Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Initializing Door/Window SensorsRemove the screw from the front of the Door/Window Sensor andinstall 2 AAA alkaline batteries inside.Set switch to MAX (left) for windows, or MIN (right) for doors.Press and hold the TEST button on the Sensor for a second and thenrelease it. This initializes the Sensor and picks a random code that isused when it is registered with the Console. ENTER PIN12:00 am****12:00 am 1. INSTALL Entering the PIN clears the top line and shows * for each number entered. Thedefault PIN is 0000, you’ll find out later how you can change this, but for now press0000 on the keyboard under the Console’s flip up lid.This takes you to the first level of the menu at step 1. This is the INSTALLATIONlevel. The display looks like this:Press OK and the display looks like this:Registering Door/Window SensorsPress either of the Console’s 2 Menu up/down buttons (to the right of the display).The display then shows ENTER PIN (Personal Identification Number) in the topline. 1. INSTALLZONE Now simply press the TEST button on the Door/Window Sensor. The Console willacknowledge that it has been registered by displaying ZONE 1 SET.Repeat this for any other Door/Window Sensors you want to register. The displayincrements to ZONE 2 SET, etc. as you install more Door Window Sensors. If desired, you can specify what zone you want the Door Window Sensor to beinstalled into. Just press the number of the zone you want on the Console’s keypad,and then press the TEST button on the Door Window Sensor.Press Clear to back out of the menu. After a short delay the display reverts toshowing HOME CONTROL on the top line and the time of day on the bottom line.• Attach the Door/Window Sensor to the wall using the mounting screws provided.• Fit the Door/Window Sensor as high as possible at the top of the door/window.• Make sure the arrows on the magnetic and the Door/Window Sensor are facing each other and that they separate cleanly when the door or window is opened. • To protect two doors or windows close to each other, use the Door/Window Sensor with an additional set of magnetic switch contacts as show in the diagramsabove. • Set the DELAY slide switch to MIN (to the right) to always trigger the alarm instantly (for windows), or to MAX (to the left) to trigger the alarm after a presetentry delay when the system is armed in DELAY mode (for doors) . The numbers 1 –32 in the display refer to up to 32 “zones.” These represent theDoor/Window Sensors (and/or Motion Detectors) you install. The numbers showopen zones, problem zones and bypassed zones by being displayed as steady on(door or window open), slow flash (there’s a problem with that zone) or fast flash(that zone has been bypassed). Attempting to arm with an open or problem zonemakes the unit beep continuously and the unit will display in words on the displaywhat the cause is, but only for one zone at a time. Bypassing that zone (by pressingthe Clear button) moves on to the next problem zone, if there is one. Two doors orwindows (requiresaccessory magneticswitch pair) Ideal location Sliding window Installing the Door/Window Sensor Battery ReplacementIf any zone shows LOW BATT on the Console’s display, the Door/Window Sensorfor that zone will need its batteries replacing. Also, if a zone has not reported induring the last four hours, the display will show PROBLEM. This is most likelycaused by dead batteries.As long as the batteries have not completely failed they may be replaced with freshbatteries without the need to reinstall the sensor. After removing the old batteriesfresh batteries must be fitted within 30 seconds to ensure that the security code isretained.Testing the Door/Window SensorOnce the batteries have been replaced, the Door/Window Sensor should be tested asfollows:• Make sure the system is NOT armed.• Open the door or window with the sensor attached. The Console chimes to acknowledge and the zone # is displayed on the LCD. FCC StatementThis equipment generates and uses radio frequency energy, and if not installed andused properly, that is, in strict accordance with the manufacturers instructions, maycause interference to radio and television reception. It has been type tested and foundto comply with the limits for remote control security devices in accordance with thespecifications in Sub-Parts B and C of Part 15 of FCC Rules , which are designed to provide reasonable protection against such interference in a residential installation.However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause interference to radio or television recep-tion, which can be determined by unplugging the equipment, try to correct theinterference by one or more of the following measures.• Reorient the antenna of the radio/TV experiencing the interference.• Relocate the Console with respect to the radio/TV. • Move the Console away from the radio/TV.• Plug the Console into an outlet on a different electrical circuit from the radio/TV experiencing the interference. If necessary, consult your local RadioShack store for additional suggestions. Door/Window Sensor Cat. No 49-1001 The plug ‘n power Supervised Security System Cat. No 49-1000 includes a SecurityConsole with an automatic dialer that calls neighbors or friends in the event of abreak in. A battery powered RF Door/Window Sensors and battery powered RFMotion Detector to trigger the alarm, and an RF and Keychain Remote control forarming and disarming the system. All sensors and remotes incorporate randomdigital security coding.The system may be configured with any combination of the following items:• Up to 16* Keychain Security Remotes with arm/disarm and panic functions, and buttons to control security lights in and around the home. • Up to 32* magnetic switch operated wireless Door/Window Sensors.• Up to 32* wireless PIR Motion Detectors.• Additional plug ‘n power Home Automation modules such as plug-in lamp and appliance modules and wired-in replacement w…
Text truncated - open the document above for the full version.
TAMPER SWITCH Reed Switch MCU EM78P153S 310MHz RFTRANSMITTER BLOCK DIAGRAM FOR D/W SensorModel DS11A (49-1001) 310MHz
Door/Window Sensor Cat. No. 49-1001 FCC ID: B4S-DS11A DS11A (49-1001) Door/Window Sensor rating label 2:1 4/13/04 Custom Manufactured in China for RadioShack Corp., Ft. Worth, TX 76102 For use with plug 'n power ® Security System, Cat. No. 49-1000. Use two AAA alkaline batteries. FOR INDOOR USE ONLY. No user serviceable parts inside.
X-10 Model DS11A Operational Description The model DS11A is a door/window security sensor used with a wireless home alarm system. The device is placed at the junction between a door or window and it’s frame. When the door or window is closed the magnet pulls the internal magnetic switch closed. When the door or window is opened the magnetic switch opens which activates the 310 MHz pulsed RF transmitter inside the DS11A. The DS11A then transmits its own identifying pulse code to the alarm receiver. If the alarm system is armed an alarm condition will occur.
DS11ADOOR WINDOW SENSOR200403221 117000H10011MAGNET200403231 183010H22690BATTERY HOLDER200403221 185000H22870TOP CABINET200403221 185000H22880BOTTOM CABINET200403221 391-60202130SCREW-PPTT M2.3X5 MS/ZP200403221 391-60204040SCREW-PPTT M3X10 MS/ZP200403222 391-60204050SCREW-PPTT M3X12200403221 403011H10329KNOB SPRING200403221 403011H10330SPRING CONTACT COMMON200403221 851001H12073PCB ASSY200403231 042010H11150APCB200403231 057-22900006CAP-E 2U2 20% 50V 4X7200403231 C22 076-10000012CAP-MCC 10P .25P NPO 0603200403232 C3,6 076-10400014CAP-MCC 100N 10% X7R 0603200403233 C4,14,23 076-20900012CAP-MCC 2P .25P NPO 0603200403231 C16 076-22000012CAP-MCC 22P 5% NPO 0603200403231 C15 076-27000012CAP-MCC 27P 5% NPO 0603200403231 C12 076-30900012CAP-MCC 3P .25P NPO 0603200403231 C18 076-33000012CAP-MCC 33P 5% NPO 0603200403231 C19 076-47000012CAP-MCC 47P 5% NPO 0603200403231 C9 076-47900012CAP-MCC 4P7 .25P NPO 0603200403231 C5 076-56000012CAP-MCC 56P 5% NPO 0603200403231 C8 076-80900012CAP-MCC 8P .25P NPO 0603200403234 C10,11,13,17 080-00000028SAW RESONATOR 310MHZ200403231 SAW1 149-00000078TERMINAL BLOCK 340-021-11200403231 CN1 160-33800001INDUCTOR 330NH 10%200403231 L2 160-47700011INDUCTOR 47N 2% 0603 SMD200403231 L1 210117H10070TRS-NPN MPS H10 SMD200403232 Q1,2 211328H10324IC EM78P153S OTP-ROM SMD200403231 U1 220-00200200LED 3MM (GREEN DIFFUSED)200403231 LED1 241-10100003RES-TFC 100R 5% 1/10W0603200403231 R4 241-10200003RES-TFC 1K 5% 1/10W 0603200403233 R9,11,12 241-10300003RES-TFC 10K 5% 1/10W 0603200403231 R2 241-10500003RES-TFC 1M 5% 1/10W 0603200403231 R10 241-33100003RES-TFC 330R 5% 1/10W0603200403231 R8 241-47100003RES-TFC 470R 5% 1/10W 0603200403232 R3,6 241-68200003RES-TFC 6K8 5% 1/10W 0603200403232 R1,5 268000H10009DRY REED SWITCH HYR1532200403231 REED SWITC H 283-00000026SLIDE SWITCH (MS12D16)200403231 SW2 283-00000041TACT SWITCH TC-2402-X200403231 SW1 403011H10331SPRING CONTACT (+VE)200403231 403011H10332SPRING CONTACT (-VE)200403231
1 2 34 ABCD 4 3 2 1 D CBA Title Number Revision Size A4 Date: 2-Apr-2004 Sheet of File: C:\DS11-FCC.SCH Drawn By: R1 6K8 R2 10K R4 10P R3 470R R56K8 R7 * SAW1 310MHz PCB2 L1 47N PCB1 C1 * C3 10P C54P7 C6 100R C4 100N Q1 H10 3V C8 56P C7 * C947P C10 8P C1222P C134P7 C11 8P Q2H10 R6 470R C14100N 3V C1522P C16 2P C17 8P RFO ANTENNA C19 33P C18 3P C20 * C21 * L2 0.33u P50 1 P67 2 P66 3 VDD 4 GND 11 P53 12 P52 13 P51 14 P65 5 P64 6 P63 7 P62 8 P61 9 P60 10 U1 78P153S RFO +3V C23 0.1u R12 1K R11 1K R10 1M SW1 (TEMPER SWITCH) SW2 (DELAY MIN / MAX) R9 1K R8 330R LED1 3MM RS DOOR / WINDOW SENSOR (310MHz) REED SWITCH (INT) CN1 BATT1 1.5V AAA BATT2 1.5V AAA C22 2u2 +3V 851001H12073 C24 * R13 * R14 * R15 * Q3* +3V NOTE :ALL UNSPECIFIED RESISTORS AND CAPACITORS ARE USE 0603 SMD PCB . 042010H11150A
Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R APPLICANT X-10 USA, Inc. 19823, 58 th Place S. Kent, WA 98032 MANUFACTURER X-10 Electronics Shenzhen Co. Ltd. X-10 Building Labour Industrial District Shenzhen, Xixiang, Bao An Guang Dong, China, 518102 TEST SPECIFICATION: FCC Rules and Regulations Part 15, Subpart C, Para. 15.231 TEST PROCEDURE: ANSI C63.4:2001 TEST SAMPLE DESCRIPTION BRANDNAME: X-10 MODEL: DS11A TYPE: Pulsed Transmitter POWER REQUIREMENTS: 3 VDC via (2) “AAA” Batteries FREQUENCY OF OPERATION: 310 MHz TESTS PERFORMED Para. 15.231(a), Radiated Emissions, Fundamental and Harmonics Para. 15.231(b), Radiated Emissions, Spurious Case Para. 15.231(b), Duty Cycle Determination Para. 15.231(c), Occupied Bandwidth REPORT OF MEASUREMENTS Applicant: X-10 (USA), Inc. Device: Pulsed Transmitter FCC ID: B4S-DS11A Power Requirements: 3 VDC via (2) “AAA” Batteries Applicable Rule Section: Part 15, Subpart C, Section 15.231 Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R REPORT OF MEASUREMENTS (continued) TEST RESULTS 15.231 (a): This device is used as a remote control transmitter. 15.231 (a)(1) & The transmitter is automatically operated. 15.231 (a)(3): The transmitter does not perform periodic transmissions. 15.231 (b): The fundamental field strength did not exceed 5833 FV/M (Average) at a test distance of 3 meters. In addition, the requirements of section 15.35 for averaging pulsed emissions and for limiting peak emissions were met. The field strength of harmonic and spurious emissions did not exceed 583 FV/M (AVERAGE). DETERMINATION OF FIELD STRENGTH LIMITS The field strength limits shown below are found in Section 15.231. Frequency Limit F1 = 260 3750 = L1 Fo = 310 Lo F2 = 470 12500 = L2 The formula below was utilized to determine the limits: Limit = L1 + [(Fo-F1)(L2-L1)/(F2-F1)] Solving yields: Fundamental Limit = 5833 FV/M (AVERAGE) @ 3 Meters Harmonic Limit = 583 FV/M (AVERAGE) @ 3 Meters Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R DUTY CYCLE DETERMINATION The unit’s RF output was directly coupled to the input of the spectrum analyzer. The analyzer was set for a frequency span of 0Hz. The sweep time was then adjusted in order to display one full pulse train. The transmitter on time was then summed and compared to the time for one full cycle in order to obtain the duty cycle. (See plots for additional information) Transmitter On Time = 30 milliseconds (maximum) Transmitter Cycle Time = 114 milliseconds Transmitter Duty Cycle = 30 % CALCULATION: 1 Large Pulse = 9.0 milliseconds 42 x 500 Fs (small pulse) = 21 milliseconds 21+9 = 30 milliseconds Duty Cycle (30/100) = 30 % Correction Factor = 20 log(0.30) = -10.4 dB Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS Due to the nature of the emissions being measured, care was taken to ensure that the resolution bandwidth of the spectrum analyzer was adequate to provide accurate measurements. The following formula was utilized: Setting pulse desensitization equal to zero and utilizing the minimum observed pulse width of 500 Fs yields a minimum required bandwidth of 1333 Hz. FCC specified bandwidths of 100 kHz and 1MHz were utilized below and above 1GHz, respectively. GENERAL NOTES 1. All readings were taken utilizing a peak detector function at a test distance of 3 meters. 2. The duty cycle was applied to the peak readings in order to determine the average value of the emissions. 3. The frequency range was scanned from 30 MHz to 3.1 GHz. All emissions not reported were more than 20 dB below the specified limit. Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R EQUIPMENT LIST FCC 15.231 Transmitter Testing EN Type Manufacturer Description Model No. Cal Date Due 067 Open Area Test Site Retlif 3 Meter RNY 10/1/2003 10/1/2006 128 Double Ridged Guide Electro-Mechanics 1 GHz - 18 GHz 3105 6/13/2003 6/13/2004 133 Broadband Pre-Amplifier Electro-Metrics 10 kHz - 1 GHz, 26dB BPA-1000 6/12/2003 6/12/2004 141 Spectrum Analyzer Hewlett Packard 100 Hz - 40 GHz 8566B 1/26/2004 7/26/2004 141A Graphics Plotter Hewlett Packard N/A 7470A 2/9/2004 2/9/2005 141B Quasi-Peak Adaptor Hewlett Packard 100 Hz - 1 GHz 85650A 1/26/2004 7/26/2004 206B 6.0 dB Attenuator Texscan 0 - 1.0 GHz FP-50 - 6 dB 6/12/2003 6/12/2004 543 Preamplifier Hewlett Packard 1.0 GHz - 26.5 GHz 8449B 7/24/2003 7/24/2004 617 Interference Analyzer Electro-Metrics 10 kHz - 1 GHz EMC-30 9/30/2003 9/30/2004 Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R FCC 15.231(b) RADIATED EMISSIONS, FUNDAMENTAL & SPURIOUS CASE (See separate e-file named Refundharm.pdf and REspur.pdf) Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R FCC 15.231(c) OCCUPIED BANDWIDTH (See separate e-file named occbw.pdf) Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R FCC 15.231(c) DUTY CYCLE (See separate e-file named dutycycle.pdf) Test Report No. R-10346-1 FCC ID: B4S-DS11A Retlif Testing Laboratories R Test Setup Photograph
795 Marconi Ave. · Ronkonkoma, New York · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 310 MHz - 310 MHz | - |

Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video System
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video Receiver
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter