Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ownerโs Manual PT-2 LAW ENFORCEMENT TRACKING TRANSMITTER INTRODUCTION The Communications Specialists Model PT-2 transmitter is used as a homing device to locate persons or stolen goods under authority or agreement with a law enforcement agency (federal, state, or local) having jurisdiction in the area where it is placed. It is programmed at the factory to transmit on any one of 200 individual narrowband channels in the Low Power Radio Service (LPRS). This allows 200 transmitters to be used simultaneously in an area for unprecedented flexibility. Power output is 80 mW. It uses a widely available CR123A Lithium battery which transmits continuously for 12 days or a rechargeable battery which transmits continuously for 6 days. The battery snaps into a holder which is attached to the PT-2. A retainer snaps over the battery to hold it in under even the most demanding conditions. It is small in size (1.7"x1.2"x.9" without magnet) with an 8" attached loaded antenna. Its total weight is 1.5 oz. It includes a steel keeper on one side that allows the supplied rare earth magnet to keep it attached to the bottom of a vehicle or other item for quick and easy installation. For non magnetic use, the magnet need not be used. The PT-2 utilizes a TCXO rather than a fragile crystal so it is almost indestructible. BATTERY INSTALLATION Snap a CR123A battery into the battery holder. Be sure to observe the proper polarity by noting the diagram on the inside of the holder. If the battery is accidentally reversed, the PT-2 will not operate but it will not be damaged. Just pop out the battery and reverse it to resume operation. Snap the retainer over the battery to hold it in. Be sure to test the PT-2 on your receiver before use to ascertain that it is operating. To remove the battery, pry up the bottom edge of the retainer with a small screwdriver to pop it off. FCC COMPLIANCE NOTICE The PT-2 transmitter (FCC ID CFXPT-2) is authorized by rule under the Low Power Radio Service (47 C.F.R. Part 95) and must not cause harmful interference to TV reception or United States Navy SPASUR installations. You do not need an FCC license to operate this transmitter. This transmitter may only be used to provide: auditory assistance to persons with disabilities, persons who require language translation, or persons in educational settings; health care services to the ill; law enforcement tracking services under agreement with a law enforcement agency; or automated maritime telecommunications system (AMTS) network control communications. Two-way voice communications and all other types of uses not mentioned above are expressly prohibited. CAUTION: Any changes or modifications to this device could void the user's authority to operate the equipment. CHANNEL USE POLICY The channels authorized to LPRS systems by the FCC rules are available on a shared basis only and will not be assigned for the exclusive use of any entity. Those using LPRS transmitters must cooperate in the selection and use of channels in order to reduce interference and make the most effective use of the authorized facilities. Channels must be selected in an effort to avoid interference to other LPRS transmissions. WARRANTY The PT-2 is warranted to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. Just return the unit to the factory and we will repair or replace it at no charge.
FCC COMPLIANCE NOTICE The PT-2 transmitter (FCC ID CFXPT-2) is authorized by rule under the Low Power Radio Service (47 C.F.R. Part 95) and must not cause harmful interference to TV reception or United States Navy SPASUR installations. You do not need an FCC license to operate this transmitter. This transmitter may only be used to provide: auditory assistance to persons with disabilities, persons who require language translation, or persons in educational settings; health care services to the ill; law enforcement tracking services under agreement with a law enforcement agency; or automated maritime telecommunications system (AMTS) network control communications. Two-way voice communications and all other types of uses not mentioned above are expressly prohibited. CAUTION: Any changes or modifications to this device could void the user's authority to operate the equipment. The LPRS device is too small for a compliance statement. The compliance statement is placed in a prominent location in the instruction manual supplied to the user.
PART 95 ATTESTATION June 3, 2005 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Gentlemen: Reference: CFXPT-2 This equipment meets the Low Power Radio Service requirements of the FCC Rules, Part 95. Programming of this productโs transmitter power and its transmit frequencies can be performed ONLY by the manufacturer. The operator cannot increase transmitter power or program transmit frequencies using the equipmentโs external operation controls. (Rule 95.649) Sincerely. Communications Specialists, Inc. Albert Spencer Porter President
External bottom photo
External topside photo
Photo showing FCC ID label and its location on PT-2
Printed Circuit Board bottom photo
Printed Circuit Board Front photo with shield
Printed Circuit Board Front photo without shield
PT-2 DESCRIPTION OF CIRCUITRY The PT-2 transmitter is a PLL synthesized design using a 1.0ppm TCXO as the reference oscillator. A microprocessor controls all of the functions of the PLL, oscillator, and amplifier stages. The circuit has a 1 stage VCO oscillator locked to the PLL, followed by 4 stages of amplification. Any harmonic or spurious signals are filtered out by a 5th order 230Mhz low pass filter before reaching the antenna.
PT-2 Parts Lists CommentDesignatorFootprint 12p FC-010402 0.1u FC-020603 100p FC-030402 10u F, 10VC-040805-1 1000p FC-050201-3 0.01u FC-060402 1000p FC-070201-3 10u F, 10VC-080805-1 1000p FC-090201-3 10uF, 10VC-100805-1 0.1u FC-110603 1000p FC-120201-3 330p F, NPOC-130603 0.1u FC-140603 1000p FC-150201-3 openC-160201-3 1000p FC-170201-3 1p FC-180201-3 7p FC-190201-3 5p FC-200201-3 5p FC-210201-3 220p FC-220603 3900p FC-230603 10u F, 10VC-240805-1 1000p FC-250201-3 1000p FC-260201-3 100p FC-270201-3 1000pFC-280201 47p FC-290201-3 1000p FC-300201-3 56p FC-310201-3 1000p FC-320201-3 6p FC-330201-3 5p FC-340201-3 1000p FC-350201-3 1000p FC-360201-3 6p FC-370201-3 33p FC-380201-3 0.01u FC-390402 1000p FC-400201 82p FC-410402 22p FC-420201-3 5p FC-430201-3 5p FC-440201-3 100 pFC-450201-3 1000p FC-460201-3 1000p FC-470201-3 0p FC-480201-3 10u F, 10VC-490805-1 1000p FC-500201-3 1p FC-510201-3 10uF, 10VC-520805-1 100p FC-530201-3 0.01u FC-540402 10u F, 10VC-550805-1 10u FC-560805-1 0.1u FC-570603 0.056u F C-580805-1 6p FC-590201-3 100p FC-600201-3 0p FC-610201-3 4p FC-620201-3 1000p FC-630201-3 MA27V0700D-01SSS-mini-2 33n HL-011008HQ 120n HL-021008HQ 47n HL-031008-COIL-2 56n HL-040805-COIL 56n HL-050805-COIL 56n HL-060805-COIL 33n HL-070805-COIL 12n HL-080805-COIL 12n HL-090805-COIL 100n HL-100805-COIL NE681M13Q-01CEL-M13-Mark-1 NE681M13Q-02CEL-M13-Mark-1 NE681M13Q-03CEL-M13-Mark-1 NE68819Q-04CEL-19 - W MARK NE664M04Q-05CEL-M04-NE664M04 18K OHR-010201-3 10K OHR-020201-3 1M OHR-030201-3 100K OHR-040201-3 10M OHR-050402 1K OHR-060201-3 1K OHR-070201-3 100 OHR-080201-3 150 OHR-090201-3 1.5K OHR-100201-3 330 OHR-110201-3 100 OHR-120201-3 33K OHR-130201-3 1.0K OHR-140201-3 100K OHR-150201-3 6.8K OHR-160201-3 680 OHR-170201-3 10K OHR-180201-3 10K OHR-190201-3 27K OHR-200201-3 100 OHR-210201-3 1K OHR-220201-3 openR-230201-3 22K OHR-260201-3 56K OHR-270201-3 150 OHR-280201-3 56K OHR-320201-3 10K OHR-330201-3 10K OHR-340201-3 CM1600SW-01COMUS-1600-0-A-LRG-PAD reed switchSW-02reed-switch-2 LP3987-2.5VU-01NS-TLA05-LP3987-3 8051F305U-02MLP-11-B-8051F30X-1 TC7SL04FUU-03SSOP-5-P-0.65-TC7SC04FU LMX2470U-04NS-LMX2470-1 LP3987-2.5VU-05NS-TLA05-LP3987-3 JN015VC-01VOLTRONICS-JN-3 10KVR-01POT-P2W-SM-PAD TTS-18-19.2MhzXTAL-01TEW-TTS18-SML-PAD
List of Active device and symbol and its functions. Designator Footprint Function Q-01 CEL-M13-Mark-1 Oscillator Q-02 CEL-M13-Mark-1 buffer amplifier Q-03 CEL-M13-Mark-1 pre-amplifier Q-04 CEL-19 - W MARK driver amplifier Q-05 CEL-M04-NE664M04 final amplifier U-01 NS-TLA05-LP3987-3 voltage regulator U-02 MLP-11-B-8051F30X-1 CPU U-03 SSOP-5-P-0.65-TC7SC04FU interver U-04 NS-LMX2470-1 PLL synthesyzer U-05 NS-TLA05-LP3987-3 voltage regulator XTAL-01 TEW-TTS18-SML-PAD crystal oscillator
PT-2 FACTORY TUNE UP PROCEDURE PRIOR TO POTTING 1. Download test firmware. This changes the PT-2 frequency to 216.000Mhz. 2. Adjust trimmer pot VR-01 to set the VCO frequency to 216.000Mhz (+ or - 20Hz). 3. With the frequency at 216.000Mhz, align VC-1 so the VCO test voltage is .3v (+ or - .1V). 4. Check power output to make sure it is 17.0dBm to 19.5dBm. 5. Check that all harmonics or spurious signals are at least 50dB down from main carrier. 6. Download test firmware to change the transmitting frequency to 222.000Mhz 7. Check that the VCO frequency is 222.000Mhz (+ or - 20Hz). 8. Check that the VCO test point is less than 1.7v. 9. Check that the power output is 17.0dBm to 19.5dBm. 10. Check that all harmonics or spurious signals are at least 50dB down from main carrier.
M. Flom Associates, Inc. 3356 North San Marcos Place, Suite 107 Page 19 of 22 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, (480) 926-3598 fax MFA p0550007, d0560013 Name of Test: Frequency Stability (Temperature Variation) Measurement Results State: Room Temperature: 23ยฐC ยฑ 3ยฐC Frequency vs. Temperature 216.00225 216.00230 216.00235 216.00240 216.00245 216.00250 216.00255 216.00260 216.00265 216.00270 216.00275 -30-20-100102030405060 Performed By: David E. Lee, Test Engineer
M. Flom Associates, Inc. 3356 North San Marcos Place, Suite 107 Page 6 of 22 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, (480) 926-3598 fax MFA p0550007, d0560013 Subpart 2.1033 (continued) (c)(8): Voltages & currents in all elements in final RF stage, including final transistor or solid-state device : Collector Current, A = 0.03 max (measured) Collector Voltage, Vdc = 2.5 Supply Voltage, Vdc = 3.6 (c)(9): Tune-Up Procedure: Please see attached exhibits (c)(10): Circuit Diagram/Circuit Description: Including description of circuitry & devices provided for determining and stabilizing frequency, for suppression of spurious radiation, for limiting modulation and limiting power. Please see attached exhibits (c)(11): Label Information: Please see attached exhibits (c)(12): Photographs: Please see attached exhibits (c)(13): Digital Modulation Description: ___ Attached Exhibits _x_ N/A (c)(14): Test and Measurement Data: Follows
M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, fax (480) 926-3598 MFA p0550007, d0560013 Date: June 9, 2005 Federal Communications Commission Via: Electronic Filing Attention: Authorization & Evaluation Division Applicant: Communication Specialists, Inc. Equipment: PT-2 FCC ID: CFXPT-2 FCC Rules: 95G, Confidentiality Gentlemen: On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report and all pertinent documentation, the whole for approval of the referenced equipment as shown. Filing fees are attached. We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized to act as agent. Sincerely yours, Michael Schafer, Business Manager enclosure(s) cc: Applicant DEL/del M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, fax (480) 926-3598 MFA p0550007, d0560013 Transmitter Certification of FCC ID: CFXPT-2 Model: PT-2 to Federal Communications Commission Rule Part(s) 95G, Confidentiality Date of report: June 9, 2005 On the Behalf of the Applicant: Communication Specialists, Inc. At the Request of: P.O. 050405PL Communication Specialists, Inc. 426 W. Taft Ave Orange, CA 92665-4296 Attention of: 1 800 854 0547; 714 998 3021; FAX: 714 974 3420 Spence Porter, President Supervised by: Michael Findley, Laboratory Manager M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, fax (480) 926-3598 MFA p0550007, d0560013 List of Exhibits (FCC Certification (Transmitters) - Revised 9/28/98) Applicant: Communication Specialists, Inc. FCC ID: CFXPT-2 By Applicant: 1. Letter of Authorization 2. Confidentiality Request: 0.457 And 0.459 3. Part 90.203(e) & (g) Attestation 4. Identification Drawings, 2.1033(c)(11) Label Location of Label Compliance Statement Location of Compliance Statement 5. Photographs, 2.1033(c)(12) 6. Documentation: 2.1033(c) (3) User Manual (9) Tune Up Info (10) Schematic Diagram (10) Circuit Description Block Diagram Parts List Active Devices By M.F.A. Inc.: A. Testimonial & Statement of Certification M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, fax (480) 926-3598 MFA p0550007, d0560013 The Applicant has been cautioned as to the following: 15.21 Information to the User. The users manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.27(a) Special Accessories. Equipment marketed to a consumer must be capable of complying with the necessary regulations in the configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of ensuring that the special accessories are provided to the consumer, without additional charge. Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in ยง 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such devices shall include appropriate instructions on the first page of text concerned with the installation of the device that these special accessories must be used with the device. It is the responsibility of the user to use the needed special accessories supplied with the equipment. M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, fax (480) 926-3598 MFA p0550007, d0560013 Table of Contents Rule Description Page 2.1033(c)(14) Rule Summary 2 . Standard Test Conditions and Engineering Practices 3 2.1033(c) General Information Required 5 2.1046(a) Carrier Output Power (Conducted) 7 2.1046(a) ERP Carrier Power (Radiated) 9 2.1053(a) Field Strength of Spurious Radiation 10 2.1049(c)(1) Emission Masks (Occupied Bandwidth) 14 2.1055(a)(1) Frequency Stability (Temperature Variation) 18 2.1055(b)(1) Frequency Stability (Voltage Variation) 20 2.202(g) Necessary Bandwidth and Emission Bandwidth 22 M. Flom Associates, Inc. 3356 North San Marcos Place, Suite 107 Page 1 of 22 Chandler, Arizona 85225-7176 FCC ID: CFXPT-2 (480) 926-3100 phone, (480) 926-3598 fax MFA p0550007, d0560013 Required information per ISO/IEC Guide 25-1990, paragraph 13.2: a) Test Report b) Laboratory: (FCC: 31040/SIT) (Canada: IC 2044) M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, AZ 85225 c) Report Number: d0560013 d) Client: Communication Specialists, Inc. 426 W. Taft Ave Orange, CA 92665-4296 e) Identification: PT-2 FCC ID: CFXPT-2 EUT Description: LPRS Transmitter f) EUT Condition: Not required unless specified in individual tests. g) Report Date: June 9, 2005 EUT Received: 2005-May-17 h, j, k): As indicated in individual tests. i) Sampling method: No sampling procedure used. l) Uncertainty: In accordance with MFA internal quality manual. m) Supervised by: Michael Findley, Laboratory Manager n) Results: The results presented in this report relate only to the item tested. o) Reproduction: This report must not be reproduced, except in full, without written permission from this laboratory. M. Flom Associates, Inc. 3356 North San Marcos Place, Suite 107 Page โฆ
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95G | 216.0005 MHz - 216.9975 MHz | 80.00 mW | NON | 1.5000000000 ppm |

Ankle/Wrist Homing Transmitter
Equipment Class
TNT - Licensed Non-Broadcast Transmitter Worn on Body
Livestock Telemetry Transmitter
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
PT-1 Pet Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterTNT - Licensed Non-Broadcast Transmitter Worn on Body
Equipment Class
TNT - Licensed Non-Broadcast Transmitter Worn on BodyPLL Synthesized Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter