FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. BI Incorporated/
  3. CSQHG200W

CSQHG200WWrist-Mount Low Power RF Transmitter

BI Incorporated
Wrist-Mount Low Power RF Transmitter - FCC ID CSQHG200W - BI Incorporated
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 08, 2000
Application Purpose
Original Equipment
Date of Application
Mar 14, 1999
Equipment Note
Wrist-Mount Low Power RF Transmitter
Frequency Range
314.20000000 - 314.20000000
Company
BI Incorporated
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗
↗
↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BI HomeGuard 200 TM User’s Manual Copyright 1999 BI Incorporated Revision A Notice HomeGuard 200 User’s Manual Copyright © 1999 by BI Incorporated All Rights Reserved Printed in USA BI prepared this manual for use by BI customers only. All comments concerning the contents of this manual should be directed to BI’s Marketing Department, 6400 Lookout Road, Boulder, CO 80301, USA. No part of this work covered by copyright may be reproduced in any form either graphically, electronically, mechanically; including photocopying, recording, taping, or storage in an information retrieval system without prior written permission from BI. Trademarks and Patents BI and the BI logo are registered trademarks of BI Incorporated. K2 Home Escort Host System is a registered trademark of BI Incorporated. BI SkyGuard 200, BI HomeGuard 200, BI 9000 Field Monitoring Device (FMD), BI 9200 REACT, BI Sobrietor, SR Transmitter, and BI 9010 Transmitter are all trademarks of BI Incorporated. US Patent Nos., 4,843,377; 4,996,161; 4,999,613. Technical Support For help related to test scheduling, reporting and host computer functions call your monitoring center. BI Incorporated has two Monitoring Centers, East and West. West MonitoringEast Monitoring BI IncorporatedBI Incorporated 6400 Lookout RoadOne Citizen’s Plaza, Suite 501 Boulder, CO 80301 USAAnderson, Indiana 46016 (303) 218-1225(765) 641-2496 (800) 241-6768(800) 825-1044 FAX (303) 218-1250FAX (765) 649-3148 For technical assistance with BI Products, call BI Technical Support at (800) 241-9924 or your BI Account Service Representative at _________________________. Purpose This manual provides an officer with the information necessary to implement and use the HomeGuard electronic monitoring device. Scope The User’s Manual presents a tutorial for use of the HomeGuard electronic monitoring device and a guide in training clients to use the equipment in their homes. It provides all information required to: • learn to use the HomeGuard device • teach clients to use the HomeGuard device • install the HomeGuard device on site • set up testing schedules and monitoring requirements • troubleshoot and use the HomeGuard device Note: Throughout this manual, the name HomeGuard refers to the HomeGuard tracking device. Audience This manual is written for the attending officer who will train the client, set up the equipment and monitor the client. FCC Compliance Statement United States FCC, Part 15 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications made by the user to this equipment that are not expressly approved by BI, Inc. could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. There is no guarantee, however, that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet/circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.

Cover Letter(s)

FCC ID: CSQHG200W ENGINEERING STATEMENT For Certification of BI Inc. Wrist-Mount Low Power RF Transmitter FCC ID: CSQHG200W Model No. HG200W I am an Electromagnetic Compatibility test engineer with TUV Product Service, Boulder, Colorado. My education and experience are a matter of record with the Federal Communications Commission. TUV Product Service has been authorized by BI Inc., 6400 Lookout Road, Boulder, Colorado 80301, to make FCC Part 15 Certification measurements on the Wrist-Mount Low Power RF Transmitter. These tests were made by me or under my supervision at our Pinewood Springs Laboratory which is registered with the FCC under Paragraph 15 of the FCC Rules. Test data required by the FCC for FCC Part 15 Certification is included in this report. It is submitted that the above equipment meets FCC requirements and FCC Part 15 Certification is hereby requested. ________________________ Shawn Singh EMC Engineer TUV Product Service Dated: 11 March 1999 PRODUCT SERVICE

ID Label/Location Info

FCC LABEL A drawing of the FCC label information that will be permanently affixed to the transmitter case is shown below. The location is on the bottom of the plastic case. Due to the small size of this device, it is not practical to place the complete label statement on the transmitter. Therefore, the information shown below is included in the instruction manual: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: CSQHG200W CANADA XXXX XXXXX BI INCORPORATED .75" 1.1"

Test Report

FCC ID: CSQ-HG200W File No. BC1G907501, Page 1 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 EMC EMISSION - TEST REPORT Test Report No. B907501 Issue Date14 March 1999 Model / Serial No. HG200W / SFW001 Product Type Wrist-Mount Low Power RF Transmitter Client BI, Inc. Manufacturer BI, Inc. License holder BI, Inc. Address 6400 Lookout Road Boulder, CO 80301 Test Criteria AppliedFCC Part 15C15.231 Test Start Date:08 March 1999 Test End Date:08 March 1999 Test Result nn PASSoo FAIL Test Report Project No. BC1G907501 Total Pages including Appendices 40 Reviewed By : Felix J. ChavezReviewed By : Shawn Singh TÜV Product Service Inc is a subcontractor to TÜV Product Service, GmbH according to the principles outlined in ISO/IEC Guide 25 and EN 45001. TÜV Product Service Inc reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. TÜV Product Service Inc shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV Product Service Inc issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval of TÜV Product Service. This report shall not be used by the client to claim product endorsement by NVLAP or any agency of the US government. TÜV Product Service Inc and its professional staff hold government and professional organization certifications and are members of AAMI, ACIL, AEA, ANSI, IEEE, NVLAP, and VCCI PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page 2 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 DIRECTORY - EMISSIONS Page(s) Documentation Test report1 - 3 Directory2 Test Regulations3 General Remarks3 Test-setup Photographs4-5 Test Equipment Used6-10 Appendix A Transmitter Data Sheets A1 - A2 Appendix B Detailed Test Data Sheets B1 - B8 Appendix C Plot of 20 dB bandwidth C1 - C2 Appendix D Plots of Calculated Duty Cycle D1 - D3 Appendix E Test Plan/Constructional Data Form E1 - E12 Appendix F Measurement of Protocol F1 - F3 PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page 3 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 EMISSIONS TEST REGULATIONS : The tests were performed according to following regulations : n - Federal Communication Commission part 15o - Class An - Class B n - Federal Communication Commission part 15, Subpart Cn - 15.209n - 15.231 -------------------------------------------------------------------------------- All tests performed according to ANSI C63.4. Emission Test Results: Conducted emissions 150 kHz - 30 MHz Test Resultoo - PASS oo - FAILnn - Not Applicable Passing MargindBatMHz Remarks:EUT is battery operated. Radiated emissions (electric field) 30 MHz - 1000 MHz (Unintentional Radiator) Test Resultnn - PASS oo - FAILoo - Not Applicable Passing Margin22.7dBat60.49MHz Remarks: Radiated emissions (electric field) 314.2 MHz - 3142 MHz (Intentional Radiator) Test Resultnn - PASS oo - FAILoo - Not Applicable Passing Margin12.8dBat628.4MHz Remarks: GENERAL REMARKS: Modifications required to pass: None Test Specification Deviations: Additions to or Exclusions from: None PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page 4 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Test-setup photo(s) Radiated Emissions PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page 5 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Test-setup photo(s): Conducted Emissions Test Not Applicable PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page 6 of 10 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Test Equipment Used PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page A1 of A2 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix A Transmitter Data Sheets PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501 , Page B1 of B8 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix B Detailed Test Data Sheets PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page C1 of C2 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix C Plots of 20 dB Bandwidth PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page D1 of D3 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix D Plots of Calculated Duty Cycle PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page E1 of E12 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix E Test Plan and Constructional Data Form PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page F1 of F3 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 Appendix F Measurement of Protocol PRODUCT SERVICE FCC ID: CSQ-HG200W File No. BC1G907501, Page F2 of F3 TÜV PRODUCT SERVICE INC40 Meadow RoadPinewood Springs, Lyons, CO 80540Tel: 303 786 7999Fax: 303 449 3004Rev.No 1.0 MEASUREMENT PROTOCOL FOR FCC GENERAL INFORMATION Measurement Uncertainty The test system for conducted emissions is defined as the LISN, tuned receiver or spectrum analyzer, and coaxial cable. The…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Evencio Fernandez(VP, Hardware Engineering)
[email protected]303-218-1000Fax: 303-218-1250

Technical Contact

TUV Product ServiceShawn Singh
[email protected]303 402 5262

5541 Central Avenue · Boulder, Colorado · United States

Non-Technical Contact

TUV Product ServiceFelix J Chavez
[email protected]303 402 5248

Test Firm

International Approval Laboratories, LLCTodd Seeley
[email protected]303-402-5272Fax: 303-449-6160

Technical Specifications

#Rule PartsFrequency RangePower Output
115C314.2 MHz - 314.2 MHz-
Confidentiality
Long Term

Other Applications from BI Incorporated

Mobile breathalyzer with LTE capability. - FCC ID CSQ-SL300A - BI Incorporated
CSQ-SL300A

Mobile breathalyzer with LTE capability.

May 10, 2020

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
The BI LOC8 device is a single-piece, ankle-mounted tracking unit using GPS data and other location monitoring technologies to track individuals supervised by law enforcement agencies or pursuant to the order of a court - FCC ID CSQ-LC800A - BI Incorporated
CSQ-LC800A

The BI LOC8 device is a single-piece, ankle-mounted tracking unit using GPS data and other location monitoring technologies to track individuals supervised by law enforcement agencies or pursuant to the order of a court

Jul 07, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
BI HomeGuary 200 - FCC ID CSQHG200C - BI Incorporated
CSQHG200C

BI HomeGuary 200

Jan 26, 2003

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
HomeGuard  Standard Transmitter, Model HG200B - FCC ID CSQHG200B - BI Incorporated
CSQHG200B

HomeGuard Standard Transmitter, Model HG200B

Dec 09, 2001

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
CSQBI9010

House Arrest Transmitter

Feb 28, 1995

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter