Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 23 Rev.No 1.0 7SUMMARY: All tests according to CFR 47, Part 15, Paragraphs 15.207 and 15.209 were n - Performed The Equipment Under Test n - Fulfills the general requirements of CFR 47, Part 15, Paragraphs 15.207 and 15.209. _______________________ - TÜV PRODUCT SERVICE, INC. - Responsible Engineer: Jim Owen (EMC Engineer)
BACK OF CASE CASE TOP SIDE OF CASE NEAR HINGE SIDE OF CASE OPPOSITE CONDUIT FITTINGS SIDE OF CASE OPPOSITE HINGE SIDE OF CASE WITH CONDUIT FITTINGS VACS2000 WITH ANTENNA AND PC VACS2000 WITH PC
TI Main Board Side 1 TI main Board Side 2 TI main Board Side 2 with RFM removed TI RFM Board Side 1 TI RFM Board Side 2 with heatsink TI RFM Board Side 2 without heatsinks. Blue covers are potted components and cannot be removed. Closeup of 24 Vdc Supply and Relays Closeup of Fuse and EMI Filters Closeup of S251B RS232 and Relay Hookup Closeup of TIRIS S251B Reader VACS Interior #3
RF EXPOSURE STATEMENT: The EUT is categorically excluded from routine evaluation because it is a low power device.
TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 1 Rev.No 1.0 MEASUREMENT AND TECHNICAL REPORT HM ELECTRONICS 6675 Mesa Ridge Road San Diego, CA 92121-2937 DATE: 19 January 2001 This Report Concerns:Original Grant: XClass II Change: Equipment Type:Vehicle Access Control System, Model VACS2000 Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes: Defer until: No: X Company Name agrees to notify the Commission by:N/A of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes:*No: (*) FCC Part 15, Paragraphs 15.207 and 15.209 Report Prepared by: TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 619 546 3999 Fax: 619 546 0364 TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 2 Rev.No 1.0 TABLE OF CONTENTS Pages 1 GENERAL INFORMATION3 1.1Product Description3 1.2Related Submittal Grant10 1.3Tested System Details10 1.4Test Methodology10 1.6Part 2 Requirements10 2 SYSTEM TEST CONFIGURATION11 2.1Justification11 2.2EUT Exercise Software11 2.3Special Accessories11 2.4Equipment Modifications11 2.5Configuration of Tested System11 3 CONDUCTED MEASUREMENT EQUIPMENT/DATA12 4RADIATED MEASUREMENTEQUIPMENT/DATA18 4.1Field Strength Calculation22 5Signature Page23 TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 3 Rev.No 1.0 1 GENERAL INFORMATION 1.1Product Description Vehicle Access Control System, Model VACS2000 TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 10 Rev.No 1.0 1.2Related Submittal/Grant None 1.3Tested System Details The FCC IDs for all equipment, plus descriptions of all cables used in the tested system are: None 1.4Test Methodology Purpose of Test:To demonstrate compliance with the ANSI C63.4 setup. Test Performed:x1. Conducted Emissions, FCC Part 15.207 2. Radiated Emissions, EN55022: 1992 Class B limit, 30 - 1,000 MHz, 10 meters x3. Radiated Emission per FCC Part 15.209 4. Engineering evaluations 1.5Test Facility The open area test site and conducted measurement data were tested by: TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 619 546 3999 Fax: 619 546 0364 The Test Site Data and performance comply with ANSI 63.4 and are registered with the FCC, 7435 Oakland Mills Rd, Columbia Maryland 21046. All Measurement Data is acquired according to the content of FCC Measurement Procedure and ANSI C63.4, unless supplemented with additional requirements as noted in the test report. 1.6 Part 2 Requirements Direct sequence spread spectrum transmitters under Part 15 - not applicable. Frequency hopping transmitters under Part 15 - not applicable. Certification of scanning receivers - not applicable. Certification of transmitters operating within the 59 to 64 GHz band - not applicable. TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 11 Rev.No 1.0 2.SYSTEM TEST CONFIGURATION 2.1Justification The was initially tested for FCC emission in the following configuration: See Block Diagram. 2.2EUT Exercise Software None 2.3Special Accessories None 2.4Modification None 2.5Configuration of Tested System See Block Diagram. TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 12 Rev.No 1.0 3CONDUCTED MEASUREMENT TEST EQUIPMENT Emissions Test Conditions: CONDUCTED EMISSIONS The EQUIVALENT CONDUCTED EMISSIONS measurements were performed in the following test location : o - Test not applicable SR-3, Shielded Room, 12’ x 20’ x 8’, Metal Chamber Test Equipment Used : Model NumberProp. No.DescriptionManufacturerSerial No.Cal Date 9252-50-R-24-BNC457LISN, 50 μH /250 μH/50 Ω/0.25 μF Solar Electronics Co.94172005/01 ESHS 30459EMI Test ReceiverRohde & Schwarz832354/00411/01 CAT-2061620 dB AttenuatorMini-Circuits--* Remarks:(*) Verified internally. TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 13 Rev.No 1.0 4CONDUCTED EMISSION DATA HME ELECTRONICS See following page(s). TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 18 Rev.No 1.0 5RADIATED MEASUREMENT EQUIPMENT LIST Emissions Test Conditions: RADIATED EMISSIONS (Electric Field) The EQUIVALENT RADIATED EMISSIONS measurements were performed at the following test location : o - Test not applicable Test Site: Canyon Site Parking Lot, Carroll Canyon, San Diego Test Equipment Used : Model No.Property No.DescriptionManufacturerSerial NumberCal Date ESHS 30459EMI Test ReceiverRohde & Schwarz832354/00411/01 HFH2-Z2208Loop AntennaRohde & Schwarz880* Remarks:(*) Verified prior to use. TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 19 Rev.No 1.0 6RADIATED EMISSION DATA The following data lists the significant emission frequencies, measured levels, correction factor (which includes cable and antenna corrections), the corrected reading, and the limit. See following page(s). TÜV PRODUCT SERVICE 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone 858 546 3999 FAX 858 546 0364 Report No. 0466-03 (FCC ID: BYMBVACS2000) Page 22 Rev.No 1.0 6.1Field Strength Calculation If a preamplifier was used during the Radiated Emission Testing, it is required that the amplifier gain must be subtracted from the Spectrum Analyzer (Meter) Reading. In addition, a correction factor for the antenna , cable used an…
Text truncated - open the document above for the full version.
CONDUCTED Conducted Radiated Radiated
10040 Mesa Rim Road · San Diego, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1342 MHz - 0.1342 MHz | - |
Wireless Beltpack
Equipment Class
CBE - Citizens Band End User Devices
Remote Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Remote Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Nexeo AIO headset
Equipment Class
DTS - Digital Transmission System
Battery Charger
Equipment Class
DTS - Digital Transmission System