SXK –107-6820/55 as a carry case. REPORT 24 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Appendix 3: Photographs of Device Under Test Front view of deviceBack view of device REPORT 25 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Side view of device. REPORT 26 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Front, back, and side views of product number SXK –109-4518/1 REPORT 27 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN REPORT 28 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Front, back, and side views of product number SXK –109-4518/2 REPORT 29 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Front, side, and back views of part number SXK 107 6820/55. REPORT 30 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Appendix 4: Position of Device on Phantom Position of device against head phantom. REPORT 31 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Position of device against flat phantom using carry accessory SXK –109-4518/1 . REPORT 32 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN REPORT 33 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Position of device against flat phantom using carry accessory SXK –109-4518/2 REPORT 34 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Position of device against flat phantom using carry accessory SXK 107 6820/55. REPORT 35 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN Appendix 5: Probe calibration parameters REPORT 36 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN REPORT 37 (37) Prepared (also subject responsible if other)No. EUS/CV/RF/P Will Stewart EUS/CV/R-01:0484/REP ApprovedChecked EUS/CV/RF/P Mark DouglasMGD2001-4-25C U:\FCC Submittals\FCC_417 Ditto Nicole\XHIBIT11\New SAR.doc EN

Test Report

APPLICANT:FCC ID NO: ERICSSON INCAXATR-417-A2 © 2001 Ericsson Inc. Exhibit 6 INDEX OF TEST RESULTS Exhibit #Description 6A800 band/Part 22/AMPS: RF Power 6B800 band/Part 22/AMPS: Modulation Characteristics 6C800 band/Part 22/AMPS: Occupied bandwidth 6D800 band/Part 22/AMPS: Spurious Emissions (conducted) 6E800 band/Part 22/AMPS: Spurious Emissions (radiated) 6F800 band/Part 22/AMPS: Frequency Stability 6G800 band/Part 22/DAMPS: RF Power 6H800 band/Part 22/DAMPS: Modulation Characteristics 6I800 band/Part 22/DAMPS: Occupied bandwidth 6J800 band/Part 22/DAMPS: Spurious Emissions (conducted) 6K800 band/Part 22/DAMPS: Spurious Emissions (radiated) 6L800 band/Part 22/DAMPS: Frequency Stability 6M1900MHz/Part 24: RF Power 6N1900MHz/Part 24: Modulation Characteristics 6O1900MHz/Part 24: Occupied bandwidth 6P1900MHz/Part 24: Spurious Emissions (conducted) 6Q1900MHz/Part 24: Spurious Emissions (radiated) 6R1900MHz/Part 24: Frequency Stability APPLICANT:FCC ID NO: ERICSSON INCAXATR-417-A2 © 2001 Ericsson Inc. EXHIBIT 6A1 800 MHz: AMPS RF POWER OUTPUT Para. 2.1033 (c)(6)(7), 2.1046 and 22.913 (a) For Canada use only (6A2 and 6A3): The RF power measured at the output terminal (antenna connector) is plotted against supply voltage variations and temperature variations at the highest levels. Exhibit Voltage (V) Temperature TX Freq Power Level 6A23.8VariedMid-Band0 6A3Varied+25 CMid-Band0 Note: …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Thomas Camper, Jr.(Regulatory Manager)
[email protected]434-455-9367Fax: 434-455-6851

Technical Contact

ERICSSON INC.PIERRE A CHERY
[email protected]919 472 1697

7001 DEVELOPMENT DR. · RESEARCH TRIANGLE PARK, North Carolina · United States

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.91 GHz632.00 mW30K0DXW2.5 ppm
Confidentiality
Long Term

Other Applications from HARRIS CORPORATION

CM-42 - FCC ID AXATR-423-A2 - HARRIS CORPORATION
AXATR-423-A2

CM-42

Jul 14, 2004

Equipment Class

PCB - PCS Licensed Transmitter
DM-15 - FCC ID AXATR-420-A2 - HARRIS CORPORATION
AXATR-420-A2

DM-15

Mar 21, 2002

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Dual Mode TDMA Cellular Handset - FCC ID AXATR-422-A2 - HARRIS CORPORATION
AXATR-422-A2

Dual Mode TDMA Cellular Handset

Mar 13, 2002

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
Dual Mode TDMA Cellular Transceiver - FCC ID AXATR-421-A2 - HARRIS CORPORATION
AXATR-421-A2

Dual Mode TDMA Cellular Transceiver

Dec 19, 2001

Equipment Class

TNE - Licensed Non-Broadcast Transmitter Held to Ear
AXATR-413-A2

cellular/pcs portable terminal

Aug 14, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear