HME# 400518 Rev— 8/15/03 Wireless 6000 Wireless Drive-Thru Audio System Operating Instructions Table of Contents I. GENERAL.........................................................................................................................1 II. EQUIPMENT FUNCTIONS AND USE .........................................................................1 A. Base Station .....................................................................................................................................2 B. Headset .....................................................................................................................................4 C. Battery Charger................................................................................................................................7 III. WIRELESS 6000 OPERATION ......................................................................................8 A. Single-Lane Operation .....................................................................................................................8 B. Dual-Lane Operation .......................................................................................................................9 C. Internal Communication ..................................................................................................................9 D. Speed-Team Operation ....................................................................................................................9 E. Message Repeater Operation .........................................................................................................10 IV. EQUIPMENT CARE AND CLEANING ......................................................................11 A. Proper Handling.............................................................................................................................11 B. Cleaning ...................................................................................................................................11 V. IN CASE OF PROBLEMS .............................................................................................12 VI. SPECIFICATIONS.........................................................................................................15 VII. OPTIONAL EQUIPMENT ............................................................................................16 VIII. FCC NOTICE ..................................................................................................................16 List of Figures Figure Title Page 1 Wireless 6000 equipment ........................................................................................................1 2 Wireless 6000 Base Station with cabinet door open ...............................................................2 3 Wireless 6000 COMMUNICATOR ® ......................................................................................4 4 Communicator and headset .....................................................................................................4 5 Registration buttons and indicators .........................................................................................6 6 Communicator battery-release latch........................................................................................7 7 Batteries in charger .................................................................................................................7 8 Base station internal controls and connectors ....................................................................... 14 The HME logo and the word COMMUNICATOR ® are registered trademarks of HM Electronics, Inc. © Copyright HM Electronics, Inc. - August 2003 1 I. GENERAL The Wireless 6000 is a wireless audio system primarily for use at quick-service restaurants. II. EQUIPMENT FUNCTIONS AND USE Figure 1. Wireless 6000 equipment 2 A. Base Station The base station is the electronic heart of the Wireless 6000. It contains the circuitry through which all functions of the drive-thru audio system are channeled. External base station features are shown in Figure 2, and described on page 3. Its internal controls and connectors are shown in Figure 8 on page 14. A C B Figure 2. Wireless 6000 Base Station with cabinet door open 3 Base Station External Features Front — (See A on Figure 2.) • Four power supply lights are on when the base station has AC power. • “A” TALK light is on during channel-A transmission. • “B” TALK light is on during channel-B transmission. • VEHICLE PRESENT light is on when a vehicle is present in the drive-thru lane or when the system is in vehicle-detect override. • RECORD light is ON RED when the base station is ready to record red message for the message repeater, and blinking red while red message is being recorded. It is on GREEN when the base station is ready to record green message for the message repeater, and blinking GREEN while green message is being recorded. Bottom — (See B on Figure 2.) • PUSH FOR RECORD MODE button must be pushed IN and released once to prepare the base station to record red message for the message repeater, or pushed IN and released twice to record green message. Behind Front Door — (See C on Figure 2.) • MESSAGE REPEATER switches must be switched ON to use the message repeater, OFF when the message repeater is not being used. Instructions are given on the inside of the front door. • SPEED TEAM switch must be switched ON for speed-team operation, OFF for normal drive-thru operation • VEHICLE DETECTOR switch must be switched to OVERRIDE to disable vehicle detector; to reset vehicle detector, switch to OVERRIDE for 5 seconds, then switch back to NORMAL and leave for normal vehicle detection operation. • DIP switches at the top are used to control message audio routing to the speakers and Communicators. DIP switch settings are shown on the inside of the front door. • Nine level controls are used to set VAA level, Vehicle tone level, audio source levels at the grill …
Text truncated - open the document above for the full version.
___________________________________________________________________________________ ETSHandelsregister:Bankverbindung: Electronic Technology Systems Dr. Genz GmbHAmtsgericht Frankfurt/Oder HRB 5151Sparkasse Oder-Spree Storkower Strasse 38cGeschäftsführung: Dr. Dietmar GenzBLZ 170 550 50 D-15526 Reichenwalde b. Berlin Norbert KasparKto. Nr. 3105165974 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH - ETS - STORKOWER STRASSE 38c, D-15526 REICHENWALDE B. BERLIN Tel: 033631 888 000 FAX: 033631 888660 BZT ETS CERTIFICATION GMBH Mr. Dieter Griep / Mr. Andreas Herrmann Storkower Str. 38c 15526 Reichenwalde b. Berlin GERMANY IHR ZEICHEN / YOUR REF.IHR SCHREIBEN / YOUR INFORM.UNSER ZEICHEN / OUR REF. DATUM / DATE 09-09-2003 Subject:Application for TCB Certification Applicant: HM Electronics, Inc. Equipment: Wireless 6000 / COM 6000BP FCC ID: BYMCOM6000BP Dear Sirs, Submitted herewith, on behalf of HM Electronics, Inc., is an application for certification under FCC Rule 15 of the following equipment: Wireless 6000 / FCC ID: BYMCOM6000BP Attached are the 731Form, Confidentiality request letter, test report (TestRpt1=test data, TestRpt2=test plots), RF Exposure (SAR Measurement Report), FCC ID label and label location information, test setup photographs, internal and external photographs, operational description, part’s list, block diagrams, schematics, tune procedure information and user manual 1 and 2. Please note that this equipment is a part of a system consisting of a Base (FCC ID: BYMBASE6000) and the Com. In accordance with 0.459 of CFR 47 HM Electronics, Inc. hereby requests confidentiality of all Block Diagrams, Circuit Diagrams (Schematics), Parts List and Operational Description (see attached Confidentiality Request Letter) for the subject application. Should you have any questions or comments concerning the above, please contact the following e-mail addresses: [email protected]. Best Regards Jenifer Täubert Electronic Technology Systems Dr. Genz GmbH Storkower Strasse 38c 15526 Reichenwalde bei Berlin German y
June 17, 2003 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Request for Confidentiality HM Electronics, Inc. FCC ID: BYMCOM6000BP, BYMBASE6000 FCC Part 15 Certification Gentlemen, In accordance with 0.459 of CFR 47, HM Electronics, Inc. hereby requests confidentiality of all Schematics, Block Diagrams, and Operating Descriptions attached to the subject application. These documents contain detailed system and equipment description and related information about the product, which HM Electronics, Inc. considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, HM Electronics, Inc. considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, Thomas P. Riches Engineering Services Manager Ph. (858) 535-6098 Fx. (858) 535-6019 14110 Stowe Drive Poway, California 92064 Corporate Phone: (858) 535-6000 / Fax: (858) 452-7207
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 1 of 12 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 2 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 3 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 4 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 5 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 6 of 12
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 7 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 8 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 9 of 12
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 10 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 11 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 12 of 12
Applicant's declaration concerning Antenna Specification Date: 11 Aug. 03 · Ref.: KHR It's hereby declared that the HM Electronics COM6000 "Helena COM" fulfils the requirement in FCC test relating to the antenna type. The HM Electronics COM6000 "Helena COM" confirm to FCC recommendation with internal antenna type: Inverted F type antenna Integrated as wire tracks, being a part of the PCB Gain of the antenna is 0dBi (typ.). Frequency range is 2.400MHz to 2.483,5MHz On behalf of HM Electronics Inc. Sincerely Kurt Heick Rasmussen Project Manager RTX Telecom A/S RTX Telecom A/S Stroemmen 6 DK-9400 Noerresundby, Denmark Phone : +45 96 32 23 00 Fax : +45 96 32 23 10 VAT# : DK 17 00 21 47 Web : www.rtx.dk E-mail : [email protected]
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 15 / SUBPART C FCC ID:BYMCOM6000BP Test report no.: G0M20306-7968-P-15 FCC ELECTRONIC TECHNOLOGY SYSTEMSSTORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBHPHONE +49-33631-888 00 FAX +49-33631-888 66 ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 1 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1General information 1.1Notes 1.2Testing laboratory 1.3Details of approval holder 1.4Application details 1.5Test item 1.6Test standards 2Technical test 2.1Summary of test results 2.2Test environment 2.3Test equipment utilized 2.4General Test Procedure 3Test Results ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 2 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1General Information 1.1Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has Passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extractes from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 25.08.2003N. Kaspar DateETS-Lab.NameSignature Technical responsibility for area of testing: 25.08.2003Dr. Genz DateETSNameSignature ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 3 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 66 1.2.2Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 ACCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY:BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA A CCREDITEDCertificate Number: 1983-01 1.3Details of approval holder Name: HM Electronics, Inc. Street: 14110 Stowe Drive Town: 92064 Poway, CA Country: USA Telephone: +1 858 535 6098 Fax: +1 858 535 6019 Contact: Mr. Thomas P. Riches Telephone: +1 858 535 6098 E-mail: [email protected] ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 4 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4Application details Date of receipt of application: 25.06.2003 Date of receipt of test item: 25.06.2003 Date of test: 25.06.2003-01.07.2003 1.5Test item Description of test item: Wireless 6000 Type identification: COM 6000BP Serial number: Test model without serial number. Photos: See annex Technical data Frequency band: 2.4 – 2.4835GHz Frequency ( ch A): 2.401920 GHz Frequency (ch B): 2.441664 GHz Frequency (ch C): 2.481408 GHz TransmitterVnom Power (ch A) :Conducted: 17,62 dBm Power (ch B) :Conducted: 18,07 dBm Power (ch C) :Conducted: 17,95 dBm Vnom Antenna 1Vnom Antenna 2 Power (chA) :Radiated: 11,85 dBm Radiated: 13,02 dBm Power (ch B) :Radiated: 16,50 dBmRadiated: 19,14 dBm Power (ch C) :Radiated: 19,36 dBmRadiated: 19,55 dBm Antenna 1: integral(internal antenna)Antenna gain: 0 dBi Antenna 2: integral(internal antenna) Power supply : 3,8V DC Operating mode: duplex Type of modulation: FHSS ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 5 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH Manufacturer: (if applicable) Name: Street: Town: Country: Additional information: ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 6 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6Test standards Technical standard : FCC RULES PART 15 / SUBPART C § 15.247 2Technical test 2.1Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests performed. 2.2Test environment Temperature: 23 o C Relative humidity content: 20 ...75 % Air pressure: 86 ...103 kPa Details of power supply: 3,8 V DC Extrem conditions parameters:: test voltage - extrememin : V, AC max: V, AC ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 7 of 27 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3Test equipment utilized No.Measurement device:Type:Manufacturer: ETS 0001Test receiverESHS 10Rohde&Schwarz ETS 0002Test receiverESVPRohde&Schwarz ETS 0003Test receiverESVS 10Rohde&Schwarz ETS 0004Spectrum- and Network-AnalyzerFSMS 26Rohde&Schwarz ETS 0005Test receiverSMV 11MEB ETS 0006Test receiver systemSME 12MEB ETS 0007Spectrum analyzerPSA-65AAvcom ETS 0008AntennaLoop antennaSiemens ETS 0009AntennaLoop antennaMEB ETS 0010AntennaLoop antennaMEB ETS 0011Antennavan Veen/ FrameETS ETS 0012AntennaHK 116Rohde&Schwarz ETS 0013AntennaHL 223Rohde&Schwarz ETS 0014AntennaHL 025Rohde&Schwarz ETS 0015AntennaHL 025Rohde&Schwarz ETS 0016AntennaVHAPSchwarzbeck ETS 0017AntennaVHAPSchwarzbeck ETS 0018AntennaUHAPSchwarzbeck ETS 0019AntennaUHAPSchwarzbeck ETS 0020AntennaDP 21MEB ETS 0021AntennaDP 3MEB ETS 0022AntennaSAS-200/ 521A.H. Systeme / USA ETS 0023AntennaDP 1MEB ETS 0024Antenna mastAF 2MEB ETS 0025Antenna mastAF 2MEB ETS 0026TripodHeinrich Deisel ETS 002…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT SAR Compliance Test Report Test report no.: G0M20306-7968-S-1 SAR ELECTRONIC TECHNOLOGY SYSTEMSSTORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBHPHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-S-1Page 1 of 23 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1General information 1.1Notes 1.2Testing laboratory 1.3Details of approval holder 1.4 Manufacturer 1.5Application details 1.6Test item 1.7Test results 1.8Test standards 2Technical test 2.1Summary of test results 2.2Test environment 2.3Test equipment utilized 2.4Definitions 2.5Measurement system description 2.6Test system specification 2.7Measurement procedure 2.8Reference points 2.9Test positions 2.10Measurement uncertainty 3Tissue and system verification 3.1Tissue verification 3.2System verification 4Test Results 5References 6Appendix ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-S-1Page 2 of 23 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1General Information 1.1Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualification of all persons taking them. Tester: 16.07.2003N. Kaspar DateETS-Lab.NameSignature Technical responsibility for area of testing: 16.07.2003Dr. Genz DateETSNameSignature ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-S-1Page 3 of 23 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telephone : +49 33631 888 00 Fax: +49 33631 888 660 1.2.2Details of accreditation status ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY BLUETOOTH QUALIFICATION REVIEW BOARD INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number 1983-01 1.3Details of approval holder Name: HM Electronics, Inc. Street: 14110 Stowe Drive Town: 92064 Poway, CA Country: USA Telephone: +1 858 535 6098 Fax: +1 858 535 6019 Contact: Mr. Thomas P. Riches E-Mail: [email protected] 1.4Manufacturer: (if applicable) Name: Street: Town: Country: ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-S-1Page 4 of 23 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.5Application details Date of receipt of application: 25.06.2003 Date of receipt of test item: 25.06.2003 Date of test: 08.07.2003 - 09.07.2003 1.6Test item FCC ID: BYMCOM6000BP Description of test item: Wireless 6000 Type identification: COM 6000BP Serial number: without;Identical prototype Device category: DSS (Part 15 Spread Spectrum Transmitter) Technical data TX Frequency range: 2401,920 - 2481,408 MHz RX Frequency range: 2401,920 - 2481,408 MHz Max. Conducted RF output power : 18,01 dBm(63,2 mW) Power supply : 3,8 V DC rechargeable battery Antenna 1: integral Antenna 2: integral 1.7Test Results Max. SAR Measurement: 0.0955 W/kg (averaged over 1 gram) This EUT has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-200X (Draft 6.5, January 2002). ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-S-1Page 5 of 23 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.8Test standards Standards: - IEEE Std. 1528-200X (Draft 6.5, January 2002) FCC Rule Part(s): - FCC OET Bulletin 65, Supplement C, Edition 01-01 2Technical test 2.1Summary of test results Applicable Configuration Handset (Head) Handset (Body) Headset (Head) Body Worn EquipmentX EUT complies with the RF radiation exposure limits of the FCC as shown by the SAR measurement results. These measurements are taken to simulate the RF effects exposure under worst-case conditions. The EUT complies with the requirements in respect to all parameters subject to the test. The test results and statements relate only to the item(s) tested. Please note that the absorption and distribution of electromagnetic energy in the body are very complex phenomena that depend on the mass, shape, and size of the body, the orientation of the body with respect to the field vectors, and the electrical properties of both the body and the environment. Other variables that may play a substantial role in possible biological effects are those that characterize the environment (e.g. ambient temperature, air velocity, relative humidity, and body insulation) and those that characterize the individual (e.g. age, gender, activity level, debilitation, or disease). Because innumerable factors may interact to dete…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 10 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 11 of 12 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, GermanyRegistration number: G0M20306-7968-P-15Page 12 of 12
14110 Stowe Drive · Poway, California · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 90.00 mW | 1M72Q7W | 13.0000000000 ppm |
Wireless Beltpack
Equipment Class
CBE - Citizens Band End User Devices
Remote Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Remote Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Nexeo AIO headset
Equipment Class
DTS - Digital Transmission System
Battery Charger
Equipment Class
DTS - Digital Transmission System