Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
The FWMD Motion Detector sends Wireless Radio Frequency (RF) signals to a Black&Decker Messenger Hub FWMH). The Hub then passes the signals onto your house wiring to turn on lights, appliances, or Freewire wireless cameras around your home. You plug your lights and appliances into Freewire Modules (sold separately). You can set the Motion Detector to turn the lights or cameras off after motion stops. You can set this for a preset time of 1, 2, 4, 8 minutes etc., (see below for more details). You can set the unit to work at all times or only at night. Installation: Remove the screw from the bottom of the FWMD Motion Detector. Remove the battery cover and install two AAA alkaline batteries. Observe polarity. Leave the cover off for now. Plug in a Messenger Hub (FWMH, sold separately) and set it to Housecode A, and Unit Code 1. Plug a lamp into a Freewire Lamp Receiver (sold separately) and set it to Housecode A and Unit Code 1. Plug the module into any AC outlet. Synchronize the Motion Detector to work with the Hub: Set the Hub to Learn. Press the Synchronize button on the Motion Detector. The green indicator on the Hub flashes. Set the Hub back to Run. To test the Motion Detector: Press the Synchronize button once. The Motion Detector transmits the “device ON” RF signal and its red light flashes. Press the Synchronize button once again. The Motion Detector transmits the “device OFF” RF signal and its red light flashes. If you set a Hub and a Lamp Receiver to A1 they will both turn on and off when you repeatedly press the Synchronize button on the Motion Detector. Place the Motion Detector on a shelf or mount it on a wall at least 6 feet above the ground. Let it settle for a minute and then walk past it. The lamp connected to any Lamp Receiver set to A1, or a camera set to A1 turns on. The light or camera turns off a short time later as long as no motion has been detected. The default time is 1 minute but you can change this (see below for more details). You can now screw the Motion Detector to a wall and replace the battery cover. To change the Unit Code that the Motion Detector transmits: Turn its dial to any number (1-16). To change the delay after motion is detected before an OFF code is transmitted: Turn the dial on the Motion Detector to the desired setting: 0 (no off code sent), 1 minute, 2 minutes, 4 minutes, 8 minutes, 16 minutes, 32 minutes, 64 minutes, 128 minutes. 256 minutes. To change when the Motion Detector detects motion: Set the switch inside the battery compartment to “24Hr” if you want the Motion detector to detect motion at all times. Set the switch to “Night” if you only want it to detect motion when its dark (be sure to place the unit in a place where it can see if its dark outside, and don’t place it near the light that it turns on when it detects motion. Dusk/Dawn sensing: If you set the “off delay” to 0 AND set the Motion Detector to only work when its dark, it will not detect any motion at all, but will instead turn on a light when it gets dark and turn it off when it gets light. The light it controls it set by the position of its Unit Code dial (1-16) and the setting of the Housecode dial on the Hub (A-P). NOTES: After replacing batteries, and after a transmission, you need to wait 30 seconds before the Motion Detector will see any motion. The default time after which an OFF code is sent is 1 minute. When the Motion Detector turns on a camera, other cameras in a group of 3 turn off, but you might not want the Motion Detector to turn cameras off after motions stops, best to set the off delay to 0 minutes when using the Motion Detector with cameras. If the Hub is set to Learn, and the Motion Detector sees motion, it will synchronize itself to the Hub, i.e. you won’t need to press its Synchronize button to Synchronize it. Set-Up and Operating Instructions for FWMD Indoor/Outdoor Motion Detector FWMD-10/03 FCC CAUTION: THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. NOTE: NO CHANGES OR MODIFICATIONS MAY BE MADE TO THE UNITS. ANY CHANGES MADE TO THE UNITS WILL VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
“SYNCHRONIZE”BUTTON SLIDESWITCH PIR FWMD MCU LIGHT SENSOR 418MHz RFTRANSMITTER BLOCK DIAGRAM FOR FWMD
MOTION DETECTOR MODEL FWMD BLACK & DECKER (U.S.) INC., TOWSON, MD 21286 MADE IN CHINA QUESTIONS: 1-800-54-HOW-TO THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. NO USER SERVICEABLE PARTS INSIDE. USE TWO AAA ALKALINE BATTERIES. FOR INDOOR/OUTDOOR USE. FOR USE WITH FREEWIRE™ SYSTEM ONLY. FCC ID: B4SFWMD Black & Decker FWMD rating label 2:1 10/20/03
FWMD Operational Description The FWMD is a 418 MHz pulsed RF transmitter which is activated by a motion Detector. The transmitter sends a code to the Messenger Hub which in turn activates the appropriate appliances(lights, cameras, etc) . The internal MCUs receive information from the motion detector and convert the information into a pulse code. The pulse code is then sent to the 418 MHz RF transmitter and is used to pulse modulate the 418 MHz carrier.
1 2 3 4 5 6 78 ABCD 8 7 6 5 4 3 2 1 D CBA Title Number Revision Size A3 Date: 17-Oct-2003 Sheet of File: A:\FWMD1.SCH Drawn By: P50 1 P67 2 P66 3 VDD 4 GND 11 P53 12 P52 13 P51 14 P65 5 P64 6 P63 7 P62 8 P61 9 P60 10 U1 EM78P153S C9 10u C13 1u C10 100N P1 LHI958 R1675K U2A TLC27L2CP R174K7 R181M R1910M C142N2 U2B * R2156KR201M PIR RFO R136K8 SAW1 418MHz R1410K Q33356 R15150R C24P7 C31P5 C8 * L2 47N C5 100N VCC C410P C15100N L1 330N C656P L_S R8 470K R10 100K R112M2 R121M R9 68K Q13904 Q2 3904 CDS1A9001 VCC UNIT CODE DELAY TIMER D1-4 BAW56 R4-747K VCC P50P51P52P53 STB2STB1 SYN KEY1 SYNCHRONIZE SW1 24Hr / NIGHT R1 330R LED1 3MM RED VCC BATT2 1.5V/AAA BATT1 1.5V/AAA C1 10u P50 SW1 L_S P51 RFO EXT_T P52P53 STB2STB1 SYN C1247u SCHEMATIC FOR B&D MOTION DETECTOR (FWMD) D5 1N4148 D6 1N4148 SW1 PIR R226K8 R230R Q43356 R24 100R VCC C1715P C1910P C21 3P C164P7 C184P7 C2022P ANT90MM C22 100N C23 100N EXT_T R294M7 C24 100N D7 1N4148 VCC C25100N R304M7 R31 470K R32 470K 32 84 15 6 7 851001H11951
Test Report No. R-10116-1 FCC ID: B4SFWMD APPLICANT X-10 USA, Inc. 19823, 58 th Place S. Kent, WA 98032 MANUFACTURER X-10 Electronics Shenzhen Co. Ltd. X-10 Building Labour Industrial District Shenzhen, Xixiang, Bao An Guang Dong, China, 518102 TEST SPECIFICATION: FCC Rules and Regulations Part 15, Subpart C, Para. 15.231 TEST PROCEDURE: ANSI C63.4:2001 TEST SAMPLE DESCRIPTION BRANDNAME: X-10 USA, Inc. MODEL: FWMD TYPE: Pulsed Transmitter POWER REQUIREMENTS: 2 "AAA" Batteries FREQUENCY OF OPERATION: 418 MHz TESTS PERFORMED Para. 15.231(b), Radiated Emissions, Fundamental and Harmonics Para. 15.231(b), Radiated Emissions, Spurious Case Para. 15.35, Duty Cycle Determination Para. 15.231(c), Occupied Bandwidth Test Report No. R-10116-1 FCC ID: B4SFWMD REPORT OF MEASUREMENTS Applicant: X-10 (USA), Inc. Device: Pulsed Transmitter FCC ID: B4SFWMD Power Requirements: 2 "AAA" Batteries Applicable Rule Section: Part 15, Subpart C, Section 15.231 TEST RESULTS 15.231 (a): This device is used as a security transmitter. 15.231 (a)(1) & The transmitter is automatically operated and ceases transmission within 5 15.231(a)(2): seconds after deactivation. 15.231 (a)(3): The transmitter does not perform periodic transmissions. 15.231 (b): The fundamental field strength did not exceed 10,333 μV/M (Average) at a test distance of 3 meters. In addition, the requirements of section 15.35 for averaging pulsed emissions and for limiting peak emissions were met. The field strength of harmonic and spurious emissions did not exceed 1,033 μV/M (AVERAGE). DETERMINATION OF FIELD STRENGTH LIMITS The field strength limits shown below are found in Section 15.231. Frequency Limit F1 = 260 3750 = L1 Fo = 418 Lo F2 = 470 12500 = L2 Test Report No. R-10116-1 FCC ID: B4SFWMD REPORT OF MEASUREMENTS (continued) The formula below was utilized to determine the limits: Limit = L1 + [(Fo-F1)(L2-L1)/(F2-F1)] Solving yields: Fundamental Limit = 10,333 μV/M (AVERAGE) @ 3 Meters Harmonic Limit = 1,033 μV/M (AVERAGE) @ 3 Meters DUTY CYCLE DETERMINATION The unit’s RF output was directly coupled to the input of the spectrum analyzer. The analyzer was set for a frequency span of 0Hz. The sweep time was then adjusted in order to display one full pulse train. The transmitter on time was then summed and compared to the time for one full cycle in order to obtain the duty cycle. Transmitter On Time = 43.7 milliseconds (maximum) Transmitter Cycle Time = 115.5 milliseconds Transmitter Duty Cycle = 36.4 % See separate e-file plots named dutycycle.pdf for additional information. Test Report No. R-10116-1 FCC ID: B4SFWMD SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS Due to the nature of the emissions being measured, care was taken to ensure that the resolution bandwidth of the spectrum analyzer was adequate to provide accurate measurements. The following formula was utilized: Setting pulse desensitization equal to zero and utilizing the minimum observed pulse width of 650 μs yields a minimum required bandwidth of 1,026 Hz. FCC specified bandwidths of 100 kHz and 1 MHz were utilized below and above 1 GHz, respectively. GENERAL NOTES All readings were taken utilizing a peak detector function at a test distance of 3 meters. The duty cycle was applied to the peak readings in order to determine the average value of the emissions. The frequency range was scanned from 30 MHz to 4.18 GHz. All emissions not reported were more than 20 dB below the specified limit. Test Report No. R-10116-1 FCC ID: B4SFWMD EQUIPMENT LIST FCC Part 15, Subpart C, Paragraph 15.231 EN Type Manufacturer Description Model No. Cal Date Due Date 067 Open Area Test Site Retlif 3 Meter RNY 10/01/2003 10/01/2006 128 Double Ridged Guide Electro-Mechanics 1 GHz - 18 GHz 3105 06/13/2003 06/13/2004 133 Broadband Pre-Amplifier Electro-Metrics 10 kHz - 1 GHz, 26dB BPA-1000 06/12/2003 06/12/2004 141 Spectrum Analyzer Hewlett Packard 100 Hz - 40 GHz 8566B 07/23/2003 01/23/2004 141A Graphics Plotter Hewlett Packard N/A 7470A 03/05/2003 03/05/2004 141B Quasi-Peak Adaptor Hewlett Packard 100 Hz - 1 GHz 85650A 07/23/2003 01/23/2004 206B 6.0 dB Attenuator Texscan 0 - 1.0 GHz FP-50 - 6 dB 06/12/2003 06/12/2004 543 Preamplifier Hewlett Packard 1.0 GHz - 26.5 GHz 8449B 07/24/2003 07/24/2004 617 Interference Analyzer Electro-Metrics 10 kHz - 1 GHz EMC-30 09/30/2003 09/30/2004 767 Biconilog EMCO 26 - 2000 MHz 3142B 09/04/2003 09/04/2004 Test Report No. R-10116-1 FCC ID: B4SFWMD FCC 15.231(b) RADIATED EMISSIONS, FUNDAMENTAL & SPURIOUS CASE (See separate e-file named Refundharm.pdf & REspur.pdf) FCC 15.231©) OCCUPIED BANDWIDTH (See separate e-file named occbw.pdf) Test Report No. R-10116-1 FCC ID: B4SFWMD FCC 15.231©) DUTY CYCLE (See separate e-file named dutycycle.pdf) Test Report No. R-10116-1 FCC ID: B4SFWMD Test Setup Photograph
Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD APPLICANT X-10 USA, Inc. 19823, 58 th Place S. Kent, WA 98032 MANUFACTURER X-10 Electronics Shenzhen Co. Ltd. X-10 Building Labour Industrial District Shenzhen, Xixiang, Bao An Guang Dong, China, 518102 TEST SPECIFICATION: FCC Rules and Regulations Part 15, Subpart C, Para. 15.231 TEST PROCEDURE: ANSI C63.4:2001 TEST SAMPLE DESCRIPTION BRANDNAME: X-10 USA, Inc.MODEL: FWMD TYPE: Pulsed Transmitter POWER REQUIREMENTS: 2 "AAA" Batteries FREQUENCY OF OPERATION: 418 MHz TESTS PERFORMED Para. 15.231(b), Radiated Emissions, Fundamental and Harmonics Para. 15.231(b), Radiated Emissions, Spurious Case Para. 15.35, Duty Cycle Determination Para. 15.231(c), Occupied Bandwidth Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD REPORT OF MEASUREMENTS Applicant: X-10 (USA), Inc. Device:Pulsed Transmitter FCC ID: B4SFWMD Power Requirements: 2 "AAA" Batteries Applicable Rule Section:Part 15, Subpart C, Section 15.231 TEST RESULTS 15.231 (a):This device is used as a security transmitter. 15.231 (a)(1) &The transmitter is automatically operated and ceases transmission within 5 15.231(a)(2):seconds after deactivation. 15.231 (a)(3):The transmitter does not perform periodic transmissions. 15.231 (b):The fundamental field strength did not exceed 10,333 μV/M (Average) at a test distance of 3 meters. In addition, the requirements of section 15.35 for averaging pulsed emissions and for limiting peak emissions were met. The field strength of harmonic and spurious emissions did not exceed 1,033 μV/M (AVERAGE). DETERMINATION OF FIELD STRENGTH LIMITS The field strength limits shown below are found in Section 15.231. Frequency Limit F1=2603750=L1 Fo=418Lo F2=47012500=L2 Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD REPORT OF MEASUREMENTS (continued) The formula below was utilized to determine the limits: Limit = L1 + [(Fo-F1)(L2-L1)/(F2-F1)] Solving yields: Fundamental Limit= 10,333 μV/M (AVERAGE) @ 3 Meters Harmonic Limit= 1,033 μV/M (AVERAGE) @ 3 Meters DUTY CYCLE DETERMINATION The unit’s RF output was directly coupled to the input of the spectrum analyzer. The analyzer was set for a frequency span of 0Hz. The sweep time was then adjusted in order to display one full pulse train. The transmitter on time was then summed and compared to the time for one full cycle in order to obtain the duty cycle. Transmitter On Time=43.7 milliseconds (maximum) Transmitter Cycle Time=115.5 milliseconds Transmitter Duty Cycle=36.4 % See separate e-file plots named dutycycle.pdf for additional information. Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS Due to the nature of the emissions being measured, care was taken to ensure that the resolution bandwidth of the spectrum analyzer was adequate to provide accurate measurements. The following formula was utilized: Setting pulse desensitization equal to zero and utilizing the minimum observed pulse width of 650 μs yields a minimum required bandwidth of 1,026 Hz. FCC specified bandwidths of 100 kHz and 1 MHz were utilized below and above 1 GHz, respectively. GENERAL NOTES 1.All readings were taken utilizing a peak detector function at a test distance of 3 meters. 2.The duty cycle was applied to the peak readings in order to determine the average value of the emissions. 3.The frequency range was scanned from 30 MHz to 4.18 GHz. All emissions not reported were more than 20 dB below the specified limit. Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD EQUIPMENT LIST FCC Part 15, Subpart C, Paragraph 15.231 ENTypeManufacturerDescriptionModel No.Cal DateDue Date 067Open Area Test SiteRetlif3 MeterRNY10/01/200310/01/2006 128Double Ridged GuideElectro-Mechanics1 GHz - 18 GHz310506/13/200306/13/2004 133Broadband Pre-AmplifierElectro-Metrics10 kHz - 1 GHz, 26dBBPA-100006/12/200306/12/2004 141Spectrum AnalyzerHewlett Packard100 Hz - 40 GHz8566B07/23/200301/23/2004 141AGraphics PlotterHewlett PackardN/A7470A03/05/200303/05/2004 141BQuasi-Peak AdaptorHewlett Packard100 Hz - 1 GHz85650A07/23/200301/23/2004 206B6.0 dB AttenuatorTexscan0 - 1.0 GHzFP-50 - 6 dB06/12/200306/12/2004 543PreamplifierHewlett Packard1.0 GHz - 26.5 GHz8449B07/24/200307/24/2004 617Interference AnalyzerElectro-Metrics10 kHz - 1 GHzEMC-3009/30/200309/30/2004 767BiconilogEMCO26 - 2000 MHz3142B09/04/200309/04/2004 Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD FCC 15.231(b) RADIATED EMISSIONS, FUNDAMENTAL & SPURIOUS CASE (See separate e-file named Refundharm.pdf & REspur.pdf) Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD FCC 15.231©) OCCUPIED BANDWIDTH (See separate e-file named occbw.pdf) Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD FCC 15.231©) DUTY CYCLE (See separate e-file named dutycycle.pdf) Retlif Testing Laboratories R Test Report No. R-10116-1 FCC ID: B4SFWMD Test Setup Photograph
795 Marconi Ave · Ronkonkoma, New York · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 418 MHz - 418 MHz | - |

Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video System
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Audio/Video Receiver
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Color Camera
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter