Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PT-1 PET TRANSMITTER Introduction The Communications Specialists Model PT-1 pet transmitter attaches to your pet's collar so it can be found if lost. The transmitter is programmed to operate on one of 50 channels so multiple pets in a single household or neighborhood can operate at the same time without interference to each other. The channel number of the transmitter is shown on the sticker on the PT-1 case. It weighs less than 1/2 ounce including the battery which allows it to be used with the smallest of pets. The battery will power the PT-1 for approximately 6 weeks. Installation Remove the collar from around your pet's neck and punch a small hole in it with a sharp nail or icepick. Unscrew the small nut holding on the antenna from the threaded shaft on the back of the PT-1. Push the threaded shaft through the hole previously punched in the collar. Reinstall the antenna on the threaded shaft and secure it with the removed nut. Tighten down the nut so the PT-1 and antenna do not twist and are securely attached to the collar. The PT-1 should be on the outside of the collar and the antenna should be laying parallel against it. Battery The battery is a CR2032 Lithium cell that is available from us in a 12 pack conveniently labeled for monthly battery changes. It may also be found at drug stores or markets that sell photo or hearing aid batteries. To change the battery, pop off the front cover on the PT-1 using your fingernail and remove the battery by grasping the finger tab that is laying down against the + side of it. Pull out the battery and dispose of it properly. Remove the current month's battery from the 12 pack by pushing it through the back of the package. This way you will always know in which month you replaced it. Install the new battery by holding the finger tab and gently sliding it into the battery compartment. Pop the back cover on and you are done for another 6 weeks. FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications to this device will void the user's authority to operate the equipment. Warranty The PT-1 is warranted to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. Just return the unit to the factory and we will repair or replace it at no charge.
January 5, 2004 Federal Communications Commission Equipment Approval Services Post Office Box 358315 Pittsburgh, PA 15251-5315 To Whom It May Concern: The following submittal is to apply for equipment certification for the CAT Transmitter. Garwood Laboratories, Inc. will be submitting this package on behalf of the applicant, Communications Specialist, Inc. A letter authorizing Garwood Laboratories as an agent for Communications Specialist, Inc. is available upon request. Regards, Arnie Tapia EMC Engineer Garwood Laboratories, Inc
Confidential Trade Secret Material
Confidential Trade Secret Material
Operational Description- The PT-1 transmitter generates a very low power pulsed CW signal on one operating frequency between 216.025Mhz and 235.000Mhz. The PT-1 is a synthesized design referenced to a .2PPM TCXO. The CPU controls the transmitter on/off switching and the PLL,which locks the VCO on the proper frequency. The output of the VCO feeds a single stage of amplification followed by a 5th order low pass filter connected to the antenna. The unit is powered by a CR2032 lithium battery.
1 of 21 FCC EMC TEST REPORT for COMMUNICATIONS SPECIALISTS TRANSMITTER Model: PT-1 Transmitter Date: January 19, 2004 EUT: Transmitter 2 of 21 GARWOOD LABORATORIES, INC. TESTING AND ENGINEERING SERVICES FCC PART 15 SUBPART C § 15.209 Intentional Radiators EVALUATION REPORT RADIO FREQUENCY INTERFERENCE TEST Prepared for: COMMUNICATIONS SPECIALISTS Product Description: TRANSMITTER Model: PT-1 Transmitter Test Completion Date: January 19, 2004 GARWOOD LABORATORIES, INC. 950 Calle Negocio, San Clemente, CA 92673950 Calle Negocio, San Clemente, CA 92673 Phone: 949Phone: 949--361361--9189 Fax: 9499189 Fax: 949--391391--95979597 Report No: FR26031SE EMC TEST REPORT FOR COMMUNICATIONS SPECIALIST, INC. Date: January 19, 2004 EUT: Transmitter 3 of 21 “EXCELLENCE BUILT ON INTEGRITY” TABLE OF CONTENTS 1.0 INTRODUCTORY SUMMARY 2.0 SUMMARY OF TEST 2.1 ADMINISTRATIVE DATA AND TEST DESCRIPTION 2.2 TEST RESULT - CONDUCTED EMISSIONS 2.3 TEST RESULT - RADIATED EMISSIONS 2.4 MODIFICATIONS 2.5 INTENT TO INCORPORATE ENGINEERING REWORK 2.6 RECOMMENDATIONS 3.0 TEST CONFIGURATION AND DESCRIPTION OF EUT 3.1 SKETCH OF EQUIPMENT AND CABLE CONFIGURATION 3.2.1 DESCRIPTION OF EUT 3.2.2 DESCRIPTION OF PERIPHERAL EQUIPMENT 3.3 TYPES OF CABLES USED 3.4 OPERATION MODES 3.5 PHOTOGRAPHS OF TEST SETUP AND EUT 3.6 DETAILED BLOCK DIAGRAM OF EUT 4.0 TEST EQUIPMENT AND TEST SETUPS 4.1 LIST OF TEST EQUIPMENT USED AND CALIBRATION DATES 4.2 CONDUCTED EMISSIONS TEST SETUP 4.3 RADIATED EMISSIONS TEST SETUP 5.0 TEST PROCEDURE 5.1 CONDUCTED EMISSIONS TEST 5.2 RADIATED PRELIMINARY TEST 5.3 RADIATED EMISSIONS TEST 5.4 FINAL RADIATED TESTING 6.0 SAMPLE CALCULATIONS 7.0 MEASUREMENTS AND UNCERTAINTIES 8.0 LABELING AND NOTIFICATION REQUIREMENTS GARWOOD LABORATORIES, INC. 950 Calle Negocio, San Clemente, CA 92673950 Calle Negocio, San Clemente, CA 92673 Phone: 949Phone: 949--361361--9189 Fax: 9499189 Fax: 949--391391--95979597 Report No: FR26031SE EMC TEST REPORT FOR COMMUNICATIONS SPECIALIST, INC. Date: January 19, 2004 EUT: Transmitter 4 of 21 “EXCELLENCE BUILT ON INTEGRITY” 1.0 INTRODUCTORY SUMMARY RESPONSIBLE SIGNATURES This report is intended for the use by the organization to whom it is addressed, and will not be made available to any other parties without the expressed written consent of the aforementioned organization. This report shall not be reproduced, except in full, without the written approval of Garwood Laboratories, Inc. WRITTEN BY: REVIEWED BY: REVIEWED BY: Stephen Heyman EMC Technical Writer Arnulfo Tapia Senior EMC Test Engineer Tony Masone EMC Manager DOCUMENT HISTORY Revision Issue Date Affected Page(s) Description Of Modifications Revised By Approved By N/C January 19, 2004 Initial release GARWOOD LABORATORIES, INC. 950 Calle Negocio, San Clemente, CA 92673950 Calle Negocio, San Clemente, CA 92673 Phone: 949Phone: 949--361361--9189 Fax: 9499189 Fax: 949--391391--95979597 Report No: FR26031SE EMC TEST REPORT FOR COMMUNICATIONS SPECIALIST, INC. Date: January 19, 2004 EUT: Transmitter 5 of 21 “EXCELLENCE BUILT ON INTEGRITY” CLIENT INFORMATION Purchase Order EUT Arrival Date 121703-SP January 19, 2004 Company Name Address City, State Zip Communications Specialist, Inc. 426 West Taft Ave Orange, CA 92865 Contact Name Phone Fax Spence Porter 714-998-3021 714-974-3420 GARWOOD INFORMATION EMC Test Laboratory Address City, State, Zip Code Phone Fax Web Site Garwood Laboratories, Inc. 950 Calle Negocio San Clemente, CA 92673 (949) 361-9189 (949) 361-9597 www.garwoodtestlabs.com Contact Name Title Contact Phone Contact Fax Tony Masone EMC Manager (562) 949-2727 (562) 949-8757 Test Personnel Test Dates Terry Reysbergen – EMC Test Engineer 19 January 2004 GARWOOD LABORATORIES, INC. 950 Calle Negocio, San Clemente, CA 92673950 Calle Negocio, San Clemente, CA 92673 Phone: 949Phone: 949--361361--9189 Fax: 9499189 Fax: 949--391391--95979597 Report No: FR26031SE EMC TEST REPORT FOR COMMUNICATIONS SPECIALIST, INC. Date: January 19, 2004 EUT: Transmitter 6 of 21 “EXCELLENCE BUILT ON INTEGRITY” Accreditations: The Open Area Test Site (OATS) and measurement facilities used to collect the test data are located at Garwood Laboratories, Incorporated test facility in San Clemente, California. The test facility is recognized, certified, or accredited by the following organizations: Garwood Laboratories, Inc. is accredited by the U.S. National Institute Standards Technology under NVLAP as suppliers of test results to the criteria established by ISO/IEC 17025 and ISO 9002. The accreditation is valid through September 30, 2004. BSMI Garwood Laboratories, Inc. has been validated by the Chinese Taipei Bureau of Standards, Metrology and Inspection (BSMI) under the Asia Pacific Economic Cooperation Mutual Recognition Arrangement (APEC MRA). Garwood Laboratories is now provisionally designated to act as a Conformity Assessment Body (CAB) under Appendix B, Phase 1 Procedures of the APEC MRA. The BSMI assigned number is SL2-IN-E-059R. TUV Garwood Laboratories, Inc. is approved by TUV Product Services as a test facility testing to the EMC DIRECTIVE 89/336/EEC. Garwood Laboratories, Inc. is approved as a contractor to Radio Frequency investigation LTD, a UK Competent Body and by Radio Frequency Technologies LTD, a Competent Body of Ireland. GARWOOD LABORATORIES, INC. 950 Calle Negocio, San Clemente, CA 92673950 Calle Negocio, San Clemente, CA 92673 Phone: 949Phone: 949--361361--9189 Fax: 9499189 Fax: 949--391391--95979597 Report No: FR26031SE EMC TEST REPORT FOR COMMUNICATIONS SPECIALIST, INC. Date: January 19, 2004 EUT: Transmitter 7 of 21 “EXCELLENCE BUILT ON INTEGRITY” 2.0 SUMMARY OF TEST 2.1A ADMINISTRATIVE DATA DEVICE TESTED: Description: Transmitter Model: PT-1 Transmitter ACCESSORIES: N/A APPLICANT: Communications Specialists CONTACT: Spence Porter MANUFACTURER: Communications Specialists 2.1B TEST DESCRIPTION FREQUENCY RANGES: Conducted: 0.45 - 30.0 MHz Radiated: 30.0 - 1000 MHz Radiated: All Harmonics of Fundamental frequency TEST LOCATION: 950 Calle…
Text truncated - open the document above for the full version.
3.5 PHOTOGRAPHS OF TEST SETUP AND EUT (Radiated) 3.5 PHOTOGRAPHS OF TEST SETUP AND EUT (Radiated)
950 Calle Negocio · San Clemente, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 216.025 MHz - 235 MHz | - |

Ankle/Wrist Homing Transmitter
Equipment Class
TNT - Licensed Non-Broadcast Transmitter Worn on Body
Livestock Telemetry Transmitter
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
LPRS TRQNSMITTER
Equipment Class
TNB - Licensed Non-Broadcast Station TransmitterTNT - Licensed Non-Broadcast Transmitter Worn on Body
Equipment Class
TNT - Licensed Non-Broadcast Transmitter Worn on BodyPLL Synthesized Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter