Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RFID System V680 Series User's Manual Cat. No.: Z248-E1-01 Amplifier and Antennas V680-HA63B V680-HS52 V680-HS63 ID Tags V680-D2KF52 V680-D2KF67 V680-D2KF67M Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. Please observe the following items when using the RFID System. • Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. • Read and understand this manual before attempting to use the RFID System and use the RFID Sys- tem correctly. • Keep this manual in a safe and accessible location so that it is available for reference when required. Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Introduction Section 1 Section 2 Section 3 Section 4 Section 5 READ AND UNDERSTAND THIS DOCUMENT Product Overview Specifications and Performance Communications Specifications Installation Chemical Resistance RFID System V680-HA63BAmplifier V680-HS52Antenna V680-HS63Antenna V680-D2KF52ID Tag V680-D2KF67ID Tag V680-D2KF67MID Tag User's Manual 2 Introduction RFID System User's Manual Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FIT- NESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABIL- ITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CON- TAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s applica- tion or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the prod- ucts. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key spec- ifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming o…
Text truncated - open the document above for the full version.
DECLARATION September 26, 2006 Subject : Declaration for Professional Use Product : Amplifier (13.56MHz RFID System) Applicant : OMRON Corporation Model : V680-HA63 FCC ID : E4E6CYSIDV6800306 We, OMRON Corporation, hereby declare, at our sole responsibility, that this product is manufactured for professional use only. This product is intended to be sold to professional users directly from OMRON. Only professional installer is objective for sale, also product is intended to be installed in the end product which is operated in factories. Sincerely, Shinyu Fujiki Dept. Manager Sensing Devices & Components Div. H.Q. Industrial Sensor Division
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 September 22, 2006 RE: FCC ID: E4E6CYSIDV6800306_ATCB004046 Attention: Yoshiko Mizuta I have a few comments on this Application. Please note that further comments may arise in response to answers provided to the questions below. 1. Please note that the device appears to have a standard BNC connector. If this is for the antenna or if it is for an external antenna, then the device must be professionally installed. Please note that “Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems” does not meet this requirement. Please provide a manual that clearly states that the device must be professionally installed. 2. Please note that the manual and the test report calls this device an “amplifier”. Please note that part 15 does not allow amplifiers unless it is an integral part of a transmitting system. Please explain the term amplifier in this application. Is the device an amplifier or is it an intentional radiator? If it is an amplifier, to what transmitting device is it attached permanently? 3. Please note that while ANSI C63.4 2003 states the room, high and low temperatures are to be measured for temperature frequency stability, 47CFR part 2.1053 clearly states “Frequency measurements shall be made at the extremes of the specified temperature range and at intervals of not more than 10° centigrade through the range.” Please note that where ANSI C63.4 and the specific rules differ, the rules take precedence. Please provide the temperature variation data at 10degree steps. Alternately, please provide evidence that the FCC has allowed you to test only the ambient, high and low temperatures. 4. Please note that the test report refers to “after 2minutes, after 5 minutes, after 10 Minutes” for temperature stability measurements. Please explain if these times start after the required approximate 30 minute temperature stabilization period or otherwise. 5. Please note that, other than the loop antenna in the setup photos being shown, the report does not clearly indicate that frequencies below 30MHz were measured using only a magnetic loop antenna. Please confirm. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
October 5, 2006 Letter of correction Product : Amplifier (13.56MHz RFID System) Applicant : OMRON Corporation Model : V680-HA63 FCC ID : E4E6CYSIDV6800306 Report number “27AE0026-YK” had an error in the FCC ID number referenced “E4E6CYCIDV6800306”. Please note that this letter corrects the FCC ID number in the report to FCC ID: E4E6CYSIDV6800306. Sincerely, Toyokazu Imamura Testing Engineer Yamakita EMC Lab. EMC Service Dept. UL Apex Co., Ltd.
OMRON Corporation FCC ID: E4E6CYSIDV6800306 External Photo Front View (V680-HA63) Back View (V680-HA63) Left View (V680-HA63) Right View (V680-HA63) Upper View (V680-HA63) Lower View (V680-HA63) OMRON Corporation FCC ID: E4E6CYSIDV6800306 Front View (V680-HS52) Rear View (V680-HS52) Side View (V680-HS52) Front View (V680-HS63) Back View (V680-HS63) OMRON Corporation FCC ID: E4E6CYSIDV6800306 Left View (V680-HS63) Right View (V680-HS63) Upper View (V680-HS63) Lower View (V680-HS63)
4 % ⚦ࠢࡑ✚ോ⋭ᜰቯ ✢ 4 4 4 4 ⚦ࠢࡑ㧯㧱 # # $ % & # $ % & '%%106'065'5;/ &'5+)0'&(14 5*''6 &49) 01 4& #0).' 5%#.' /#6'4+#. (+0+5* % '%01 5+)0 㧻㧹㧾㧻㧺㧯㨛㨞㨜㨛㨞㨍㨠㨕㨛㨚 㧭㨘㨘㧾㨕㨓㨔㨠㨟㧾㨑㨟㨑㨞㨢㨑㨐 61.'4#0%'5 70.'55 52'%+(+'& 㧵㨀㧝㧠 &'5+)0'& %*'%-'& #22418'& 㧞㧦㧝 8*#$ 㧝㧤㧠㧡㧤㧢㧢㧙㧝ޓ㧭 +56 ศ 㧝㧛㧝 㧺㧭㧹㧱ޓ㧼㧸㧭㨀㧱㧔㧝㧕 㧔㧝㧕ࡦࡃࠗࡔ ࠆࠃߦਅ ߪ㧣㧚⚦ޓ ߣߎߥࠄᱷ߇ᄖᒻ✢ޓᤨࠅ㧢㧚ޓ ࠆߔߣടᎿ࠻ࡀࡒߒᶖࡗ࠷㧞㧚ޓ ࠆߢ㧼㧯ߪ᧚革ߩ㧡㧚ⵍ⌕ޓ ࠆߔߣ☼⌕ᗵᒻߪ㧠㧚ធ⌕ᣇᴺޓ ࠆࠃߦਅߪᦠߩ㧟㧚ᢥሼޓ ߣߎߩශ࡞ࠪߢ⦡ߩᵈ㧝㧚ਅ⸥ 㧕ࠣ࠻ࠗ⦡㧦㧡㨅㧣㧛㧝㧔ޓޓޓޓ ✢㧦㧺㧝㧚㧡㧔㤥㧕ᢥሼޓޓޓޓ 㧕࠻ࠗࡢࡎࡈࠝㇱ㧦㧡㨅㧥㧚㧞㧛㧜㧚㧡㧔ࠣࡦ࠴࠶ࡂ 㨀㧜㧚㧜㧡ޓ㧼㧱㨀ޓ㨃㧴㨀 ᵈ㧝㧘㧞
OMRON Corporation FCC ID: E4E6CYSIDV6800306 Internal Photo PWB(1) and PWB (2) in Case PWB(1) and PWB (2) in Case (V680-HA63) (V680-HA63) PWB (1) Side A (V680-HA63) PWB (1) Side B (V680-HA63) PWB (2) Side A (V680-HA63) PWB (2) Side B (V680-HA63) OMRON Corporation FCC ID: E4E6CYSIDV6800306 PWB(1) and PWB (2) in Case PWB(1) and PWB (2) in Case (V680-HS52) (V680-HS52) PWB(1) and PWB (2) in Case PWB(1) and PWB (2) in Case (V680-HS52) (V680-HS52) PWB (1) Side A (V680-HS52) PWB (1) Side B (V680-HS52) OMRON Corporation FCC ID: E4E6CYSIDV6800306 PWB (2) Side A (V680-HS52) PWB (2) Side B (V680-HS52) Composition Side A (V680-HS52) Composition Side B (V680-HS52) Composition Side C (V680-HS52) Composition Side D (V680-HS52) OMRON Corporation FCC ID: E4E6CYSIDV6800306 PWB(1) and PWB (2) in Case PWB (1) Side A (V680-HS63) (V680-HS63) PWB (1) Side B (V680-HS63) PWB (2) Side A (V680-HS63) PWB (2) Side B (V680-HS63) Composition Side A (V680-HS63) OMRON Corporation FCC ID: E4E6CYSIDV6800306 Composition Side B (V680-HS63) Composition Side C (V680-HS63) Composition Side D (V680-HS63)
FCC ID : E4E6CYCIDV6800306 Test report No. : 27AE0026-YK-A Page : 1 of 35 Issued date : September 12, 2006 Revised date : September 26, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) EMI TEST REPORT Test Report No. : 27AE0026-YK-A Applicant : OMRON Corporation Type of Equipment : Amplifier Model No. : V680-HA63 FCC ID : E4E6CYCIDV6800306 Test Standard : FCC Part15 Subpart C, Section 15.207, 15.209, 15.215, 15.225: 2006 Test Result : Complied 1. This test report shall not be reproduced except in full, without the written approval of UL Apex Co., Ltd. 2. The results in this report apply only to the sample tested. 3. This equipment is in compliance with the above regulation. 4. The test results in this test report are traceable to the national or international standards. Date of test: August 23, 25, 31 and September 26, 2006 Tested by: Akira Sato & Toyokazu Imamura Tatsuya Arai Approved by: Osamu Watatani Site Manager of Yamakita EMC Lab. FCC ID : E4E6CYCIDV6800306 Test report No. : 27AE0026-YK-A Page : 2 of 35 Issued date : September 12, 2006 Revised date : September 26, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Table of Contents Page 1 Applicant Information 3 2 Product Description 3 3 Test Specification, Procedures and Results 4 4 System Test Configuration 6 5 Conducted Emissions 7 6 Radiated Emissions (Fundamental, Spurious and Outside the Allocated bands) 8 7 20dB Bandwidth 9 8 Frequency Tolerance 9 Contents of Appendixes 10 APPENDIX 1: Photographs of test setup 11 APPENDIX 2: Test Data 19 APPENDIX 3: Test instruments 35 FCC ID : E4E6CYCIDV6800306 Test report No. : 27AE0026-YK-A Page : 3 of 35 Issued date : September 12, 2006 Revised date : September 26, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) 1 Applicant Information Company Name : OMRON Corporation Address : 3-2 Narutani, Nakayama-cho, Ayabe-shi, Kyoto-fu, 623-0105 JAPAN Telephone Number : +81-773-42-6662 Facsimile Number : +81-773-42-6135 Contact Person : Tatsuo Yoshida 2 Product Description Type of Equipment : Amplifier Model No. : V680-HA63 Serial No. : 52 Rating : DC7.5V Country of Manufacture : Japan Receipt Date of Sample : August 23, 2006 Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No modification by the test lab. Model: V680-HA63 (referred to as the EUT in this report) is an Amplifier. Equipment type : Transceiver Frequency of operation : 13.56 MHz Type of modulation : ASK Antenna type : Loop coil antenna Antenna connector type : BNC Mode of operation : Simplex Other clock frequency : 12MHz (USB), 16MHz (CPU) Emission Designation : A1D Operation temperature range: -10 ~ 55 deg. C. *FCC Part15.31 (e) The ID Controller provides the Amplifier with stable power supply and the equipment complies power supply regulation. *FCC Part15.203 The EUT has an external and particular antenna connector, but it is installed by the professionals. Therefore, the equipment complies with the antenna requirement of Section 15.203. FCC ID : E4E6CYCIDV6800306 Test report No. : 27AE0026-YK-A Page : 4 of 35 Issued date : September 12, 2006 Revised date : September 26, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) 3 Test Specification, Procedures and Results 3.1 Test specification Test specification : FCC Part15 Subpart C: 2006 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.207: Conducted limits Section 15.209: Radiated emission limits, general requirements Section 15.215: Additional provisions to the general radiated emission limitations Section 15.225: Operation within the band 13.110-14.010MHz 3.2 Procedures & Results Item Test Procedure Specification Remarks DeviationWorst Margin Results Conducted Emission ANSI C63.4: 2003 7. AC powerline conducted emission measurements Section 15.207 - N/A 7.3dB (13.56MHz, N, AV) Complied Electric Field Strength of Fundamental Emission ANSI C63.4: 2003 13. Measurement of intentional radiators Section 15.225 (a)Radiated N/A 63.7dB (Horizontal, with V680-HS63) Complied Electric Field Strength of Outside the Allocated bands ANSI C63.4: 2003 13. Measurement of intentional radiators Section 15.225 (b) (c) Radiated N/A 45.10dB (14.010MHz, Horizontal, with V680-HS63) Complied Electric Field Strength of Spurious Emission ANSI C63.4: 2003 13. Measurement of intentional radiators Section15.209, Section 15.225 (d) Radiated N/A 7.2dB (81.36MHz, Vertical) Complied 20dB Bandwidth ANSI C63.4: 2003 13. Measurement of intentional radiators Section15.215(c) Radiated N/A - Complied Frequency Tolerance ANSI C63.4: 2003 13. Measurement of intentional radiators Section15.225 (e) Radiated N/A - Complied Note: UL Apex’s EMI Work Procedures No.QPM05. * No addition, exclusion nor deviation has been made from the standard. FCC ID : E4E6CYCIDV6800306 Test report No. : 27AE0026-YK-A Page : 5 of 35 Issued date : September 12, 2006 Revised date : September 26, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) 3.3 Uncertainty Conducted emission The measurement uncertainty (with 95% confidence level) for this test is ±2.7dB. The data listed in this test report has enough margin, more than site margin. Radiated emission The measurement uncertainty (with a 95% confidence level) for this test using Loop antenn…
Text truncated - open the document above for the full version.
FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 11 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Conducted emission FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 12 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Radiated emission (9kHz-30MHz, with Antenna: V680-HS52) FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 13 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Radiated emission (30-1000MHz, with Antenna: V680-HS52) FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 14 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Radiated emission (9kHz-30MHz, with Antenna: V680-HS63) FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 15 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Radiated emission (30-1000MHz, with Antenna: V680-HS63) FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 16 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Pre-check of the worst position (Amplifier) X-axis Y-axis Z-axis FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 17 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Pre-check of the worst position (Antenna: V680-HS52) Worst-case combination Amplifier Antenna Horizontal Vertical Horizontal Vertical with V680-HS52 X X X X with V680-HS63 X X Y Y X-axis Y-axis FCC ID : E4E6CYSIDV6800306 Test report No. : 27AE0026-YK-A Page : 18 of 33 Issued date : September 12, 2006 UL Apex Co., Ltd. YAMAKITA EMC LAB. 907 Kawanishi, Yamakita-machi, Ashigarakami-gun, Kanagawa-ken, 258-0124 JAPAN Telephone: +81 465 77 1011 Facsimile: +81 465 77 2112 MF060b (14.06.06) Pre-check of the worst position (Antenna: V680-HS63) X-axis Y-axis Z-axis
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
RFID Amplifier Unit
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Carrier ID Reader/Writer (RFID)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Carrier ID Reader/Writer (RFID)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Radio Frequency Identification System (RFID System)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Radio Frequency Identification System (RFID System)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter