Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Initializing Motion DetectorsRemove the cover on the front of the Motion Detector and install2 AAA alkaline batteries in the compartment. Replace the cover.Press and hold the TEST button on the back of the MotionDetector for a second and then release it. This initializes theMotion Detector and picks a random code that is used when it isregistered with the Console. ENTER PIN12:00 am****12:00 am 1. INSTALL Entering the PIN clears the top line and shows * for each number entered. Thedefault PIN is 0000, you’ll find out later how you can change this, but for now press0000 on the keyboard under the Console’s flip up lid.This takes you to the first level of the menu at step 1. This is the INSTALLATIONlevel. The display looks like this:Press OK and the display looks like this:Registering the Motion Detector with the Console.Press either of the Console’s 2 Menu up/down buttons (to the right of the display).The display then shows ENTER PIN (Personal Identification Number) in the topline. 1. INSTALLZONE Installing the Motion Detector• Attach the Motion Detector to a wall at a height of 5 to 6 ft. using the mounting bracket and screws provided.Note: The Motion Detector has a special lens that ‘looks’ downwards. It must therefore be mounted to face outwards horizontally, i.e. do not ‘aim’ the sensordownwards. • Set the slide switch (on the back) to position 1 for instant triggering for maximum sensitivity or position 2 to trigger only after two movements have been sensed. M O T I O N D E T E C T O R 5-6ft 30-40ft 90 ̊ Testing the Motion Detector• Set the slide switch on the Motion Detector to position 1. • Press and hold the TEST button for about a second. The LED flashes twice when you release it. • Wait 20 seconds for the Motion Detector to settle.• Walk in front of the Motion Detector. The indicator LED lights each time it senses movement. Check thecoverage area and reposition the sensor as required. • Press the TEST button to return to normal operating mode.Note: The Motion Detector will automatically return to normal operating mode after about 2 minutes. Battery ReplacementIf any zone shows LOW BATT on the Console’s display, the Motion Detector forthat zone will need its batteries replacing. Also, if a zone has not reported in duringthe last four hours, the display will show PROBLEM. This is most likely caused bydead batteries.As long as the batteries have not completely failed they may be replaced with freshbatteries without the need to reinstall the Motion Detector. After removing the oldbatteries fresh batteries must be fitted within 30 seconds to ensure that the securitycode is retained.To test the Motion Detector:Once the batteries have been replaced, the Motion Detector should be tested asfollows:• Make sure the system is NOT armed.• Press the TEST button on the back of the Motion Detector. The Console chimes to acknowledge and the zone # is displayed on the LCD. FCC StatementThis equipment generates and uses radio frequency energy, and if not installed andused properly, that is, in strict accordance with the manufacturers instructions, maycause interference to radio and television reception. It has been type tested and foundto comply with the limits for remote control security devices in accordance with thespecifications in Sub-Parts B and C of Part 15 of FCC Rules , which are designed to provide reasonable protection against such interference in a residential installation.However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause interference to radio or television recep-tion, which can be determined by unplugging the equipment, try to correct theinterference by one or more of the following measures.• Reorient the antenna of the radio/TV experiencing the interference.• Relocate the Console with respect to the radio/TV. • Move the Console away from the radio/TV.• Plug the Console into an outlet on a different electrical circuit from the radio/TV experiencing the interference. If necessary, consult your local RadioShack store for additional suggestions. Motion Detector Cat. No 49-1003 The plug ‘n power Supervised Security System Cat. No 49-1000 includes a SecurityConsole with an automatic dialer that calls neighbors or friends in the event of abreak in. A battery powered RF Door/Window Sensors and battery powered RFMotion Detector to trigger the alarm, and an RF and Keychain Remote control forarming and disarming the system. All sensors and remotes incorporate randomdigital security coding.The system may be configured with any combination of the following items:• Up to 16* Keychain Security Remotes with arm/disarm and panic functions, and buttons to control security lights in and around the home. • Up to 32* magnetic switch operated wireless Door/Window Sensors.• Up to 32* wireless PIR Motion Detectors.• Additional plug ‘n power Home Automation modules such as plug-in lamp and appliance modules and wired-in replacement wall switches can be added to thesystem (one Lamp Module included). This manual for the 49-1000 system describes the installation process for thesecurity elements of the system, and should be referred to as a supplement to thisinstruction booklet.* Note: Door/Window Sensors and Motion Detectors may be added in any combination up to a total of 32. RadioShack Corporation, Ft. Worth, TX 76102.
TAMPER SWITCH/TEST SWITCH PIR MCU EM78P153S 310MHz RFTRANSMITTER BLOCK DIAGRAM FOR Motion SensorModel MS17A (49-1003) 310MHz
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Wireless Motion Detector Cat. No. 49-1003 FCC ID: B4S-MS17A MS17A (49-1003) Motion Detector rating label 2:1 4/13/04 Custom Manufactured in China for RadioShack Corporation, Ft. Worth, TX 76102 For use with plug 'n power ® Security System, Cat. No. 49-1000. Use two AA alkaline batteries. FOR INDOOR USE ONLY. No user serviceable parts inside. 1 2 Test
X-10 Model MS17A Operational Description The model MS17A is a motion detection sensor sensor used with a wireless home alarm system. The device is placed at a convenient location by the homeowner to detect motion. When motion is detected the 310 MHz pulsed RF transmitter inside the MS17A transmits its own identifying pulse code to the alarm receiver. If the alarm system is armed an alarm condition will then occur.
MS17APIR MOTION DETECTOR SLIDE SWITCH1.000 BATTERY DOOR1.000 LEN CLIP1.000 PIR LENS1.000 TOP CABINET1.000 BOTTOM CABINET1.000 RUBBER KEYPAD1.000 SCREW-PPTT M2.6X8 MS/ZP4.000 SCREW-PWB M2.6X42.000 STANDARD M4 NUT1.000 SLIDE SWITCH CONTACT1.000 SPRING CONTACT +1.000 SPRING CONTACT -1.000 851001H12013PCB ASSY, PIR MAIN1.000 042010H11255APCB1.000 057-10000029CAP-E 10U 20% 16V2.000C31,33 057-10900001CAP-E 1U 20% 50V2.000C34,35 076-10000012CAP-MCC 10P .25P NPO 06031.000C3,6 076-10200014CAP-MCC 1N 10% X7R 06032.000C32,36 076-10400014CAP-MCC 100N 10% X7R 06033.000C4,14,23 076-20900012CAP-MCC 2P .25P NPO 06031.000C16 076-22000012CAP-MCC 22P 5% NPO 06032.000C12,15 076-30900012CAP-MCC 3P .25P NPO 06031.000C18 076-33000012CAP-MCC 33P 5% NPO 06031.000C19 076-47000012CAP-MCC 47P 5% NPO 06031.000C9 076-47900012CAP-MCC 4P7 .25P NPO 06032.000C5,13 076-56000012CAP-MCC 56P 5% NPO 06031.000C8 076-80900012CAP-MCC 8P .25P NPO 06034.000C10,11,13,17 080-00000028SAW RESONATOR 310MHZ1.000SAW1 160-33800001INDUCTOR 330NH 10%1.000L2 160-47700011INDUCTOR 47NH 2% 0603 SMD1.000L1 210-00000000TRS-PNP 2N3906 SMD2.000Q3,4 210117H10070TRS-NPN MPS H10 SMD2.000Q1,2 211328H10324IC EM78P153S OTP-ROM SMD1.000U2 211328H10332IC TLC27L4 OPAMP1.000U1 212107H10000DIODE-SI 1N41484.000D1-4 220-00200200LED 3MM (GREEN DIFFUSED)1.000LED1 241-10100003RES-TFC 100R 5% 1/10W 06031.000R3 241-10300003RES-TFC 10K 5% 1/10W 06034.000R2,31,32,34 241-10400003RES-TFC 100K 5% 1/10W 06034.000R42,44,45,47 241-10500003RES-TFC 1M 5% 1/10W 06033.000R36,37,39 241-22300003RES-TFC 22K 5% 1/10W 06031.000R43 241-22500003RES-TFC 2M2 5% 1/10W 06031.000R38 241-30300003RES-TFC 30K 5% 1/10W 06031.000R46 241-33100003RES-TFC 330R 5% 1/10W 06031.000R40 241-33500003RES-TFC 3M3 5% 1/10W 06031.000R33 241-47100003RES-TFC 470R 5% 1/10W 06032.000R3,6 241-47300003RES-TFC 47K 5% 1/10W 06031.000R35 241-68200003RES-TFC 6K8 5% 1/10W 06032.000R1,5 260201H10001PYRO DETECTOR LH1 9581.000PIR
1 2 3 4 56 ABCD 6 5 4 3 2 1 D CBA 11 851001H12013 A 2-Apr-2004 D:\IAN\PI RSECFA.SCH Title: Number: Date: File: Revision: Sheet of X10 Security PIR Ian Wong Drawn by: 32 1 411 U1ATLC27L4 56 7 U1BTLC27L4 10 9 8 U1CTLC27L4 1213 14 U1DTLC27L4 R333M3 R3410K C32 1nF +3V R3547K C341uFC351uF D1D2 R361MR371M +3V R38 2M2 C36 1nF D3D4 R391M PIR R3110KR3210K +3V VDD 4 VSS 11 P62 8 P64 6 P65 5 P53 12 P52 13 P51 14 P50 1 P67 2 P66 3 P61 9 P60 10 P63 7 U2EM78P153E/S SW1TEST SW2 TAMPER KNOCK C3110uF +3V LED1 GREEN R40330R R41 * Q33906 +3V R42100K R4322KR44100K BATTAA x2 C38 100uF C3310uF C37 100nF C1* R16K8 R2 10K R3 470R R4100R R56K8 R6 470R R7 * C21 * SAW1 Q1 H10 C20 * C4100nF C54p7 C610p C7 * C8 56p C947p C108p C118p C1222p C134p7 C14100nF C1522p C162PC178P C183PC1933p C3 10p L147n +3V Q2H10 L2 330n PCB1 PCB2 ANTENNA SW3 DOUBLE Q43906 R45100K R4630K(TBD)R47100K 3MM 310MHz
Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R APPLICANT X-10 USA, Inc. 19823, 58 th Place S. Kent, WA 98032 MANUFACTURER X-10 Electronics Shenzhen Co. Ltd. X-10 Building Labour Industrial District Shenzhen, Xixiang, Bao An Guang Dong, China, 518102 TEST SPECIFICATION: FCC Rules and Regulations Part 15, Subpart C, Para. 15.231 TEST PROCEDURE: ANSI C63.4:2001 TEST SAMPLE DESCRIPTION BRANDNAME: X-10 MODEL: KR31A TYPE: Pulsed Transmitter POWER REQUIREMENTS: 6 VDC via (2) CR2016 Lithium Batteries FREQUENCY OF OPERATION: 310 MHz TESTS PERFORMED Para. 15.231(a), Radiated Emissions, Fundamental and Harmonics Para. 15.231(b), Radiated Emissions, Spurious Case Para. 15.231(b), Duty Cycle Determination Para. 15.231(c), Occupied Bandwidth REPORT OF MEASUREMENTS Applicant: X-10 (USA), Inc. Device: Pulsed Transmitter FCC ID: B4S-KR31A Power Requirements: 6 VDC via (2) CR2016 Lithium Batteries Applicable Rule Section: Part 15, Subpart C, Section 15.231 Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R REPORT OF MEASUREMENTS (continued) TEST RESULTS 15.231 (a): This device is used as a Remote Control/Security device. 15.231 (a)(1) & The transmitter is manual operated. 15.231 (a)(3): The transmitter does not perform periodic transmissions. 15.231 (b): The fundamental field strength did not exceed 5833 FV/M (Average) at a test distance of 3 meters. In addition, the requirements of section 15.35 for averaging pulsed emissions and for limiting peak emissions were met. The field strength of harmonic and spurious emissions did not exceed 583 FV/M (AVERAGE). DETERMINATION OF FIELD STRENGTH LIMITS The field strength limits shown below are found in Section 15.231. Frequency Limit F1 = 260 3750 = L1 Fo = 310 Lo F2 = 470 12500 = L2 The formula below was utilized to determine the limits: Limit = L1 + [(Fo-F1)(L2-L1)/(F2-F1)] Solving yields: Fundamental Limit = 5833 FV/M (AVERAGE) @ 3 Meters Harmonic Limit = 583 FV/M (AVERAGE) @ 3 Meters Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R DUTY CYCLE DETERMINATION The unit’s RF output was directly coupled to the input of the spectrum analyzer. The analyzer was set for a frequency span of 0Hz. The sweep time was then adjusted in order to display one full pulse train. The transmitter on time was then summed and compared to the time for one full cycle in order to obtain the duty cycle. (See plots for additional information) Transmitter On Time = 30 milliseconds (maximum) Transmitter Cycle Time = 121.2 milliseconds Transmitter Duty Cycle = 30 % CALCULATION: 1 Large Pulse = 9.0 milliseconds 42 x 500 Fs (small pulse) = 21.0 milliseconds 21+9 = 30 milliseconds Cycle Time = 121.2 milliseconds Duty Cycle (30/100) = 30 % Correction Factor = 20 log(0.30) = -10.4 dB Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS Due to the nature of the emissions being measured, care was taken to ensure that the resolution bandwidth of the spectrum analyzer was adequate to provide accurate measurements. The following formula was utilized: Setting pulse desensitization equal to zero and utilizing the minimum observed pulse width of 500 Fs yields a minimum required bandwidth of 1333 Hz. FCC specified bandwidths of 100 kHz and 1MHz were utilized below and above 1GHz, respectively. GENERAL NOTES 1. All readings were taken utilizing a peak detector function at a test distance of 3 meters. 2. The duty cycle was applied to the peak readings in order to determine the average value of the emissions. 3. The frequency range was scanned from 30 MHz to 3.1 GHz. All emissions not reported were more than 20 dB below the specified limit. Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R Equipment List FCC 15.231 Transmitter Testing EN Type Manufacturer Description Model No. Cal Date Due 067 Open Area Test Site Retlif 3 Meter RNY 10/1/2003 10/1/2006 128 Double Ridged Guide Electro-Mechanics 1 GHz - 18 GHz 3105 6/13/2003 6/13/2004 133 Broadband Pre-Amplifier Electro-Metrics 10 kHz - 1 GHz, 26dB BPA-1000 6/12/2003 6/12/2004 141 Spectrum Analyzer Hewlett Packard 100 Hz - 40 GHz 8566B 1/26/2004 7/26/2004 141A Graphics Plotter Hewlett Packard N/A 7470A 2/9/2004 2/9/2005 141B Quasi-Peak Adaptor Hewlett Packard 100 Hz - 1 GHz 85650A 1/26/2004 7/26/2004 206B 6.0 dB Attenuator Texscan 0 - 1.0 GHz FP-50 - 6 dB 6/12/2003 6/12/2004 543 Preamplifier Hewlett Packard 1.0 GHz - 26.5 GHz 8449B 7/24/2003 7/24/2004 617 Interference Analyzer Electro-Metrics 10 kHz - 1 GHz EMC-30 9/30/2003 9/30/2004 Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R FCC 15.231(b) RADIATED EMISSIONS, FUNDAMENTAL & SPURIOUS CASE (See separate e-file named Refundharm.pdf and REspur.pdf) Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R FCC 15.231(c) OCCUPIED BANDWIDTH (See separate e-file named occbw.pdf) Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R FCC 15.231(c) DUTY CYCLE (See separate e-file named dutycycle.pdf) Test Report No. R-10346-3 FCC ID: B4S-KR31A Retlif Testing Laboratories R Test Setup Photograph
795 Marconi Ave · Ronkonkoma, New York · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 310 MHz - 310 MHz | - |

Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video System
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video Receiver
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter